911 resultados para Blood Alcohol Test Equipment.


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Investigations of the factor structure of the Alcohol Use Disorders Identification Test (AUDIT) have produced conflicting results. The current study assessed the factor structure of the AUDIT for a group of Mentally Disordered Offenders (MDOs) and examined the pattern of scoring in specific subgroups. The sample comprised 2005 MDOs who completed a battery of tests including the AUDIT. Confirmatory factor analyses revealed that a two-factor solution – alcohol consumption and alcohol-related consequences – provided the best data fit for AUDIT scores. A three-factor solution provided an equally good fit, but the second and third factors were highly correlated and a measure of parsimony also favoured the two-factor solution. This study provides useful information on the factor structure of the AUDIT amongst a large MDO population, while also highlighting the difficulties associated with the presence of people with mental health problems in the criminal justice system.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

When a subject is heated, the stimulation of temperature-sensitive nerve endings in the skin, and the raising of the central body temperature, results in the reflex release of sympathetic vasoconstrictor tone in the skin of the extremities, causing a measurable temperature increase at the site of release. In the sympathetic release test, the subject is gently heated by placing the feet and calves in a commercially available foot warming pouch or immersing the feet and calves in warm water and wrapping the subject in blankets. Skin blood flow is estimated from measurements of skin temperature in the fingers. Normally skin temperature of the fingers is 65-75 degrees F in cool conditions (environmental temperature: 59-68 degrees F) and rises to 85-95 degrees F during body heating. Deviations in this pattern may mean that there is abnormal sympathetic vasoconstrictor control of skin blood flow. Abnormal skin blood flow can substantially impair an individual's ability to thermoregulate and has important clinical implications. During whole body heating, the skin temperature from three different skin sites is monitored and oral temperature is monitored as an index of core temperature. Students determine the fingertip temperature at which the reflex release of sympathetic activity occurs and its maximal attainment, which reflects the vasodilating capacity of this cutaneous vascular bed. Students should interpret typical sample data for certain clinical conditions (Raynaud's disease, peripheral vascular disease, and postsympathectomy) and explain why there may be altered skin blood flow in these disorders.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: The Finometer (FMS, Finapres Measurement Systems, Amsterdam) records the beat-to-beat finger pulse contour and has been recommended for research studies assessing shortterm changes of blood pressure and its variability. Variability measured in the frequency domain using spectral analysis requires that the impact of breathing be restricted to high frequency spectra (> 0.15 Hz) so data from participants needs to be excluded when the breathing impact occurs in the low frequency spectra (0.04 - 0.15 Hz). This study tested whether breathing frequency can be estimated from standard Finometer recordings using either stroke volume oscillation frequency or spectral stroke volume variability maximum scores. Methods: 22 healthy volunteers were tested for 270s in the supine and upright positions. Finometer recorded the finger pulse contour and a respiratory transducer recorded breathing. Stoke volume oscillation frequency was calculated manually while the stroke volume spectral maximums were obtained using the software Cardiovascular Parameter Analysis (Nevrokard Kiauta, Izola, Slovenia). These estimates were compared to the breathing frequency using the Bland-Altman procedures. Results: Stroke volume oscillation frequency estimated breathing frequency to <±10% 95% levels of agreement in both supine (-7.7 to 7.0%) and upright (-6.7 to 5.4%) postures. Stroke volume variability maximum scores did not accurately estimate breathing frequency. Conclusions: Breathing frequency can be accurately derived from standard Finometer recordings using stroke volume oscillations for healthy individuals in both supine and upright postures. The Finometer can function as a standalone instrument in blood pressure variability studies and does not require support equipment to determine breathing frequency.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Resumen tomado de la publicaci??n

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Blood clotting response (BCR) resistance tests are available for a number of anticoagulant rodenticides. However, during the development of these tests many of the test parameters have been changed, making meaningful comparisons between results difficult. It was recognised that a standard methodology was urgently required for future BCR resistance tests and, accordingly, this document presents a reappraisal of published tests, and proposes a standard protocol for future use (see Appendix). The protocol can be used to provide information on the incidence and degree of resistance in a particular rodent population; to provide a simple comparison of resistance factors between active ingredients, thus giving clear information about cross-resistance for any given strain; and to provide comparisons of susceptibility or resistance between different populations. The methodology has a sound statistical basis in being based on the ED50 response, and requires many fewer animals than the resistance tests in current use. Most importantly, tests can be used to give a clear indication of the likely practical impact of the resistance on field efficacy. The present study was commissioned and funded by the Rodenticide Resistance Action Committee (RRAC) of CropLife International.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Issue addressed: There is accumulating evidence supporting a link between alcohol industry sponsorship and alcohol-related problems in both community and elite-level sports. Little is known, however, about the current status of such sponsorship, particularly of community sport. This study aimed to assess associations between alcohol industry sponsorship and different community football clubs in Australia.

