962 resultados para CC BOND
Resumo:
The purpose of the study was to evaluate the shear bond strength of stainless steel orthodontic brackets directly bonded to extracted human premolar teeth. Fifty teeth were randomly divided into ¿ve groups: (1) System One (chemically cured composite resin), (2) Light Bond (light-cured composite resin), (3) Vivaglass Cem (self-curing glass ionomer cement), (4) Fuji Ortho LC (light-cured glass ionomer cement) used after 37% orthophosphoric acid¿etching of enamel (5) Fuji Ortho LC without orthophosphoric acid¿etching. The brackets were placed on the buccal and lingual surfaces of each tooth, and the specimens were stored in distilled water (24 hours) at 378C and thermocycled. Teeth were mounted on acrylic block frames, and brackets were debonded using an Instron machine. Shear bond strength values at fracture (Nw)were recorded. ANOVA and Student-Newman-Keuls multiple comparison tests were performed (P , .05). Bonding failure site was recorded by stereomicroscope and analyzed by Chi-square test, selected specimens of each group were observed by scanning electron microscope. System One attained the highest bond strength. Light Bond and Fuji Ortho LC, when using an acid-etching technique, obtained bond strengths that were within the range of estimated bond strength values for successful clinical bonding. Fuji Ortho LC and Vivaglass Cem left an almost clean enamel surface after debracketing.
Resumo:
In reinforced concrete systems, ensuring that a good bond between the concrete and the embedded reinforcing steel is critical to long-term structural performance. Without good bond between the two, the system simply cannot behave as intended. The bond strength of reinforcing bars is a complex interaction between localized deformations, chemical adhesion, and other factors. Coating of reinforcing bars, although sometimes debated, has been commonly found to be an effective way to delay the initiation of corrosion in reinforced concrete systems. For many years, the standard practice has been to coat reinforcing steel with an epoxy coating, which provides a barrier between the steel and the corrosive elements of water, air, and chloride ions. Recently, there has been an industry-led effort to use galvanizing to provide the protective barrier commonly provided by traditional epoxy coatings. However, as with any new structural product, questions exist regarding both the structural performance and corrosion resistance of the system. In the fall of 2013, Buchanan County, Iowa constructed a demonstration bridge in which the steel girders and all internal reinforcing steel were galvanized. The work completed in this project sought to understand the structural performance of galvanized reinforcing steel as compared to epoxy-coated steel and to initiate a long-term corrosion monitoring program. This work consisted of a series of controlled laboratory tests and the installation of a corrosion monitoring system that can be observed for years in the future. The results of this work indicate there is no appreciable difference between the bond strength of epoxy-coated reinforcing steel and galvanized reinforcing steel. Although some differences were observed, no notable difference in either peak load, slip, or failure mode could be identified. Additionally, a long-term monitoring system was installed in this Buchanan County bridge and, to date, no corrosion activity has been identified.
Resumo:
The distribution of distances from atoms of a particular element E to a probe atom X (oxygen in most cases), both bonded and intermolecular non-bonded contacts, has been analyzed. In general, the distribution is characterized by a maximum at short EX distances corresponding to chemical bonds, followed by a range of unpopulated distances the van der Waals gap and a second maximum at longer distances the van der Waals peak superimposed on a random distribution function that roughly follows a d3 dependence. The analysis of more than five million interatomic"non-bonded" distances has led to the proposal of a consistent set of van der Waals radii for most naturally occurring elements, and its applicability to other element pairs has been tested for a set of more than three million data, all of them compared to over one million bond distances.
Bond Contribution to Whitetopping Performance on Low Volume Roads, Construction Report, HR-341, 1993
Resumo:
This research was initiated in 1991 as a part of a whitetopping project to study the effectiveness of various techniques to enhance bond strength between a new Portland cement concrete (PCC) overlay and an existing asphalt cement concrete (ACC) pavement surface. A 1,676 m (5,500 ft) section of county road R16 in Dallas County, Iowa was divided into 12 test sections. The various techniques used to enhance bond were power brooming, power brooming with air blast, milling, cement and water grout, and emulsion tack coat. As a part of these bonding techniques, two pavement thicknesses were placed; two different concrete proportions were used; and two sections were planed to a uniform cross-slope.
Resumo:
Objectives: To evaluate the shear bond strength and site of failure of brackets bonded to dry and wet enamel. Study design: 50 teeth were divided into ten groups of 5 teeth each (10 surfaces). In half the groups enamel was kept dry before bonding, and in the other half distilled water was applied to wet the surface after etching. The following groups were established: 1)Acid/Transbond-XT (dry/wet) XT; 2) Transbond Plus Self Etching Primer (TSEP)/Transbond-XT paste (dry/wet); 3) Concise (dry), Transbond MIP/Concise (wet), 4) FujiOrtho-LC (dry/wet); 5) SmartBond (dry/wet). Brackets were bonded to both buccal and lingual surfaces. Specimens were stored in distilled water (24 hours at 37ºC) and thermocycled. Brackets were debonded using a Universal testing machine (cross-head speed 1 mm/min). Failure sites were classified using a stereomicroscope. Results: No significant differences in bond strength were detected between the adhesives under wet and dry conditions except for Smart- Bond, whose bond strength was significantly lower under dry conditions. For all the adhesives most bond failures were of mixed site location except for Smartbond, which failed at the adhesive-bracket interface. Conclusions: Under wet conditions the bonding capacity of the adhesives tested was similar than under dry conditions, with the exception of SmartBond which improved under wet conditions
Resumo:
The present study tests the relationships between the three frequently used personality models evaluated by the Temperament Character Inventory-Revised (TCI-R), Neuroticism Extraversion Openness Five Factor Inventory – Revised (NEO-FFI-R) and Zuckerman-Kuhlman Personality Questionnaire-50- Cross-Cultural (ZKPQ-50-CC). The results were obtained with a sample of 928 volunteer subjects from the general population aged between 17 and 28 years old. Frequency distributions and alpha reliabilities with the three instruments were acceptable. Correlational and factorial analyses showed that several scales in the three instruments share an appreciable amount of common variance. Five factors emerged from principal components analysis. The first factor was integrated by A (Agreeableness), Co (Cooperativeness) and Agg-Host (Aggressiveness-Hostility), with secondary loadings in C (Conscientiousness) and SD (Self-directiveness) from other factors. The second factor was composed by N (Neuroticism), N-Anx (Neuroticism-Anxiety), HA (Harm Avoidance) and SD (Self-directiveness). The third factor was integrated by Sy (Sociability), E (Extraversion), RD (Reward Dependence), ImpSS (Impulsive Sensation Seeking) and NS (novelty Seeking). The fourth factor was integrated by Ps (Persistence), Act (Activity), and C, whereas the fifth and last factor was composed by O (Openness) and ST (Self- Transcendence). Confirmatory factor analyses indicate that the scales in each model are highly interrelated and define the specified latent dimension well. Similarities and differences between these three instruments are further discussed.
