923 resultados para Adrenal Venous Sampling
Resumo:
Chronic hepatitis C is a major healthcare problem. The response to antiviral therapy for patients with chronic hepatitis C has previously been defined biochemically and by PCR. However, changes in the hepatic venous pressure gradient (HVPG) may be considered as an adjunctive end point for the therapeutic evaluation of antiviral therapy in chronic hepatitis C. It is a validated technique which is safe, well tolerated, well established, and reproducible. Serial HVPG measurements may be the best way to evaluate response to therapy in chronic hepatitis C.
Resumo:
A modified magnesium hydrogen breath test, using end expiratory breath sampling, is described to investigate achlorhydria. The efficacy of this test in the diagnostic investigation of pernicious anaemia was compared with that of serum pepsinogen I. Twenty one patients with pernicious anaemia--that is, patients with achlorhydria--and 22 with healed duodenal ulcer and normal chlorhydria were studied. Magnesium hydrogen breath test, serum pepsinogen I, serum gastrin, and standard gastric acid secretory tests were performed in all subjects. The mean (SEM) hydrogen peak value was lower in patients with pernicious anaemia than in the duodenal ulcer group (21.7 (1.9) v 71.3 (5.2) ppm; p = 0.00005). The hydrogen peak value had a 95.2% sensitivity and a 100% specificity to detect pentagastrin resistant achlorhydria. Mean serum pepsinogen I concentrations were also significantly lower in patients with pernicious anaemia than in the duodenal ulcer group (10.7 (2.7) v 123.6 (11.8) micrograms/l p = 0.00005). Sensitivity and specificity to detect pernicious anaemia were both 100% for pepsinogen I. It is concluded that this modified magnesium hydrogen breath test is a simple, noninvasive, cost effective, and accurate method to assess achlorhydria and may be useful in the diagnostic investigation of patients with suspected pernicious anaemia.
Resumo:
There is anecdotal evidence that athletes use the banned substance Synacthen because of its perceived benefit with its associated rise in cortisol. To test the performance-enhancing effects of Synacthen, eight trained cyclists completed two, 2-day exercise sessions separated by 7-10 days. On the first day of each 2-day exercise session, subjects received either Synacthen (0.25 mg, TX) or placebo (PLA) injection. Performance was assessed by a 20-km time trial (TT) after a 90-min fatigue period on day 1 and without the fatiguing protocol on day 2. Plasma androgens and ACTH concentrations were measured during the exercise bouts as well as the rate of perceived exertion (RPE). Spot urines were analyzed for androgens and glucocorticoids quantification. Basal plasma hormones did not differ significantly between PLA and TX groups before and 24 h after the IM injection (P > 0.05). After TX injection, ACTH peaked at 30 min and hormone profiles were significantly different compared to the PLA trial (P < 0.001). RPE increased significantly in both groups as the exercise sessions progressed (P < 0.001) but was not influenced by treatment. The time to completion of the TT was not affected on both days by Synacthen treatment. In the present study, a single IM injection of synthetic ACTH did not improve either acute or subsequent cycling performance and did not influence perceived exertion. The investigated urinary hormones did not vary after treatment, reinforcing the difficulty for ACTH abuse detection.
Resumo:
PURPOSE: A misleading blood tacrolimus concentration (BTC) value caused by the contamination of a central venous catheter previously used for tacrolimus administration is described. SUMMARY: A 59-year-old woman with severe chronic obstructive pulmonary disease successfully underwent double lung transplantation. In the intensive care unit, she received a continuous i.v. infusion of tacrolimus from days 1 to 5 after transplantation through the distal lumen of a polyurethane triple-lumen central venous catheter. The catheter lumen was flushed twice a day with 0.9% sodium chloride injection. The proximal lumen was used for blood sampling after being flushed; the first 10 mL of blood was discarded. BTCs determined in whole blood one, four, and five days after transplantation were within the therapeutic range of 5-15 ng/mL. On day five the patient was transferred to the thoracic surgery ward and was switched to oral tacrolimus 1.5 mg twice daily. The BTC on day 6 was unexpectedly high at 134.5 ng/mL. The patient's clinical status was normal, and no signs of tacrolimus toxicity were observed. On day 7, blood samples were drawn from a peripheral vein and simultaneously through the central venous catheter. Although the central venous catheter had not been exposed to tacrolimus during the preceding two days, it yielded blood with a BTC eight times higher than the BTC in blood from the peripheral vein (41.4 ng/mL versus 5.1 ng/mL). CONCLUSION: The collection of blood from a central venous catheter lumen that had been used for tacrolimus administration resulted in a BTC about eight times higher than what was measured in peripheral blood.
