964 resultados para Conventional sprinkler
Resumo:
In upland rice, the reduced grain yield that originates from the moisture stress period is related to the plant's tolerance of water deficiency and may vary between cultivars. The purpose of the work presented here was to evaluate the performance of upland rice cultivars in both rainfed and sprinkler-irrigated systems. A split-plot scheme with 8 replicates in a randomised block design was used. The plots were composed of 2 cropping systems (rainfed and sprinkler-irrigated) and the split-plot consisted of 2 cultivars (IAC 201 and Carajas) which are suggested for cultivation in upland ecosystems. Carajas had a greater number of panicles per square metre, higher spikelet fertility and grain mass, and, consequently, a higher grain yield than IAC 201 regardless of cropping system. IAC 201 was more sensitive to water deficiency than Carajas. Sprinkler irrigation improved spikelet fertility, grain mass and upland rice grain yield. Even when cultivars with a higher tolerance of water deficiency are used, a sprinkler-irrigated system may be a viable method to increase upland rice yield throughout most of the Brazilian Cerrado.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this work, we describe an experimental setup in which an electric current is used to determine the angular velocity attained by a plate rotating around a shaft in response to a torque applied for a given period. Based on this information, we show how the moment of inertia of a plate can be determined using a procedure that differs considerably from the ones most commonly used, which generally involve time measurements. Some experimental results are also presented which allow one to determine parameters such as the exponents and constant of the conventional equation of a plate's moment of inertia.
Resumo:
The work reported here involved an investigation into the grinding process, one of the last finishing processes carried out on a production line. Although several input parameters are involved in this process, attention today focuses strongly on the form and amount of cutting fluid employed, since these substances may be seriously pernicious to human health and to the environment, and involve high purchasing and maintenance costs when utilized and stored incorrectly. The type and amount of cutting fluid used directly affect some of the main output variables of the grinding process which are analyzed here, such as tangential cutting force, specific grinding energy, acoustic emission, diametrical wear, roughness, residual stress and scanning electron microscopy. To analyze the influence of these variables, an optimised fluid application methodology was developed (involving rounded 5, 4 and 3 turn diameter nozzles and high fluid application pressures) to reduce the amount of fluid used in the grinding process and improve its performance in comparison with the conventional fluid application method (of diffuser nozzles and lower fluid application pressure). To this end, two types of cutting fluid (a 5% synthetic emulsion and neat oil) and two abrasive tools (an aluminium oxide and a superabrasive CBN grinding wheel) were used. The results revealed that, in every situation, the optimised application of cutting fluid significantly improved the efficiency of the process, particularly the combined use of neat oil and CBN grinding wheel. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
The purpose of this work is to explain the concept of cutting fluids reasonable usage through the fluid minimum quantity in grinding processes. on that purpose, the development of a new nozzle and an own and adequate methodology should be required in order to obtain good results and compare them to the conventional methods. The analysis of the grinding wheel/cutting fluid performance was accomplished from the following input parameters: flow rate variation by nozzle diameter changes (three diameters values: 3mm, 4mm and 5mm), besides the conventional round nozzle already within the machine. Integral oil and a synthetic emulsion were used as cutting fluids and a conventional grinding wheel was employed. The workpieces were made of steel VC 131, tempered and quenched with 60HRc. Thus, as the flow rate and the nozzle diameter changes, keeping steady fluid jet velocity (equal to cutting velocity), attempted to find the best machining conditions, with the purpose to obtain a decrease on the cutting fluid volume, taking into consideration the analysis of the process output variables such as cutting strength, cutting specific energy, grinding wheel wear and surface roughness. It was verified that the 3mm diameter optimized nozzle and the integral oil, in general, was the best combination among all proposed.
