997 resultados para Actuation voltage


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the paper, the total damping and synchronising torques, which determine the dynamic stability of a synchronous generator in a power system, have been traced to their origin. The positive and negative components released or consumed by the voltage regulator, and by the various windings of the machine, have been isolated, with the object of making a quantitative assessment of the effects of various gains and time constants on the dynamic stability of a synchronous machine under different operating conditions. The analysis is based on the properties of quadratic invariance in tensor calculus. An alternative solution by network analysis has also been provided to establish the validity of the tensor approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bypass operation with the aid of a special bypass valve is an important part of present-day schemes of protection for h.v. d.c. transmission systems. In this paper, the possibility of using two valves connected to any phase in the bridge convertor for the purpose of bypass operation is studied. The scheme is based on the use of logic circuits in conjunction with modified methods of fault detection. Analysis of the faults in a d.c. transmission system is carried out with the object of determining the requirements of such a logic-circuit control system. An outline of the scheme for the logic-circuit control of the bypass operation for both rectifier and invertor bridges is then given. Finally, conclusions are drawn regarding the advantages of such a system, which include reduction in the number of valves, prevention of severe faults and fast clearance of faults, in addition to the immediate location of the fault and its nature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A mathematical model has been proposed to determine the voltage/current characteristic of the surge diverter for a wide range of currents of short duration of 8/20 and 4/10ÿs waveshapes. Experimental data agree well with the proposed model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the determination of the response time of u.h.v. damped capacitive impulse voltage dividers using the CIGRE IMR-1MS group (1) method and the arrangement suggested by the International Electrotechnical Commission (the I EC square loop),the surge impedance of the connecting lead has been found to influence the accuracy of determination. To avoid this difficulty,a new graphical procedure is proposed. As this method uses only those data points which can be determined with good accuracy, errors in response-time area evaluation do not influence the result.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A torque control scheme, based on a direct torque control (DTC) algorithm using a 12-sided polygonal voltage space vector, is proposed for a variable speed control of an open-end induction motor drive. The conventional DTC scheme uses a stator flux vector for the sector identification and then the switching vector to control stator flux and torque. However, the proposed DTC scheme selects switching vectors based on the sector information of the estimated fundamental stator voltage vector and its relative position with respect to the stator flux vector. The fundamental stator voltage estimation is based on the steady-state model of IM and the synchronous frequency of operation is derived from the computed stator flux using a low-pass filter technique. The proposed DTC scheme utilizes the exact positions of the fundamental stator voltage vector and stator flux vector to select the optimal switching vector for fast control of torque with small variation of stator flux within the hysteresis band. The present DTC scheme allows full load torque control with fast transient response to very low speeds of operation, with reduced switching frequency variation. Extensive experimental results are presented to show the fast torque control for speed of operation from zero to rated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power semiconductor devices have finite turn on and turn off delays that may not be perfectly matched. In a leg of a voltage source converter, the simultaneous turn on of one device and the turn off of the complementary device will cause a DC bus shoot through, if the turn off delay is larger than the turn on delay time. To avoid this situation it is common practice to blank the two complementary devices in a leg for a small duration of time while switching, which is called dead time. This paper proposes a logic circuit for digital implementation required to control the complementary devices of a leg independently and at the same time preventing cross conduction of devices in a leg, and while providing accurate and stable dead time. This implementation is based on the concept of finite state machines. This circuit can also block improper PWM pulses to semiconductor switches and filters small pulses notches below a threshold time width as the narrow pulses do not provide any significant contribution to average pole voltage, but leads to increased switching loss. This proposed dead time logic has been implemented in a CPLD and is implemented in a protection and delay card for 3- power converters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High voltage power supplies for radar applications are investigated, which are subjected to pulsed load (125 kHz and 10% duty cycle) with stringent specifications (<0.01% regulation, efficiency>85%, droop<0.5 V/micro-sec.). As good regulation and stable operation requires the converter to be switched at much