Resumo:
BACKGROUND: In an experimental setting, the performance of the LifeBox, a new portable extracorporeal membrane oxygenator (ECMO) system suitable for patient transport, is presented. Standard rectilinear percutaneous cannulae are normally employed for this purpose, but have limited flow and pressure delivery due to their rigid structure. Therefore, we aimed to determine the potential for flow increase by using self-expanding venous cannulae. METHODS: Veno-arterial bypass was established in three pigs (40.6+/-5.1 kg). The venous line of the cardiopulmonary bypass was established by cannulation of the external jugular vein. The arterial side of the circulation was secured by cannulation of the common carotid artery. Two different venous cannulae (SmartCanula 18/36F 430mm and Biomedicus 19F) were examined for their functional integrity when used in conjunction with the centrifugal pump (500-3000 RPM) of the LifeBox system. RESULTS: At 1500, 2000, 2500, and 3000 RPM, the blood flow increased steadily for each cannula, but remained higher in the self-expanding cannula. That is, the 19F rectilinear cannula achieved a blood flow of 0.93+/-0.14, 1.47+/-0.37, 1.9+/-0.68, and 1.5+/-0.9 l/min, respectively, and the 18/36F self-expanding cannula achieved 1.1+/-0.1, 1.9+/-0.33, 2.8+/-0.39 and 3.66+/-0.52 l/min. However, when tested for venous line pressure, the standard venous cannula achieved -29+/-10.7mmHg while the self-expanding cannula achieved -13.6 +/-4.3mmHg at 1500 RMP. As the RPM increased from 2500 to 3000, the venous line pressure accounted for -141.9+/-20 and -98+/-7.3mmHg for the 19F rectilinear cannula and -30.6+/-6.4 and -45+/-11.6mmHg for the self-expanding cannula. CONCLUSION: The self-expanding cannula exhibited superior venous drainage ability when compared to the performance of the standard rectilinear cannula with the use of the LifeBox. The flow rate achieved was approximately 40% greater than the standard drainage device, with a maximal pump flow recorded at 4.3l/min.
Resumo:
BACKGROUND: In patients with acute venous thromboembolism and renal insufficiency, initial therapy with unfractionated heparin may have some advantages over low-molecular-weight heparin. METHODS: We used the Registro Informatizado de la Enfermedad TromboEmbólica (RIETE) Registry data to evaluate the 15-day outcome in 38,531 recruited patients. We used propensity score matching to compare patients treated with unfractionated heparin with those treated with low-molecular-weight heparin in 3 groups stratified by creatinine clearance levels at baseline: >60 mL/min, 30 to 60 mL/min, or <30 mL/min. RESULTS: Patients initially receiving unfractionated heparin therapy (n = 2167) more likely had underlying diseases than those receiving low-molecular-weight heparin (n = 34,665). Propensity score-matched groups of patients with creatinine clearance levels >60 mL/min (n = 1598 matched pairs), 30 to 60 mL/min (n = 277 matched pairs), and <30 mL/min (n = 210 matched pairs) showed an increased 15-day mortality for unfractionated heparin compared with low-molecular-weight heparin (4.5% vs 2.4% [P = .001], 5.4% vs 5.8% [P = not significant], and 15% vs 8.1% [P = .02], respectively), an increased rate of fatal pulmonary embolism (2.8% vs 1.2% [P = .001], 3.2% vs 2.5% [P = not significant], and 5.7% vs 2.4% [P = .02], respectively), and a similar rate of fatal bleeding (0.3% vs 0.3%, 0.7% vs 0.7%, and 0.5% vs 0.0%, respectively). Multivariate analysis confirmed that patients treated with unfractionated heparin were at increased risk for all-cause death (odds ratio, 1.8; 95% confidence interval, 1.3-2.4) and fatal pulmonary embolism (odds ratio, 2.3; 95% confidence interval, 1.5-3.6). CONCLUSIONS: In comparison with low-molecular-weight heparin, initial therapy with unfractionated heparin was associated with a higher mortality and higher rate of fatal pulmonary embolism in patients with creatinine clearance levels >60 mL/min or <30 mL/min, but not in those with levels between 30 and 60 mL/min.
