993 resultados para 3D dose distribution


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Primary objective: The study aimed to examine the changes in water distribution in the soft tissue during systemic steroid activity. Research design: A three-way cross-over, randomized, placebo-controlled, double-blind trial was used, including 4 weeks of fluticasone propionate pMDI 200 mug b.i.d. delivered via Babyhaler(R), budesonide pressurized metered dose inhaler (pMDI) 200 mug b.i.d. delivered via Nebuchamber(R) and placebo. Spacers were primed before use. In total, 40 children aged 1-3 years, with mild intermittent asthma were included. Twenty-five of the children completed all three treatments. At the end of each treatment period body impedance and skin ultrasonography were measured. Methods and procedures: We measured changes in water content of the soft tissues by two methods. Skin ultrasonography was used to detect small changes in dermal water content, and bioelectrical impedance was used to assess body water content and distribution. Main outcomes and results: We found an increase in skin density of the shin from fluticasone as measured by ultrasonography (p = 0.01). There was a tendency for a consistent elevation of impedance parameters from active treatments compared to placebo although overall this effect was not statistically significant (0.1< p <0.2). However, sub-analyses indicated a significant effect on whole-body and leg impedance from budesonide treatment (p <0.05). Conclusion: Decreased growth during inhaled steroid treatment seems to partly reflect generalized changes in body water.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To determine the pharmacokinetics of carboplatin in sulphur-crested cockatoos, so that its use in clinical studies in birds can be considered. Design A pharmacokinetic study of carboplatin, following a single intravenous (IV) or intraosseus (10) infusion over 3 min, was performed in six healthy sulphur-crested cockatoos (Cacatua galerita). Procedure Birds were anaesthetised and a jugular vein cannulated for blood collection. Carboplatin (5 mg/kg) was infused over 3 min by the IV route in four birds via the contralateral jugular vein, and by the 10 route in two birds via the ulna. Serial blood samples were collected for 96 h after initiation of the infusion. Tissue samples from 11 organs were obtained at necropsy, 96 h after carboplatin administration. Total Pt and filterable Pt in plasma and tissue Pt concentrations were assayed by inductively coupled plasma-mass spectrometry. A noncompartmental pharmacokinetic analysis was performed on the plasma data. Results The mean +/- SD for the C-max of filterable Pt was 27.3 +/- 4.06 mg/L and in all six birds occurred at the end of the 3 min infusion, thenceforth declining exponentially over the next 6 h to an average concentration of 0.128 +/- 0.065 mg/L. The terminal half-life (T-1/2) was 1.0 +/- 0.17 h, the systemic clearance (CI) was 5.50 +/- 1.06 mL/min/kg and the volume of distribution (Vss) was 0.378 +/- 0.073 L/kg. The extrapolated area under the curve (AUC(0-x)) was 0.903 +/- 0.127 mg/mL.min; the area extrapolated past the last (6 h) data point to infinite time averaged only 1.25% of the total AUC(0-x). The kidneys had the greatest accumulation of Pt (7.04 +/- 3.006 mug/g), followed by the liver (3.08 +/- 1.785 mug/g DM). Conclusions and clinical relevance Carboplatin infusion in sulphur-crested cockatoos produced mild, transient alimentary tract signs and the Pt plasma concentration was similar whether carboplatin was given intravenously or intraosseously. Filterable plasma Pt concentrations for carboplatin persisted longer than for cisplatin, due mostly to the difference in systemic clearance between these drugs in sulphur-crested cockatoos. The distribution of tissue Pt after carboplatin administration was similar to that reported for cisplatin in sulphur-crested cockatoos. Despite anatomical, physiological and biochemical differences among animal species, the pharmacokinetic disposition of filterable Pt in the sulphur-crested cockatoo shares some features with the kinetics reported previously in other animals and human beings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To determine the pharmacokinetics of doxorubicin in sulphur-crested cockatoos, so that its use in clinical studies in birds can be considered. Design A pharmacokinetic study of doxorubicin, following a single intravenous (IV) infusion over 20 min, was performed in four healthy sulphur-crested cockatoos (Cacatua galerita). Procedure Birds were anaesthetised and both jugular veins were cannulated, one for doxorubicin infusion and the other for blood collection. Doxorubicin hydrochloride (2 mg/kg) in normal saline was infused IV over 20 min at a constant rate. Serial blood samples were collected for 96 h after initiation of the infusion. Plasma doxorubicin concentrations were assayed using an HPLC method involving ethyl acetate extraction, reverse-phase chromatography and fluorescence detection. The limit of quantification was 20 ng/mL. Established non-parametric methods were used for the analysis of plasma doxorubicin data. Results During the infusion the mean +/- SD for the C-max of doxorubicin was 4037 +/- 2577 ng/mL. Plasma concentrations declined biexponentially immediately after the infusion was ceased. There was considerable intersubject variability in all pharmacokinetic variables. The terminal (beta-phase) half-life was 41.4 +/- 18.5 min, the systemic clearance (Cl) was 45.7 +/- 18.0 mL/min/kg, the mean residence time (MRT) was 4.8 +/- 1.4 min, and the volume of distribution at steady state (V-SS) was 238 131 mL/kg. The extrapolated area under the curve (AUC(0-infinity)) was 950 +/- 677 ng/mL.h. The reduced metabolite, doxorubicinol, was detected in the plasma of all four parrots but could be quantified