989 resultados para Composite Resins


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The success achieved by the use of composite resins in anterior teeth precipitately leads their use in posterior teeth. However, the indiscriminate application of these materials in cavities with several diverse sizes rapidly pointed out their lack of resistance to oclusal and proximal wear. OBJECTIVE: To evaluate the surface roughness of composite resin in relation to finishing and polishing technique. MATERIAL AND METHODS: Eight experimental groups (n = 15) were divided according to finishing and polishing technique: G1 – Z250TM composite resin without surface finishing and polishing; G2 – Z250TM composite resin plus surface finishing and polishing; G3 – P60TM composite resin without surface finishing and polishing; G4 – P60TM composite resin plus surface finishing and polishing; G5 – Prodigy CondensableTM composite resin without surface finishing and polishing; G6 – Prodigy CondensableTM composite resin plus surface finishing and polishing; G7 – SurefillTM composite resin without surface finishing and polishing; G8 – SurefillTM composite resin plus surface finishing and polishing. Three packable and one microhybrid (control group) composite resin was used. The surface roughness was measured using a profilometer at three points in each sample. The results were evaluated by ANOVA and Tukey test (p < 0.05). RESULTS: Prodigy CondensableTM composite resin showed the lowest surface roughness, while SurefillTM showed the highest surface roughness. Comparing the resins used, only between P60TM and SurefillTM there were no statistically significant differences (p > 0,05). CONCLUSION: Surface roughness was lower in all types of resin composites surfaces in contact with Mylar matrix strip than in areas submitted to finishing and polishing procedure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Composite resins are materials that can present color changing when exposed to pigments. Objective: The aim of this study was to evaluate, in vitro, the color changing of composites after immersion in different substances for different periods. Material and methods: Two microhybrid composite resins: Charisma (Heraeus – Kulzer) and Opallis (FGM) were used. Red wine and acai pulp were also used as immersion medium. For this study, 32 specimens with 10 mm of diameter and 2 mm of thickness were used, divided into 4 groups: Group 1 – Opallis composite immersed in red wine solution; Group 2 – Opallis composite immersed in acai berry pulp solution; Group 3 – Charisma composite immersed in red wine solution; Group 4 – Charisma composite immersed in acai berry pulp solution. The specimens were evaluated in the following time periods: T0 – baseline, T1 – 24 hours, T2 – 48 hours, T3 – 72 hours and T4 – 96 hours. For the assessment of staining, a spectrophotometer for colorimetry was used (Color Guide 45 / 0, PCB 6807 BYK-Gardner Gerestsried GmBH, Germany), and the values obtained were transferred to a computer and recorded according to CIELAB system. Results: The data were evaluated using Kruskal- Wallis non-parametric tests with the following mean values for the immersion periods of 24, 48, 72 and 96 hours, respectively: G1 – 7.35, 7.84, 9.04,10.48; G2 – 2.92, 4.15, 4.30, 4.64; G3 – 3.14, 7.35, 8.13, 8.43, G4 – 4.49, 5.99, 6.92, 6.76. Conclusion: Red wine showed a higher tendency toward altering the composite color than acai berry pulp. In addition, no significant difference was found concerning to the behavior of the two composite resins. Concerning to the immersion time periods, significant differences were only observed among the groups in the 24 hour time period.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The human dentition is naturally translucent, opalescent and fluorescent. Differences between the level of fluorescence of tooth structure and restorative materials may result in distinct metameric properties and consequently perceptible disparate esthetic behavior, which impairs the esthetic result of the restorations, frustrating both patients and staff. In this study, we evaluated the level of fluorescence of different composites (Durafill in tones A2 (Du), Charisma in tones A2 (Ch), Venus in tone A2 (Ve), Opallis enamel and dentin in tones A2 (OPD and OPE), Point 4 in tones A2 (P4), Z100 in tones A2 ( Z1), Z250 in tones A2 (Z2), Te-Econom in tones A2 (TE), Tetric Ceram in tones A2 (TC), Tetric Ceram N in tones A1, A2, A4 (TN1, TN2, TN4), Four seasons enamel and dentin in tones A2 (and 4SD 4SE), Empress Direct enamel and dentin in tones A2 (EDE and EDD) and Brilliant in tones A2 (Br)). Cylindrical specimens were prepared, coded and photographed in a standardized manner with a Canon EOS digital camera (400 ISO, 2.8 aperture and 1/ 30 speed), in a dark environment under the action of UV light (25 W). The images were analyzed with the software ScanWhite©-DMC/Darwin systems. The results showed statistical differences between the groups (p < 0.05), and between these same groups and the average fluorescence of the dentition of young (18 to 25 years) and adults (40 to 45 years) taken as control. It can be concluded that: Composites Z100, Z250 (3M ESPE) and Point 4 (Kerr) do not match with the fluorescence of human dentition and the fluorescence of the materials was found to be affected by their own tone.