393 resultados para Autopsy.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe the unique autopsy findings of a patient who died of a metastasizing giant right atrial adenocarcinoma containing few areas of typical myxoma. That no mucin-producing extracardiac tumor was detected pointed to the atrial adenocarcinoma as being the primary. We hypothesize that the adenocarcinoma may have developed from coexistent bland glandular structures within the myxoma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Human rabies is rare in Western Europe. It is not easily recognized in the absence of a history of exposure. We describe the clinical course, diagnosis and follow-up of an imported human rabies case in Switzerland. The patient, a U.S. citizen, presented at an outpatient clinic in Iraq with pain in his right shoulder on July 5, 2012. On July 8 he was transferred to a hospital in the United Arab Emirates, where he exhibited progressive encephalitis with coma. On July 29, he was transferred to a hospital in Switzerland, where he died on July 31, 2012. The autopsy showed severe encephalitis. Rabies was diagnosed by the rapid fluorescent focus inhibition test (RFFIT) and confirmed by fluorescence antibody testing (FAT) in brain smears and immunohistochemistry on paraffin-embedded brain sections. The viral strain was characterized by RT-PCR followed by sequencing and phylogenetic analysis as an American bat rabies strain associated with Tadarida brasiliensis. Close contacts and exposed health care workers received postexposure prophylaxis (PEP).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to investigate if acute myocardial infarction can be detected by post-mortem cardiac magnetic resonance (PMMR) at an earlier stage than by traditional autopsy, i.e., within less than 4 h after onset of ischemia; and if so, to determine the characteristics of PMMR findings in early acute infarcts. Twenty-one ex vivo porcine hearts with acute myocardial infarction underwent T2-weighted cardiac PMMR imaging within 3 h of onset of iatrogenic ischemia. PMMR imaging findings were compared to macroscopic findings. Myocardial edema induced by ischemia and reperfusion was visible on PMMR in all cases. Typical findings of early acute ischemic injury on PMMR consist of a central zone of intermediate signal intensity bordered by a rim of increased signal intensity. Myocardial edema can be detected on cardiac PMMR within the first 3 h after the onset of ischemia in porcine hearts. The size of myocardial edema reflects the area of ischemic injury in early acute (per-acute) myocardial infarction. This study provides evidence that cardiac PMMR is able to detect acute myocardial infarcts at an earlier stage than traditional autopsy and routine histology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rosette-forming glioneuronal tumor (RGNT) is a recently introduced, indolent neoplasm composed of diminutive circular aggregates of neurocytic-like cells on a noninfiltrative astrocytic background, typically located in the cerebellar midline The traded concept of RGNT being derived from site-specific periventricular precursors may be questioned in the face of extracerebellar examples as well as ones occurring in combination with other representatives of the glioneuronal family. We describe a hitherto not documented example of asymptomatic RGNT discovered during autopsy of a 74-year-old male. Located in the tuberal vermis, this lesion of 6 mm diameter consisted of several microscopic nests of what were felt to represent nascent stages of RGNT, all of them centered on the internal granular layer, and ranging from mucoid dehiscences thereof to fully evolved - if small - tumor foci. Molecular genetic analysis revealed a missense mutation in Exon 20 of the PIK3CA gene involving an A→G transition at Nucleotide 3140. On the other hand, neither codeletion of chromosomes 1p/19q nor pathogenic mutations of IDH1/2 were detected. By analogy with in situ paradigms in other organs, we propose that this tumor is likely to have arisen from the internal granular layer, rather than the plate of the 4th ventricle. A suggestive departure from the wholesale argument of "undifferentiated precursors", this finding also indirectly indicates that a subset of non-classical RGNTs - in particular extracerebellar examples, whose origin cannot be mechanistically accounted for by either of the above structures - may possibly reflect an instance of phenotypic convergence, rather than a lineage-restricted entity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Postprimary tuberculosis occurs in immunocompetent people infected with Mycobacterium tuberculosis. It is restricted to the lung and accounts for 80% of cases and nearly 100% of transmission. Little is known about the immunopathology of postprimary tuberculosis due to limited availability of specimens. Tissues from 30 autopsy cases of pulmonary tuberculosis were located. Sections of characteristic lesions of caseating granulomas, lipid pneumonia, and cavitary stages of postprimary disease were selected for immunohistochemical studies of macrophages, lymphocytes, endothelial cells, and mycobacterial antigens. A