946 resultados para spontaneous ventilation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We hypothesized that platelet-activating factor (PAF), a potent inflammatory mediator, could induce gas exchange abnormalities in normal humans. To this end, the effect of aerosolized PAF (2 mg/ml solution; 24 micrograms) on ventilation-perfusion (VA/Q) relationships, hemodynamics, and resistance of the respiratory system was studied in 14 healthy, nonatopic, and nonsmoking individuals (23 +/- 1 [SEM]yr) before and at 2, 4, 6, 8, 15, and 45 min after inhalation, and compared to that of inhaled lyso-PAF in 10 other healthy individuals (24 +/- 2 yr). PAF induced, compared to lyso-PAF, immediate leukopenia (P < 0.001) followed by a rebound leukocytosis (P < 0.002), increased minute ventilation (P < 0.05) and resistance of the respiratory system (P < 0.01), and decreased systemic arterial pressure (P < 0.05). Similarly, compared to lyso-PAF, PaO2 showed a trend to fall (by 12.2 +/- 4.3 mmHg, mean +/- SEM maximum change from baseline), and arterial-alveolar O2 gradient increased (by 16.7 +/- 4.3 mmHg) (P < 0.02) after PAF, because of VA/Q mismatch: the dispersion of pulmonary blood flow and that of ventilation increased by 0.45 +/- 0.1 (P < 0.01) and 0.29 +/- 0.1 (P < 0.04), respectively. We conclude that in normal subjects, inhaled PAF results in considerable immediate VA/Q inequality and gas exchange impairment. These results reinforce the notion that PAF may play a major role as a mediator of inflammation in the human lung.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We hypothesized that platelet-activating factor (PAF), a potent inflammatory mediator, could induce gas exchange abnormalities in normal humans. To this end, the effect of aerosolized PAF (2 mg/ml solution; 24 micrograms) on ventilation-perfusion (VA/Q) relationships, hemodynamics, and resistance of the respiratory system was studied in 14 healthy, nonatopic, and nonsmoking individuals (23 +/- 1 [SEM]yr) before and at 2, 4, 6, 8, 15, and 45 min after inhalation, and compared to that of inhaled lyso-PAF in 10 other healthy individuals (24 +/- 2 yr). PAF induced, compared to lyso-PAF, immediate leukopenia (P < 0.001) followed by a rebound leukocytosis (P < 0.002), increased minute ventilation (P < 0.05) and resistance of the respiratory system (P < 0.01), and decreased systemic arterial pressure (P < 0.05). Similarly, compared to lyso-PAF, PaO2 showed a trend to fall (by 12.2 +/- 4.3 mmHg, mean +/- SEM maximum change from baseline), and arterial-alveolar O2 gradient increased (by 16.7 +/- 4.3 mmHg) (P < 0.02) after PAF, because of VA/Q mismatch: the dispersion of pulmonary blood flow and that of ventilation increased by 0.45 +/- 0.1 (P < 0.01) and 0.29 +/- 0.1 (P < 0.04), respectively. We conclude that in normal subjects, inhaled PAF results in considerable immediate VA/Q inequality and gas exchange impairment. These results reinforce the notion that PAF may play a major role as a mediator of inflammation in the human lung.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Turning biases have been associated with unbalanced hemispheric dopaminergic activity, and this activity has been correlated with cue-directed behaviors. Moreover, a sexual differentiation in hippocampal dopaminergic receptors following learning has been shown. In humans, pointing responses towards the starting point is commonly used to assess the accuracy of direction estimation after locomotion. Thus, it may be of interest for the field of spatial cognition to explore human sex differences in spontaneous turning bias when a body rotation is required. To this end, male and female blindfolded subjects were guided in a linear displacement and asked to rotate in order to point in the direction of the starting position. The main finding was a massive difference between men and women. 80% of women showed a turning bias to the right when 69% of men showed a bias to the left. Moreover, these preferences were not correlated with handedness. These results suggest basic preferences associated to sex might influence male and female performance in spatial cognition. They also suggest experimental procedures may be biased in favor of male or female strategies. Therefore, such preferences should be considered in order to gain further insight into the development of more balanced procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Variables influencing serum hepatitis C virus (HCV) RNA levels and genotype distribution in individuals with human immunodeficiency virus (HIV) infection are not well known, nor are factors determining spontaneous clearance after exposure to HCV in this population. METHODS: All HCV antibody (Ab)-positive patients with HIV infection in the EuroSIDA cohort who had stored samples were tested for serum HCV RNA, and HCV genotyping was done for subjects with viremia. Logistic regression was used to identify variables associated with spontaneous HCV clearance and HCV genotype 1. RESULTS: Of 1940 HCV Ab-positive patients, 1496 (77%) were serum HCV RNA positive. Injection drug users (IDUs) were less likely to have spontaneously cleared HCV than were homosexual