Resumo:
BACKGROUND: Multislice CT (MSCT) combined with D-dimer measurement can safely exclude pulmonary embolism in patients with a low or intermediate clinical probability of this disease. We compared this combination with a strategy in which both a negative venous ultrasonography of the leg and MSCT were needed to exclude pulmonary embolism. METHODS: We included 1819 consecutive outpatients with clinically suspected pulmonary embolism in a multicentre non-inferiority randomised controlled trial comparing two strategies: clinical probability assessment and either D-dimer measurement and MSCT (DD-CT strategy [n=903]) or D-dimer measurement, venous compression ultrasonography of the leg, and MSCT (DD-US-CT strategy [n=916]). Randomisation was by computer-generated blocks with stratification according to centre. Patients with a high clinical probability according to the revised Geneva score and a negative work-up for pulmonary embolism were further investigated in both groups. The primary outcome was the 3-month thromboembolic risk in patients who were left untreated on the basis of the exclusion of pulmonary embolism by diagnostic strategy. Clinicians assessing outcome were blinded to group assignment. Analysis was per protocol. This study is registered with ClinicalTrials.gov, number NCT00117169. FINDINGS: The prevalence of pulmonary embolism was 20.6% in both groups (189 cases in DD-US-CT group and 186 in DD-CT group). We analysed 855 patients in the DD-US-CT group and 838 in the DD-CT group per protocol. The 3-month thromboembolic risk was 0.3% (95% CI 0.1-1.1) in the DD-US-CT group and 0.3% (0.1-1.2) in the DD-CT group (difference 0.0% [-0.9 to 0.8]). In the DD-US-CT group, ultrasonography showed a deep-venous thrombosis in 53 (9% [7-12]) of 574 patients, and thus MSCT was not undertaken. INTERPRETATION: The strategy combining D-dimer and MSCT is as safe as the strategy using D-dimer followed by venous compression ultrasonography of the leg and MSCT for exclusion of pulmonary embolism. An ultrasound could be of use in patients with a contraindication to CT.
Resumo:
The authors compared radial steady-state free precession (SSFP) coronary magnetic resonance (MR) angiography, cartesian k-space sampling SSFP coronary MR angiography, and gradient-echo coronary MR angiography in 16 healthy adults and four pilot study patients. Standard gradient-echo MR imaging with a T2 preparatory pulse and cartesian k-space sampling was the reference technique. Image quality was compared by using subjective motion artifact level and objective contrast-to-noise ratio and vessel sharpness. Radial SSFP, compared with cartesian SSFP and gradient-echo MR angiography, resulted in reduced motion artifacts and superior vessel sharpness. Cartesian SSFP resulted in increased motion artifacts (P <.05). Contrast-to-noise ratio with radial SSFP was lower than that with cartesian SSFP and similar to that with the reference technique. Radial SSFP coronary MR angiography appears preferable because of improved definition of vessel borders.
Resumo:
Captan and folpet are two fungicides largely used in agriculture, but biomonitoring data are mostly limited to measurements of captan metabolite concentrations in spot urine samples of workers, which complicate interpretation of results in terms of internal dose estimation, daily variations according to tasks performed, and most plausible routes of exposure. This study aimed at performing repeated biological measurements of exposure to captan and folpet in field workers (i) to better assess internal dose along with main routes-of-entry according to tasks and (ii) to establish most appropriate sampling and analysis strategies. The detailed urinary excretion time courses of specific and non-specific biomarkers of exposure to captan and folpet were established in tree farmers (n = 2) and grape growers (n = 3) over a typical workweek (seven consecutive days), including spraying and harvest activities. The impact of the expression of urinary measurements [excretion rate values adjusted or not for creatinine or cumulative amounts over given time periods (8, 12, and 24 h)] was evaluated. Absorbed doses and main routes-of-entry were then estimated from the 24-h cumulative urinary amounts through the use of a kinetic model. The time courses showed that exposure levels were higher during spraying than harvest activities. Model simulations also suggest a limited absorption in the studied workers and an exposure mostly through the dermal route. It further pointed out the advantage of expressing biomarker values in terms of body weight-adjusted amounts in repeated 24-h urine collections as compared to concentrations or excretion rates in spot samples, without the necessity for creatinine corrections.
