914 resultados para Composite polymer blend. Polyethylene terephthalate. Polyethylenemethyl acrylate. And cotton linter


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: This study presents estimates of 12 month and current prevalences of DSM-IV disorders, and the related comor-bidity, disability and service utilization, derived from a national probability sample in Australia. Methods: The DSM-IV psychiatric disorders among persons aged 18 and over in the Australian population were assessed with data collected by lay interviewers using the Composite International Diagnostic Interview, other screening interviews and measures of disability and service utilization. The response rate was 78.1% and the final sample size was 10,641 adults. Results: Close to 20% reported at least one twelve month disorder and 13% a disorder current within the past 30 days. ICD-10 diagnoses were also derived, DSM-IV was the more conservative classification whether or not the new clinical significance criteria was applied. Major depression, any personality disorder, and alcohol dependence were the three most common twelve month disorders, generalized anxiety disorder replaced alcohol dependence as the third most common current disorder. The sexes has similar rates of any disorder, but women had higher rates of affective and anxiety disorders, men higher rates of substance use disorders. Prevalence of most disorders declined with age and education, and were lower among those employed or married. Respondents whose symptoms met criteria for three or more disorders in the past year had greatly increased rates of disability and of mental health consultations. The affective and somatoform disorders were associated with the highest rates of disability. Only 36% of people with a mental disorder this year had consulted for a mental problem, and most had seen a general practitioner. We identified those with a current disorder who were disabled or multiply comorbid - only half had consulted and of those who had not, more than half said they did not need treatment. Conclusions: The 12 month prevalence was lower than reported in the US National Comorbidity Survey but method factors might account for this. The relationships between prevalence and demographic variables, and between comorbidity, disability and service utilization were similar to those found in the US survey. Australia has a national health insurance scheme with total coverage and access to medical help is available to all, commonly at little or no cost. We identify the high rate of not consulting among those with a current disorder, and additional disability or multiple comorbidity, as an important public health problem. Kessler argued for more research on barriers to professional help seeking. This report reinforces his conclusion and shows that economic barriers are not the dominant issue.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hydrogels with various compositions of polyvinyl alcohol (PVA) and poly(1-vinyl-2-pyrrolidinone) (PVP) were prepared by irradiating mixtures of PVA and PVP in aqueous solutions with gamma-rays from Co-60 sources at room temperature. The states of water in the hydrogels were characterized using DSC and NMR T-2 relaxation measurements and the kinetics of water diffusion in the hydrogels were studied by sorption experiments and NMR imaging. The DSC endothermic peaks in the temperature range -10 to +10 degrees C implied that there are at least two kinds of freezable water present in the matrix. The difference between the total water content and the freezable water content was refer-red to as bound water, which is not freezable. The weight fraction of water at which only nonfreezable water is present in a hydrogel with F-VP = 0.19 has been estimated to be g(H2O)/g(Polymer) = 0.375. From water sorption experiments, it was demonstrated that the early stage of the diffusion of water into the hydrogels was Fickian. A curve-fit of the early-stage experimental data to the Fickian model allowed determination of the water diffusion coefficient, which was found to lie between 1.5 x 10(-11) m(2) s(-1) and 4.5 x 10(-11) m(2) s(-1), depending on the polymer composition, the cross-link density, and the temperature. It was also found that the energy barrier for diffusion of water molecules into PVA/PVP hydrogels was approximate to 24 kJ mol(-1). Additionally, the diffusion coefficients determined from NMR imaging of the volumetric swelling of the gels agreed well with the results obtained by the mass sorption method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate whether the number of vessels disease has an impact on clinical outcomes as well as on therapeutic results accordingly to medical, percutaneous, or surgery treatment in chronic coronary artery disease. Methods: We evaluated 825 individuals enrolled in MASS study, a randomized study to compare treatment options for single or multivessel coronary artery disease with preserved