996 resultados para spectral quality radiation


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background and purpose: Trans-Tasman Radiation Oncology Group 96.05 is a prospective randomized controlled trial comparing a single 8 Gy with 20 Gy in five fractions of radiotherapy (RT) for neuropathic pain due to bone metastases. This paper summarizes the quality assurance (QA) activities for the first 234 patients (accrual target 270). Materials and methods: Independent audits to assess compliance with eligibility/exclusion criteria and appropriateness of treatment of the index site were conducted after each cohort of approximately 45 consecutive patients. Reported serious adverse events (SAEs) in the form of cord/cauda equina compression or pathological fracture developing at the index site were investigated and presented in batches to the Independent Data Monitoring Committee. Finally, source data verification of the RT prescription page and treatment records was undertaken for each of the first 234 patients to assess compliance with the protocol. Results: Only one patient was found conclusively not to have genuine neuropathic pain, and there were no detected 'geographical misses' with RT fields. The overall rate of detected infringements for other eligibility criteria over five audits (225 patients) was 8% with a dramatic improvement after the first audit. There has at no stage been a statistically significant difference in SAEs by randomization arm. There was a 22% rate of RT protocol variations involving ten of the 14 contributing centres, although the rate of major dose violations (more than +/- 10% from protocol dose) was only 6% with no statistically significant difference by randomization arm (P = 0.44). Conclusions: QA auditing is an essential but time-consuming component of RT trials, including those assessing palliative endpoints. Our experience confirms that all aspects should commence soon after study activation. Crown Copyright (C) 2003 Published by Elsevier Science Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The spectral properties of long-period gratings (LPGs) fabricated in photonic crystal fibers using femtosecond laser pulses by the point-by-point technique, without oil-immersion of the fiber, are investigated in detail. Postfabrication spectral monitoring at room temperature showed significant long-term instability of the gratings and stable spectra only after 600 h. The stabilized spectral properties of the gratings improved with increasing annealing temperature. The observed changes in resonant wavelength, optical strength, and grating birefringence were correlated to the laser inscription energy and were further used to study the mechanism of femtosecond inscription. Furthermore, the femtosecond-laser inscribed LPGs were compared to electric-arc fabricated LPGs. Comparison of experimental results with theoretical models of LPGs and laser propagation during inscription indicate that the major processes responsible for the index change are permanent compaction and thermally induced strain, the latter can be significantly changed through annealing. © 2011 Optical Society of America.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The spectral distribution of solar radiation was studied under different sky conditions during a 15- month period in Miami, Florida (USA), and over a latitudinal gradient at solar maximum. Spectroradiometric scans were characterized for total irradiance (300- 3000 nm) and the relative energetic and photon contributions of the following wavelength regions: UV-B (300-320nm); UV-A (320-400nm); B (400-500rim); PAR (400-700 nm); R (600-700 nm); and FR (728- 732 rim). Notable results include: (i) significantly higher UV-A energy fluxes than currently in use for laboratory experiments involving the biological effects of this bandwidth (values ranged from 33.6 to 55.4 W/m 2 in Miami over the year); (ii) marked diurnal shifts in B:R and R:FR, with elevated R:FR values in early morning: (iii) a strong correlation between R: FR and atmospheric water content; and (iv) unusually high PAR values under direct sunlight with cloudy skies (2484 ~tmot/2 per s).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

X-ray computed tomography (CT) is a non-invasive medical imaging technique that generates cross-sectional images by acquiring attenuation-based projection measurements at multiple angles. Since its first introduction in the 1970s, substantial technical improvements have led to the expanding use of CT in clinical examinations. CT has become an indispensable imaging modality for the diagnosis of a wide array of diseases in both pediatric and adult populations [1, 2]. Currently, approximately 272 million CT examinations are performed annually worldwide, with nearly 85 million of these in the United States alone [3]. Although this trend has decelerated in recent years, CT usage is still expected to increase mainly due to advanced technologies such as multi-energy [4], photon counting [5], and cone-beam CT [6].

Despite the significant clinical benefits, concerns have been raised regarding the population-based radiation dose associated with CT examinations [7]. From 1980 to 2006, the effective dose from medical diagnostic procedures rose six-fold, with CT contributing to almost half of the total dose from medical exposure [8]. For each patient, the risk associated with a single CT examination is likely to be minimal. However, the relatively large population-based radiation level has led to enormous efforts among the community to manage and optimize the CT dose.

