983 resultados para prosthesis implant


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Capsular fibrosis is a severe complication after breast implantation with an uncertain etiology. Microbial colonization of the prosthesis is hypothesized as a possible reason for the low-grade infection and subsequent capsular fibrosis. Current diagnostic tests consist of intraoperative swabs and tissue biopsies. Sonication of removed implants may improve the diagnosis of implant infection by detachment of biofilms from the implant surface. METHODS: Breast implants removed from patients with Baker grades 3 and 4 capsular contracture were analyzed by sonication, and the resulting sonication fluid was quantitatively cultured. RESULTS: This study investigated 22 breast implants (6 implants with Baker 3 and 16 implants with Baker 4 capsular fibrosis) from 13 patients. The mean age of the patients was 49 years (range, 31-76 years). The mean implant indwelling time was 10.4 years (range, 3 months to 30 years). Of the 22 implants, 12 were used for breast reconstruction and 10 for aesthetic procedures. The implants were located subglandularly (n = 12), submuscularly (n = 6), and subcutaneously (n = 4). Coagulase-negative staphylococci, Propionibacterium acnes, or both were detected in the sonication fluid cultures of nine implants (41%), eight of which grew significant numbers of microorganisms (>100 colonies/ml of sonication fluid). CONCLUSIONS: Sonication detected bacteria in 41% of removed breast implants. The identified bacteria belonged to normal skin flora. Further investigation is needed to determine any causal relation between biofilms and capsular fibrosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infections associated with implants are increasingly important in modem medicine. Biofilms are the cause that these infections are more difficult to diagnose and to cure. Particularly low-grade infections are difficult to distinguish from aseptic failure, because they often present with early loosening and persisting pain. For an accurate diagnosis, clinical signs and symptoms, laboratory markers of infection, microbiology, histology and imaging examinations are needed. The treatment goal is eradication of infection and an optimal functional result. Successful treatment requires adequate surgical procedure combined with long-term antimicrobial therapy, ideally with an agent acting on biofilms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Extraskeletal myxoid chondrosarcoma (EMC) is a rare soft tissue tumour with a high risk for local recurrence and metastases. While this entity is resistant to radio- or chemo-therapy, wide resection remains the treatment of choice. Case report: A 60 year old man presented to our service with a large mass in his right thigh, slowly evolving over the past 7 years. His main complaint was the volume of his thigh. Imaging showed a 23x13x14 cm tumour in the quadriceps, eroding the cortical bone and with potential contamination of the knee joint. The risk of a pathological fracture was estimated considerable. A CT-guided core-needle biopsy revealed a FNCLCC grade 2 EMC. A thoraco-abdominal CT scan showed multiple pulmonary metastases. Due to the palliative situation with a very slow disease progression, a wide extraarticular resection of the distal femur and reconstruction with a megaprosthesis were performed. Extensive skin necrosis necessitated three revision procedures for débridement and confection of a pediculated lateral gastrocnemius muscle flap. No complementary treatment was possible for the pulmonary metastases. At 18 months follow-up, he walked without crutches, was able to do his activities of daily living. He was painfree and highly satisfied with the result. During the follow-up, slow progression of the pulmonary metastases was noted, which remained asymptomatic. Conclusion: Extraskeletal myxoid chondrosarcoma is a rare soft tissue tumour, and wide excision remains the treatment of choice. Whenever possible, limb salvage should be proposed to preserve function and quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The aim of this study was to evaluate the mid-term biocompatibility of a new x-shaped implant made of zirconium in an animal model of glaucoma surgery. METHODS: Preoperatively, ultrasound biomicroscopy (UBM), intraocular pressure (IOP) and outflow facility (OF) data were acquired. Upon surgery, one eye was chosen randomly to receive an implant, while the other received none. Ten rabbits went through a 1-, 2-, 3-, 4- and 6-month follow-up. IOP was measured regularly, UBM performed at 1, 3 and 6 months after surgery. At the end of the follow-up, OF was again measured. Histology sections were analyzed. RESULTS: For both groups IOP control was satisfactory, while OF initially increased at month 1 to resume preoperative values thereafter. Eyes with implants had larger filtration blebs which decreased faster than in eyes without the implant. Drainage vessel density, inflammatory cell number and fibrosis were higher in tissues near the implant. CONCLUSIONS: The zirconium implant initially promoted the positive effects of the surgery (IOP control, OF increase). Nevertheless, after several months, foreign body reactions and fibrosis had occurred on some implants that restrained the early benefit of such a procedure. Modifications of the zirconium implant geometry could enhance the overall success rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The risk that hip preserving surgery may negatively influence the performance and outcome of subsequent total hip replacement (THR) remains a concern. The aim of this study was to identify any negative impact of previous hip arthroscopy on THR. METHODS: Out of 1271 consecutive patients who underwent primary THR between 2005 and 2009, 18 had previously undergone ipsilateral hip arthroscopy. This study group (STG) was compared with two control groups (CG, same approach, identical implants; MCG, paired group matched for age, BMI and Charnley categories). Operative time, blood loss, evidence of heterotopic bone and implant loosening at follow-up were compared between the STG and the MCG. Follow-up WOMAC were compared between the three groups. RESULTS: Blood loss was not found to be significantly different between the STG and MCG. The operative time was significantly less (p < 0.001) in the STG. There was no significant difference in follow-up WOMAC between the groups. No implant related complications were noted in follow-up radiographs. Two minor complications were documented for the STG and three for the MCG. CONCLUSION: We have found no evidence that previous hip arthroscopy negatively influences the performance or short-term clinical outcome of THR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: We report on the in vivo testing of a novel noninvasively adjustable glaucoma drainage device (AGDD), which features an adjustable outflow resistance, and assess