877 resultados para Águas residuais - Purificação - Tratamento biológico


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pós-graduação em Ciências Farmacêuticas - FCFAR

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil - FEIS

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study was developed to evaluate the performance of different coagulant and pH dosages by applying the use of Dissolved Air Flotation (FAD) to enable its use in effluent treatment of the extraction process of palm oil. The study was developed in the laboratory, where studies about emulsions stability were made for the production of a synthetic effluent which best suit the characteristics of raw effluent. The synthetic water that would be used in the tests of FAD was produced, once the stability and characterization which best approached the raw wastewater was obtained. Trials tested three coagulant doses, combined with various pH ranges and five upward velocities (Va), finding an optimal range of this combination. Some operating parameters such as time and gradient of rapid mixing (20 s / 1000 s-1), time and gradient flotation (15 min / 60 s-1), chamber pressure saturation (450 kPa) and recirculation rate (20%) were set. In this way, samples were collected for analysis of the removal of turbidity parameters, suspended solids and oils and greases. This one is obtained by a correlation turbidity x oils and greases, referring to the previous analysis. The degree of removal obtained were 73,97% for turbidity, 51,4% for total suspended solids and 86,2% for oils and greases. Removal rates may be increased in later studies, by ranging the velocity gradient and flocculation parameters and the recirculation ratio, and by using lower flotation speeds to these effluent characteristics.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Cassava wastewater, generated during cassava processing, is a highly polluting and toxic waste. This study aimed to assess the relationship of cassava treatment efficiency in two aerobic sequencing batch reactors, cylindrical plastics (31cm height x 9cm diameter), with 2.0 liters capacity and 1.5 liters of work volume, a ratio of diameter and height of the liquid 1:2.5, with a running time of 24 hours and stoppage aeration for 16 hours with average feed of 2,500 and 6,000 mg COD. L -1. COD, pH, SVI and F/M were analyzed. The results obtained in the two reactors showed an average reduction of 94.1% and 76.8% organic content, respectively; pH values showed a rising in the output pH values compared to entry ones; SVI values obtained: 54.1 mL/g, 99.3 mL/g, respectively in a F/M ratio values worked out of 0.4 d-1 and 1,1 d-1 , respectively. The results demonstrated that the process has generated considerable saving in energy consumption compared to traditional continuous systems, was efficient and did not affect the efficiency overly of the reactor.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Water and soil pollution caused by the waste from the swine production causes severe environmental impacts in producing areas. An efficient alternative to reduce these impacts can be the use of high-rate anaerobic reactors. In this work, it was evaluated the effect of the swine wastewater with total suspended solids concentrations around 6.000 mg.L-1 in the anaerobic baffled reactor with three compartments. The volume of the first compartment was 210 L and of the second and third ones of 160 L. The anaerobic baffled reactor was submitted at hydraulic detention times of 56, 28 and 18 hours and to organic load rates of 5.0 to 10.1 g total COD (L.d)(-1). The highest total COD removals, of 42 to 68%, and volumetric methane productions, of 0.261 to 0.454 L CH4 (L reactor d)(-1), occurred in the second compartment.