Methods: The study involved 101 community football clubs across New South Wales, Australia. One representative from each club took part in a cross-sectional telephone survey designed to assess club (football code, number of players, socioeconomic and geographic descriptors) and alcohol industry sponsorship (money, equipment, free alcohol or discounted alcohol) characteristics. Chi-square analysis was used to test associations between club characteristics, and: i) any alcohol industry sponsorship; and ii) type of sponsorship.

Results: Eighty-eight per cent of clubs reported receiving sponsorship from the alcohol industry, and most clubs (82%) were sponsored by a licensed premises. There were no significant associations between club characteristics and source of alcohol industry sponsorship. However, small clubs were found to be significantly more likely to receive free or discounted alcohol sponsorship than larger clubs (p=0.05).

Conclusions: This exploratory study suggests a significant presence of alcohol industry sponsorship among community football clubs in Australia.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Determinou-se, em eqüinos, o efeito do treinamento sobre as concentrações sangüíneas de lactato e plasmáticas de glicose durante exercício de intensidade progressiva em esteira rolante. Demonstrou-se que o treinamento aeróbico causou diminuição da concentração máxima de lactato e que o limiar de lactato corresponde ao ponto de inflexão da curva de glicose plasmática, confirmando esse parâmetro como indicador da capacidade aeróbica de cavalos.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Tegtbur et al. [23] devised a new method able to estimate the intensity at maximal lactate steady state termed lactate minimum test. According to Billat et al. [7], no studies have yet been published on the affect of training on highest blood lactate concentration that can be maintained over time without continual blood lactate accumulation. Therefore, the aim of the present study was to verify the effect of soccer training on the running speed and the blood lactate concentration (BLC) at the lactate minimum test (Lac(min)). Thirteen Brazilian male professional soccer players, all members of the same team playing at National level, volunteered for this study. Measurements were carried out before (pre) and after (post) eight weeks of soccer training. The Lac(min) test was adapted to the procedures reported by Tegtbur et al. [23]. The running speed at the Lac(min) test was taken when the gradient of the line was zero. Differences in running speed and blood lactate concentration at the Lac(min) test before (pre) and after (post) the training program were evaluated by Student's paired t-test. The training program increased the running speed at the Lac(min) test (14.94 +/- 0.21 vs. 15.44 +/- 0.42* km(.)h(-1)) and the blood lactate concentration (5.11 +/- 2.31 vs. 6.93 +/- 1.33* mmol(.)L(-1)). The enhance in the blood lactate concentration may be explained by an increase in the lactate/H+ transport capacity of human skeletal muscle verified by other authors.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Desinfecção de superfície é um procedimento realizado nas áreas externas do equipamento odontológico e demais itens do consultório. O objetivo deste trabalho foi analisar a ação de quatro desinfetantes utilizados em Odontologia: álcool etílico a 77°GL, composto fenólico (Duplofen), iodóforo (PVP-I) e solução de álcool etílico a 77°GL com 5% de clorexidina para desinfecção de superfície. Foram analisados quatro pontos em cada equipamento (carter, pia de lavagem de mãos, encosto de cabeça da cadeira e superfície frontal externa do refletor), utilizando-se a técnica de spray-wipe-spray. de cada ponto, foram coletadas amostras utilizando-se placas de superfície contendo ágar Mitis Salivarius bacitracina sacarose, ágar Sabouraud Dextrose com cloranfenicol, ágar MacConkey e ágar-sangue para contagem de estreptococos do grupo mutans, leveduras do gênero Candida, bactérias gram-negativas e contagem total de microrganismos, respectivamente (ufc/placa). Os resultados foram analisados estatisticamente utilizando-se teste t de Student para comparação entre as médias de ufc/placa. O desinfetante que demonstrou ser mais efetivo na redução microbiana foi a solução alcoólica de clorexidina, principalmente para bactérias gram-positivas. O iodo e o composto fenólico mostraram ser bastante eficazes na redução microbiana. O álcool etílico a 77°GL foi o menos eficaz dos quatro desinfetantes analisados, mas apesar de não ser indicado como desinfetante de superfície, mostrou, no presente trabalho, redução microbiana estatisticamente significativa após o processo de desinfecção.