in only one bird with the profile suggesting formation rate-limited pharmacokinetics of doxorubicinol. Conclusions and clinical relevance Doxorubicin infusion in sulphur-crested cockatoos produced mild, transient inappetence. The volume of distribution per kilogram and terminal half-life were considerably smaller, but the clearance per kilogram was similar to or larger than reported in the dog, rat and humans. Traces of doxorubicinol, a metabolite of doxorubicin, were detected in the plasma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Langerhans cells (LCs) can be targeted with DNA-coated gold micro-projectiles ("Gene Gun") to induce potent cellular and humoral immune responses. It is likely that the relative volumetric distribution of LCs and keratinocytes within the epidermis impacts on the efficacy of Gene Gun immunization protocols. This study quantified the three-dimensional (3D) distribution of LCs and keratinocytes in the mouse skin model with a near-infrared multiphoton laser-scanning microscope (NIR-MPLSM). Stratum corneum (SC) and viable epidermal thickness measured with MPLSM was found in close agreement with conventional histology. LCs were located in the vertical plane at a mean depth of 14.9 mum, less than 3 mum above the dermo-epidermal boundary and with a normal histogram distribution. This likely corresponds to the fact that LCs reside in the suprabasal layer (stratum germinativum). The nuclear volume of keratinocytes was found to be approximately 1.4 times larger than that of resident LCs (88.6 mum3). Importantly, the ratio of LCs to keratinocytes in mouse ear skin (1:15) is more than three times higher than that reported for human breast skin (1:53). Accordingly, cross-presentation may be more significant in clinical Gene Gun applications than in pre-clinical mouse studies. These interspecies differences should be considered in pre-clinical trials using mouse models.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the creation of 3D statistical shape models of the knee bones and their use to embed information into a segmentation system for MRIs of the knee. We propose utilising the strong spatial relationship between the cartilages and the bones in the knee by embedding this information into the created models. This information can then be used to automate the initialisation of segmentation algorithms for the cartilages. The approach used to automatically generate the 3D statistical shape models of the bones is based on the point distribution model optimisation framework of Davies. Our implementation of this scheme uses a parameterized surface extraction algorithm, which is used as the basis for the optimisation scheme that automatically creates the 3D statistical shape models. The current approach is illustrated by generating 3D statistical shape models of the patella, tibia and femoral bones from a segmented database of the knee. The use of these models to embed spatial relationship information to aid in the automation of segmentation algorithms for the cartilages is then illustrated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents an automated segmentation approach for MR images of the knee bones. The bones are the first stage of a segmentation system for the knee, primarily aimed at the automated segmentation of the cartilages. The segmentation is performed using 3D active shape models (ASM), which are initialized using an affine registration to an atlas. The 3D ASMs of the bones are created automatically using a point distribution model optimization scheme. The accuracy and robustness of the segmentation approach was experimentally validated using an MR database of fat suppressed spoiled gradient recall images.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We measure complex amplitude of scattered wave in the far field, and justify theoretically and numerically solution of the inverse scattering problem. This allows single-shot reconstructing of dielectric function distribution during direct femtosecond laser micro-fabrication.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report on a new technique to reconstruct the 3D dielectric function change in transparent dielectric materials and the application of the technique for on-line monitoring of refractive index modification in BK7 glass during direct femtosecond laser microfabrication. The complex optical field scattered from the modified region is measured using two-beam, single-shot interferogram and the distribution of the modified refractive index is reconstructed by numerically solving the inverse scattering problem in Born approximation. The optical configuration suggested is further development of digital holographic microscopy (DHM). It takes advantage of high spatial resolution and almost the same optical paths for both interfering beams, and allows ultrafast time resolution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Photoreactive liposomes have been exploited as a means of developing 3D tissue constructs. Liposomes formulated using the photosensitive lipid 1,2-bis(4-(n-butyl)phenylazo-4′-phenylbutyroyl)phosphatidylcholine (Bis Azo PC), which undergoes conformational change on stimulation with long wavelength ultraviolet light, were prepared with entrapped CaCl2 before being incorporated into a 4% alginate solution. It was shown that stimulation of the photosensitive lipid using a light emitting diode (LED) (peak emission at 385 nm, dose equivalent to 9 mJ/cm2) caused the release of liposome-entrapped CaCl2, resulting in cross-linking of the alginate solution and immobilisation of bone-derived cells over a range of seeding densities, approximately 97% of which remained viable for periods of up to 14 days in culture. Entrapment volumes of a variety of liposome types were evaluated and interdigitating fusion vesicles were identified as having the highest payload (24%), however the inclusion of cholesterol as a means of shifting Bis Azo PC sensitivity into the visible light wavelengths resulted in an approximately 10-fold reduction in calcium entrapment. This application of light-sensitised liposomes offers the potential to create complex tissue engineering substrates containing cells immobilised in precise locations, in contrast with substrates onto which cells are seeded post-production. © 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We measure complex amplitude of scattered wave in the far field, and justify theoretically and numerically solution of the inverse scattering problem. This allows single-shot reconstructing of dielectric function distribution during direct femtosecond laser micro-fabrication.