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The composite resin is the material of election for direct restorations in posterior teeth currently. The restorative dentistry aims to improve each day the material and facilitate the restorative technique. This paper describes the technique of occlusal matrix made to speed up and preservation the occlusal surface of a first molar tooth affected by caries lesion. A new resin-based composite was used called Silorane, which may be placed in larger increments due the material has low shrinkage and polymerization stress. The use of occlusal matrix associated with a low shrinkage resin composite can simplify the clinical work, and result in a restoration with excellent reproduction of anatomical.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The authors have studied the effect of four staining agents on the optical properties of esthetic restorative materials through translucency tests. Two commercial brands of composite resins were used: Point 4 (Kerr) and Charisma (Heraeus-Kulzer). The liquids tested were: wine, cola, chlorhexidine solution and nicotine solution. The translucency was measured at different periods of time: P0 – before immersion (baseline), P1 - 1 h after immersion, P2 - 2 h after immersion and successively, P3 – 24 h after immersion up to a period of 7 weeks. ANOVA statistical analysis was applied to the data (p < 0.05). The results lead to the following conclusions: (1) Composite resins submitted to the tested immersion mediums were stained, (2) the lower percentage of translucency was observed for nicotine containing solution, (3) The percentage of translucency decreased with the period of immersion.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: The aim of the study was evaluate the finishing and polishing effect of the color stability of the composite resin Filtek Supreme XT, according to different fluoride solutions and time. Material and Methods: Specimens were prepared (n=140) with half of the samples finished and polished. The experimental groups were divided according to the presence or absence of finishing and polishing and immersion solutions (artificial saliva, sodium fluoride solution at 0.05% - manipulated, Fluordent Reach, Oral B, Fluorgard). The specimens remained in artificial saliva for 24 hours and were subjected to an initial color analysis using a spectrophotometer CIELab system. Then, they were immersed in the experimental solutions for 1 minute a day. The readings of the color change were made after 24 and 48 hours, 7, 14, 21, 30 and 60 days after the first immersion. The three-way mixed Analysis of Variance (ANOVA) ("finishing/polishing", "immersion medium" and “time”) were performed. For multiple comparisons, the Sidak test for repeated measure was used, with a 5% level of significance. Results: The finishing and polishing factor showed significant variability, independently of the immersion media (p<0.001). Cconclusion: Finishing and polishing procedures yielded better color stability to composite resin over time, regardless of the immersion media.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Advanced Layering composite resins can be facilitated by a technique called "Lingual Matrix", where a guide is made of elastomer by molding a previously waxed tooth or sculped in an intraoral test drive restoration. This technique has many advantages to sophisticated layering, facilitation stratification, anatomic construcrion and the stages of finishing and polishing. However, in some clinical situations, the unfolding of the steps to obtains this matrix can be time consuming or even infeasible. To facilitate the achievement of this apparatus, a technique was idealized allowing significant reducrion in clinical time. This matrix, called the "BRB Matrix" is widly discussed in a didactic and clinical manner in this article, presenting its advantages in clinical cases where it is imperative to use a guide for conduction a controlled layering. The simplicity of this approach, as well as reduced clinical time and finacial costs turn it feasible in an everyday clinical practice.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present study aimed to assess the influence of curing distance on the loss of irradiance and power density of four curing light devices. The behavior in terms of power density of four different dental curing devices was analyzed (Valo, Elipar 2, Radii-Cal, and Optilux-401) using three different distances of photopolymerization (0 mm, 4 mm, and 8 mm). All devices had their power density measured using a MARC simulator. Ten measurements were made per device at each distance. The total amount of energy delivered and the required curing time to achieve 16 J/cm2 of energy was also calculated. Data were statistically analyzed with one-way analysis of variance and Tukey’s tests (p < 0.05). The curing distance significantly interfered with the loss of power density for all curing light devices, with the farthest distance generating the lowest power density and consequently the longer time to achieve an energy density of 16 J/cm2 (p < 0.01). Comparison of devices showed that Valo, in extra power mode, showed the best results at all distances, followed by Valo in high power mode, Valo in standard mode, Elipar 2, Radii-Cal, and Optilux-401 halogen lamp (p < 0.01). These findings indicate that all curing lights induced a significant loss of irradiance and total energy when the light was emitted farther from the probe. The Valo device in extra power mode showed the highest power density and the shortest time to achieve an energy density of 16 J/cm2 at all curing distances.