878 resultados para Automatic device
Resumo:
Abstract OBJECTIVE To compare men and women who have hypertension with reference to the following: high blood pressure, biosocial variables, habits and life styles, mental disorders, and social support networks. METHOD 290 hypertensive patients (women, 62.1%) were evaluated. The assessments involved the following: measuring blood pressure with an automatic measuring device, evaluating social status through the Social Support Scale, and the use of a Self-Report Questionnaire (SRQ-20) to identify common mental disorders. A value of p<0.05 was considered statistically significant. RESULTS Women were found to be different to men (p<0.05) in the following areas having: better control of their blood pressure (64.4% vs 52.7%), less salary incomes, less diabetes, higher total cholesterol, higher body mass index and wider abdominal circumferences. They also had lower systolic blood pressure, lower levels of alcohol consumption and a greater prevalence for mental disorders. The social support assessment revealed that hypertensive women received less help with preparing meals but had more company from people which allowed them to engage in enjoyable activities. CONCLUSION Women had more control over their blood pressure than men, despite the presence of negative biopsychosocial factors that may have influenced their adherence to the treatments.
Resumo:
A model of directed search with a finite number of buyers and sellers is considered, where sellers compete in direct mechanisms. Buyer heterogeneity and Nash equilibrium results in perfect sorting. The restriction to complementary inputs, that the match value function Q is supermodular, in addition coordinates the sellers strategies. In that case, equilibrium implements positive assortative matching, which is efficient and consistent with the stable (cooperative equilibrium) outcome. This provides a non-cooperative and decentralizedsolution for the Assignment Game. Conversely, if buyers are identical, no such coordination is possible, and there is a continuum of equilibria, one of which exhibits price posting, another yields competition in auctions.
Resumo:
The potential of type-2 fuzzy sets for managing high levels of uncertainty in the subjective knowledge of experts or of numerical information has focused on control and pattern classification systems in recent years. One of the main challenges in designing a type-2 fuzzy logic system is how to estimate the parameters of type-2 fuzzy membership function (T2MF) and the Footprint of Uncertainty (FOU) from imperfect and noisy datasets. This paper presents an automatic approach for learning and tuning Gaussian interval type-2 membership functions (IT2MFs) with application to multi-dimensional pattern classification problems. T2MFs and their FOUs are tuned according to the uncertainties in the training dataset by a combination of genetic algorithm (GA) and crossvalidation techniques. In our GA-based approach, the structure of the chromosome has fewer genes than other GA methods and chromosome initialization is more precise. The proposed approach addresses the application of the interval type-2 fuzzy logic system (IT2FLS) for the problem of nodule classification in a lung Computer Aided Detection (CAD) system. The designed IT2FLS is compared with its type-1 fuzzy logic system (T1FLS) counterpart. The results demonstrate that the IT2FLS outperforms the T1FLS by more than 30% in terms of classification accuracy.
Resumo:
This paper studies a balance whose unobservable fulcrum is not necessarilylocated at the middle of its two pans. It presents three differentmodels, showing how this lack of symmetry modifies the observation, theformalism and the interpretation of such a biased measuring device. Itargues that the biased balance can be an interesting source of inspirationfor broadening the representational theory of measurement.