men (20% vs. 39%; adjusted odds ratio [aOR], 0.36 [95% confidence interval {CI}, 0.24-0.53]), whereas patients positive for hepatitis B surface antigen (HBsAg) were more likely to have spontaneously cleared HCV than were those negative for HBsAg (43% vs. 21%; aOR, 2.91 [95% CI, 1.94-4.38]). Of patients with HCV viremia, 786 (53%) carried HCV genotype 1, and 53 (4%), 440 (29%), and 217 (15%) carried HCV genotype 2, 3, and 4, respectively. A greater HCV RNA level was associated with a greater chance of being infected with HCV genotype 1 (aOR, 1.60 per 1 log higher [95% CI, 1.36-1.88]). CONCLUSIONS: More than three-quarters of the HIV- and HCV Ab-positive patients in EuroSIDA showed active HCV replication. Viremia was more frequent in IDUs and, conversely, was less common in HBsAg-positive patients. Of the patients with HCV viremia analyzed, 53% were found to carry HCV genotype 1, and this genotype was associated with greater serum HCV RNA levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. METHODS: Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. RESULTS: For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. CONCLUSIONS: Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the impact of noninvasive ventilation (NIV) algorithms available on intensive care unit ventilators on the incidence of patient-ventilator asynchrony in patients receiving NIV for acute respiratory failure. Prospective multicenter randomized cross-over study. Intensive care units in three university hospitals. Patients consecutively admitted to the ICU and treated by NIV with an ICU ventilator were included. Airway pressure, flow and surface diaphragmatic electromyography were recorded continuously during two 30-min periods, with the NIV (NIV+) or without the NIV algorithm (NIV0). Asynchrony events, the asynchrony index (AI) and a specific asynchrony index influenced by leaks (AIleaks) were determined from tracing analysis. Sixty-five patients were included. With and without the NIV algorithm, respectively, auto-triggering was present in 14 (22%) and 10 (15%) patients, ineffective breaths in 15 (23%) and 5 (8%) (p = 0.004), late cycling in 11 (17%) and 5 (8%) (p = 0.003), premature cycling in 22 (34%) and 21 (32%), and double triggering in 3 (5%) and 6 (9%). The mean number of asynchronies influenced by leaks was significantly reduced by the NIV algorithm (p < 0.05). A significant correlation was found between the magnitude of leaks and AIleaks when the NIV algorithm was not activated (p = 0.03). The global AI remained unchanged, mainly because on some ventilators with the NIV algorithm premature cycling occurs. In acute respiratory failure, NIV algorithms provided by ICU ventilators can reduce the incidence of asynchronies because of leaks, thus confirming bench test results, but some of these algorithms can generate premature cycling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Slight differences in physiological responses and nitric oxide (NO) have been reported at rest between hypobaric hypoxia (HH) and normobaric hypoxia (NH) during short exposure.Our study reports NO and oxidative stress at rest and physiological responses during moderate exercise in HH versus NH. METHODS: Ten subjects were randomly exposed for 24 h to HH (3000 m; FIO2, 20.9%; BP, 530 ± 6 mm Hg) or to NH (FIO2, 14.7%; BP, 720 ± 1 mm Hg). Before and every 8 h during the hypoxic exposures, pulse oxygen saturation (SpO2), HR, and gas exchanges were measured during a 6-min submaximal cycling exercise. At rest, the partial pressure of exhaled NO, blood nitrate and nitrite (NOx), plasma levels of oxidative stress, and pH levels were additionally measured. RESULTS: During exercise, minute ventilation was lower in HH compared with NH (-13% after 8 h, P < 0.05). End-tidal CO2 pressure was lower (P < 0.01) than PRE both in HH and NH but decreased less in HH than that in NH (-25% vs -37%, P < 0.05).At rest, exhaled NO and NOx decreased in HH (-46% and -36% after 24 h, respectively, P < 0.05) whereas stable in NH. By contrast, oxidative stress was higher in HH than that in NH after 24 h (P < 0.05). The plasma pH level was stable in HH but increased in NH (P < 0.01). When compared with prenormoxic values, SpO2, HR, oxygen consumption, breathing frequency, and end-tidal O2 pressure showed similar changes in HH and NH. CONCLUSION: Lower ventilatory responses to a similar hypoxic stimulus during rest and exercise in HH versus NH were sustained for 24 h and associated with lower plasma pH level, exaggerated oxidative stress, and impaired NO bioavailability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To document the prevalence of asynchrony events during noninvasive ventilation in pressure support in infants and in children and to compare the results with neurally adjusted ventilatory assist. DESIGN: Prospective randomized cross-over study in children undergoing noninvasive ventilation. SETTING: The study was performed in a PICU. PATIENTS: From 4 weeks to 5 years. INTERVENTIONS: Two consecutive ventilation periods (pressure support and neurally adjusted ventilatory assist) were applied in random order. During pressure support (PS), three levels