987 resultados para preoperative
Resumo:
A transitory increase in blood pressure (BP) is observed following upper airway surgery for obstructive sleep apnea syndrome but the mechanisms implicated are not yet well understood. The objective of the present study was to evaluate changes in BP and heart rate (HR) and putative factors after uvulopalatopharyngoplasty and septoplasty in normotensive snorers. Patients (N = 10) were instrumented for 24-h ambulatory BP monitoring, nocturnal respiratory monitoring and urinary catecholamine level evaluation one day before surgery and on the day of surgery. The influence of postsurgery pain was prevented by analgesic therapy as confirmed using a visual analog scale of pain. Compared with preoperative values, there was a significant (P < 0.05) increase in nighttime but not daytime systolic BP (119 ± 5 vs 107 ± 3 mmHg), diastolic BP (72 ± 4 vs 67 ± 2 mmHg), HR (67 ± 4 vs 57 ± 2 bpm), respiratory disturbance index (RDI) characterized by apnea-hypopnea (30 ± 10 vs 13 ± 4 events/h of sleep) and norepinephrine levels (22.0 ± 4.7 vs 11.0 ± 1.3 µg l-1 12 h-1) after surgery. A positive correlation was found between individual variations of BP and individual variations of RDI (r = 0.81, P < 0.01) but not between BP or RDI and catecholamines. The visual analog scale of pain showed similar stress levels on the day before and after surgery (6.0 ± 0.8 vs 5.0 ± 0.9 cm, respectively). These data strongly suggest that the cardiovascular changes observed in patients who underwent uvulopalatopharyngoplasty and septoplasty were due to the increased postoperative RDI.
Resumo:
A fibrose é um acúmulo demasiado de matriz extracelular, resultante de um desequilíbrio entre a síntese e a degradação dos seus componentes. É associada às alterações metabólicas do tecido adiposo, contudo sua ocorrência nos diferentes depósitos e repercussões clínicas ainda não são totalmente compreendidas. O objetivo deste estudo foi analisar a fibrose no tecido adiposo em relação à presença de obesidade, localização do depósito [tecido adiposo subcutâneo abdominal (TASA) e visceral (TAV)] e sua associação a variáveis clínicas. Amostras de gordura do TASA e TAV foram obtidas de 21 mulheres submetidas à cirurgia bariátrica (IMC>40Kg/m2) e 25 amostras de TASA das submetidas à abdominoplastia (IMC<30Kg/m2). As amostras foram processadas para histologia convencional. O corante picrosirius foi utilizado para avaliação das fibras colágenas totais. As imagens obtidas foram analisadas no ADIPOSOFT®. O percentual de fibrose no TASA e no TAV foi analisado com testes estatísticos não paramétricos, adotando-se um valor de p<0,05. A fibrose no TASA foi maior em mulheres com obesidade (p<0.0006). A fibrose entre os depósitos de TASA e de TAV foi observada apenas em mulheres pardas e negras com obesidade (p<0,012). A fibrose no TASA não foi correlacionada com as variáveis clínicas nas mulheres sem obesidade. No entanto, nas submetidas à cirurgia bariátrica, foram observadas correlações da fibrose no TASA com Índice de Massa Corpórea (IMC), hemoglobina glicada (A1c), LDL e triglicerídeos; e no TAV com porcentagem de perda gordura pré-operatório, % de perda de gordura total, % de massa magra pré, Taxa Metabólica Basal (TBM) e Gasto Energético Basal (GEB). Os parâmetros metabólicos e de perfil antropométrico antes da cirurgia bariátrica foram associados à fibrose no TASA, enquanto os parâmetros após a cirurgia foram associados à fibrose no TAV.
Resumo:
Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.
Resumo:
Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.
Resumo:
Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.
Resumo:
Background: Precise needle puncture of renal calyces is a challenging and essential step for successful percutaneous nephrolithotomy. This work tests and evaluates, through a clinical trial, a real-time navigation system to plan and guide percutaneous kidney puncture. Methods: A novel system, entitled i3DPuncture, was developed to aid surgeons in establishing the desired puncture site and the best virtual puncture trajectory, by gathering and processing data from a tracked needle with optical passive markers. In order to navigate and superimpose the needle to a preoperative volume, the patient, 3D image data and tracker system were previously registered intraoperatively using seven points that were strategically chosen based on rigid bone structures and nearby kidney area. In addition, relevant anatomical structures for surgical navigation were automatically segmented using a multi-organ segmentation algorithm that clusters volumes based on statistical properties and minimum description length criterion. For each cluster, a rendering transfer function enhanced the visualization of different organs and surrounding tissues. Results: One puncture attempt was sufficient to achieve a successful kidney puncture. The puncture took 265 seconds, and 32 seconds were necessary to plan the puncture trajectory. The virtual puncture path was followed correctively until the needle tip reached the desired kidney calyceal. Conclusions: This new solution provided spatial information regarding the needle inside the body and the possibility to visualize surrounding organs. It may offer a promising and innovative solution for percutaneous punctures.
