968 resultados para spray-dryer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Per limitare gli effetti tossici delle Ag-NPs, si è pensato che esse possano essere utilizzate in forma di microincapsulati, in quanto le microcapsule possono avere una certa velocità di rilascio sotto specifiche condizioni. Incapsulando quindi le Ag-NPs, posso ottenere un rilascio controllato di esse, in modo da ottenere una concentrazione di esse utile allo scopo per cui vengono impiegate, evitando un sovradosaggio che non porterebbe alcun beneficio ma solo a una maggior probabilità di causare effetti tossici.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To report a case of conjunctival proliferation in a 2.5-year-old boy after initial evidence of a mild chemical injury after ocular exposure to pepper spray (oleoresin capsicum). METHODS Case report with ophthalmologic and histologic findings. RESULTS A child presented with mild conjunctival injection and chemosis without any corneal erosion after direct exposure to pepper spray. Three weeks later, a significant conjunctival proliferation was found at the limbus, which was refractory to treatment with topical corticosteroids. Finally, proliferative tissue was surgically excised without clinical recurrence during 2 months of follow-up. CONCLUSIONS We hypothesize that the young age of the patient may have been an important factor for the severe conjunctival proliferation in comparison to a mainly uncomplicated course of pepper spray injuries in most adults. We recommend the use of topical antiinflammatory treatment even in apparently mild pepper spray injuries, especially in young children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fracture properties of high-strength spray-formed Al alloys were investigated, with consideration of the effects of elemental additions such as zinc,manganese, and chromium and the influence of the addition of SiC particulate. Fracture resistance values between 13.6 and 25.6 MPa (m)1/2 were obtained for the monolithic alloys in the T6 and T7 conditions, respectively. The alloys with SiC particulate compared well and achieved fracture resistance values between 18.7 and 25.6 MPa (m)1/2. The spray-formed materials exhibited a loss in fracture resistance (KI) compared to ingot metallurgy 7075 alloys but had an improvedperformance compared to high-solute powder metallurgy alloys of similar composition. Characterization of the fracture surfaces indicated a predominantly intergranular decohesion, possibly facilitated by the presence of incoherent particles at the grain boundary regions and by the large strength differentialbetween the matrix and precipitate zone. It is believed that at the slip band-grain boundary intersection, particularly in the presence of large dispersoids and/or inclusions, microvoid nucleation would be significantly enhanced. Differences in fracture surfaces between the alloys in the T6 and T7 condition were observed and are attributed to inhomogeneous slip distribution, which results in strain localization at grain boundaries. The best overall combination of fracture resistance properties were obtained for alloys with minimum amounts of chromium and manganese additions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of cold spray coating and substrate surface preparation on crack initiation under cyclic loading have been studied on Al2024 alloy specimens. Commercially pure (CP) aluminum feedstock powder has been deposited on Al2024-T351 samples using a cold-spray coating technique known as high velocity particle consolidation. Substrate specimens were prepared by surface grit blasting or shot peening prior to coating. The fatigue behavior of both coated and uncoated specimens was then tested under rotating bend conditions at two stress levels, 180 MPa and 210 MPa. Scanning electron microscopy was used to analyze failure surfaces and identify failure mechanisms. The results indicate that the fatigue strength was significantly improved on average, up to 50% at 180 MPa and up to 38% at 210 MPa, by the deposition of the cold-sprayed CP-Al coatings. Coated specimens first prepared by glass bead grit blasting experienced the largest average increase in fatigue life over bare specimens. The results display a strong dependency of the fatigue strength on the surface preparation and cold spray parameters

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aluminum coatings were applied to 2024-T3 and 7075-T6 aluminum alloys via the Cold Spray process. The coatings were applied to substrateswith various surface preparation and Cold Spray carrier gas combinations. Some samples were coated with an additional sealant with and without a chromate conversion layer. An exhaustive corrosion analysis was then performed which utilized a number of long termand accelerated tests in order to characterize the corrosion protection of the coatings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nasal polyps and chronic rhinosinusitis are the products of an inflammatory process. Recently, fungal involvement has been thought to stimulate the development of polyps, and administration of antifungal agents was therefore considered a potential treatment. Several studies have been published indicating amphotericin B as an effective treatment for nasal polyps and chronic rhinosinusitis. The aim of our investigation was to evaluate the efficacy of intranasal applied amphotericin B on the growth of nasal polyps in a three-month, prospective, open trial. Our results show that nasal amphotericin B spray is not effective for nasal polyps and may even cause deterioration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Internal combustion engines are, and will continue to be, a primary mode of power generation for ground transportation. Challenges exist in meeting fuel consumption regulations and emission standards while upholding performance, as fuel prices rise, and resource depletion and environmental impacts are of increasing concern. Diesel engines are advantageous due to their inherent efficiency advantage over spark ignition engines; however, their NOx and soot emissions can be difficult to control and reduce due to an inherent tradeoff. Diesel combustion is spray and mixing controlled providing