left ventricular function, prospectively followed during 5 years. The incidence of overall mortality and the composite end-point of death, myocardial infarction, and refractory angina were compared in three groups: single vessel disease (SVD n = 214), two-vessel disease (2VD n = 253) and three-vessel disease (3VD n = 358). The relationship between baseline variables and the composite end-point was assessed using a Cox proportional hazards survival model. Results: Most baseline characteristics were similar among groups, except age (younger in SVD and older in 3VD, p < 0.001), lower incidence of hypertension in SVD (p < 0.0001), and lower levels of total and LDL-cholesterol in 3VD (p = 0.004 and p = 0.005, respectively). There were no statistical differences in composite end-point in 5 years among groups independent of the kind of treatment; however, there was a higher mortality rate in 3VD (p < 0.001). When we stratified our analysis for each treatment option, bypass surgery was associated with a tower number of composite end-point in all groups (SVD p < 0.001, 2VD p = 0.002, 3VD p < 0.001). In multivariate analysis, we found higher mortality risk in 3VD comparing to SVD (p = 0.005, HR 3.14, 95%Cl 1.4-7.0). Conclusion: Three-vessel disease was associated with worse prognosis compared to single-or two-vessel disease in patients with stable coronary disease and preserved ventricular function at 5-year follow-up. In addition, event-free survival rates were higher after bypass surgery, independent of the number of vessels diseased in these subsets of patients. (c) 2008 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The purpose of this in vitro study was to evaluate the Vickers hardness (VHN) of a Light Core (Bisco) composite resin after root reinforcement, according to the light exposure time, region of intracanal reinforcement and lateral distance from the light-transmitting fibre post. Methods: Forty-five 17-mm long roots were used. Twenty-four hours after obturation, the root canals were emptied to a depth of 12 mm and the root dentine was artificially flared to produce a 1 mm space between the fibre post and the canal walls. The roots were bulk restored with the composite resin, which was photoactivated through the post for 40 s (G1, control), 80 s (G2) or 120 s (G3). Twenty-four hours after post-cementation, the specimens were sectioned transversely into three slices at depths of 2, 6 and 10 mm, corresponding to the coronal, middle and apical regions of the reinforced root. Composite VHN was measured as the average of three indentations (100 g/15 s) in each region at lateral distances of 50, 200 and 350 mu m from the cement/post-interface. Results: Three-way analysis of variance (alpha = 0.05) indicated that the factors time, region and distance influenced the hardness and that the interaction time x region was statistically significant (p = 0.0193). Tukey`s test showed that the mean VHN values for G1 (76.37 +/- 8.58) and G2 (74.89 +/- 6.28) differed significantly from that for G3 (79.5 +/- 5.18). Conclusions: Composite resin hardness was significantly lower in deeper regions of root reinforcement and in lateral areas distant from the post. Overall, a light exposure time of 120 s provided higher composite hardness than the shorter times (40 and 80 s). (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dynamic theological behaviour of gamma-irradiated 12.8 wt% poly(vinyl alcohol) (PVA), 12.8 wt% poly(vinyl pyrrolidone) (PVP), and a blend of 8 wt% PVA and 4.8 wt% PVP aqueous solutions have been studied pre- and post-gelation. The non-irradiated solutions displayed theological behaviour typical of dilute to semi-dilute polymer solutions, with the complex viscosity being independent of the frequency and shear rate (i.e. Newtonian behaviour) over the range of frequencies tested and the loss modulus G(omega) and storage modulus G(omega) being nearly proportional to omega and omega(2) respectively. After a set of doses of gamma-radiation, the magnitudes of the dynamic moduli G'(omega) and G(omega) increased as the absorbed dose increased, with notable differences between the two homopolymers and the blend. The stages of gelation were effectively monitored by means of dynamic theological measurements, allowing the possible mechanisms of network formation to be elucidated. The doses required for gelation of the PVA, PVP, and blend samples, determined on the basis of the Winter and Chambon criteria for gelation, were found to be 12 kGy for the 12.8 wt% PVA, 4 kGy for the 12.8 wt% PVP, and 5 kGy for the 8 wt% PVA/4.8 wt% PVP solutions. The unexpected lower gelation dose demonstrated by the blend sample, compared with predictions based on the blend composition, and the associated gelation mechanism are also discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Tissue Doppler may be used to quantify regional left ventricular function but is limited by segmental variation of longitudinal