the safety and efficiency of this implant. METHODS: Under general anesthesia, the AGDD was implanted on seven white New Zealand rabbits for a duration of 4 months under a scleral flap in a way analogous to the Ex-PRESS device and set in an operationally closed position. The IOP was measured on a regular basis on the operated and control eyes using a rebound tonometer. Once a month the AGDD was adjusted noninvasively from its fully closed to its fully open position and the resulting pressure drop was measured. The contralateral eye was not operated and served as control. After euthanization, the eyes were collected for histology evaluation. RESULTS: The mean preoperative IOP was 11.1 ± 2.4 mm Hg. The IOP was significantly lower for the operated eye (6.8 ± 2 mm Hg) compared to the nonoperated eye (13.1 ± 1.6 mm Hg) during the first 8 days after surgery. When opening the AGDD from its fully closed to fully open position, the IOP dropped significantly from 11.2 ± 2.9 to 4.8 ± 0.9 mm Hg (P < 0.05). CONCLUSIONS: Implanting the AGDD is a safe and uncomplicated surgical procedure. The fluidic resistance was noninvasively adjustable during the postoperative period with the AGDD between its fully closed and fully open positions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: We investigate a new heat delivery technique for the local treatment of solid tumors. The technique involves injecting a formulation that solidifies to form an implant in situ. This implant entraps superparamagnetic iron oxide nanoparticles (SPIONs) embedded in silica microbeads for magnetically induced moderate hyperthermia. Particle entrapment prevents phagocytosis and distant migration of SPIONs. The implant can be repeatedly heated by magnetic induction. Methods: We evaluated heating and treatment efficacies by means of thermometry and survival studies in nude mice carrying subcutaneous human colocarcinomas. At day 1, we injected the formulation into the tumor. At day 2, a single 20-min hyperthermia treatment was delivered by 141-kHz magnetic induction using field strengths of 9 to 12 mT under thermometry. Results: SPIONs embedded in silica microbeads were effectively confined within the implant at the injection site. Heat-induced necro-apoptosis was assessed by histology on day 3. On average, 12 mT resulted in tumor temperature of 47.8 degrees C, and over 70% tumor necrosis that correlated to the heat dose (AUC = 282 degrees C.min). In contrast, a 9-mT field strength induced tumoral temperature of 40 degrees C (AUC = 131 degrees C.min) without morphologically identifiable necrosis. Survival after treatment with 10.5 or 12 mT fields was significantly improved compared to non-implanted and implanted controls. Median survival times were 27 and 37 days versus 12 and 21 days respectively. Conclusion: Five of eleven mice (45%) of the 12 mT group survived one year without any tumor recurrence, holding promise for tumor therapy using magnetically induced moderate hyperthermia through injectable implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study verifies whether cochlear implants helps deaf adults to maintain or develop their professional occupations. Sixty-seven patients received a questionnaire concerning their professional activities before and after implantation. At the time of implantation 34 were professionally active. After the implantation 29 remained active, 4 of them reporting positive developments in their careers. Five patients became inactive. The previously inactive patients remained inactive. There was no difference in auditory performances between professionally active or inactive patients. Cochlear implants enable most implanted adults to maintain and even progress in their professions. However, deafness still represents an obstacle to social integration as inactive patients who searched for a job were rejected after the job interviews.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: All patients with extensive resection of the anterolateral chest wall and the sternum followed by reconstruction with methylmethacrylate substitutes were assessed prospectively 6 months after the operation to delineate chest wall integrity with pulmonary function and cine-magnetic resonance imaging. METHODS: Twenty-six patients underwent chest wall reconstruction by use of methylmethacrylate between 1994 and 1998 due to primary tumors in 35%, metastases in 27%, T3 lung cancer in 19%, and debridement for radionecrosis and osteomyelitis in 19% of patients. Three to eight ribs were resected and additional sternum resection was performed in 39% of patients. RESULTS: There was no 30-day mortality. All patients were extubated after the operation without need for reintubation. Prosthesis dislocation occurred in 1 patient and infection in 2 patients during follow-up. Nineteen patients (73%) suffered no restrictions of daily activities. Clinical examination revealed normal shoulder girdle function in 77% of patients. There was no significant difference between preoperative and postoperative FEV1 (forced expiratory volume in 1 second) measurements in patients with lobectomy or wedge resections. Cinemagnetic resonance imaging revealed concordant chest wall movements during respiration in 92% of patients without paradoxical movements or implant dislocations being observed. CONCLUSIONS: Large defects of the anterolateral chest wall and sternum can be reconstructed efficiently with methylmethacrylate substitutes with minimal morbidity and excellent cosmetic and functional outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The role of Propionibacterium acnes in acne and in a wide range of inflammatory diseases is well established. However, P. acnes is also responsible for infections involving implants. Prolonged aerobic and anaerobic agar cultures for 14 days and broth cultures increase the detection rate. In this paper, we review the pathogenic role of P. acnes in implant-associated infections such as prosthetic joints, cardiac devices, breast implants, intraocular lenses, neurosurgical devices, and spine implants. The management of severe infections caused by P. acnes involves a combination of antimicrobial and surgical treatment (often removal of the device). Intravenous penicillin G and ceftriaxone are the first choice for serious infections, with vancomycin and daptomycin as alternatives, and amoxicillin, rifampicin, clindamycin, tetracycline, and levofloxacin for oral treatment. Sonication of explanted prosthetic material improves the diagnosis of implant-associated infections. Molecular methods may further increase the sensitivity of P. acnes detection. Coating of implants with antimicrobial substances could avoid or limit colonization of the surface and thereby reduce the risk of biofilm formation during severe infections. Our understanding of the role of P. acnes in human diseases will likely continue to increase as new associations and pathogenic mechanisms are discovered.