Resumo:
To be diagnostically useful, structural MRI must reliably distinguish Alzheimer's disease (AD) from normal aging in individual scans. Recent advances in statistical learning theory have led to the application of support vector machines to MRI for detection of a variety of disease states. The aims of this study were to assess how successfully support vector machines assigned individual diagnoses and to determine whether data-sets combined from multiple scanners and different centres could be used to obtain effective classification of scans. We used linear support vector machines to classify the grey matter segment of T1-weighted MR scans from pathologically proven AD patients and cognitively normal elderly individuals obtained from two centres with different scanning equipment. Because the clinical diagnosis of mild AD is difficult we also tested the ability of support vector machines to differentiate control scans from patients without post-mortem confirmation. Finally we sought to use these methods to differentiate scans between patients suffering from AD from those with frontotemporal lobar degeneration. Up to 96% of pathologically verified AD patients were correctly classified using whole brain images. Data from different centres were successfully combined achieving comparable results from the separate analyses. Importantly, data from one centre could be used to train a support vector machine to accurately differentiate AD and normal ageing scans obtained from another centre with different subjects and different scanner equipment. Patients with mild, clinically probable AD and age/sex matched controls were correctly separated in 89% of cases which is compatible with published diagnosis rates in the best clinical centres. This method correctly assigned 89% of patients with post-mortem confirmed diagnosis of either AD or frontotemporal lobar degeneration to their respective group. Our study leads to three conclusions: Firstly, support vector machines successfully separate patients with AD from healthy aging subjects. Secondly, they perform well in the differential diagnosis of two different forms of dementia. Thirdly, the method is robust and can be generalized across different centres. This suggests an important role for computer based diagnostic image analysis for clinical practice.
Resumo:
Executive Summary The use of full-body restraint devices is a widespread practice in Iowa’s county jails. Full-body restraints come in the form of restraint chairs, boards, and beds, including two such devices manufactured in Iowa. Iowa law, which refers to these as four- and fivepoint restraints, states they are only to be used when an inmate is a threat to self, others, or jail security. However, the Ombudsman found they were also used on inmates who caused minor disruptions or in response to an inmate’s verbal abuse. In some cases, the restraints were used on inmates with known mental illness who were acting out, though no attempts were made to seek medical or mental health reviews for those inmates while restrained, leading to extended use of the restraint device.
Resumo:
L’objectiu d’aquest projecte és el de dissenyar un comprovador semiautomàtic per a un model d’automatisme que controla l’obertura i el tancament d’una porta. Aquest automatisme requereix d’una verificació de qualitat abans de ser introduït al mercat. La seva comprovació manual és lenta. L’objectiu principal del comprovador, és el de reduir aquest temps de test en almenys un 50% i fer més fàcil la detecció dels errors. El comprovador consta d’un suport per a l’automatisme que transmet els seus punts crítics a una placa de control. Conté un microcontrolador PIC16F887 que gestiona totes les entrades i sortides provinents de l’automatisme. També controla una pantalla LCD de 16x2 caràcters, que mostra els passos a seguir del test i si hi ha algun error. Es fa el disseny d’aquesta placa des de el hardware fins al software. Els resultats del projecte són satisfactoris, ja que compleix els objectius marcats i és un sistema que s’utilitza en l’empresa on es fabriquen aquests automatismes de control de portes.
Resumo:
OBJECTIVE: Atrial fibrillation is a very common heart arrhythmia, associated with a five-fold increase in the risk of embolic strokes. Treatment strategies encompass palliative drugs or surgical procedures all of which can restore sinus rhythm. Unfortunately, atria often fail to recover their mechanical function and patients therefore require lifelong anticoagulation therapy. A motorless volume displacing device (Atripump) based on artificial muscle technology, positioned on the external surface of atrium could avoid the need of oral anticoagulation and its haemorrhagic complications. An animal study was conducted in order to assess the haemodynamic effects that such a pump could provide. METHODS: Atripump is a dome-shape siliconecoated nitinol actuator sewn on the external surface of the atrium. It is driven by a pacemaker-like control unit. Five non-anticoagulated sheep were selected for this experiment. The right atrium was surgically exposed, the device sutured and connected. Haemodynamic parameters and intracardiac ultrasound (ICUS) data were recorded in each animal and under three conditions; baseline; atrial fibrillation (AF); atripump assisted AF (aaAF). RESULTS: In two animals, after 20 min of AF, small thrombi appeared in the right atrial appendix and were washed out once the pump was turned on. Assistance also enhanced atrial ejection fraction. 31% baseline; 5% during AF; 20% under aaAF. Right atrial systolic surfaces (cm2) were; 5.2 +/- 0.3 baseline; 6.2 +/- 0.1 AF; 5.4 +/- 0.3 aaAF. CONCLUSION: This compact and reliable pump seems to restore the atrial "kick" and prevents embolic events. It could avoid long-term anticoagulation therapy and open new hopes in the care of end-stage heart failure.
