961 resultados para standard molar enthalpy of combustion


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We intend to divulge an easy experiment that permits the determination of molar masses of various compounds by cryoscopy. The major advantage of this is the use of the tert-butyl alcohol as a solvent, which requires simple apparatus and easy procedures. The melting point of this alcohol is around 25 ºC, which makes it easy to freeze and then melt the solutions. This solvent has a high cryoscopic constant and is miscible with both polar and non-polar compounds. The molar masses of acetone, water, chloroform, dichloro-methane, ethanol, hexane, carbon tetrachloride and toluene were determined. The results were good except for water. Even though there are reliable techniques of molar mass determination nowadays, this method is still frequently taught in undergraduate courses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The quality of the gasoline utilized for fueling internal combustion engines with spark ignition is directly affected by the gasoline's properties. Thus, the fuel's properties must be in perfect equilibrium to allow the engine to perform optimally, not only insofar as fuel consumption is concerned, but also in order to reduce the emission of pollutants. Vapor pressure and vaporization enthalpy are important properties of a gasoline determining the fuel's behavior under different operating conditions in internal combustion engines. The study reported here involved the development of a device to determine the vapor pressure and the vaporization enthalpy of formulations containing volumes of 5, 15 and 25% of ethanol in four base gasolines (G1, G2, G3 and G4). The chemical composition of these gasolines was determined using a gas chromatographer equipped with a flame ionization detector (FID).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The hydrated sodium salt of EDTA, Na2H2Y·2H2O, cannot be used as a primary standard for titrations due to uncertainties in the water content. An alkalimetric titration of the homogenized solid in the presence of a small excess of BaCl2·2H2O allows one to titrate quantitatively the released two hydrogen cations with end-point indication by phenolphthalein or potentiometry. This leads one to calculate the average molar mass of the reagent and its water content, allowing to use it to prepare EDTA standard solutions. One titrated sample led to the formula Na2H2Y·1.876 H2O, and 370.01 g.mol-1 for the average molar mass.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We estimate the determinants of capital intensity in Japan and the US, characterized by striking different paths. We augment an otherwise standard Constant Elasticity of Substitution (CES) model with demand-side considerations, which we find especially relevant in the US. In this augmented setting, the elasticity of substitution between capital and labor is placed around 0.85 in Japan, and 0.30 in the US. We also find evidence of biased technical change, which is capital-saving in Japan but labor-saving in the US. These differences help us explain the diverse experience in the capital deepening process of these economies, and lead us to conclude that demand-side drivers may also be relevant to account for different growth experiences. A close look at the nature of technological change is also needed before designing one-size-fits-all industrial, economic growth, and/or labor market policies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, fast and sensitive spectrophotometric method for the determination of cefaclor in pharmaceutical raw and dosage forms based on reaction with ninhydrin is developed, optimized and validated. The purple color (Ruhemenn's purple) that resulted from the reaction was stabilized and measured at 560 nm. Beer's law is obeyed in the concentration range of 4-80 µg mL-1 with molar absorptivity of 1.42 × 10(5) L mole-1 cm-1. All variables including the reagent concentration, heating time, reaction temperature, color stability period, and cefaclor/ninhydrin ratio were studied in order to optimize the reaction conditions. No interference was observed from common pharmaceutical adjuvant. The developed method is easy to use, accurate and highly cost-effective for routine studies relative to HPLC and other techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, the combustion process of ammonium dinitramide, ADN, has been modeled in two different situations: decomposition in open environment, with abundant air and decomposition in a rocket motor internal environmental conditions. The profiles of the two processes were achieved, based on molar fractions of the species that compose the products of ADN combustion. The velocity of formation and quantity of species in the open environment was bigger than the ones in