higher percentage of cells in lipid pneumonia (36.1%) and cavitary lesions (27.8%) were positive for the dendritic cell marker DEC-205, compared to granulomas (9.0%, P < .05). Cavities contained significantly more T-regulatory cells (14.8%) than found in lipid pneumonia (5.2%) or granulomas (4.8%). Distribution of the immune cell types may contribute to the inability of the immune system to eradicate tuberculosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to determine if area measurements of pleural fluid on computed tomography (CT) reflect the actual pleural fluid volume (PEvol) as measured at autopsy, to establish a formula to estimate the volume of pleural effusion (PEest), and to test the accuracy and observer reliability of PEest.132 human cadavers, with pleural effusion were divided into phase 1 (n = 32) and phase 2 (n = 100). In phase 1, PEvol was compared to area measurements on axial (axA), sagittal (sagA), and coronal (corA) CT images. Linear regression analysis was used to create a formula to calculate PEest. In phase 2, intra-class correlation (ICC) was used to assess inter-reader reliability and determine the agreement between PEest and PEvol. PEvol correlated to a higher degree to axA (r s mean = 0.738; p < 0.001) than to sagA (r s mean = 0.679, p < 0.001) and corA (r s mean = 0.709; p < 0.001). PEest can be established with the following formula: axA × 0.1 = PEest. Mean difference between PEest and PEvol was less than 40 mL (ICC = 0.837-0.874; p < 0.001). Inter-reader reliability was higher between two experienced readers (ICC = 0.984-0.987; p < 0.001) than between an inexperienced reader and both experienced readers (ICC = 0.660-0.698; p < 0.001). Pleural effusions may be quantified in a rapid, reliable, and reasonably accurate fashion using single area measurements on CT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cardiovascular magnetization transfer ratio (MTR) imaging by steady state free precession is a promising imaging method to assess microstructural changes within the myocardium. Hence, MTR imaging was correlated to histological analysis. Three postmortem cases were selected based on a suspicion of myocardial infarction. MTR and T2 -weighted (T2w ) imaging was performed, followed by autopsy and histological analysis. All tissue abnormalities, identified by autopsy or histology, were retrospectively selected on visually matched MTR and T2w images, and corresponding MTR values compared with normal appearing tissue. Regions of elevated MTR (up to approximately 20%, as compared to normal tissue), appearing hypo-intense in T2w -images, revealed the presence of fibrous tissue in microscopic histological analysis. Macroscopic observation (autopsy) described scar tissue only in one case. Regions of reduced MTR (up to approximately 20%) corresponded either to (i) the presence of edema, appearing hyperintense in T2w -images and confirmed by autopsy, or to (ii) inflammatory granulocyte infiltration at a microscopic level, appearing as hypo-intense T2w -signal, but not observed by autopsy. Findings from cardiovascular MTR imaging corresponded to histology results. In contrast to T2w -imaging, MTR imaging discriminated between normal myocardium, scar tissue and regions of acute myocardial infarction in all three cases. J. Magn. Reson. Imaging 2013. © 2013 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE The aim of this work is to investigate and compare cardiac proton density (PD) weighted fast field echo (FFE) post-mortem magnetic resonance (PMMR) imaging with standard cardiac PMMR imaging (T1-weighted and T2-weighted turbo spin-echo (TSE)), postmortem CT (PMCT) as well as autopsy. MATERIALS AND METHODS Two human cadavers sequentially underwent cardiac PMCT and PMMR imaging (PD-weighted FFE, T1-weighted and T2-weighted TSE) and autopsy. The cardiac PMMR images were compared to each other as well as to PMCT and autopsy findings. RESULTS For the first case, cardiac PMMR exhibited a focal region of low signal in PD-weighted FFE and T2-weighted TSE images, surrounded by a signal intense rim in the T2-weighted images. T1-weighted TSE and PMCT did not appear to identify any focal abnormality. Macroscopic inspection identified a blood clot; histology confirmed this to be a thrombus with an adhering myocardial infarction. In the second case, a myocardial rupture with heart tamponade was identified in all PMMR images, located at the anterior wall of the left ventricle; PMCT excluded additional ruptures. In PD-weighted FFE and T2-weighted TSE images, it occurred hypo-intense, while resulting in small clustered hyper-intense spots in T1-weighted TSE. Autopsy confirmed the PMMR and PMCT findings. CONCLUSIONS Presented initial results have shown PD-weighted FFE to be a valuable imaging sequence in addition to traditional T2-weighted TSE imaging for blood clots and myocardial haemorrhage with clearer contrast between affected and healthy myocardium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Instillation of contrast medium into stab wounds has shown promising results regarding visibility and assessment of general stab direction with computed tomography. However, the