velocity from base to apex and free to septal walls. We sought to overcome this by developing a composite of longitudinal and radial velocities. Methods and Results. We examined 82 unselected patients undergoing a standard dobutamine echocardiogram. Longitudinal velocity was obtained in the basal and mid segments of each wall using tissue Doppler in the apical views. Radial velocities were derived in the same segments using an automated border detection system and centerline method with regional chords grouped according to segment location and temporally averaged. In 25 patients at low probability of coronary disease, the pattern of regional variation in longitudinal velocity (higher in the septum) was the opposite of radial velocity (higher in the free wall) and the combination was homogenous. In 57 patients undergoing angiography, velocity in abnormal segments was less than normal segments using longitudinal (6.0 +/- 3.6 vs 9.0 +/- 2.2 cm/s, P = .01) and radial velocity (6.0 +/- 4.0 vs 8.0 +/- 3.9 cm/s, P = .02). However, the composite velocity permitted better separation of abnormal and normal segments (13.3 +/- 5.6 vs 17.5 +/- 4.2 cm/s, P = .001). There was no significant difference between the accuracy of this quantitative approach and expert visual wall motion analysis (81% vs 84%, P = .56). Conclusion: Regional variation of uni-dimensional myocardial velocities necessitates site-specific normal ranges, probably because of different fiber directions. Combined analysis of longitudinal and radial velocities allows the derivation of a composite velocity, which is homogenous in all segments and may allow better separation of normal and abnormal myocardium.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The risk of cardiac events in patients undergoing major noncardiac surgery is dependent on their clinical characteristics and the results of stress testing. The purpose of this study was to develop a composite approach to defining levels of risk and to examine whether different approaches to prophylaxis influenced this prediction of outcome. One hundred forty-five consecutive patients (aged 68 +/- 9 years, 79 men) with >1 clinical risk variable were studied with standard dobutamine-atropine stress echo before major noncardiac surgery. Risk levels were stratified according to the presence of ischemia (new or worsening wall motion abnormality), ischemic threshold (heart rate at development of ischemia), and number of clinical risk variables. Patients were followed for perioperative events (during hospital admission) and death or infarction over the subsequent 16 10 months. Ten perioperative events occurred in 105 patients who proceeded to surgery (10%, 95% confidence interval [CI] 5% to 17%), 40 being cancelled because of cardiac or other risk. No ischemia was identified in 56 patients, 1 of whom (1.8%) had a perioperative infarction. Of the 49 patients with ischemia, 22 (45%) had 1 or 2 clinical risk factors; 2 (9%, 95% CI 1% to 29%) had events. Another 15 patients had a high ischemic threshold and 3 or 4 risk factors; 3 (20%, 95% Cl 4% to 48%) had events. Twelve patients had a low ischemic threshold and 3 or 4 risk factors; 4 (33%, 95% CI 10% to 65%) had events. Preoperative myocardial revascularization was performed in only 3 patients, none of whom had events. Perioperative and long-term events occurred despite the use of beta blockers; 7 of 41 eta blocker-treated patients had a perioperative event (17%, 95% CI 7% to 32%); these treated patients were at higher anticipated risk than untreated patients (20 +/- 24% vs 10 +/- 19%, p = 0.02). The total event rate over late follow-up was 13%, and was predicted by dobutamine-atropine stress echo results and heart rate response. (C) 2002 by Excerpta Medica, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The variation of the physical properties of four differ- ent carbon nanofibers (CNFs), based-polymer nano- composites incorporated in the same polypropylene (PP) matrix by twin-screw extrusion process was investigated. Nanocomposites fabricated with CNFs with highly graphitic outer layer revealed electrical isolation-to-conducting behaviors as function of CNF’s content. Nanocomposites fabricated with CNFs with an outer layer consisting on a disordered pyro- litically stripped layer, in contrast, revealed better mechanical performance and enhanced thermal sta- bility. Further, CNF’s incorporation into the polymer increased the thermal stability and the degree of crystallinity of the polymer, independently on the filler content and type. In addition, dispersion of the CNFs’ clusters in PP was analyzed by transmitted light opti- cal microscopy, and grayscale analysis (GSA). The results showed a correlation between the filler concentration and the variance, a parameter which measures quantitatively the dispersion, for all composites. This method indicated a value of 1.4 vol% above which large clusters of CNFs cannot be dispersed effectively