an intrinsic link between spray and emissions, motivating detailed, fundamental studies on spray, vaporization, mixing, and combustion characteristics under engine relevant conditions. An optical combustion vessel facility has been developed at Michigan Technological University for these studies, with detailed tests and analysis being conducted. In this combustion vessel facility a preburn procedure for thermodynamic state generation is used, and validated using chemical kinetics modeling both for the MTU vessel, and institutions comprising the Engine Combustion Network international collaborative research initiative. It is shown that minor species produced are representative of modern diesel engines running exhaust gas recirculation and do not impact the autoignition of n-heptane. Diesel spray testing of a high-pressure (2000 bar) multi-hole injector is undertaken including non-vaporizing, vaporizing, and combusting tests, with sprays characterized using Mie back scatter imaging diagnostics. Liquid phase spray parameter trends agree with literature. Fluctuations in liquid length about a quasi-steady value are quantified, along with plume to plume variations. Hypotheses are developed for their causes including fuel pressure fluctuations, nozzle cavitation, internal injector flow and geometry, chamber temperature gradients, and turbulence. These are explored using a mixing limited vaporization model with an equation of state approach for thermopyhysical properties. This model is also applied to single and multi-component surrogates. Results include the development of the combustion research facility and validated thermodynamic state generation procedure. The developed equation of state approach provides application for improving surrogate fuels, both single and multi-component, in terms of diesel spray liquid length, with knowledge of only critical fuel properties. Experimental studies are coupled with modeling incorporating improved thermodynamic non-ideal gas and fuel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spray characterization under flash boiling conditions was investigated utilizing a symmetric multi-hole injector applicable to the gasoline direct injection (GDI) engine. Tests were performed in a constant volume combustion vessel using a high-speed schlieren and Mie scattering imaging systems. Four fuels including n-heptane, 100% ethanol, pure ethanol blended with 15% iso-octane by volume, and test grade E85 were considered in the study. Experimental conditions included various ambient pressure, fuel temperature, and fuel injection pressure. Visualization of the vaporizing spray development was acquired by utilizing schlieren and laser-based Mie scattering techniques. Time evolved spray tip penetration, spray angle, and the ratio of the vapor to liquid region were analyzed by utilizing digital image processing techniques in MATLAB. This research outlines spray characteristics at flash boiling and non-flash boiling conditions. At flash boiling conditions it was observed that individual plumes merge together, leading to significant contraction in spray angle as compared to non-flash boiling conditions. The results indicate that at flash boiling conditions, spray formation and expansion of vapor region is dependent on momentum exchange offered by the ambient gas. A relation between momentum exchange and liquid spray angle formed was also observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to determine the rela­tive rate of corrosion of iron-tin alloys containing low percentages of tin. Since in the world today, a great deal of work is being done to develop large tin deposits and new methods devised to treat these ores, it is possible that the metal will become abundant and will obtain a more important position in the metal industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This MPH thesis consists of (1) literature review of the relatively new synthetic persistent organic pollutants (POP), polybrominated diphenyl ethers (PBDEs), a type of flame retardant posing a potential public health hazard, (2) Presentation of data on PBDE levels in dryer lint from Dallas, TX and Hamburg, Germany. ^ PBDEs are used as additive fire retardants in plastics, polyurethane foam and electronic equipment to reduce flammability and thus save life and property. PBDEs have been widely used beginning in the 1970s. They resemble polychlorinated biphenyls (PCBs) in structure and toxicity. PBDEs are found in environmental sediments, sludges, and wildlife and even in human blood, milk and tissues. ^ PBDEs, due to their lipophilicity, accumulate in fat and other tissues and biomagnify up the food chain, with increasing concentrations. Animal studies have suggested potential health effects including thyroid disruption, permanent learning and memory impairment, fetal malformations, developmental neurotoxicity and, at high doses, possibly cancer. ^ PBDE levels are increasing in blood and breast milk in North America, but PBDEs intake unlike PCBs appears to be not primarily through food; food PBDE levels in the U.S. are not markedly higher than in Europe yet U.S. human blood and milk levels are much higher. For this reason various exposure pathways including PBDE contaminated dust and air have been studied to better characterize routes of PBDE intake into humans. ^ The scientific literature on PBDE levels in household dust reports higher PBDE concentration in dust than that found in dryer lint; levels in the U.S are elevated compared to other countries with congeners such as BDE 47, 99, 100 and 209 predominating. The United Kingdom has elevated BDE 209 due to high usage of Deca commercial mixture. These studies suggest that indoor PBDE contamination through household dust could be a potential source of PBDE exposure and body burden especially in young children. ^ PBDE levels in dryer lint from U.S ranged from 321 to 3073 ng/g (Mean: 1138 ng/g, Median: 803 ng/g) and from Germany were from 330 to 2069 ng/g (Median: 71ng/g, Mean: 361 ng/g). High median levels in U.S samples indicate contamination of lint with PBDEs although the source of the PBDEs in lint may be from dryer electrical components or air deposition onto clothes, lint may be one source of PBDE exposure to humans. ^