the rocket motor environment, showing the effect of the different atmosphere in the reactions kinetics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid and low cost method to determine Cr(VI) in soils based upon alkaline metal extraction at room temperature is proposed as a semi-quantitative procedure to be performed in the field. A color comparison with standards with contents of Cr(VI) in the range of 10 to 150 mg kg-1 was used throughout. For the different types of soils studied, more than 75% of the fortified soluble Cr(VI) were recovered for all levels of spike tested for both the proposed and standard methods. Recoveries of 83 and 99% were obtained for the proposed and the standard methods, respectively, taking into account the analysis of a heavily contaminated soil sample.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A spectrophotometric method based on the formation of ion-pair complex between haloperidol and eriochrome black T (EBT) at pH 1.85 has been described. The formed complex was extracted quantitatively into chloroform and measured at 510 nm. Infra red (IR) studies were performed to confirm the formation of ion-pair complex. Beer's law was obeyed in the concentration range of 2.0-9.0 µg mL-1 with molar absorptivity of 2.67 × 10(4) L mol-1 cm-1. The detection limit was found to be 0.18 µg mL-1. Statistical comparison of the results of the proposed method with those of the reference method shows excellent agreement and indicates no significant difference in accuracy and precision.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diclofenac is one of most frequently detected compounds in the water cycle. In this work, the effect of initial concentration, liquid inclusion complexes with β-Cyclodextrins (β-CDs) on the photodegradation of diclofenac were studied. Six phototransformation products were detected by HPLC chromatograms. UV-absorption spectra of diclofenac and phototransformation products were determined. One of the phototransformation products was identified. The degradation followed pseudo-first-order kinetics. The experiment showed that irradiation of diclofenac in the presence of β-CDs increase photodegradation rate and determined the optimal molar ratio of diclofenac to β-CDs as 1:2. The reduced photohaemolytic activity of diclofenac in the presence of β-CDs may be attributed to the sequestering and stabilizing of the radical intermediates and /or photoproducts by complexation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, precise, rapid and low-cost potentiometric method for captopril determination in pure form and in pharmaceutical preparations is proposed. Captopril present in tablets containing known quantity of drug was potentiometrically titrated in aqueous solution with NaOH using a glass pH electrode, coupled to an autotitrator. No interferences were observed in the presence of common components of the tablets as lactose, microcrystalline cellulose, croscarmellose sodium, starch and magnesium stearate. The analytical results obtained by applying the proposed method compared very favorably with those obtained by the United States Pharmacopoeia Standard procedure. Recovery of captopril from various tablet dosage formulations range from 98.0 to 102.0%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The possibility of using thiocyanate to determine iron(II) and/or iron(III) in water-acetone mixture has been re-examined as part of a systematic and comparative study involving metallic complexes of pseudohalide ligands. Some parameters that affect the complete oxidation of the ferrous cations, their subsequent complexation and the system stability have been studied to optimize the experimental conditions. Our results show the viability and potentiality of this simply methodology as an alternative analytical procedure to determine iron cations with high sensitivity, precision and accuracy. Studies on the calibration, stability, precision, and effect of various different ions have been carried out by using absorbance values measured at 480 nm. The analytical curve for the total iron determination obeys Beer's law (r = 0.9993), showing a higher sensitivity (molar absorptivity of 2.10x10(4) L cm-1 mol-1) when compared with other traditional systems (ligands) or even with the "similar" azide ion [1.53x10(4) L cm-1 mol-1, for iron-III/azide complexes, in 70% (v/v) tetrahydrofuran/water, at 396 nm]. Under such optimized experimental conditions, it is possible to determine iron in the concentration range from 0.5 to 2 ppm (15-65% T for older equipments, quartz cells of 1.00 cm). Analytical applications have been tested for some different materials (iron ores), also including pharmaceutical products for anemia, and results were compared with atomic absorption determinations. Very good agreement was obtained with these two different techniques, showing the potential of the present experimental conditions for the total iron spectrophotometric determinations (errors < 5%). The possibility of iron speciation was made evident by using another specific and auxiliary method for iron(II) or (III).