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report on a new technique to reconstruct the 3D dielectric function change in transparent dielectric materials and the application of the technique for on-line monitoring of refractive index modification in BK7 glass during direct femtosecond laser microfabrication. The complex optical field scattered from the modified region is measured using two-beam, single-shot interferogram and the distribution of the modified refractive index is reconstructed by numerically solving the inverse scattering problem in Born approximation. The optical configuration suggested is further development of digital holographic microscopy. It takes advantage of high spatial resolution and almost the same optical paths for both interfering beams, and allows ultrafast time resolution. © Springer Science+Business Media, LLC. 2011.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background To determine the pharmacokinetics (PK) of a new i.v. formulation of paracetamol (Perfalgan) in children ≤15 yr of age. Methods After obtaining written informed consent, children under 16 yr of age were recruited to this study. Blood samples were obtained at 0, 15, 30 min, 1, 2, 4, 6, and 8 h after administration of a weight-dependent dose of i.v. paracetamol. Paracetamol concentration was measured using a validated high-performance liquid chromatographic assay with ultraviolet detection method, with a lower limit of quantification (LLOQ) of 900 pg on column and an intra-day coefficient of variation of 14.3% at the LLOQ. Population PK analysis was performed by non-linear mixed-effect modelling using NONMEM. Results One hundred and fifty-nine blood samples from 33 children aged 1.8–15 yr, weight 13.7–56 kg, were analysed. Data were best described by a two-compartment model. Only body weight as a covariate significantly improved the goodness of fit of the model. The final population models for paracetamol clearance (CL), V1 (central volume of distribution), Q (inter-compartmental clearance), and V2 (peripheral volume of distribution) were: 16.51×(WT/70)0.75, 28.4×(WT/70), 11.32×(WT/70)0.75, and 13.26×(WT/70), respectively (CL, Q in litres per hour, WT in kilograms, and V1 and V2 in litres). Conclusions In children aged 1.8–15 yr, the PK parameters for i.v. paracetamol were not influenced directly by age but were by total body weight and, using allometric size scaling, significantly affected the clearances (CL, Q) and volumes of distribution (V1, V2).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We measure complex amplitude of scattered wave in the far field, and justify theoretically and numerically solution of the inverse scattering problem. This allows single-shot reconstructing of dielectric function distribution during direct femtosecond laser micro-fabrication.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel biocompatible and biodegradable polymer, termed poly(Glycerol malate co-dodecanedioate) (PGMD), was prepared by thermal condensation method and used for fabrication of nanoparticles (NPs). PGMD NPs were prepared using the single oil emulsion technique and loaded with an imaging/hyperthermia agent (IR820) and a chemotherapeutic agent (doxorubicin, DOX). The size of the void PGMD NPs, IR820-PGMD NPs and DOX-IR820-PGMD NPs were approximately 90 nm, 110 nm, and 125 nm respectively. An acidic environment (pH=5.0) induced higher DOX and IR820 release compared to pH=7.4. DOX release was also enhanced by exposure to laser, which increased the temperature to 42°C. Cytotoxicity of DOX-IR820-PGMD NPs was comparable in MES-SA but was higher in Dx5 cells compared to free DOX plus IR820 (p<0.05). The combination of hyperthermia (HT) and chemotherapy improved cytotoxicity in both cell lines. We also explored the cellular response after rapid, short-term and low thermal dose (laser/Dye/NP) induced-heating, and compared it to slow, long-term and high thermal dose cell incubator heating by investigating the reactive oxygen species (ROS) level, hypoxia-inducible factor-1&agr; (HIF-1&agr;) and vascular endothelial growth factor (VEGF) expression. The cytotoxicity of IR820-PGMD NPs after laser/Dye/NP HT resulted in higher cancer cell killing compared to incubator HT. ROS level, HIF-1&agr; and VEGF expression were elevated under incubator HT, while maintained at the baseline level under the laser/Dye/NP HT. In vivo mouse studies showed that NP formulation significantly improved the plasma half-life of IR820 after tail vein injection. Significant lower IR820 content was observed in kidney in DOX-IR820-PGMD NP treatment as compared to free IR820 treatment in our biodistribution studies (p<0.05). In conclusion, both IR820-PGMD NPs and DOX-IR820-PGMD NPs were successfully developed and used for both imaging and therapeutic purposes. Rapid and short-term laser/Dye/NP HT, with a low thermal dose, did not up-regulate HIF-1&agr; and VEGF expression, whereas slow and long-term incubator HT, with a high thermal dose, can enhance expression of both HIF-1&agr; and VEGF.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