and as a consequence only slight changes in mechanical performance are observed. Finally, this study establishes that for tailoring the physical properties of CNF based-polymer nanocomposites, both adequate CNFs structure and content have to be chosen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article describes an experimental study on ash deposition during the co-firing of bituminous coal with pine sawdust and olive stones in a laboratory furnace. The main objective of this study was to relate the ash deposit rates with the type of biomass burned and its thermal percentage in the blend. The thermal percentage of biomass in the blend was varied between 10% and 50% for both sawdust and olive stones. For comparison purposes, tests have also been performed using only coal or only biomass. During the tests, deposits were collected with the aid of an air-cooled deposition probe placed far from the flame region, where the mean gas temperature was around 640 degrees C. A number of deposit samples were subsequently analyzed on a scanning electron microscope equipped with an energy dispersive X-ray detector. Results indicate that blending sawdust with coal decreases the deposition rate as compared with the firing of unblended coal due to both the sawdust low ash content and its low alkalis content. The co-firing of coal and sawdust yields deposits with high levels of silicon and aluminium which indicates the presence of ashes with high fusion temperature and, thus, with less capacity to adhere to the surfaces. In contrast, in the co-firing of coal with olive stones the deposition rate increases as compared with the firing of unblended coal and the deposits produced present high levels of potassium, which tend to increase their stickiness.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Deuterium NMR was used to investigate the orientational order in a composite cellulosic formed by liquid crystalline acetoxypropylcellulose (A PC) and demented nematic 4'-penty1-4-cyanobiphenyl (5CB-4 alpha d(2)) with the per centage of 85% A PC by weight Three forms of the composite including electro spun microfibers, thin film and bulk samples were analyzed The NMR results initially suggest two distinct scenarios, one whet e the 503-alpha d(2), is confined to small droplets with dimensions smaller than the magnetic coherence length and the other where the 503-alpha d(2) molecules arc aligned with the A PC network chains Polarized optical microscopy (POW from thin film samples along with all the NMR results show the presence of 5CB-alpha d(2) droplets in the composite systems with a nematic wetting layer at the APC-5CB-alpha d(2) interface that experiences and order disorder transition driven by the polymer network N-I transition The characterization of the APC network I-N transition shows a pronounced subcritical behavior within a heterogeneity scenario.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors extend their earlier work on the stability of a reacting binary polymer blend with respect to demixing [D. J. Read, Macromolecules 31, 899 (1998); P. I. C. Teixeira , Macromolecules 33, 387 (2000)] to the case where one of the polymers is rod-like and may order nematically. As before, the authors combine the random phase approximation for the free energy with a Markov chain model for the chemistry to obtain the spinodal as a function of the relevant degrees of reaction. These are then calculated by assuming a simple second-order chemical kinetics. Results are presented, for linear systems, which illustrate the effects of varying the proportion of coils and rods, their relative sizes, and the strength of the nematic interaction between the rods. (c) 2007 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to carry out experimental work to determine, for Newtonian and non-Newtonian fluids, the friction factor (fc) with simultaneous heat transfer, at constant wall temperature as boundary condition, in fully developed laminar flow inside a vertical helical coil. The Newtonian fluids studied were aqueous solutions of glycerol, 25%, 36%, 43%, 59% and 78% (w/w). The non-Newtonian fluids were aqueous solutions of carboxymethylcellulose (CMC), a polymer, with concentrations of 0.2%, 0.3%, 0.4% and 0.6% (w/w) and aqueous solutions of xanthan gum (XG), another polymer, with concentrations of 0.1% and 0.2% (w/w). According to the rheological study done, the polymer solutions had shear-thinning behavior and different values of viscoelasticity. The helical coil used has an internal diameter, curvature ratio, length and pitch, respectively: 0.00483 m, 0.0263, 5.0 m and 11.34 mm. It was concluded that the friction factors, with simultaneous heat transfer, for Newtonian fluids can be calculated using expressions from literature for isothermal flows. The friction factors for CMC and XG solutions are similar to those for Newtonian fluids when the Dean number, based in a generalized Reynolds number, is less than 80. For Dean numbers higher than 80, the friction factors of the CMC solutions are lower those of the XG solutions and of the Newtonian fluids. In this range the friction factors decrease with the increase of the viscometric component of the solution and increase for increasing elastic component. The change of behavior at Dean number 80, for Newtonian and non-Newtonian fluids, is in accordance with the study of Ali [4]. There is a change of behavior at Dean number 80, for Newtonian and non-Newtonian fluids, which is in according to previous studies. The data also showed that the use of the bulk temperature or of the film temperature to calculate the physical properties of the fluid has a residual effect in the friction factor values.