972 resultados para vanillin assay
Resumo:
The drug discovery process is facing new challenges in the evaluation process of the lead compounds as the number of new compounds synthesized is increasing. The potentiality of test compounds is most frequently assayed through the binding of the test compound to the target molecule or receptor, or measuring functional secondary effects caused by the test compound in the target model cells, tissues or organism. Modern homogeneous high-throughput-screening (HTS) assays for purified estrogen receptors (ER) utilize various luminescence based detection methods. Fluorescence polarization (FP) is a standard method for ER ligand binding assay. It was used to demonstrate the performance of two-photon excitation of fluorescence (TPFE) vs. the conventional one-photon excitation method. As result, the TPFE method showed improved dynamics and was found to be comparable with the conventional method. It also held potential for efficient miniaturization. Other luminescence based ER assays utilize energy transfer from a long-lifetime luminescent label e.g. lanthanide chelates (Eu, Tb) to a prompt luminescent label, the signal being read in a time-resolved mode. As an alternative to this method, a new single-label (Eu) time-resolved detection method was developed, based on the quenching of the label by a soluble quencher molecule when displaced from the receptor to the solution phase by an unlabeled competing ligand. The new method was paralleled with the standard FP method. It was shown to yield comparable results with the FP method and found to hold a significantly higher signal-tobackground ratio than FP. Cell-based functional assays for determining the extent of cell surface adhesion molecule (CAM) expression combined with microscopy analysis of the target molecules would provide improved information content, compared to an expression level assay alone. In this work, immune response was simulated by exposing endothelial cells to cytokine stimulation and the resulting increase in the level of adhesion molecule expression was analyzed on fixed cells by means of immunocytochemistry utilizing specific long-lifetime luminophore labeled antibodies against chosen adhesion molecules. Results showed that the method was capable of use in amulti-parametric assay for protein expression levels of several CAMs simultaneously, combined with analysis of the cellular localization of the chosen adhesion molecules through time-resolved luminescence microscopy inspection.
Resumo:
A rapid indirect enzyme-linked immunosorbent assay (ELISA) was developed for measuring antibodies against Anaplasma marginale using a partially soluble antigen prepared from semi-purified initial bodies from erythrocytes with 80.0% of rickettsiaemia. This technique utilized alkaline phosphatase and p-nitrophenyl phosphate as reaction indicators. The high sensitivity (100.0%) was confirmed with sera from 100 calves experimentally-infected with A. marginale. All of these animals showed seroconversion before or at the same time of the first rickettsiaemia or even when it was not detected. Also the elevated specificity (94.0%) was confirmed by the low percentage of cross-reactions with sera from animals experimentally-infected with Babesia bigemina and Babesia bovis (1.4 and 6.6%, respectively). Performances of ELISA and indirect fluorescent antibody test (IFAT) with 324 sera from enzootically stable area did not show statistical difference (P>0.05), since the former showed 96.9% and the latter 97.2% of positive reactions. The advantage of this ELISA is a shorter execution time than others developed until now, allowing more samples to be analyzed.
Resumo:
Visceral leishmaniasis is an emergent zoonosis with an increasing number of new cases in Brazil where the domestic dog is an important parasite reservoir in the infectious cycle of Leishmania chagasi. An enzyme-linked immunosorbent assay (ELISA), based upon the use of a total soluble antigenic preparation of L. chagasi, was adapted for the detection of IgM antibodies in the serum of infected dogs. Optimal dilutions of the antigen, using positive and negative reference sera, were determined by checkboard titrations. The specificity and sensitivity of the ELISA were 100 %. A total of 110 serum samples were taken from dogs in Belo Horizonte, Minas Gerais, Brazil, and examined for anti-L. chagasi IgM antibody by ELISA and indirect fluorescent antibody test (IFAT). About 25% (n=27) of all the dogs tested were found serologically positive for L. chagasi by IFAT, while 89.09% (n=98) were seropositive by ELISA. The results obtained by ELISA and IFAT were significantly different (P<0.01). The combined use of ELISA and IFAT is recommended in order to enable veterinary services to more efficiently detect canine visceral leishmaniasis.
Resumo:
An indirect enzyme-linked immunosorbent assay was developed to detect antigen-specific secretory IgA antibodies to Campylobacter fetus subsp. venerealis in bovine vaginal mucus with a protein extract of the Campylobacter fetus subsp. venerealis by the acid glycine extraction method. Mean optical density measurement (λ=450 nm) was 0.143±0.9. The most immunoreactive protein bands of the Campylobacter fetus subsp. venerealis or Campylobacter fetus subsp. fetus recognized by IgA in immunoblotting, using bovine vaginal mucus samples, migrate at 42.6 kDa. The protein that migrates at 93 kDa was recognized exclusively for C. fetus subsp. venerealis. A positive vaginal mucus sample of a cow from negative herd recognized antigens of C. jejuni subsp. jejuni e C. fetus subsp. fetus.
