998 resultados para Déserteurs. Année 1731, dossier Boulanger (Jean-Louis)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

t.1

Relevância:

100.00% 100.00%

Publicador:

Resumo:

t.2

Relevância:

100.00% 100.00%

Publicador:

Resumo:

t.3

Relevância:

100.00% 100.00%

Publicador:

Resumo:

t.4

Relevância:

100.00% 100.00%

Publicador:

Resumo:

t.5

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aquest article descriu els sensors enzimàtics i immunosensors electroquímics que s’han desenvolupat als nostres grups per a la detecció de la biotoxina marina àcid okadaic (OA), i discuteix la possibilitat d’integrar-los en programes de seguiment. Els sensors enzimàtics per a OA que es presenten es basen en la inhibició de la proteïna fosfatasa (PP2A) per aquesta toxina i la mesura electroquímica de l’activitat enzimàtica mitjançant l’ús de substrats enzimàtics apropiats, electroquímicament actius després de la seva desfosforació per l’enzim. Els immunosensors electroquímics descrits en aquest article es basen en un enzimoimmunoassaig sobre fase sòlida competitiu indirecte (ciELISA), amb fosfatasa alcalina (ALP) o peroxidasa (HRP) com a marcatges, i un sistema de reciclatge enzimàtic amb diaforasa (DI). Els biosensors presentats aquí s’han aplicat a l’anàlisi de dinoflagel·lats, musclos i ostres. Les validacions preliminars amb assaigs colorimètrics i LC-MS/MS han demostrat la possibilitat d’utilitzar les bioeines desenvolupades per al cribratge preliminar de biotoxines marines en mostres de camp o de cultiu, que ofereixen informació complementària a la cromatografia. En conclusió, tot i que encara cal optimitzar alguns paràmetres experimentals, la integració dels biosensors a programes de seguiment és viable i podria proporcionar avantatges respecte a altres tècniques analítiques pel que fa al temps d’anàlisi, la simplicitat, la selectivitat, la sensibilitat, el fet de poder ser d’un sol ús i l’efectivitat de cost. This article describes the electrochemical enzyme sensors and immunosensors that have been developed by our groups for the detection of marine biotoxin okadaic acid (OA), and discusses the possibility of integrating them into monitoring programmes. The enzyme sensors for OA reported herein are based on the inhibition of immobilised protein phosphatase 2A (PP2A) by this toxin and the electrochemical measurement of the enzyme activity through the use of appropriate enzyme substrates, which are electrochemically active after dephosphorylation by the enzyme. The electrochemical immunosensors described in this article are based on a competitive indirect Enzyme- Linked ImmunoSorbent Assay (ciELISA), using alkaline phosphatase (ALP) or horseradish peroxidase (HRP) as labels, and an enzymatic recycling system with diaphorase (DI). The biosensors presented herein have been applied to the analysis of dinoflagellates, mussels and oysters. Preliminary validations with colorimetric assays and LC-MS/MS have demonstrated the possibility of using the developed biotools for the preliminary screening of marine biotoxins in field or cultured samples, offering complementary information to chromatography. In conclusion, although optimisation of some experimental parameters is still required, the integration of biosensors into monitoring programmes is viable and may provide advantages over other analytical techniques in terms of analysis time, simplicity, selectivity, sensitivity, disposability of electrodes and cost effectiveness.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The most unique characteristic of a parasite when it is in its normal host is the ability to make itself tolerated, which clearly indicates that it has sophisticated means to ensure the neutrality of its host. This is true also in the case of Plasmodium falciparum, since after numerous malaria attacks an equilibrium is reached with a chronic stage of infection, characterized by a relatively low parasitemia, and low or no disease (Sergent & Parrot 1935). We shall briefly review the main characteristics of this state of "premunition", and present data suggesting that the underlying mechanisms of defense rely on the cooperation between cell and antibodies, leading to an antibody dependent cellular inhibition of the intra-erythrocytic growth of the parasite.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Upon agonist stimulation, endothelial cells trigger smooth muscle relaxation through the release of relaxing factors such as nitric oxide (NO). Endothelial cells of mouse aorta are interconnected by gap junctions made of connexin40 (Cx40) and connexin37 (Cx37), allowing the exchange of signaling molecules to coordinate their activity. Wild-type (Cx40(+/+)) and hypertensive Cx40-deficient mice (Cx40(-/-)), which also exhibit a marked decrease of Cx37 in the endothelium, were used to investigate the link between the expression of endothelial connexins (Cx40 and Cx37) and endothelial nitric oxide synthase (eNOS) expression and function in the mouse aorta. With the use of isometric tension measurements in aortic rings precontracted with U-46619, a stable thromboxane A(2) mimetic, we first demonstrate that ACh- and ATP-induced endothelium-dependent relaxations solely depend on NO release in both Cx40(+/+) and Cx40(-/-) mice, but are markedly weaker in Cx40(-/-) mice. Consistently, both basal and ACh- or ATP-induced NO production were decreased in the aorta of Cx40(-/-) mice. Altered relaxations and NO release from aorta of Cx40(-/-) mice were associated with lower expression levels of eNOS in the aortic endothelium of Cx40(-/-) mice. Using immunoprecipitation and in situ ligation assay, we further demonstrate that eNOS, Cx40, and Cx37 tightly interact with each other at intercellular junctions in the aortic endothelium of Cx40(+/+) mice, suggesting that the absence of Cx40 in association with altered Cx37 levels in endothelial cells from Cx40(-/-) mice participate to the decreased levels of eNOS. Altogether, our data suggest that the endothelial connexins may participate in the control of eNOS expression levels and function.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

(Résumé de l'ouvrage) Ce livre a trait ici au ministère pastoral, problème central de la théologie aux yeux du théologien protestant Jean-Louis Leuba. Se joue en effet sur le ministère toute la question de la transmission du credo et de la légitimation de sa vérité aux diverses époques. Jean-Louis Leuba propose en préambule du livre des thèses sur le ministère que ses interlocuteurs - théologiens protestants, catholiques, luthériens, ainsi qu'un sociologue des religions - vont reprendre pour les accueillir avec leurs sensibilités ou les réfuter.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION Evidence-based recommendations can be made with respect to many aspects of the acute management of the bleeding trauma patient, which when implemented may lead to improved patient outcomes. METHODS The multidisciplinary Task Force for Advanced Bleeding Care in Trauma was formed in 2005 with the aim of developing guidelines for the management of bleeding following severe injury. Recommendations were formulated using a nominal group process and the GRADE (Grading of Recommendations Assessment, Development, and Evaluation) hierarchy of evidence and were based on a systematic review of published literature. RESULTS Key recommendations include the following: The time elapsed between injury and operation should be minimised for patients in need of urgent surgical bleeding control, and patients presenting with haemorrhagic shock and an identified source of bleeding should undergo immediate surgical bleeding control unless initial resuscitation measures are successful. A damage control surgical approach is essential in the severely injured patient. Pelvic ring disruptions should be closed and stabilised, followed by appropriate angiographic embolisation or surgical bleeding control, including packing. Patients presenting with haemorrhagic shock and an unidentified source of bleeding should undergo immediate further assessment as appropriate using focused sonography, computed tomography, serum lactate, and/or base deficit measurements. This guideline also reviews appropriate physiological targets and suggested use and dosing of blood products, pharmacological agents, and coagulation factor replacement in the bleeding trauma patient. CONCLUSION A multidisciplinary approach to the management of the bleeding trauma patient will help create circumstances in which optimal care can be provided. By their very nature, these guidelines reflect the current state-of-the-art and will need to be updated and revised as important new evidence becomes available.