As promoted by the international campaigns Image Gently and Image Wisely, exposure to CT radiation should be appropriate and safe [9, 10]. It is thus a responsibility to optimize the amount of radiation dose for CT examinations. The key for dose optimization is to determine the minimum amount of radiation dose that achieves the targeted image quality [11]. Based on such principle, dose optimization would significantly benefit from effective metrics to characterize radiation dose and image quality for a CT exam. Moreover, if accurate predictions of the radiation dose and image quality were possible before the initiation of the exam, it would be feasible to personalize it by adjusting the scanning parameters to achieve a desired level of image quality. The purpose of this thesis is to design and validate models to quantify patient-specific radiation dose prospectively and task-based image quality. The dual aim of the study is to implement the theoretical models into clinical practice by developing an organ-based dose monitoring system and an image-based noise addition software for protocol optimization.

More specifically, Chapter 3 aims to develop an organ dose-prediction method for CT examinations of the body under constant tube current condition. The study effectively modeled the anatomical diversity and complexity using a large number of patient models with representative age, size, and gender distribution. The dependence of organ dose coefficients on patient size and scanner models was further evaluated. Distinct from prior work, these studies use the largest number of patient models to date with representative age, weight percentile, and body mass index (BMI) range.

With effective quantification of organ dose under constant tube current condition, Chapter 4 aims to extend the organ dose prediction system to tube current modulated (TCM) CT examinations. The prediction, applied to chest and abdominopelvic exams, was achieved by combining a convolution-based estimation technique that quantifies the radiation field, a TCM scheme that emulates modulation profiles from major CT vendors, and a library of computational phantoms with representative sizes, ages, and genders. The prospective quantification model is validated by comparing the predicted organ dose with the dose estimated based on Monte Carlo simulations with TCM function explicitly modeled.

Chapter 5 aims to implement the organ dose-estimation framework in clinical practice to develop an organ dose-monitoring program based on a commercial software (Dose Watch, GE Healthcare, Waukesha, WI). In the first phase of the study we focused on body CT examinations, and so the patient’s major body landmark information was extracted from the patient scout image in order to match clinical patients against a computational phantom in the library. The organ dose coefficients were estimated based on CT protocol and patient size as reported in Chapter 3. The exam CTDIvol, DLP, and TCM profiles were extracted and used to quantify the radiation field using the convolution technique proposed in Chapter 4.

With effective methods to predict and monitor organ dose, Chapters 6 aims to develop and validate improved measurement techniques for image quality assessment. Chapter 6 outlines the method that was developed to assess and predict quantum noise in clinical body CT images. Compared with previous phantom-based studies, this study accurately assessed the quantum noise in clinical images and further validated the correspondence between phantom-based measurements and the expected clinical image quality as a function of patient size and scanner attributes.

Chapter 7 aims to develop a practical strategy to generate hybrid CT images and assess the impact of dose reduction on diagnostic confidence for the diagnosis of acute pancreatitis. The general strategy is (1) to simulate synthetic CT images at multiple reduced-dose levels from clinical datasets using an image-based noise addition technique; (2) to develop quantitative and observer-based methods to validate the realism of simulated low-dose images; (3) to perform multi-reader observer studies on the low-dose image series to assess the impact of dose reduction on the diagnostic confidence for multiple diagnostic tasks; and (4) to determine the dose operating point for clinical CT examinations based on the minimum diagnostic performance to achieve protocol optimization.