Resumo:
Hematocrit (Hct) is one of the most critical issues associated with the bioanalytical methods used for dried blood spot (DBS) sample analysis. Because Hct determines the viscosity of blood, it may affect the spreading of blood onto the filter paper. Hence, accurate quantitative data can only be obtained if the size of the paper filter extracted contains a fixed blood volume. We describe for the first time a microfluidic-based sampling procedure to enable accurate blood volume collection on commercially available DBS cards. The system allows the collection of a controlled volume of blood (e.g., 5 or 10 μL) within several seconds. Reproducibility of the sampling volume was examined in vivo on capillary blood by quantifying caffeine and paraxanthine on 5 different extracted DBS spots at two different time points and in vitro with a test compound, Mavoglurant, on 10 different spots at two Hct levels. Entire spots were extracted. In addition, the accuracy and precision (n = 3) data for the Mavoglurant quantitation in blood with Hct levels between 26% and 62% were evaluated. The interspot precision data were below 9.0%, which was equivalent to that of a manually spotted volume with a pipet. No Hct effect was observed in the quantitative results obtained for Hct levels from 26% to 62%. These data indicate that our microfluidic-based sampling procedure is accurate and precise and that the analysis of Mavoglurant is not affected by the Hct values. This provides a simple procedure for DBS sampling with a fixed volume of capillary blood, which could eliminate the recurrent Hct issue linked to DBS sample analysis.
Resumo:
Meropenem, a carbapenem antibiotic displaying a broad spectrum of antibacterial activity, is administered in Medical Intensive Care Unit to critically ill patients undergoing continuous veno-venous haemodiafiltration (CVVHDF). However, there are limited data available to substantial rational dosing decisions in this condition. In an attempt to refine our knowledge and propose a rationally designed dosage regimen, we have developed a HPLC method to determine meropenem after solid-phase extraction (SPE) of plasma and dialysate fluids obtained from patients under CVVHDF. The assay comprises the simultaneous measurement of meropenem's open-ring metabolite UK-1a, whose fate has never been studied in CVVHDF patients. The clean-up procedure involved a SPE on C18 cartridge. Matrix components were eliminated with phosphate buffer pH 7.4 followed by 15:85 MeOH-phosphate buffer pH 7.4. Meropenem and UK-1a were subsequently desorbed with MeOH. The eluates were evaporated under nitrogen at room temperature (RT) and reconstituted in phosphate buffer pH 7.4. Separation was performed at RT on a Nucleosil 100-5 microm C18 AB cartridge column (125 x 4 mm I.D.) equipped with a guard column (8 x 4 mm I.D.) with UV-DAD detection set at 208 nm. The mobile phase was 1 ml min(-1), using a step-wise gradient elution program: %MeOH/0.005 M tetrabutylammonium chloride pH 7.4; 10/90-50/50 in 27 min. Over the range of 5-100 microg ml(-1), the regression coefficient of the calibration curves (plasma and dialysate) were >0.998. The absolute extraction recoveries of meropenem and UK-1a in plasma and filtrate-dialysate were stable and ranged from 88-93 to 72-77% for meropenem, and from 95-104 to 75-82% for UK-1a. In plasma and filtrate-dialysate, respectively, the mean intra-assay precision was 4.1 and 2.6% for meropenem and 4.2 and 3.7% for UK-1a. The inter-assay variability was 2.8 and 3.6% for meropenem and 2.3 and 2.8% for UK-1a. The accuracy was satisfactory for both meropenem and UK-1a with deviation never exceeding 9.0% of the nominal concentrations. The stability of meropenem, studied in biological samples left at RT and at +4 degrees C, was satisfactory with < 5% degradation after 1.5 h in blood but reached 22% in filtrate-dialysate samples stored at RT for 8 h, precluding accurate measurements of meropenem excreted unchanged in the filtrate-dialysate left at RT during the CVVHDF procedure. The method reported here enables accurate measurements of meropenem in critically ill patients under CVVHDF, making dosage individualisation possible in such patients. The levels of the metabolite UK-1a encountered in this population of patients were higher than those observed in healthy volunteers but was similar to those observed in patients with renal impairment under hemodialysis.
Resumo:
OBJECTIVE: Accuracy studies of Patient Safety Indicators (PSIs) are critical but limited by the large samples required due to low occurrence of most events. We tested a sampling design based on test results (verification-biased sampling [VBS]) that minimizes the number of subjects to be verified. METHODS: We considered 3 real PSIs, whose rates were calculated using 3 years of discharge data from a university hospital and a hypothetical screen of very rare events. Sample size estimates, based on the expected sensitivity and precision, were compared across 4 study designs: random and VBS, with and without constraints on the size of the population to be screened. RESULTS: Over sensitivities ranging from 0.3 to 0.7 and PSI prevalence levels ranging from 0.02 to 0.2, the optimal VBS strategy makes it possible to reduce sample size by up to 60% in comparison with simple random sampling. For PSI prevalence levels below 1%, the minimal sample size required was still over 5000. CONCLUSIONS: Verification-biased sampling permits substantial savings in the required sample size for PSI validation studies. However, sample sizes still need to be very large for many of the rarer PSIs.