Resumo:
The non-ohmic and dielectric properties as well as the dependence on the microstructural features of CaCu(3)Ti(4)O(12)/CaTiO(3) ceramic composites obtained by conventional and microwave sintering were investigated. It was demonstrated that the non-ohmic and dielectric properties depend strongly on the sintering conditions. It was found that the non-linear coefficient reaches values of 65 for microwave-sintered samples and 42 for samples sintered in a conventional furnace when a current density interval of 1-10 mA cm(-2) is considered. The non-linear coefficient value of 65 is equivalent to 1500 for samples sintered in the microwave if a current interval of 5-30 mA is considered as is shortly discussed by Chung et al (2004 Nature Mater. 3 774). Due to a high non-linear coefficient and a low leakage current (90 mu A) under both processing conditions, these samples are promising for varistor applications. The conventionally sintered samples exhibit a higher relative dielectric constant at 1 kHz (2960) compared with the samples sintered in the microwave furnace (2100). At high frequencies, the dielectric constant is also larger in the samples sintered in the conventional furnace. Depending on the application, one or another synthesis methodology is recommended, that is, for varistor applications sintered in a microwave furnace and for dielectric application sintered in a conventional furnace.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Aim. Duplex scanning has been used in the evaluation of the aorta and proximal arteries of the lower extremities, but has limitations in evaluating the arteries of the leg. The utilization of ultrasonographic contrast (USC) may be helpful in improving the quality of the image in these arteries. The objective of the present study was to verify whether the USC increases the diagnostic accuracy of patency of the leg arteries and if it diminishes the time needed to perform duplex scanning.Methods. Twenty patients with critical ischemia (20 lower extremities) were examined by standard duplex scanning, duplex scanning with contrast and digital subtraction arteriography (DSA). The 3 arteries of the leg were divided into 3 segments, for a total of 9 segments per limb. Each segment was evaluated for patency in order to compare the 3 diagnostic methods. Comparison was made between standard duplex scanning and duplex scanning with contrast in terms of quality of the color-coded Doppler signal and of the spectral curve, and also of the time to perform the exams.Results. Duplex scanning with contrast was similar to arteriography in relation to patency diagnosis (p>0.3) and even superior in some of the segments. Standard duplex scanning was inferior to arteriography and to duplex scanning with contrast (p<0.001). There were improvements of 70% in intensity of the color-coded Doppler signal and 76% in the spectral curve after the utilization of contrast. The time necessary to perform the examinations was 23.7 minutes for standard duplex scanning and 16.9 minutes for duplex scanning with contrast (p<0.001).Conclusion. The use of ultrasonographic contrast increased the accuracy of the diagnosis of patency of leg arteries and diminished the time necessary for the execution of duplex scanning.
Resumo:
Objective: To evaluate whether intracytoplasmic morphologically selected sperm injection (IMSI) could influence early paternal effects by observing embryo quality at day 2.Study design: The study included 30 couples with at least one of the following criteria: male factor infertility, at least 2 previous failures of implantation or previous miscarriages after IVF/ICSI. Sibling oocytes of each patient were randomly assigned to either the ICSI group or the IMSI group. For IMSI, spermatozoa were selected at 8400x magnification through an inverted microscope equipped with Nomarski differential interference contrast optics, Uplan Apo 100x oil/1.35 objective lens and variable zoom lens. For conventional ICSI, spermatozoa were selected at 400x magnification. An embryo was defined as top quality if there were four identical blastomeres on day 2 with no fragments or multinucleation of blastomeres. Data were analysed using the Wilcoxon and chi-squared tests. The significance level was set at P < 0.05. The variables were analysed in relation to the general population and the subpopulations with or without male factor.Results: A total of 331 MII oocytes (30 oocyte retrievals) were selected and injected by the ICSI (n: 172) or IMSI (n: 159) procedure. For IMSI, only spermatozoa classified as morphologically normal at high magnification were used. No differences (P > 0.05) in fertilisation rate (ICSI: 70.9%; IMSI: 70.4%), early embryo cleavage rate (ICSI: 66.9%; IMSI: 60.4%) or cleavage rate (ICSI: 99.2%; IMSI: 99.1%) were observed. on day 2, as compared to ICSI, IMSI provided a similar proportion of top quality embryos (ICSI: 57.8%; IMSI: 52.2%; P > 0.05). These results were not influenced by the presence or absence of male factor.Conclusion: In terms of embryo quality at day 2, IMSI had the same performance as conventional ICSI. However, we cannot exclude the possibility that IMSI effects occur only as a positive later paternal effect. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