Chapter 8 concludes the thesis with a summary of accomplished work and a discussion about future research.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper describes measurements from shortwave radiation radiosonde ascents done at the Atlantische Expedition 1969. Using the results from a total of 67 ascents mean components of the shortwave radiation budget of the atmospheric layer between the ocean surface and the top of the ascent are discussed. The influence of clouds on the radiation balance is shown by dividing the ascents in classes of cloudiness and cloud altitude. Thereby the albedo of the ocean surface is increasing with increasing amount of cloudiness. Similar the albedo of the troposphere increases involving an increased heating rate of the atmospheric layer.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Atmospheric scattering plays a crucial rule in degrading the performance of electro optical imaging systems operating in the visible and infra-red spectral bands, and hence limits the quality of the acquired images, either through reduction of contrast or increase of image blur. The exact nature of light scattering by atmospheric media is highly complex and depends on the types, orientations, sizes and distributions of particles constituting these media, as well as wavelengths, polarization states and directions of the propagating radiation. Here we follow the common approach for solving imaging and propagation problems by treating the propagating light through atmospheric media as composed of two main components: a direct (unscattered), and a scattered component. In this work we developed a detailed model of the effects of absorption and scattering by haze and fog atmospheric aerosols on the optical radiation propagating from the object plane to an imaging system, based on the classical theory of EM scattering. This detailed model is then used to compute the average point spread function (PSF) of an imaging system which properly accounts for the effects of the diffraction, scattering, and the appropriate optical power level of both the direct and the scattered radiation arriving at the pupil of the imaging system. Also, the calculated PSF, properly weighted for the energy contributions of the direct and scattered components is used, in combination with a radiometric model, to estimate the average number of the direct and scattered photons detected at the sensor plane, which are then used to calculate the image spectrum signal to- noise ratio (SNR) in the visible near infra-red (NIR) and mid infra-red (MIR) spectral wavelength bands. Reconstruction of images degraded by atmospheric scattering and measurement noise is then performed, up to the limit imposed by the noise effective cutoff spatial frequency of the image spectrum SNR. Key results of this research are as follows: A mathematical model based on Mie scattering theory for how scattering from aerosols affects the overall point spread function (PSF) of an imaging system was developed, coded in MATLAB, and demonstrated. This model along with radiometric theory was used to predict the limiting resolution of an imaging system as a function of the optics, scattering environment, and measurement noise. Finally, image reconstruction algorithms were developed and demonstrated which mitigate the effects of scattering-induced blurring to within the limits imposed by noise.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Radiation dosimetry is crucial in many fields, where the exposure of ionizing radiation must be precisely controlled to avoid health and environmental safety issues. Radiotherapy and radioprotection are two examples in which fast and reliable detectors are needed. Compact and large area wearable detectors are being developed to address real-life radiation dosimetry applications, their ideal properties include flexibility, lightness, and low-cost. This thesis contributed to the development of Radiation sensitive OXide Field Effect Transistors (ROXFETs), which are detectors able to provide fast and real-time radiation read out. ROXFETs are based on thin film transistors fabricated with high-mobility amorphous oxide semiconductor, making them compatible with large area, flexible, and low cost production over plastic substrates. The gate dielectric material has high dielectric constant and high atomic number, which results in high performances and high radiation sensitivity, respectively. The aim of this work was to establish a stable and reliable fabrication process for ROXFETs made with atomic layer deposited gate dielectric. A study on the effect of gate dielectric materials was performed, focusing the attention on the properties of the dielectric-semiconductor interface. Single and multi layer dielectric structures were compared during this work. Furthermore, the effect of annealing temperature was studied. The device performances were tested to understand the underlying physical processes. In this way, it was possible to determine a reliable fabrication procedure and an optimal structure for ROXFETs. An outstanding sensitivity of (65±3)V/Gy was measured in detectors with a bi-layer Ta₂O₅-Al₂O₃ gate dielectric with low temperature annealing performed at 180°C.