accuracy of this method--and, incidentally also probing of stab wounds--has to our knowledge not previously been examined. Also the effect of bluntness of different stabbing objects on the examination of stab wounds was not considered before this study. METHODS Using a pocket-knife, a steak-knife, and a Phillips screwdriver, nine stab wounds each were inflicted to three pork haunches. The depths of the stab wounds were determined by probing and multislice computed tomography (MSCT) after instillation of a contrast medium (CM) and then compared to those observed by dissection, our internal "gold standard". RESULTS In stab wounds inflicted by knives, MSCT-CM and probing provided results which differed by roughly 10-11% from the dissection results. In screwdriver stabs MSCT-CM showed a deviation of almost 30%, probing over 33%. DISCUSSION MSCT-CM is a possible alternative to layer-by-layer dissection in autopsy cases of knife stab wounds. Probing, although obsolete in post-mortem examinations, is sufficiently accurate in determining the length of a stab wound of a living person. In cases of stab wounds with blunt objects such as screwdrivers, neither MSCT-CM nor probing proved to be sufficiently accurate. CONCLUSION MSCT-CM is a possible alternative to layer-by-layer dissection in autopsy cases of knife stab wounds. Probing, although obsolete in post-mortem examinations, is sufficiently accurate in determining the length of a stab wound of a living person. In cases of stab wounds with blunt objects such as screwdrivers, neither MSCT-CM nor probing proved to be sufficiently accurate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the reliability of the cardiothoracic ratio (CTR) in postmortem computed tomography (PMCT) and to assess a CTR threshold for the diagnosis of cardiomegaly based on the weight of the heart at autopsy. PMCT data of 170 deceased human adults were retrospectively evaluated by two blinded radiologists. The CTR was measured on axial computed tomography images and the actual cardiac weight was weighed at autopsy. Inter-rater reliability, sensitivity, and specificity were calculated. Receiver operating characteristic curves were calculated to assess enlarged heart weight by CTR. The autopsy definition of cardiomegaly was based on normal values of the Zeek method (within a range of both, one or two SD) and the Smith method (within the given range). Intra-class correlation coefficients demonstrated excellent agreements (0.983) regarding CTR measurements. In 105/170 (62 %) cases the CTR in PMCT was >0.5, indicating enlarged heart weight, according to clinical references. The mean heart weight measured in autopsy was 405 ± 105 g. As a result, 114/170 (67 %) cases were interpreted as having enlarged heart weights according to the normal values of Zeek within one SD, while 97/170 (57 %) were within two SD. 100/170 (59 %) were assessed as enlarged according to Smith's normal values. The sensitivity/specificity of the 0.5 cut-off of the CTR for the diagnosis of enlarged heart weight was 78/71 % (Zeek one SD), 74/55 % (Zeek two SD), and 76/59 % (Smith), respectively. The discriminative power between normal heart weight and cardiomegaly was 79, 73, and 74 % for the Zeek (1SD/2SD) and Smith methods respectively. Changing the CTR threshold to 0.57 resulted in a minimum specificity of 95 % for all three definitions of cardiomegaly. With a CTR threshold of 0.57, cardiomegaly can be identified with a very high specificity. This may be useful if PMCT is used by forensic pathologists as a screening tool for medico-legal autopsies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a case where multi-phase post-mortem computed tomography angiography (PMCTA) induced a hemorrhagic pericardial effusion during the venous phase of angiography. Post-mortem non-contrast CT (PMCT) suggested the presence of a ruptured aortic dissection. This diagnosis was confirmed by PMCTA after pressure controlled arterial injection of contrast. During the second phase of multi-phase PMCTA the presence of contrast leakage from the inferior cava vein into the pericardial sac was noted. Autopsy confirmed the post-mortem nature of this vascular tear. This case teaches us an important lesson: it underlines the necessity to critically analyze PMCT and PMCTA images in order to distinguish between artifacts, true pathologies and iatrogenic findings. In cases with ambiguous findings such as the case reported here, correlation of imaging findings with autopsy is elementary.