854 resultados para software performance evaluation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

IEEE 802.11p is the new standard for intervehicular communications (IVC) using the 5.9 GHz frequency band; it is planned to be widely deployed to enable cooperative systems. 802.11p uses and performance have been studied theoretically and in simulations over the past years. Unfortunately, many of these results have not been confirmed by on-tracks experimentation. In this paper, we describe field trials of 802.11p technology with our test vehicles; metrics such as maximum range, latency and frame loss are examined. Then, we propose a detailed modelisation of 802.11p that can be used to accurately simulate its performance within Cooperative Systems (CS) applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we describe the benefits of a performance-based approach to modeling biological systems for use in robotics. Specifically, we describe the RatSLAM system, a computational model of the navigation processes thought to drive navigation in a part of the rodent brain called the hippocampus. Unlike typical computational modeling approaches, which focus on biological fidelity, RatSLAM’s development cycle has been driven primarily by performance evaluation on robots navigating in a wide variety of challenging, real world environments. We briefly describe three seminal results, two in robotics and one in biology. In addition, we present current research on brain-inspired learning algorithms with the aim of enabling a robot to autonomously learn how best to use its sensor suite to navigate, without requiring any specific knowledge of the robot, sensor types or environment characteristics. Our aim is to drive discussion on the merits of practical, performance-focused implementations of biological models in robotics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This research aimed to develop a framework for performance evaluation of public hospitals in Vietnam that is culturally, socially, and politically appropriate. The research included both qualitative and quantitative methods and identified and validated novel instruments to measure patient satisfaction and job satisfaction of hospital staff and to determine a set of hospital indicators that reflect the quality of hospital performance. New models for understanding the determinants of patient and staff satisfaction were developed along with a new performance indicator framework for hospital performance. These instruments will now be applied to the evaluation of hospital services in Khanh Hoa Province, permitting longer term evaluation of their effectiveness in changing system wide performance and satisfaction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Knowledge management (KM) strategy is the planned or actual coordination of a firm's major goals and learning in time; this coordination continually co-aligns the firm's knowledge-based resources with the environment. Based on the organic perspective of strategy, a KM performance evaluation approach should be able to 1) review the knowledge governance mechanisms and learning routines that underpin the KM strategy, as well as the performance outcomes driven by the strategy, and 2) predict the evolution of performance drivers and outcomes into the future to facilitate strategic planning. This study combined a survey study and a system dynamics (SD) simulation to demonstrate the transformation from a mechanistic to an organic perspective on KM strategy and performance evaluation. The survey study was conducted based on a sample of 143 construction contractors and used structural equation modeling (SEM) techniques to develop a KM performance index for reviewing the key elements that underpin KM strategy. The SD simulation predicted the development of KM strategy configurations and the evolution of KM performance over time. The organic KM performance evaluation approach demonstrated by this study has significant potential to improve the alignment of KM strategy within an increasingly dynamic business environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The design, implementation and evaluation are described of a dual-microcomputer system based on the concept of shared memory. Shared memory is useful for passing large blocks of data and it also provides a means to hold and work with shared data. In addition to the shared memory, a separate bus between the I/O ports of the microcomputers is provided. This bus is utilized for interprocessor synchronization. Software routines helpful in applying the dual-microcomputer system to realistic problems are presented. Performance evaluation of the system is carried out using benchmarks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For Variable Stiffness (VS) composites with steered curvilinear tow paths, the fiber orientation angle varies continuously throughout the laminate, and is not required to be straight, parallel and uniform within each ply as in conventional composite laminates. Hence, the thermal properties (conduction), as well as the structural stiffness and strength, vary as functions of location in the laminate, and the associated composite structure is often called a “variable stiffness” composite structure. The steered fibers lead not only to the alteration of mechanical load paths, but also to the alteration of thermal paths that may