The aim of this study was to evaluate the application of PCR technique for the detection of BoHV-5 in routinely formalin-fixed, paraffin-embedded brain tissues in 20 naturally infected calves affected by fatal meningoencephalitis. Brains were divided into two halves, one kept fresh for virus isolation and PCR assay, targeting the glycoprotein C gene from BoHV-5 genome. The other half brain, corresponding to posterior cortex region, was submitted to formalin fixation and embedded into paraffin blocks for microscopic evaluation and total DNA isolation. Most of the slides showed severe multifocal non-supurative encephalitis with neuronal degeneration, neurophagia, and no acidophilic intranuclear inclusions could be found in neurons and glial. The 20 fresh samples were confirmed, by virus isolation and PCR assay, as having the BoHV-5 virus and, respective glicoprotein C sequence, while 15 of 20 formalin-fixed, paraffin-embedded samples were considered positive for the same analysis. The results revealed the first description of PCR efficiency, applied to formalin-fixed, paraffin-embedded brain collected from naturally infected calves, improving the detection of BoHV-5 from archival samples in South America. (c) 2007 Published by Elsevier B.V.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A cárie secundária representa problema de saúde pública e socioeconômico no mundo. A restauração de dentes acometidos por cárie pode criar condições favoráveis à proliferação microbiana na superfície do material restaurador ou na interface dente/restauração, criando ambiente propício para o estabelecimento de cárie secundária. O objetivo deste estudo foi avaliar a capacidade de retenção de placa bacteriana em cimentos de ionômero de vidro convencionais (Chelon-Fil e Vidrion R) e modificados por resina (Vitremer e Fuji II LC) e de resina composta híbrida (Z100), utilizada como controle. Nos testes de retenção de microrganismos, in situ, 12 voluntários utilizaram, por 7 dias, placa de Hawley contendo corpos-de-prova de todos os materiais. A seguir, os corpos-de-prova foram transferidos para tubos contendo 2,0 ml de Ringer-PRAS e os microrganismos presentes em sua superfície foram cultivados em placa com ágar-sangue e ágar Mitis Salivarius Bacitracina, os quais foram incubados, a 37ºC, em anaerobiose (90% N2, 10% CO2), por 10 e 2 dias, respectivamente. Os ionômeros modificados por resina retiveram quantidade de bactérias similar àquela mostrada pela resina testada. Os ionômeros modificados por resina também apresentaram menor número de estreptococos do grupo mutans do que a resina e os cimentos ionoméricos convencionais. Os ionômeros de vidro convencionais apresentaram menor número de estreptococos do grupo mutans que a resina, sendo que essa diferença não foi estatisticamente significativa.
Resumo:
This in vitro study evaluated the influence of the type of miniplate and the number of screws installed in the proximal and distal segments on the stability and resistance of Champy's osteosynthesis in mandibular angle fractures. Sixty polyurethane hemimandibles with bone-like consistency were randomly assigned to four groups (n = 15) and sectioned in the mandibular angle region to simulate fracture. The bone segments were fixed by different osteosynthesis methods using 2.0 mm miniplates and 2.0 mm x 6 mm rnonocortical screws. In groups 1 and 2, two conventional (G1) or locking (G2) screws were installed in each bone segment using a conventional (G1) or a locking (02) straight miniplate; in groups 3 and 4, three conventional (03) or locking (04) screws were installed in the proximal segment and four conventional (G3) or locking (04) screws were installed in the distal segment using a conventional (G3) or a locking (G4) seven-hole straight miniplate. The hemimandibles were loaded in compressive strength until a 4 mm displacement occurred between the segments, vertically or horizontally. Locking plate/screw systems provided significantly greater resistance to displacement than conventional ones (p < .01). Locking miniplates offered more resistance than conventional miniplates. Long locking miniplates provided greater stability than short ones.