Resumo:
This study aimed to evaluate the interference of tuberculin test on the gamma-interferon (INFg) assay, to estimate the sensitivity and specificity of the INFg assay in Brazilian conditions, and to simulate multiple testing using the comparative tuberculin test and the INFg assay. Three hundred-fifty cattle from two TB-free and two TB-infected herds were submitted to the comparative tuberculin test and the INFg assay. The comparative tuberculin test was performed using avian and bovine PPD. The INFg assay was performed by the BovigamTM kit (CSL Veterinary, Australia), according to the manufacturer's specifications. Sensitivity and specificity of the INFg assay were assessed by a Bayesian latent class model. These diagnostic parameters were also estimate for multiple testing. The results of INFg assay on D0 and D3 after the comparative tuberculin test were compared by the McNemar's test and kappa statistics. Results of mean optical density from INFg assay on both days were similar. Sensitivity and specificity of the INFg assay showed results varying (95% confidence intervals) from 72 to 100% and 74 to 100% respectively. Sensitivity of parallel testing was over 97.5%, while specificity of serial testing was over 99.7%. The INFg assay proved to be a very useful diagnostic method.
Resumo:
This paper reports on the development and validation of a loop-mediated isothermal amplification assay (LAMP) for the rapid and specific detection of Actinobacillus pleuropneumoniae (A. pleuropneumoniae). A set of six primers were designed derived from the dsbE-like gene of A.pleuropneumoniae and validate the assay using 9 A. pleuropneumoniae reference/field strains, 132 clinical isolates and 9 other pathogens. The results indicated that positive reactions were confirmed for all A. pleuropneumoniae strains and specimens by LAMP at 63ºC for 60 min and no cross-reactivity were observed from other non-A.pleuropneumoniae including Haemophilus parasuis, Escherichia coli, Pasteurella multocida, Bordetella bronchiseptica, Streptococcus suis, Salmonella enterica, Staphylococcus, porcine reproductive and respiratory syndrome virus (PRRSV), and Pseudorabies virus. The detection limit of the conventional PCR was 10² CFU per PCR test tube, while that of the LAMP was 5 copies per tube. Therefore, the sensitivity of LAMP was higher than that of PCR. Moreover, the LAMP assay provided a rapid yet simple test of A. pleuropneumoniae suitable for laboratory diagnosis and pen-side detection due to ease of operation and the requirement of only a regular water bath or heat block for the reaction.
Resumo:
Information gained from the human genome project and improvements in compound synthesizing have increased the number of both therapeutic targets and potential lead compounds. This has evolved a need for better screening techniques to have a capacity to screen number of compound libraries against increasing amount of targets. Radioactivity based assays have been traditionally used in drug screening but the fluorescence based assays have become more popular in high throughput screening (HTS) as they avoid safety and waste problems confronted with radioactivity. In comparison to conventional fluorescence more sensitive detection is obtained with time-resolved luminescence which has increased the popularity of time-resolved fluorescence resonance energy transfer (TR-FRET) based assays. To simplify the current TR-FRET based assay concept the luminometric homogeneous single-label utilizing assay technique, Quenching Resonance Energy Transfer (QRET), was developed. The technique utilizes soluble quencher to quench non-specifically the signal of unbound fraction of lanthanide labeled ligand. One labeling procedure and fewer manipulation steps in the assay concept are saving resources. The QRET technique is suitable for both biochemical and cell-based assays as indicated in four studies:1) ligand screening study of β2 -adrenergic receptor (cell-based), 2) activation study of Gs-/Gi-protein coupled receptors by measuring intracellular concentration of cyclic adenosine monophosphate (cell-based), 3) activation study of G-protein coupled receptors by observing the binding of guanosine-5’-triphosphate (cell membranes), and 4) activation study of small GTP binding protein Ras (biochemical). Signal-to-background ratios were between 2.4 to 10 and coefficient of variation varied from 0.5 to 17% indicating their suitability to HTS use.
Resumo:
Glucose-6-phosphate dehydrogenase (G6PD) activity and the affinity for its substrate glucose-6-phosphate were investigated under conditions similar to the physiological environment in terms of ionic strength (I: 0.188), cation concentration, pH 7.34, and temperature (37oC). A 12.4, 10.4 and 21.4% decrease was observed in G6PD B, G6PD A+ and G6PD A- activities, respectively. A Km increase of 95.1, 94.4 and 95.4% was observed in G6PD B, G6PD A+ and G6PD A-, respectively, leading to a marked decrease in affinity. In conclusion, the observation of the reduced activity and affinity for its natural substrate reflects the actual pentose pathway rate. It also suggests a much lower NADPH generation, which is crucial mostly in G6PD-deficient individuals, whose NADPH availability is poor.