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective and Background Data: Common side effects of radiotherapy (RT) to the head and neck include oral mucositis, xerostomia, and severe pain. The aim of this study is to report improvement in the quality of life of an oncological patient by laser phototherapy (LPT). Clinical Case and Laser Phototherapy Protocol: The patient, a 15-year-old girl diagnosed with mucoepidermoid carcinoma, underwent surgical excision of a tumor of the left palatomaxilla. After that, she was subjected to 35 sessions of RT (2 Gy/d). Clinical examination revealed the spread of severe ulcerations to the jugal mucosa, gums, lips, hard palate, and tongue (WHO mucositis score 3). She had difficulty in moving her tongue and she was unable to eat any solid food. Oral hygiene orientation and LPT were performed throughout all RT sessions. A continuous diode laser, 660 nm, 40 mW, 6 J/cm(2), 0.24 J per point in contact mode, with spot size of 0.04 cm(2) was used in the entire oral cavity. A high-power diode laser at 1 W, 10 sec per cm of mucositis, approximately 10 J/cm(2), was used in defocused mode only on ulcerative lesions. After the first laser irradiation session, decreases in pain and xerostomia were reported; however, a more significant improvement was seen after five sessions. At that point although the mucositis score was still 2, the patient reported that she was free of pain, and consequently a palatine plate could be made to rehabilitate the entire surgical area. Seventeen laser irradiation sessions were necessary to eliminate all oral mucositis lesions. Conclusion: Normal oral function and consequent improvements in the quality of life of this oncologic patient were observed with LPT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work describes the seasonal and diurnal variations of downward longwave atmospheric irradiance (LW) at the surface in Sao Paulo, Brazil, using 5-min-averaged values of LW, air temperature, relative humidity, and solar radiation observed continuously and simultaneously from 1997 to 2006 on a micrometeorological platform, located at the top of a 4-story building. An objective procedure, including 2-step filtering and dome emission effect correction, was used to evaluate the quality of the 9-yr-long LW dataset. The comparison between LW values observed and yielded by the Surface Radiation Budget project shows spatial and temporal agreement, indicating that monthly and annual average values of LW observed in one point of Sao Paulo can be used as representative of the entire metropolitan region of Sao Paulo. The maximum monthly averaged value of the LW is observed during summer (389 +/- 14 W m(-2): January), and the minimum is observed during winter (332 +/- 12 W m(-2); July). The effective emissivity follows the LW and shows a maximum in summer (0.907 +/- 0.032; January) and a minimum in winter (0.818 +/- 0.029; June). The mean cloud effect, identified objectively by comparing the monthly averaged values of the LW during clear-sky days and all-sky conditions, intensified the monthly average LW by about 32.0 +/- 3.5 W m(-2) and the atmospheric effective emissivity by about 0.088 +/- 0.024. In August, the driest month of the year in Sao Paulo, the diurnal evolution of the LW shows a minimum (325 +/- 11 W m(-2)) at 0900 LT and a maximum (345 12 W m-2) at 1800 LT, which lags behind (by 4 h) the maximum diurnal variation of the screen temperature. The diurnal evolution of effective emissivity shows a minimum (0.781 +/- 0.027) during daytime and a maximum (0.842 +/- 0.030) during nighttime. The diurnal evolution of all-sky condition and clear-sky day differences in the effective emissivity remain relatively constant (7% +/- 1%), indicating that clouds do not change the emissivity diurnal pattern. The relationship between effective emissivity and screen air temperature and between effective emissivity and water vapor is complex. During the night, when the planetary boundary layer is shallower, the effective emissivity can be estimated by screen parameters. During the day, the relationship between effective emissivity and screen parameters varies from place to place and depends on the planetary boundary layer process. Because the empirical expressions do not contain enough information about the diurnal variation of the vertical stratification of air temperature and moisture in Sao Paulo, they are likely to fail in reproducing the diurnal variation of the surface emissivity. The most accurate way to estimate the LW for clear-sky conditions in Sao Paulo is to use an expression derived from a purely empirical approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Landscape unit discrimination for pedological surveys by orbital spectral response. The objective of tins study was compare two soil survey methods. The first was performed by methods traditionally used to distinguish landscape units and soil class discrimination. The second was based on soil class distinction through orbital spectral response. In order to establish soil characteristics and their classification, soil samples were collected at two depths in a grid system, with a distance of 500 meters between points. With these samples, physical and chemical analyses were carried out. In the sampling points, the apparent reflectance of the soil, front the orbital image, was determined and, through cluster analysis landscape units were established. In order to evaluate the resemblance reliability between the landscape units established in each method, the Kappa index was used, the value set for the confusion matrix was 0.43, indicating high quality in the comparison, showing that the non-conventional method was as