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. This study aimed to investigate the surface roughness of composite resins subjected to thermal cycles procedure. Materials and methods. Two microfill, four microhybrid and four nanofill composites were used. The surface roughness (Ra) was initially measured in a profilometer using a cut-off 0f 0.25 mm, after 3000 and 10,000 thermal cycles. Data were subjected to ANOVA and Fischer's test (alpha = 0.05). Results. Overall, 3000 thermal cycles increased the surface roughness values for all materials and there was a trend in all groups to decrease the roughness after 10,000 thermal cycles. Conclusions. The composition of material, including the type of organic matrix, could be more relevant to roughness maintenance over time than the general behavior of composites based on particles fillers. The maintenance of smooth surface in resin-based composite restorations is totally dependent of organic composition of the material.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recent bonding systems have been advocated as multi-purpose bonding agents. The aim of this study was to determine if some of these bonding systems could be associated to composite resins from different manufacturers. This investigation was conducted to test lhe shear bond strength of three bonding systems: Scotchbond Multi-Purpose (3M Dental Products), Optibond Light Cure (Kerr) and Optibond Dual Cure (Kerr), when each of them was associated to lhe composite resins: Z1 00 (3M Dental Products), Prisma - APH (Dentsply) and Herculite XRV (Kerr). Seventy-two flat dentin bonding sites were prepared to 600 grit on human premolars mounted using acrilic resins. The teeth were assigned at random to 9 groups of 8 samples each. A split die with a 3mm diameter was placed over lhe surface of lhe dentin treated with one of lhe adhesive systems, and lhe selected composite resin was inserted and light cured. The split mold was removed and all samples were termocycled and stored in 37ºC water for 24 hours before testing. Shear bond strength was determined using an lnstron Universal testing machine. Some failures were examined under lhe S.E.M. Data was analysed by one-way analysis of variance, that demonstrated a significant difference (p<0,05) in the mean shear bond strength among Optibond Light Cure (15,446 MPa), Scotchbond Multi-Purpose (13,339 MPa) and Optibond Dual Cure (10,019 MPa). These values did not depend on the composite resin used. The association between bonding system/composite resin was statistycally significant (p<0,05) and the best results were obtained when the composite resins Z100 and Herculite were used with the adhesive system Optibond Light Cure, and when the composite resin APH was used with the adhesive system Scotchbond Multi-Purpose

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To evaluate the volumetric changes due to polymerization and thermocycling on different resin-composites. Methods: Thirteen A2 Universal Dentin shade resin-composites (n = 10) from eight manufacturers were evaluated (4Seasons, Grandio, Venus, Amelogen Plus, P90, Z350, Esthet-X, Amaris, Vita-l-escence, Natural-Look, Charisma, Z250 and Opallis). The polymerization shrinkage percentage (PS) was calculated using an image measurement device (ACUVOL - Bisco Dental). Equal volumes of material, standardized by a semisphere polyurethane matrix (d = 3mm) were used and, after 5 minutes of relaxation, the baseline volume measurements were obtained with 18 J of energy dose from the LED light-curing unit. Measurements were obtained after 5 minutes and PS values calculated. Specimens were stored in a drydark environment for 24 hours and re-measured. Specimens were then thermocycled in distilled water between 5oC and 55oC for 20,000 cycles, subjected to another volume measurement at 5,000 cycle intervals. Specimens were gently dried prior to each measurement. Results: Repeated measurements were made using ANOVA (α = 0.05) showed that all resin-composite volumes were influenced by the number of cycles. Volumes at 5 minutes post-polymerization (12.47 ± 0.08) were significantly lower than those at baseline (12.80 ± 0.09). Volumes at 24 hours (12.43 ± 0.19) were insignificantly lower than those at 5 minutes postpolymerization. With regards to the impact of thermocycling, all specimens showed statistically significant increases in volume after 5,000 cycles (13.04 ± 0.22). Although statistically different from those after 5,000 cycles, there was no statistically significant difference between volumes measured at 10,000 (12.87±0.21), 15,000 (12.92±0.24), and 20,000 (12.84±0.23) cycles. Conclusion: According to the video-imaging analysis, thermocycling caused a significant expansion in resin-composites tested, the volume increase was not able to...