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a new, simple and sensitive method for arsenic determination in soil is proposed. This is based on the reduction of silver (I) and iron (III) ions by arsine followed by a complexation reaction of iron (II) with the spectrophotometric reagent Br-PADAP 2-(5-bromo-2-pyridylazo)-5-di-ethylaminophenol. Arsenic determination with a Sandell's sensitivity of 3.1 10-4 cm-2, linear range from 0.1 µg ml-1 to 2.0 µg ml-1 (r560 = 0.9995), molar absorptivity of 2.45 10(5) l mol-1 cm-1 and a concentration detection limit of 1.4 ng ml-1 (3s) were obtained using a 10 ml sample volume. Selectivity was increased with the use of EDTA as a masking agent. The proposed method was applied for arsenic determination in the presence of several ions amounts in digested soil samples. The results revealed that antimony (III), mercury (II), germanium (IV), platinum (IV) interferes at all analyzed proportions. The interferences can be easily removed by the use of EDTA. Precision and accuracy obtained were satisfactory with a R.S.D. < 5 %. Recovery of arsenic in soil samples varied from 95.55 to 102.70 % with a mean of 99.63 %. These results demonstrated that the proposed method is applicable for arsenic analysis in different soil samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, a new mathematical equation correction approach for overcoming spectral and transport interferences was proposed. The proposal was applied to eliminate spectral interference caused by PO molecules at the 217.0005 nm Pb line, and the transport interference caused by variations in phosphoric acid concentrations. Correction may be necessary at 217.0005 nm to account for the contribution of PO, since Atotal217.0005 nm = A Pb217.0005 nm + A PO217.0005 nm. This may be easily done by measuring other PO wavelengths (e.g. 217.0458 nm) and calculating the relative contribution of PO absorbance (A PO) to the total absorbance (Atotal) at 217.0005 nm: A Pb217.0005 nm = Atotal217.0005 nm - A PO217.0005 nm = Atotal217.0005 nm - k (A PO217.0458 nm). The correction factor k is calculated from slopes of calibration curves built up for phosphorous (P) standard solutions measured at 217.0005 and 217.0458 nm, i.e. k = (slope217.0005 nm/slope217.0458 nm). For wavelength integrated absorbance of 3 pixels, sample aspiration rate of 5.0 ml min-1, analytical curves in the 0.1 - 1.0 mg L-1 Pb range with linearity better than 0.9990 were consistently obtained. Calibration curves for P at 217.0005 and 217.0458 nm with linearity better than 0.998 were obtained. Relative standard deviations (RSD) of measurements (n = 12) in the range of 1.4 - 4.3% and 2.0 - 6.0% without and with mathematical equation correction approach were obtained respectively. The limit of detection calculated to analytical line at 217.0005 nm was 10 µg L-1 Pb. Recoveries for Pb spikes were in the 97.5 - 100% and 105 - 230% intervals with and without mathematical equation correction approach, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study examines the repertory of liturgical chant known as St. Petersburg Court Chant which emerged within the Imperial Court of St. Petersburg, Russia, and appeared in print in a number of revisions during the course of the 19th century, eventually to spread throughout the Russian Empire and even abroad. The study seeks answers to questions on the essence and composition of Court Chant, its history and liturgical background, and most importantly, its musical relationship to other repertories of Eastern Slavic chant. The research questions emerge from previous literary accounts of Court Chant (summarized in the Introduction), which have tended to be inaccurate and generally not based on critical research. The study is divided into eight main chapters. Chapter 1 provides a survey of the history of Eastern Slavic chant and the Imperial Court Chapel of St. Petersburg until 1917, with special emphasis on the history of singing traditional chant in polyphony, the status of the Court Chapel as a government authority, and its endeavours in publishing church music. Chapter 2 deals with the liturgical background of Eastern chant, the chant genres, and main repertories of Eastern Slavic chant. Chapter 3 concentrates on chant sources: it introduces the musical notations utilised, after which a typology of chant books is presented. The discussion continues with a survey of the sources of Court Chant and their content, the specimens selected for closer analysis, the comparative materials from other repertories, and ends with