close as the one carried out by photointerpretation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Frozen samples of mechanically deboned chicken meat (MDCM) with skin were irradiated with gamma radiation doses of 0.0 kGy (control) and 3 kGy at 2 different radiation dose rates: 0.32 kGy/h (3 kGy) and 4.04 kGy/h (3 kGy). Batches of irradiated and control samples were evaluated during 11 d of refrigerated (2 +/- 1 degrees C) storage for the following parameters: total psychrotrophic bacteria count, thiobarbituric acid reactive substances (TBARS), evaluation of objective color (L*, a*, and b*) and a sensory evaluation (irradiated odor, oxidized odor, pink and brown colors). No statistical difference (P > 0.05) was found amongst the TBARS values obtained for the MDCM samples irradiated with dose rates of 0.32 and 4.04 kGy/h. There was a significant increase (P < 0.05) in the psychrotrophic bacterial count as from the 7th day of refrigerated storage, for the MDCM samples irradiated at the dose rate of 4.04 kGy/h. With respect to the attribute of oxidized odor, the samples irradiated with a dose rate of 0.32 kGy/h showed a stronger intensity and were significantly different (P < 0.05) from the sample irradiated with a dose rate of 4.04 kGy/h on days 0 and 2 of refrigerated storage. Irradiation with a dose rate of 4.04 kGy/h (3 kGy) was shown to be the best condition for the processing of MDCM according to the evaluation of all the variables, under the conditions of this study. Practical Application The results obtained for the application of different dose rates of ionizing radiation to mechanically deboned chicken meat will provide the food industry with information concerning the definition of the best processing conditions to maximize the sensory and food quality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hydrodynamic studies were conducted in a semi-cylindrical spouted bed column of diameter 150 mm, height 1000 mm, conical base included angle of 60 degrees and inlet orifice diameter 25 mm. Pressure transducers at several axial positions were used to obtain pressure fluctuation time series with 1.2 and 2.4 mm glass beads at U/U-ms from 0.3 to 1.6, and static bed depths from 150 to 600 mm. The conditions covered several flow regimes (fixed bed, incipient spouting, stable spouting, pulsating spouting, slugging, bubble spouting and fluidization). Images of the system dynamics were also acquired through the transparent walls with a digital camera. The data were analyzed via statistical, mutual information theory, spectral and Hurst`s Rescaled Range methods to assess the potential of these methods to characterize the spouting quality. The results indicate that these methods have potential for monitoring spouted bed operation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The compound eyes of mantis shrimps (stomatopod crustaceans) include an unparalleled diversity of visual pigments and spectral receptor classes in retinas of each species. We compared the visual pigment and spectral receptor classes of 12 species of gonodactyloid stomatopods from a variety of photo environments, from intertidal to deep water ( > 50 m), to learn how spectral tuning in the different photoreceptor types is modified within different photic environments. Results show that receptors of the peripheral photoreceptors, those outside the midband which are responsible for standard visual tasks such as spatial vision and motion detection, reveal the well-known pattern of decreasing lambda(max) with increasing depth. Receptors of midband rows 5 and 6, which are specialized for polarization vision, are similar in all species, having visual lambda(max)-values near 500 nm, independent of depth. Finally the spectral receptors of midband rows 1 to 4 are tuned for maximum coverage of the spectrum of irradiance available in the habitat of each species. The quality of the visual worlds experienced by each species we studied must vary considerably, but all appear to exploit the full capabilities offered by their complex visual systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Concerns exist regarding the effect of radiation dose from paediatric pelvic CT scans and the potential later risk of radiation-induced neoplasm and teratogenic outcomes in these patients. Objective: To assess the diagnostic quality of CT images of the paediatric pelvis using either reduced mAs or increased pitch compared with standard settings. Materials and methods: A prospective study of pelvic CT scans of 105 paediatric patients was performed using one of three protocols: (1) 31 at a standard protocol of 200 mA with rotation time of 0.75 s at 120 kVp and a pitch factor approximating 1.4; (2) 31 at increased pitch factor approaching 2 and 200 mA; and (3) 43 at a reduced setting of 100 mA and a pitch factor of 1.4. All other settings remained the same in all three groups. Image quality was assessed by radiologists blinded to the protocol used in each scan. Results: No significant difference was found between the quality of images acquired at standard settings and those acquired at half the standard mAs. The use of increased pitch factor resulted in a higher proportion of poor images. Conclusions: Images acquired at 120 kVp using 75 mAs are equivalent in diagnostic quality to those acquired at 150 mAs. Reduced settings can provide useful imaging of the paediatric pelvis and should be considered as a standard protocol in these situations.