higher frequency than the pulse load frequency, transformer poses serious problems of insulation failure and higher losses. Few converter topologies are proposed to tackle these problems. A study is made regarding the beat frequency oscillations that may exist with pulsed loading. It is illustrated with respect to the proposed converter topologies. Methods are proposed to eliminate or minimize these oscillations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metal oxide varistors (MOV) are popularly used to protect offline electronic equipment against power line transients. The offline switched mode power supplies (SMPS) use power line filters and MOVs in the front-end. The power line filter is used to reduce the conducted noise emission into the power line and the MOVs connected before this line filter and the MOVs connected before this line filter to clamp line transients to safer levels thereby protecting the SMPS. Because of the presence of 'X' capacitors at the input of line filter the MOV clamping voltage is increased. This paper presents one such case and gives theoretical and experimental results. An approximate method to predetermine the magnitude of such clamping voltages is also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A topology for voltage-space phasor generation equivalent to a five-level inverter for an open-end winding induction motor is presented. The open-end winding induction motor is fed from both ends by two three-level inverters. The three-level inverters are realised by cascading two two-level inverters. This inverter scheme does not experience neutral-point fluctuations. Of the two three-level inverters only one will be switching at any instant in the lower speed ranges. In the multilevel carrier-based SPWM used for the proposed drive, a progressive discrete DC bias depending on the speed range is given to the reference wave to reduce the inverter switchings. The drive is implemented and tested with a 1 HP open-end winding induction motor and experimental results are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a compact electric discharge plasma source for controlling NOX emission in diesel engine exhaust. Boost converter is used to boost to solar powered battery voltage to 24V, further an automobile ignition coil was used to generate the high voltage pulse using fly-back topology. This design is aimed at retrofitting the existing catalytic converters with pulse assisted cleaning technique. In this paper we bring out a relative comparison of discharge plasma and plasma-adsorbent process at different gas flow rates. Activated alumina was used as adsorbent. The main emphasis is laid on the development of a compact pulse source from 12V battery, which is powered by the solar, for the removal of NOX from the filtered diesel engine exhaust.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a compact electric discharge plasma source for controlling NOX emission in diesel engine exhaust. Boost converter is used to boost to solar powered battery voltage to 24V, further an automobile ignition coil was used to generate the high voltage pulse using fly-back topology. This design is aimed at retrofitting the existing catalytic converters with pulse assisted cleaning technique. In this paper we bring out a relative comparison of discharge plasma and plasma-adsorbent process at different gas flow rates. Activated alumina was used as adsorbent. The main emphasis is laid on the development of a compact pulse source from 12V battery, which is powered by the solar, for the removal of NOX from the filtered diesel engine exhaust.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a method for minimizing the sum of the square of voltage deviations by a least-square minimization technique, and thus improving the voltage profile in a given system by adjusting control variables, such as tap position of transformers, reactive power injection of VAR sources and generator excitations. The control variables and dependent variables are related by a matrix J whose elements are computed as the sensitivity matrix. Linear programming is used to calculate voltage increments that minimize transmission losses. The active and reactive power optimization sub-problems are solved separately taking advantage of the loose coupling between the two problems. The proposed algorithm is applied to IEEE 14-and 30-bus systems and numerical results are presented. The method is computationally fast and promises to be suitable for implementation in real-time dispatch centres.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A numerically stable sequential Primal–Dual LP algorithm for the reactive power optimisation (RPO) is presented in this article. The algorithm minimises the voltage stability index C 2 [1] of all the load buses to improve the system static voltage stability. Real time requirements such as numerical stability, identification of the most effective subset of controllers for curtailing the number of controllers and their movement can be handled effectively by the proposed algorithm. The algorithm has a natural characteristic of selecting the most effective subset of controllers (and hence curtailing insignificant controllers) for improving the objective. Comparison with transmission loss minimisation objective indicates that the most effective subset of controllers and their solution identified by the static voltage stability improvement objective is not the same as that of the transmission loss minimisation objective. The proposed algorithm is suitable for real time application for the improvement of the system static voltage stability.