of expiratory trigger (ETS) setting were compared: initial ETS (PSinit), and ETS value decreased and increased by 15%. Of the three sessions, the period allowing for the lowest number of asynchrony events was defined as PSbest. Neurally adjusted ventilator assist level was adjusted to match the maximum airway pressure during PSinit. Positive end-expiratory pressure was the same during pressure support and neurally adjusted ventilator assist. Asynchrony events, trigger delay, and cycling-off delay were quantified for each period. RESULTS: Six infants and children were studied. Trigger delay was lower with neurally adjusted ventilator assist versus PSinit and PSbest (61 ms [56-79] vs 149 ms [134-180] and 146 ms [101-162]; p = 0.001 and 0.02, respectively). Inspiratory time in excess showed a trend to be shorter during pressure support versus neurally adjusted ventilator assist. Main asynchrony events during PSinit were autotriggering (4.8/min [1.7-12]), ineffective efforts (9.9/min [1.7-18]), and premature cycling (6.3/min [3.2-18.7]). Premature cycling (3.4/min [1.1-7.7]) was less frequent during PSbest versus PSinit (p = 0.059). The asynchrony index was significantly lower during PSbest versus PSinit (40% [28-65] vs 65.5% [42-76], p < 0.001). With neurally adjusted ventilator assist, all types of asynchronies except double triggering were reduced. The asynchrony index was lower with neurally adjusted ventilator assist (2.3% [0.7-5] vs PSinit and PSbest, p < 0.05 for both comparisons). CONCLUSION: Asynchrony events are frequent during noninvasive ventilation with pressure support in infants and in children despite adjusting the cycling-off criterion. Compared with pressure support, neurally adjusted ventilator assist allows improving patient-ventilator synchrony by reducing trigger delay and the number of asynchrony events. Further studies should determine the clinical impact of these findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumant mon travail de thèse, l'article qui suit décrit un nouveau modèle animal servant à étudier l'impact combiné d'une ventilation mécanique (VM), d'une oxygénothérapie et d'une inflammation sur des poumons immatures. Cette étude permet, pour la première fois, de mesurer l'expression de gènes à distance d'une VM pour en analyser la cinétique. La VM représente un traitement intégral dans la prise en charge de prématurés. Sauvant des vies, elle est cependant non-physiologique et décrite comme nocive à court et à long terme, empêchant le bon développement pulmonaire. Nombreuses études se sont intéressées à l'impact immédiat de la VM sur les poumons, mais il n'existe à ce jour aucun modèle de rongeur pour en analyser les effets tardifs. Par analogie avec la clinique, nous avons créé un modèle avec un animal dont le stade développemental pulmonaire est comparable aux prématurés humains et consistant en une oxygénothérapie, une VM modérée avec intubation non chirurgicale, similaire à la pratique quotidienne, et un contexte inflammatoire mimant celui de chorioamnionite dans lequel bien des prématurés naissent. Nous avons ensuite réalisé une extubation pour permettre une période de rétablissement, puis fait des analyses et sur le plan structurel par histologie conventionnelle et en 3D, et sur le plan biologique, par analyse de l'expression de gènes et de protéines. Ce travail a permis de valider ce nouveau modèle comme outil de recherche pour réaliser des mesures à distance d'une VM chez des rats nouveau-nés. Comparant ces mesures à celles prises à la fin de la VM, nous observons: une augmentation initiale et transitoire des médiateurs impliqués dans la cascade inflammatoire dont le corrélat histologique est une maladie inflammatoire pulmonaire et, tardivement, une altération plus développementale de la structure pulmonaire avec diminution de l'alvéolarisation. Ceci pourrait être en partie dû à une expression asynchrone de gènes décrits comme importants pour la formation des alvéoles (matrix metalloproteinase 9, elastine). Offrant une nouvelle approche pour la recherche pulmonaire chez les rongeurs, ce modèle servira comme futur outil pour approfondir nos connaissances de la physiopathologie conduisant aux altérations structurelles retrouvées dans les poumons d'anciens prématurés soumis à une VM (dysplasie broncho-pulmonaire), pour tester l'influence de certains traitements (p.ex. surfactant) et pour étudier les effets de la VM en l'appliquant à des modèles transgéniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The combination of pain, ipsilateral oculosympathetic defect (ptosis and miosis), and ipsilateral trigeminal dysfunction constitutes Raeder's syndrome. We describe a patient with an acute presentation of Raeder's syndrome due to spontaneous internal carotid artery dissection. True trigeminal dysfunction due to carotid dissection is rare, and the potential mechanisms for its involvement are reviewed in this paper. Finally, we remind clinicians to consider dissection in the differential diagnosis of Raeder's syndrome because of its potential for ischemic cerebral neurologic sequelae and suggest early cranial and neck imaging in the evaluation of such patients.