Resumo:
We have developed a polymerase chain reaction (PCR) assay which distinguishes genotype F from the other genotypes of hepatitis B virus (HBV). The method was used to characterize HBV strains isolated in urban areas of the Brazilian Amazon. DNA was amplified in 54 of a total of 78 HBsAg-positive serum samples, using universal, non-genotype-specific primers. Only 4 (7.4%) were identified as genotype F by our genotype-specific PCR assay. This proportion is notably lower than that previously reported in Argentina, Venezuela, Peru, and Central America.
Resumo:
To assess the clinical relevance of a semi-quantitative measurement of human cytomegalovirus (HCMV) DNA in renal transplant recipients within the typical clinical context of a developing country where virtually 100% of both receptors and donors are seropositive for this virus, we have undertaken HCMV DNA quantification using a simple, semi-quantitative, limiting dilution polymerase chain reaction (PCR). We evaluated this assay prospectively in 52 renal transplant patients from whom a total of 495 serial blood samples were collected. The samples scored HCMV positive by qualitative PCR had the levels of HCMV DNA determined by end-point dilution-PCR. All patients were HCMV DNA positive during the monitoring period and a diagnosis of symptomatic infection was made for 4 of 52 patients. In symptomatic patients the geometric mean of the highest level of HCMV DNAemia was 152,000 copies per 106 leukocytes, while for the asymptomatic group this value was 12,050. Symptomatic patients showed high, protracted HCMV DNA levels, whereas asymptomatic patients demonstrated intermittent low or moderate levels. Using a cut-off value of 100,000 copies per 106 leukocytes, the limiting dilution assay had sensitivity of 100%, specificity of 92%, a positive predictive value of 43% and a negative predictive value of 100% for HCMV disease. In this patient group, there was universal HCMV infection but relatively infrequent symptomatic HCMV disease. The two patient groups were readily distinguished by monitoring with the limiting dilution assay, an extremely simple technology immediately applicable in any clinical laboratory with PCR capability.
Resumo:
The tripeptide Hip-His-Leu was used to standardize a fluorimetric method to measure tissue angiotensin-converting enzyme (ACE) activity in rats. The fluorescence of the o-phthaldialdehyde-His-Leu adduct was compared in the presence and absence of the homogenate (25 µl) to determine whether the homogenate from different tissues interfered with the fluorimetric determination of the His-Leu product. Only homogenates from lung and renal medulla and cortex showed significantly altered fluorescence intensity. To overcome this problem, the homogenate from these tissues were diluted 10 times with assay buffer. The specificity of the assay was demonstrated by the inhibition of ACE activity with 3 µM enalaprilat (MK-422). There was a linear relationship between product formation and incubation time for up to 90 min for homogenates of renal cortex and medulla and liver, for up to 60 min for ventricles and adrenals and for up to 30 min for the aorta, lung and atrium homogenates. In addition, there was a linear relationship between product formation and the amount of protein in the homogenates within the following range: lung, 30-600 µg; renal cortex and medulla, 40-400 µg; atrium and ventricles, 20-200 µg; adrenal, 20-100 µg; aorta, 5-100 µg; liver, 5-25 µg. No peptidase activity against the His-Leu product (31 nmol), assayed in borate buffer (BB), was detected in the different homogenates except the liver homogenate, which was inhibited by 0.1 mM r-chloromercuribenzoic acid. ACE activity in BB was higher than in phosphate buffer (PB) due, at least in part, to a greater hydrolysis of the His-Leu product in PB. ACE activity of lung increased 20% when BB plus Triton was used. Enzyme activity was stable when the homogenates were stored at -20o or -70oC for at least 30 days. These results indicate a condition whereby ACE activity can be easily and efficiently assayed in rat tissue samples homogenized in BB using a fluorimetric method with Hip-His-Leu as a substrate.