While it is well known that exposure to radiation can result in cataract formation, questions still remain about the presence of a dose threshold in radiation cataractogenesis. Since the exposure history from diagnostic CT exams is well documented in a patient’s medical record, the population of patients chronically exposed to radiation from head CT exams may be an interesting area to explore for further research in this area. However, there are some challenges in estimating lens dose from head CT exams. An accurate lens dosimetry model would have to account for differences in imaging protocols, differences in head size, and the use of any dose reduction methods.

The overall objective of this dissertation was to develop a comprehensive method to estimate radiation dose to the lens of the eye for patients receiving CT scans of the head. This research is comprised of a physics component, in which a lens dosimetry model was derived for head CT, and a clinical component, which involved the application of that dosimetry model to patient data.

The physics component includes experiments related to the physical measurement of the radiation dose to the lens by various types of dosimeters placed within anthropomorphic phantoms. These dosimeters include high-sensitivity MOSFETs, TLDs, and radiochromic film. The six anthropomorphic phantoms used in these experiments range in age from newborn to adult.

First, the lens dose from five clinically relevant head CT protocols was measured in the anthropomorphic phantoms with MOSFET dosimeters on two state-of-the-art CT scanners. The volume CT dose index (CTDIvol), which is a standard CT output index, was compared to the measured lens doses. Phantom age-specific CTDIvol-to-lens dose conversion factors were derived using linear regression analysis. Since head size can vary among individuals of the same age, a method was derived to estimate the CTDIvol-to-lens dose conversion factor using the effective head diameter. These conversion factors were derived for each scanner individually, but also were derived with the combined data from the two scanners as a means to investigate the feasibility of a scanner-independent method. Using the scanner-independent method to derive the CTDIvol-to-lens dose conversion factor from the effective head diameter, most of the fitted lens dose values fell within 10-15% of the measured values from the phantom study, suggesting that this is a fairly accurate method of estimating lens dose from the CTDIvol with knowledge of the patient’s head size.

Second, the dose reduction potential of organ-based tube current modulation (OB-TCM) and its effect on the CTDIvol-to-lens dose estimation method was investigated. The lens dose was measured with MOSFET dosimeters placed within the same six anthropomorphic phantoms. The phantoms were scanned with the five clinical head CT protocols with OB-TCM enabled on the one scanner model at our institution equipped with this software. The average decrease in lens dose with OB-TCM ranged from 13.5 to 26.0%. Using the size-specific method to derive the CTDIvol-to-lens dose conversion factor from the effective head diameter for protocols with OB-TCM, the majority of the fitted lens dose values fell within 15-18% of the measured values from the phantom study.

Third, the effect of gantry angulation on lens dose was investigated by measuring the lens dose with TLDs placed within the six anthropomorphic phantoms. The 2-dimensional spatial distribution of dose within the areas of the phantoms containing the orbit was measured with radiochromic film. A method was derived to determine the CTDIvol-to-lens dose conversion factor based upon distance from the primary beam scan range to the lens. The average dose to the lens region decreased substantially for almost all the phantoms (ranging from 67 to 92%) when the orbit was exposed to scattered radiation compared to the primary beam. The effectiveness of this method to reduce lens dose is highly dependent upon the shape and size of the head, which influences whether or not the angled scan range coverage can include the entire brain volume and still avoid the orbit.

The clinical component of this dissertation involved performing retrospective patient studies in the pediatric and adult populations, and reconstructing the lens doses from head CT examinations with the methods derived in the physics component. The cumulative lens doses in the patients selected for the retrospective study ranged from 40 to 1020 mGy in the pediatric group, and 53 to 2900 mGy in the adult group.

This dissertation represents a comprehensive approach to lens of the eye dosimetry in CT imaging of the head. The collected data and derived formulas can be used in future studies on radiation-induced cataracts from repeated CT imaging of the head. Additionally, it can be used in the areas of personalized patient dose management, and protocol optimization and clinician training.