984 resultados para synchronized phasor measurement unit
Resumo:
The objective was to evaluate the influence of varying plasma progesterone (P(4)) concentrations throughout the luteal phase in dairy cows on PGF(2 alpha) production (assessed as plasma concentrations of 13,14-dihydro-15-keto-PGF(2 alpha); PGFM) following treatment with estradiol-17 beta (E(2)) or oxytocin (OT). In all experiments, time of ovulations was synchronized with the OvSynch protocol and Day 0 corresponded to day of second GnRH injection. In Experiment 1, non-lactating dairy cows on Day 6 remained non-treated (n = 9), received 20 mg LH (n = 7), or had ovarian follicles larger than 6 mm aspirated (n = 8). In Experiment 2, cows on Day 6 were untreated (n = 9) or received 5000 IU hCG (n = 10). In Experiments 1 and 2, all cows received 3 mg E(2) on Day 17, and blood samples were collected every 30 min from 2h before to 10h after E(2). Experiment 3 was conducted in two periods, each from Days 0 to 17 of the estrous cycle. At the end of Period 1, animals switched treatments in a crossover arrangement. Animals in Group 2/8 (n = 4) received 2 kg/d of concentrate in the first period and 8 kg/d in the second period. Animals in Group 8/2 (n = 7) received the alternate sequence. Blood was collected daily for measurement Of P(4) 4 h after concentrate feeding. On Day 17, blood was collected from 1 h before to 1 h after a 100 IU OT injection. In Experiment 1, both plasma P(4) and release Of PGF(2 alpha) were similar between LH-treated and control cows (P > 0.10). In Experiment 2, plasma P4 was elevated to a greater extent on Day 17 in cows treated with hCG (P < 0.05) and plasma PGFM was also greater in hCG-treated animals (treatment x time interaction; P < 0.05). In Experiment 3, there was a group x period interaction (P < 0.01) for plasma P(4), indicating that less concentrate feeding was associated with greater plasma P(4). Release of PGF(2 alpha) in response to OT was greater for cows receiving less concentrate (group x period interaction; P < 0.05). In conclusion, dairy cows with more elevated blood P(4) concentrations released more PGF(2 alpha) in response to E(2) or OT. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
Objectives. The objectives of this study were to assess the accuracy of working length determination using 3 electronic apex locators and direct digital radiography and to compare the results with those obtained using the visual method (control measurement). Study design. Twenty extracted human maxillary premolars were selected: 17 two-rooted and 3 single-rooted (total of 37 canals). Working length was measured using electronic apex locators Elements Diagnostic, Root ZX, and Just II. Subsequently, teeth were positioned in the alveolar bone of a dry skull and submitted to direct digital radiography. A variation of +/- 1 mm was considered as acceptable. Results were analyzed using the Wilcoxon and the chi(2) tests. Results. Results presented an accuracy of 94.6% for Elements Diagnostic, 91.9% for Root ZX, 73.0% for Just II, and 64.9% for direct digital radiography when considering the margin of +/- 1 mm in relation to the control measurement. Comparisons with the actual control measurements resulted in accuracy results of 13.51%, 13.51%, 10.10%, and 2.70%, respectively. Conclusions. Root ZX and Elements Diagnostic are more accurate in determining working length when compared with Just II and Schick direct digital radiography. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;111:e44-e49)
Resumo:
This publication is a support and resource document for the "National Action Plan for Promotion, Prevention and Early Intervention for Mental Health 2000". It includes indicators, measurement tools and databases relevant to assessing the implementation of the outcomes and strategies identified in the action plan.
Resumo:
Purpose: Chipping within veneering porcelain has resulted in high clinical failure rates for implant-supported zirconia (yttria-tetragonal zirconia polycrystals [Y-TZP]) bridges. This study evaluated the reliability and failure modes of mouth-motion step-stress fatigued implant-supported Y-TZP versus palladium-silver alloy (PdAg) three-unit bridges. Materials and Methods: Implant-abutment replicas were embedded in polymethylmethacrylate resin. Y-TZP and PdAg frameworks, of similar design (n = 21 each), were fabricated, veneered, cemented (n = 3 each), and Hertzian contact-tested to obtain ultimate failure load. In each framework group, 18 specimens were distributed across three step-stress profiles and mouth-motion cyclically loaded according to the profile on the lingual slope of the buccal cusp of the pontic. Results: PdAg failures included competing flexural cracking at abutment and/or connector area and chipping, whereas Y-TZP presented predominantly cohesive failure within veneering porcelain. Including all failure modes, the reliability (two-sided at 90% confidence intervals) for a ""mission"" of 50,000 and 100,000 cycles at 300 N load was determined (Alta Pro, Reliasoft, Tucson, AZ, USA). No difference in reliability was observed between groups for a mission of 50,000. Reliability remained unchanged for a mission of 100,000 for PdAg, but significantly decreased for Y-TZP. Conclusions: Higher reliability was found for PdAg for a mission of 100,000 cycles at 300 N. Failure modes differed between materials.
Resumo:
We assessed the feasibility of obtaining probe microphone measurements of hearing aids at a distance. Face-to-face and remote probe microphone measurements were carried out in 60 hearing aid users (mean age 67 yrs) with uni- or bilateral hearing losses (105 ears tested). The participant and a facilitator were located in a room equipped with a probe microphone system interfaced to a PC. Desktop videoconferencing and application sharing was used to allow an audiologist in another room to instruct the facilitator and control the equipment via the LAN. There were significant correlations between face-to-face and remote real ear unaided response (REUR), aided response (REAR) and insertion gain (REIG) at seven discrete frequencies from 250 to 6000 Hz. Differences between face-to-face and remote responses were within the reported variability for probe microphone measurements themselves. The results show that remote probe microphone measurements are feasible and might improve the quality of public hearing aid services and professional training in Brazil.
Resumo:
P>The aim of this study was to validate an original portable device to measure attachment retention of implant overdentures both in the lab and in clinical settings. The device was built with a digital force measurement gauge (Imada) secured to a vertical wheel stand associated with a customized support to hold and position the denture in adjustable angulations. Sixteen matrix and patrix cylindrical stud attachments (Locator (R)) were randomly assigned as in vitro test specimens. Attachment abutments were secured in an implant analogue hung to the digital force gauge or to the load cell of a traction machine used as the gold standard (Instron Universal Testing Machine). Matrices were secured in a denture duplicate attached to the customized support, permitting reproducibility of their position on both pulling devices. Attachment retention in the axial direction was evaluated by measuring maximum dislodging force or peak load during five consecutive linear dislodgments of each attachment on both devices. After a wear simulation, retention was measured again at several time periods. The peak load measurements with the customized Imada device were similar to those obtained with the gold standard Instron machine. These findings suggest that the proposed portable device can provide accurate information on the retentive properties of attachment systems for removable dental prostheses.