Resumo:
In patients with uremia, intact parathyroid hormone (PTH) measurement appears to overestimate the biologically active hormone in circulation. The recent description of the accumulation in these patients of a non-intact PTH form measured by the standard immunometric assays, re-opened the question. In this study we submitted serum samples from 7 patients with primary hyperparathyroidism (PHP) and from 10 patients with hyperparathyroidism secondary to chronic renal failure (SHP) to preparative HPLC in order to discriminate the molecular forms measured by our currently used immunofluorometric assay for intact PTH. The elution profile obtained with the HPLC system showed two clearly defined peaks, the first one corresponding to a lower molecular weight form, and the second to the intact PTH (1-84) form. In patients with SHP the area under the curve for the first peak (mean 29.5%, range 20.6 to 40.4%) was significantly greater than that observed for patients with PHP (mean 15.6%, range 5.6 to 21.9%). This confirms previous studies showing accumulation of molecular forms of slightly lower molecular weight, presumably PTH (7-84), in patients with SHP and, to a lesser extent, in patients with PHP. The real necessity of assays that discriminate between these two molecular forms is debatable.
Resumo:
Measurement of telomerase activity in clinically obtained tumor samples may provide important information for use as both a diagnostic marker and a prognostic indicator for patient outcome. In order to evaluate telomerase activity in tumor tissue without radiolabeling the product, we developed a simple telomeric repeat amplification protocol-silver-staining assay that is less time-consuming, is safe and requires minimal equipment. In addition, we determined the sensitivity of the silver-staining method by using extracts of telomerase-positive thyroid carcinoma cell lines which were serially diluted from 5,000 to 10 cells. Telomerase activity was also assayed in 19 thyroid tumors, 2 normal controls and 27 bone marrow aspirates. The results indicate that the technique permits the detection of telomerase activity from 5000 to as few as 10 cells. We propose that it could be immediately applicable in many laboratories due to the minimal amount of equipment required.
Resumo:
Intraoperative parathyroid hormone (IO-PTH) measurements have been proposed to improve operative success rates in primary, secondary and tertiary hyperparathyroidism (PHP, SHP and THP). Thirty-one patients requiring parathyroidectomy were evaluated retrospectively from June 2000 to January 2002. Sixteen had PHP, 7 SHP and 8 THP. Serum samples were taken at times 0 (before resection), 10, 20 and 30 min after resection of each abnormal parathyroid gland. Samples from 28 patients were frozen at -70ºC for subsequent tests, whereas samples from three patients were tested while surgery was being performed. IO-PTH was measured using the Elecsys immunochemiluminometric assay (Roche, Mannheim, Germany). The time necessary to perform the assay was 9 min. All samples had a second measurement taken by a conventional immunofluorimetric method. We considered as cured patients who presented normocalcemia in PHP and THP, and normal levels of PTH in SHP one month after surgery and who remained in this condition throughout the follow-up of 1 to 20 months. When rapid PTH assay was compared with a routine immunofluorimetric assay, excellent correlation was observed (r = 0.959, P < 0.0001). IO-PTH measurement showed a rapid average decline of 78.8% in PTH 10 min after adenoma resection in PHP and all patients were cured. SHP patients had an average IO-PTH decrease of 89% 30 min after total parathyroidectomy and cure was observed in 85.7%. THP showed an average IO-PTH decrease of 91.9%, and cure was obtained in 87.5% of patients. IO-PTH can be a useful tool that might improve the rate of successful treatment of PHP, SHP and THP.
Resumo:
Streptokinase, a 47-kDa protein isolated and secreted by most group A, C and G ß-hemolytic streptococci, interacts with and activates human protein plasminogen to form an active complex capable of converting other plasminogen molecules to plasmin. Our objective was to compare five streptokinase formulations commercially available in Brazil in terms of their activity in the in vitro tests of euglobulin clot formation and of the hydrolysis of the plasmin-specific substrate S-2251™. Euglobulin lysis time was determined using a 96-well microtiter plate. Initially, human thrombin (10 IU/ml) and streptokinase were placed in individual wells, clot formation was initiated by the addition of plasma euglobulin, and turbidity was measured at 340 nm every 30 s. In the second assay, plasminogen activation was measured using the plasmin-specific substrate S-2251™. Streptase™ was used as the reference formulation because it presented the strongest fibrinolytic activity in the euglobulin lysis test. The Unitinase™ and Solustrep™ formulations were the weakest, showing about 50% activity compared to the reference formulation. All streptokinases tested activated plasminogen but significant differences were observed. In terms of total S-2251™ activity per vial, Streptase™ (75.7 ± 5.0 units) and Streptonase™ (94.7 ± 4.6 units) had the highest activity, while Unitinase™ (31.0 ± 2.4 units) and Strek™ (32.9 ± 3.3 units) had the weakest activity. Solustrep™ (53.3 ± 2.7 units) presented intermediate activity. The variations among the different formulations for both euglobulin lysis test and chromogenic substrate hydrolysis correlated with the SDS-PAGE densitometric results for the amount of 47-kDa protein. These data show that the commercially available clinical streptokinase formulations vary significantly in their in vitro activity. Whether these differences have clinical implications needs to be investigated.