result in favorable temperature distributions within the laminate and improve the laminate performance. Evaluation of VS laminate performance under thermal loading is the focus of this chapter. Thermal performance evaluations require experimental and numerical analysis of VS laminates under different processing and loading conditions. One of the advantages of using composite materials in many applications is the tailoring capability of the laminate,
not only during the design phase but also for manufacturing. Heat transfer through variable conduction and chemical reaction (degree of cure) occurring during manufacturing (curing) plays an important role in the final thermal and mechanical performance, and shape of composite structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Optimizing and editing enterprise software systems, after the implementation process has started, is widely recognized to be an expensive process. This has led to increasing emphasis on locating mistakes within software systems at the design stage, to help minimize development costs. There is increasing interest in the field of architecture evaluation techniques that can identify problems at the design stage, either within complete, or partially complete architectures. Most current techniques rely on manual review-based evaluation methods that require advanced skills from architects and evaluators. We are currently considering what a formal Architecture Description Language (ADL) can contribute to the process of architecture evaluation and validation. Our investigation is considering the inter-relationships between the activities performed during the architecture evaluation process, the characteristics an ADL should possess to support these activities, and the tools needed to provide convenient access to, and presentation of architectural information.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Photovoltaic Thermal/Hybrid collectors are an emerging technology that combines PV and solar thermal collectors by producing heat and electricity simultaneously. In this paper, the electrical performance evaluation of a low concentrating PVT collector was done through two testing parts: power comparison and performance ratio testing. For the performance ratio testing, it is required to identify and measure the factors affecting the performance ratio on a low concentrating PVT collector. Factors such as PV cell configuration, collector acceptance angle, flow rate, tracking the sun, temperature dependence and diffuse to irradiance ratio. Solarus low concentrating PVT collector V12 was tested at Dalarna University in Sweden using the electrical equipment at the solar laboratory. The PV testing has showed differences between the two receivers. Back2 was producing 1.8 energy output more than Back1 throughout the day. Front1 and Front2 were almost the same output performance. Performance tests showed that the cell configuration for Receiver2 with cells grouping (6- 32-32-6) has proved to have a better performance ratio when to it comes to minimizing the shading effect leading to more output power throughout the day because of lowering the mismatch losses. Different factors were measured and presented in this thesis in chapter 5. With the current design, it has been obtained a peak power at STC of 107W per receiver. The solar cells have an electrical efficiency of approximately 19% while the maximum measured electrical efficiency for the collector was approximately 18 % per active cell area, in addition to a temperature coefficient of -0.53%/ ˚C. Finally a recommendation was done to help Solarus AB to know how much the electrical performance is affected during variable ambient condition and be able to use the results for analyzing and introducing new modification if needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The case study presents findings from a program of pre- and post-evaluations of buildings sponsored by the NSW government. The program aims to demonstrate leadership in the delivery of government accommodation and to provide feedback into the building design and management process.

The results from a combined evaluation of an ABGR 4.5 star government building using the KODO probe© occupant surveys and measures of environmental conditions, carried out by the Mobile Architecture and Built Environment Laboratory (MABEL) at Deakin University are summarised. In particular the paper will present the benefits of innovative performance evaluation of property for commercial benefit using the KODO productivity topographic maps©.