Resumo:
OBJECTIVE: To evaluate the variability of bond strength test results of adhesive systems (AS) and to correlate the results with clinical parameters of clinical studies investigating cervical restorations. MATERIALS AND METHODS: Regarding the clinical studies, the internal database which had previously been used for a meta-analysis on cervical restorations was updated with clinical studies published between 2008 and 2012 by searching the PubMed and SCOPUS databases. PubMed and the International Association for Dental Research abstracts online were searched for laboratory studies on microtensile, macrotensile and macroshear bond strength tests. The inclusion criteria were (1) dentin, (2) testing of at least four adhesive systems, (3) same diameter of composite and (4) 24h of water storage prior to testing. The clinical outcome variables were retention loss, marginal discoloration, detectable margins, and a clinical index comprising the three parameters by weighing them. Linear mixed models which included a random study effect were calculated for both, the laboratory and the clinical studies. The variability was assessed by calculating a ratio of variances, dividing the variance among the estimated bonding effects obtained in the linear mixed models by the sum of all variance components estimated in these models. RESULTS: Thirty-two laboratory studies fulfilled the inclusion criteria comprising 183 experiments. Of those, 86 used the microtensile test evaluating 22 adhesive systems (AS). Twenty-seven used the macrotensile test with 17 AS, and 70 used the macroshear test with 24 AS. For 28 AS the results from clinical studies were available. Microtensile and macrotensile (Spearman rho=0.66, p=0.007) were moderately correlated and also microtensile and macroshear (Spearman rho=0.51, p=0.03) but not macroshear and macrotensile (Spearman rho=0.34, p=0.22). The effect of the adhesive system was significant for microtensile and macroshear (p<0.001) but not for macrotensile. The effect of the adhesive system could explain 36% of the variability of the microtensile test, 27% of the macrotensile and 33% of the macroshear test. For the clinical trials, about 49% of the variability of retained restorations could be explained by the adhesive system. With respect to the correlation between bond strength tests and clinical parameters, only a moderate correlation between micro- and macrotensile test results and marginal discoloration was demonstrated. However, no correlation between these tests and a retention loss or marginal integrity was shown. The correlation improved when more studies were included compared to assessing only one study. SIGNIFICANCE: The high variability of bond strength test results highlights the need to establish individual acceptance levels for a given test institute. The weak correlation of bond-strength test results with clinical parameters leads to the conclusion that one should not rely solely on bond strength tests to predict the clinical performance of an adhesive system but one should conduct other laboratory tests like tests on the marginal adaptation of fillings in extracted teeth and the retention loss of restorations in non-retentive cavities after artificial aging.
Resumo:
We empirically investigate whether the transmission of the recent crisis in euro area sovereign debt markets was due to fundamentals-based or pure contagion. To do so, we examine the behaviour of EMU sovereign bond yield spreads with respect to the German bund for a sample of both central and peripheral countries from January 1999 to December 2012. First we apply a dynamic approach to analyse the evolution of the degree of Grangercausality within the 90 pairs of sovereign bond yield spreads in our sample, in order to detect episodes of significantly increased causality between them (which we associate with contagion) and episodes of significantly reduced interconnection (which we associate with immunisation). We then use an ordered logit model to assess the determinants of the occurrence of the episodes detected. Our results suggest the importance of variables proxying market sentiment and of variables proxying macrofundamentals in determining contagion and immunisation outcomes. Therefore, our findings underline the coexistence of “pure” and “fundamentals-based contagion” during the recent European debt crisis.
Resumo:
We empirically investigate whether the transmission of the recent crisis in euro area sovereign debt markets was due to fundamentals-based or pure contagion. To do so, we examine the behaviour of EMU sovereign bond yield spreads with respect to the German bund for a sample of both central and peripheral countries from January 1999 to December 2012. First we apply a dynamic approach to analyse the evolution of the degree of Grangercausality within the 90 pairs of sovereign bond yield spreads in our sample, in order to detect episodes of significantly increased causality between them (which we associate with contagion) and episodes of significantly reduced interconnection (which we associate with immunisation). We then use an ordered logit model to assess the determinants of the occurrence of the episodes detected. Our results suggest the importance of variables proxying market sentiment and of variables proxying macrofundamentals in determining contagion and immunisation outcomes. Therefore, our findings underline the coexistence of “pure” and “fundamentals-based contagion” during the recent European debt crisis.