Resumo:
BACKGROUND: The aim of our study was to assess the feasibility of minimally invasive digestive anastomosis using a modular flexible magnetic anastomotic device made up of a set of two flexible chains of magnetic elements. The assembly possesses a non-deployed linear configuration which allows it to be introduced through a dedicated small-sized applicator into the bowel where it takes the deployed form. A centering suture allows the mating between the two parts to be controlled in order to include the viscerotomy between the two magnetic rings and the connected viscera. METHODS AND PROCEDURES: Eight pigs were involved in a 2-week survival experimental study. In five colorectal anastomoses, the proximal device was inserted by a percutaneous endoscopic technique, and the colon was divided below the magnet. The distal magnet was delivered transanally to connect with the proximal magnet. In three jejunojejunostomies, the first magnetic chain was injected in its linear configuration through a small enterotomy. Once delivered, the device self-assembled into a ring shape. A second magnet was injected more distally through the same port. The centering sutures were tied together extracorporeally and, using a knot pusher, magnets were connected. Ex vivo strain testing to determine the compression force delivered by the magnetic device, burst pressure of the anastomosis, and histology were performed. RESULTS: Mean operative time including endoscopy was 69.2 ± 21.9 min, and average time to full patency was 5 days for colorectal anastomosis. Operative times for jejunojejunostomies were 125, 80, and 35 min, respectively. The postoperative period was uneventful. Burst pressure of all anastomoses was ≥ 110 mmHg. Mean strain force to detach the devices was 6.1 ± 0.98 and 12.88 ± 1.34 N in colorectal and jejunojejunal connections, respectively. Pathology showed a mild-to-moderate inflammation score. CONCLUSIONS: The modular magnetic system showed enormous potential to create minimally invasive digestive anastomoses, and may represent an alternative to stapled anastomoses, being easy to deliver, effective, and low cost.
Resumo:
OBJECTIVE: The estimation of blood pressure is dependent on the accuracy of the measurement devices. We compared blood pressure readings obtained with an automated oscillometric arm-cuff device and with an automated oscillometric wrist-cuff device and then assessed the prevalence of defined blood pressure categories. METHODS: Within a population-based survey in Dar es Salaam (Tanzania), we selected all participants with a blood pressure >/= 160/95 mmHg (n=653) and a random sample of participants with blood pressure <160/95 mmHg (n=662), based on the first blood pressure reading. Blood pressure was reassessed 2 years later for 464 and 410 of the participants, respectively. In these 874 subjects, we compared the prevalence of blood pressure categories as estimated with each device. RESULTS: Overall, the wrist device gave higher blood pressure readings than the arm device (difference in systolic/diastolic blood pressure: 6.3 +/- 17.3/3.7 +/- 11.8 mmHg, P<0.001). However, the arm device tended to give lower readings than the wrist device for high blood pressure values. The prevalence of blood pressure categories differed substantially depending on which device was used, 29% and 14% for blood pressure <120/80 mmHg (arm device versus wrist device, respectively), 30% and 33% for blood pressure 120-139/80-89 mmHg, 17% and 26% for blood pressure 140-159/90-99 mmHg, 12% and 13% for blood pressure 160-179/100-109 mmHg and 13% and 14% for blood pressure >/= 180/110 mmHg. CONCLUSIONS: A large discrepancy in the estimated prevalence of blood pressure categories was observed using two different automatic measurement devices. This emphasizes that prevalence estimates based on automatic devices should be considered with caution.