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to carry out experimental work to obtain, for Newtonian and non-Newtonian fluids, heat transfer coefficients, at constant wall temperature as boundary condition, in fully developed laminar flow inside a helical coil. The Newtonian fluids studied were aqueous solutions of glycerol, 25%, 36%, 43%, 59% and 78% (w/w) and the non-Newtonian fluids aqueous solutions of carboxymethylcellulose (CMC), a polymer, with concentrations 0.1%, 0.2%, 0.3%, 0.4% and 0.6% (w/w) and aqueous solutions of xanthan gum (XG), another polymer, with concentrations 0.1% and 0.2% (w/w). According to the rheological study performed, the polymer solutions had shear thinning behavior and different values of elasticity. The helical coil used has internal diameter, curvature ratio, length and pitch, respectively: 0.004575 m, 0.0263, 5.0 m and 11.34 mm. The Nusselt numbers for the CMC solutions are, on average, slightly higher than those for Newtonian fluids, for identical Prandtl and generalized Dean numbers. As outcome, the viscous component of the shear thinning polymer tends to potentiate the mixing effect of the Dean cells. The Nusselt numbers of the XG solutions are significant lower than those of the Newtonian solutions, for identical Prandtl and generalized Dean numbers. Therefore, the elastic component of the polymer tends to diminish the mixing effect of the Dean cells. A global correlation, for Nusselt number as a function of Péclet, generalized Dean and Weissenberg numbers for all Newtonian and non-Newtonian solutions studied, is presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The distinctive characteristics of carbon fibre reinforced plastics, like low weight or high specific strength, had broadened their use to new fields. Due to the need of assembly to structures, machining operations like drilling are frequent. In result of composites inhomogeneity, this operation can lead to different damages that reduce mechanical strength of the parts in the connection area. From these damages, delamination is the most severe. A proper choice of tool and cutting parameters can reduce delamination substantially. In this work the results obtained with five different tool geometries are compared. Conclusions show that the choice of an adequate drill can reduce thrust forces, thus delamination damage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mg alloys are very susceptible to corrosion in physiological media. This behaviour limits its widespread use in biomedical applications as bioresorbable implants, but it can be controlled by applying protective coatings. On one hand, coatings must delay and control the degradation process of the bare alloy and, on the other hand, they must be functional and biocompatible. In this study a biocompatible polycaprolactone (PCL) coating was functionalised with nano hydroxyapatite (HA) particles for enhanced biocompatibility and with an antibiotic, cephalexin, for anti-bacterial purposes and applied on the AZ31 alloy. The chemical composition and the surface morphology of the coated samples, before and after the corrosion tests, were studied by scanning electron microscopy (SEM) coupled with energy dispersive x-ray analysis (EDX) and Raman. The results showed that the presence of additives induced the formation of agglomerates and defects in the coating that resulted in the formation of pores during immersion in Hanks' solution. The corrosion resistance of the coated samples was studied in Hank's solution by electrochemical impedance spectroscopy (EIS). The results evidenced that all the coatings can provide corrosion protection of the bare alloy. However, in the presence of the additives, corrosion protection decreased. The wetting behaviour of the coating was evaluated by the static contact angle method and it was found that the presence of both hydroxyapatite and cephalexin increased the hydrophilic behaviour of the surface. The results showed that it is possible to tailor a composite coating that can store an antibiotic and nano hydroxyapatite particles, while allowing to control the in-vitro corrosion degradation of the bioresorbable Mg alloy AZ31. (C) 2015 Elsevier Ltd. All rights reserved.