These maps isolate where facility solutions are needed as opposed to tenant/occupant solutions in order to optimise building and business outcomes with minimal capital investment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article investigates the context dependency of comfort and energy performance in mixed-mode offices in the climate of Athens, Greece. It is based on a parametric study using the simulation software EnergyPlus. Context refers to different building design priorities on the real estate market (prestige, low cost and green), occupant behaviour scenarios (ideal and worst case) and cooling strategies (fixed and adaptive set points). Results are evaluated according to energy consumption and related greenhouse gas emissions, daylight autonomy, view and percentage of working time when heating and cooling are operating. The results indicate that a holistic approach to comfort and energy performance evaluation focused on the specific context of a building and its occupants is necessary to develop appropriate optimization strategies. In early design stages, such specific information is not yet available and ideal/worst-case scenarios can indicate the magnitude of influence of occupants compared to building design.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This experiment aimed at evaluating the effects of the interactions between aflatoxin (500 or 250 ppb) and ochratoxin (500 or 250 ppb), and the possible benefits of adding yeast cell wall to prevent the effects of these mycotoxins in broiler chickens. Relative organ weight gain and live performance were evaluated at 21 and 42 days of age. Results indicated that at the levels of mycotoxins included in the experimental diets, ochratoxin reduced feed intake and body weight gain, and aflatoxin only affect feed intake of 21-day-old birds. No interaction was observed between aflatoxin and ochratoxin at the levels used in experimental study. Yeast cell wall did not significantly reduced the deleterious effects of ochratoxins. No significant differences were observed in relative organ weight gain. Yeast cell wall improved feed conversion ratio when birds were fed either contaminated or non-contaminated feeds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main objective is to create a software, using C++ language, for reading and exhibiting in a graphic an Electrocardiogram (ECG) wave. The data is recorded as a FM modulated signal and compressed using Adaptive Differential Pulse Code Modulation (ADPCM). The signal have this characteristics because it was acquired using an experimental equipment, this equipment is the result of research made by the professor who supervised this work. FM demodulation techniques in discrete time, discrete filters and digital signal processing are some of the topics that can be found in this essay. Some concepts about the human heart and about ECG waves are also briefly introduced. These concepts are necessary for understanding the final evaluation of the software performance. The development is partly made using MATLAB. Most of the functions that are used on the software are first tested and designed in MATLAB environment. In the end, an evaluation is done comparing the results that are expected with the ones that MATLAB presents and the ones that the developed software presents

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The web services (WS) technology provides a comprehensive solution for representing, discovering, and invoking services in a wide variety of environments, including Service Oriented Architectures (SOA) and grid computing systems. At the core of WS technology lie a number of XML-based standards, such as the Simple Object Access Protocol (SOAP), that have successfully ensured WS extensibility, transparency, and interoperability. Nonetheless, there is an increasing demand to enhance WS performance, which is severely impaired by XML's verbosity. SOAP communications produce considerable network traffic, making them unfit for distributed, loosely coupled, and heterogeneous computing environments such as the open Internet. Also, they introduce higher latency and processing delays than other technologies, like Java RMI and CORBA. WS research has recently focused on SOAP performance enhancement. Many approaches build on the observation that SOAP message exchange usually involves highly similar messages (those created by the same implementation usually have the same structure, and those sent from a server to multiple clients tend to show similarities in structure and content). Similarity evaluation and differential encoding have thus emerged as SOAP performance enhancement techniques. The main idea is to identify the common parts of SOAP messages, to be processed only once, avoiding a large amount of overhead. Other approaches investigate nontraditional processor architectures, including micro-and macrolevel parallel processing solutions, so as to further increase the processing rates of SOAP/XML software toolkits. This survey paper provides a concise, yet comprehensive review of the research efforts aimed at SOAP performance enhancement. A unified view of the problem is provided, covering almost every phase of SOAP processing, ranging over message parsing, serialization, deserialization, compression, multicasting, security evaluation, and data/instruction-level processing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, thermal, exergetic analysis and performance evaluation of seawater and fresh wet cooling tower and the effect of parameters on its performance is investigated. With using of energy and mass balance equations, experimental results, a mathematical model and EES code developed. Due to lack of fresh water, seawater cooling is interesting choice for future of cooling, so the effect of seawater in the range of 1gr/kg to 60gr/kg for salinity on the performance characteristics like air efficiency, water efficiency, output water temperature of cooling tower, flow of the exergy, and the exergy efficiency with comparison with fresh water examined. Decreasing of air efficiency about 3%, increasing of water efficiency about 1.5% are some of these effects. Moreover with formation of fouling the performance of cooling tower decreased about 15% which this phenomena and its effects like increase in output water temperature and tower excess volume has been showed and also accommodate with others work. Also optimization for minimizing cost, maximizing air efficiency, and minimizing exergy destruction has been done, results showed that optimization on minimizing the exergy destruction has been satisfy both minimization of the cost and the maximization of the air efficiency, although it will not necessarily permanent for all inputs and optimizations. Validation of this work is done by comparing computational results and experimental data which showed that the model have a good accuracy.