Resumo:
The implementation of the presumptive donor law in Brazil is expected to increase the availability of organs for transplantation. As medical management of end-stage organ dysfunction continues to improve, increasing numbers of potential transplant recipients will be available to meet this supply. There is mounting evidence that supports the involvement of skilled psychiatric practitioners in the selection of transplant candidates. Data supporting the influence of psychosocial factors on compliance and therefore medical outcomes continues to grow. The literature review allows delineating the components and rationale for comprehensive psychosocial evaluations as a component of preoperative transplantation evaluation.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Ramo de especialização: Ultrassonografia Cardiovascular
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Ramo de especialização: Ultrassonografia Cardiovascular
Resumo:
Information obtained from the routine application of hydatid immunodiagnostic techniques in different clinical situations over a seven-year period is presented. The Immunoelectrophoresis test was used until it was replaced by the simpler, more sensitive and equally specific arc 5 double diffusion (DD5) test. Examination of sera from 1,888 patients with signs and/or symptoms compatible with hydatid disease revealed that the presurgical confirmation of Echinococcus granulosus infection is only obtained by detection of anti-antigen 5 antibodies. The latter were not found in 1,539 presumptive hydatidosis patients whose definitive diagnoses corresponded to other disease conditions. However, false positive latex agglutination test results were obtained in two cases. In all patients whose preoperative serum showed three or more uncharacteristic bands in the absence of anti-antigen 5 antibodies, hydatid cysts were found sur gically. DD5 testing of a fluid sample collected by puncture established its hydatid etiology. Post-operative monitoring of hydatidosis patients demonstrated that persistence of DD5-positivity two years after surgery established the presence of other cysts. Further evidence was obtained in patients with hydatid cysts in intrathoracic, abdominal or other locations associating cyst membrane integrity, antigen release and immunodiagnostic test positivity.
Resumo:
BACKGROUND: Surgery for congenital heart disease (CHD) has changed considerably during the last three decades. The results of primary repair have steadily improved, to allow treating almost all patients within the pediatric age; nonetheless an increasing population of adult patients requires surgical treatment. The objective of this study is to present the early surgical results of patients who require surgery for CHD in the adult population within a multicentered European study population. METHODS: Data relative to the hospital course of 2,012 adult patients (age > or = 18 years) who required surgical treatment for CHD from January 1, 1997 through December 31, 2004 were reviewed. Nineteen cardiothoracic centers from 13 European countries contributed to the data collection. RESULTS: Mean age at surgery was 34.4 +/- 14.53 years. Most of the operations were corrective procedures (1,509 patients, 75%), followed by reoperations (464 patients, 23.1%) and palliative procedures (39 patients, 1.9%). Six hundred forty-nine patients (32.2%) required surgical closure of an isolated ostium secundum atrial septal defect. Overall hospital mortality was 2%. Preoperative cyanosis, arrhythmias, and NYHA class III-IV, proved significant risk factors for hospital mortality. Follow-up data were available in 1,342 of 1,972 patients (68%) who were discharged home. Late deaths occurred in 6 patients (0.5%). Overall survival probability was 97% at 60 months, which is higher for corrective procedures (98.2%) if compared with reoperations (94.1%) and palliations (86.1%). CONCLUSIONS: Surgical treatment of CHD in adult patients, in specialized cardiac units, proved quite safe, beneficial, and low-risk.
Resumo:
Periferal vascular disease usually results from a systemic entity in which atherothrombosis develops in different vascular territories, having common risk factors. It is hence usual to find coexistent, often subclinical, coronary artery disease, which is responsible for most of perioperatory morbidity and mortality in patients submitted to vascular surgery. An adequate preoperatory risk stratification must be accomplished, having in mind the clinical manifestations, risk factors, comorbidities, functional capacity and global left ventricular systolic function of the patient. He should be included in one of three different subgroups: low, high or intermediate risk, which might reinforce the need for further testing, most often aiming at the detection of coronary artery disease and foresee the short, medium and long term outcome. This strategy is very important and it is in part due to it and to better medical/surgical and anesthetic care that the surgical results have markedly improved in recent years. In this paper a state of the art is done of the guidelines to follow and the results of several studies performed on this subject. The role of methods to detect coronary ischemia is remarked, using either nuclear or echocardiographic techniques for this purpose.
Resumo:
OBJECTIVES: This study analyzes the results of the arterial switch operation for transposition of the great arteries in member institutions of the European Congenital Heart Surgeons Association. METHODS: The records of 613 patients who underwent primary arterial switch operations in each of 19 participating institutions in the period from January 1998 through December 2000 were reviewed retrospectively. RESULTS: A ventricular septal defect was present in 186 (30%) patients. Coronary anatomy was type A in 69% of the patients, and aortic arch pathology was present in 20% of patients with ventricular septal defect. Rashkind septostomy was performed in 75% of the patients, and 69% received prostaglandin. There were 37 hospital deaths (operative mortality, 6%), 13 (3%) for patients with an intact ventricular septum and 24 (13%) for those with a ventricular septal defect (P < .001). In 36% delayed sternal closure was performed, 8% required peritoneal dialysis, and 2% required mechanical circulatory support. Median ventilation time was 58 hours, and intensive care and hospital stay were 6 and 14 days, respectively. Although of various preoperative risk factors the presence of a ventricular septal defect, arch pathology, and coronary anomalies were univariate predictors of operative mortality, only the presence of a ventricular septal defect approached statistical significance (P = .06) on multivariable analysis. Of various operative parameters, aortic crossclamp time and delayed sternal closure were also univariate predictors; however, only the latter was an independent statistically significant predictor of death. CONCLUSIONS: Results of the procedure in European centers are compatible with those in the literature. The presence of a ventricular septal defect is the clinically most important preoperative risk factor for operative death, approaching statistical significance on multivariable analysis.