a commentary on some chant sources that have been excluded. The comparative sources include a specimen from around the beginning of the 12th century, a few manuscripts from the 17th century, and printed and manuscript chant books from the early 18th to early 20th century, covering the geographical area that delimits to the western Ukraine, Astrakhan, Nizhny Novgorod, and the Solovetsky Monastery. Chapter 4 presents the approach and methods used in the subsequent analytical comparisons. After a survey of the pitch organization of Eastern Slavic chant, the customary harmonization strategy of traditional chant polyphony is examined, according to which a method for meaningful analysis of the harmony is proposed. The method is based on the observation that the harmonic framework of chant polyphony derives from the standard pitch collection of monodic chant known as the Church Gamut, specific pitches of which form eight harmonic regions that behave like the usual tonalities of major and harmonic minor. Because of the considerable quantity of comparative chant forms, computer-assisted statistical methods are applied to the analysis of chant melodies. The primary chant forms and their respective comparative forms have been pre-processed into reduced chant prototypes and divided into redactions. The analyses are carried out by measuring the formal dissimilarities of the primary chant forms of the Court Chant repertory against each comparative form, and also by measuring the reciprocal dissimilarities of all chant versions in a redaction, the results of which are subjected to agglomerative hierarchical clustering in order to find out how the chant forms relate to each other. The dissimilarities are determined by applying a metric dissimilarity function that is based on the Levenshtein Distance. Chapter 5 provides the melodic and harmonic analyses of generic chants (chants used for multiple texts of different lengths), i.e., chants for stichera samoglasny and troparia, Chapter 6 of pseudo-generic chants (chants that are used for multiple texts but with certain restrictions), i.e., chants for heirmoi, prokeimena, and three other hymns, and Chapter 7 of non-generic chants, covering nine chants that in the Court repertory are not shared by multiple texts. The results are summarized and evaluated in Chapter 8. Accordingly, it can be established that, contrary to previous conceptions, melodically, Court Chant is in effect a full part of the wider Eastern Slavic chant tradition. Even if it is somewhat detached from the chant versions of the Synodal square-note chant books and the local tradition of Moscow, it is particularly close to chant forms of East Ukraine and some vernacular repertories from Russia. Respectively, the harmonization strategies of Court Chant do not show significant individuality in comparison with those of the available polyphonic comparative sources, the main difference being the part-writing, which generally conforms to western common practice standard, whereas the deviations from this tend to be more significant in other analysed repertories of polyphonic chant. Thus, insofar as the subsequent prevalence of Court Chant is not based on its forceful dissemination by authorities (as suggested in previous literature but for which little tangible evidence could be found in Chapter 1), in the present author’s interpretation, Court Chant attained its dominance principally because musically it was considered sufficiently traditional, and as a chant body supported by the government, was conveniently available in print in serviceable harmonizations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Most studies on measures of transpiration of plants, especially woody fruit, relies on methods of heat supply in the trunk. This study aimed to calibrate the Thermal Dissipation Probe Method (TDP) to estimate the transpiration, study the effects of natural thermal gradients and determine the relation between outside diameter and area of xylem in 'Valencia' orange young plants. TDP were installed in 40 orange plants of 15 months old, planted in boxes of 500 L, in a greenhouse. It was tested the correction of the natural thermal differences (DTN) for the estimation based on two unheated probes. The area of the conductive section was related to the outside diameter of the stem by means of polynomial regression. The equation for estimation of sap flow was calibrated having as standard lysimeter measures of a representative plant. The angular coefficient of the equation for estimating sap flow was adjusted by minimizing the absolute deviation between the sap flow and daily transpiration measured by lysimeter. Based on these results, it was concluded that the method of TDP, adjusting the original calibration and correction of the DTN, was effective in transpiration assessment.