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a case of a ruptured abdominal aortic aneurysm (AAA) with ambiguous accessory findings on post-mortem computed-tomography (PMCT), post-mortem magnetic resonance (PMMR) imaging, and PMCT-angiography (PMCTA) suggestive of thoracic aortic dissection. The diagnosis of ruptured AAA was confirmed by autopsy; however, there was no aortic dissection. The imaging findings that mimicked the presence of aortic dissection might have been an atypical presentation of post-mortem clotting or sedimentation. This case is an ideal example to illustrate benefits, limitations, and challenges of post-mortem cross-sectional imaging. It serves as a reminder that both, training as well as correlation of imaging findings with autopsy are fundamental to improve our understanding of radiologic findings on post-mortem cross-sectional imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pneumococcal meningitis (PM) results in high mortality rates and long-lasting neurological deficits. Hippocampal apoptosis and cortical necrosis are histopathological correlates of neurofunctional sequelae in rodent models and are frequently observed in autopsy studies of patients who die of PM. In experimental PM, inhibition of matrix metalloproteinases (MMPs) and/or tumor necrosis factor (TNF)-converting enzyme (TACE) has been shown to reduce brain injury and the associated impairment of neurocognitive function. However, none of the compounds evaluated in these studies entered clinical development. Here, we evaluated two second-generation MMP and TACE inhibitors with higher selectivity and improved oral availability. Ro 32-3555 (Trocade, cipemastat) preferentially inhibits collagenases (MMP-1, -8, and -13) and gelatinase B (MMP-9), while Ro 32-7315 is an efficient inhibitor of TACE. PM was induced in infant rats by the intracisternal injection of live Streptococcus pneumoniae. Ro 32-3555 and Ro 32-7315 were injected intraperitoneally, starting at 3 h postinfection. Antibiotic (ceftriaxone) therapy was initiated at 18 h postinfection, and clinical parameters (weight, clinical score, mortality rate) were recorded. Myeloperoxidase activities, concentrations of cytokines and chemokines, concentrations of MMP-2 and MMP-9, and collagen concentrations were measured in the cerebrospinal fluid. Animals were sacrificed at 42 h postinfection, and their brains were assessed by histomorphometry for hippocampal apoptosis and cortical necrosis. Both compounds, while exhibiting disparate MMP and TACE inhibitory profiles, decreased hippocampal apoptosis and cortical injury. Ro 32-3555 reduced mortality rates and cerebrospinal fluid TNF, interleukin-1β (IL-1β) and collagen levels, while Ro 32-7315 reduced weight loss and cerebrospinal fluid TNF and IL-6 levels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The incidence of HIV encephalopathies was determined in an ongoing consecutive autopsy study. Among 345 patients who died from AIDS in Switzerland during 1981-1990, 68 (19%) showed morphological evidence of HIV encephalopathy. Two major histopathological manifestations were observed. Progressive diffuse leukoencephalopathy (PDL) was present in 33 cases and is characterized by a diffuse loss of myelin staining in the deep white matter of the cerebral and cerebellar hemispheres, with scattered multinucleated giant cells but little or no inflammatory reaction. Multinucleated giant cell encephalitis (MGCE) was diagnosed in 32 cases; it's hallmarks are accumulations of multinucleated giant cells with prominent inflammatory reaction and focal necroses. In 3 patients both types of lesions overlapped. Brain tissue from 27 patients was analyzed for the presence of HIV gag sequences using the polymerase chain reaction (PCR) with primers encoding a 109 base pair segment of the viral gene. Amplification succeeded in all patients with clinical and histopathological evidence for HIV encephalopathy but was absent in AIDS patients with opportunistic bacterial, parasitic and/or viral infections. Potential mechanisms by which HIV exerts it's adverse effects on the human CNS are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction The aim of this study was to determine which single measurement on post-mortem cardiac MR reflects actual heart weight as measured at autopsy, assess the intra- and inter-observer reliability of MR measurements, derive a formula to predict heart weight from MR measurements and test the accuracy of the formula to prospectively predict heart weight. Materials and methods 53 human cadavers underwent post-mortem cardiac MR and forensic autopsy. In Phase 1, left ventricular area and wall thickness were measured on short axis and four chamber view images of 29 cases. All measurements were correlated to heart weight at autopsy using linear regression analysis. In Phase 2, single left ventricular area measurements on four chamber view images (LVA_4C) from 24 cases were used to predict heart weight at autopsy based on equations derived during Phase 1. Intra-class correlation coefficient (ICC) was used to determine inter- and intra-reader agreement. Results Heart weight strongly correlates with LVA_4C (r=0.78 M; p<0.001). Intra-reader and inter-reader reliability was excellent for LVA_4C (ICC=0.81–0.91; p<0.001 and ICC=0.90; p<0.001 respectively). A simplified formula for heart weight ([g]≈LVA_4C [mm2]×0.11) was derived based on linear regression analysis. Conclusions This study shows that single circumferential area measurements of the left ventricle in the four chamber view on post-mortem cardiac MR reflect actual heart weight as measured at autopsy. These measurements yield an excellent intra- and inter-reader reliability and can be used to predict heart weight prior to autopsy or to give a reasonable estimate of heart weight in cases where autopsy is not performed.