991 resultados para paper chromatography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho foi realizado no âmbito do projecto Lab on Paper, desenvolvido no Centro de Investigação de Materiais (CENIMAT) da Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa (FCT - UNL)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis reports the work performed in the optimization of deposition parameters of Multi – Walled Carbon Nanotubes (MWCNT) targeting the development of a Field Effect Transistors (FET) on paper substrates. The CNTs were dispersed in a water solution with sodium dodecyl sulphate (SDS) through ultrasonication, ultrasonic bath and a centrifugation to remove the supernatant and have a homogeneous solution. Several deposition tests were performed using different types of CNTs, dis-persants, papers substrates and deposition techniques, such as spray coating and inkjet printing. The characterization of CNTs was made by Scanning Electron Microscopy (SEM) and Hall Effect. The most suitable CNT coatings able to be used as semiconductor in FETs were deposited by spray coat-ing on a paper substrate with hydrophilic nanoporous surface (FS2) at 100 ºC, 4 bar, 10 cm height, 5 second of deposition time and 90 seconds of drying between steps (4 layers of CNTs were deposited). Planar electrolyte gated FETs were produced with these layers using gold-nickel gate, source and drain electrodes. Despite the small current modulation (Ion/Ioff ratio of 1.8) one of these devices have p-type conduction with a field effect mobility of 1.07 cm2/V.s.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Human serofrequency of antibodies against Taenia solium antigens was determined and risk factors for cysticercosis transmission were identified. METHODS: Individuals (n=878) from periurban and rural locations of Lages, SC, were interviewed to gather demographic, sanitary and health information. Interviews and blood sample collections by finger prick on Whatman filter paper were performed from August 2004 to May 2005. Observation determined that 850 samples were suitable for analysis and were tested by ELISA using vesicular fluid of Taenia crassiceps heterologous antigen. To ensure the reliability of the results, 77 samples of the dried blood were matched with sera. The reactive samples were submitted to a serum confirmatory immunoblot (IB) test using purified Taenia crassiceps glycoproteins. RESULTS: The ELISA results for the dried blood and serum samples were statistically consistent. ELISA was positive in 186 (21.9%) out of 850 individuals. A group of 213 individuals were asked to collect vein blood for IB (186 with positive result in ELISA and 27 with inappropriate whole blood samples) and 130 attended the request. The IB was positive in 29 (3.4%) out of 850 individuals. A significant correlation (p = 0.0364) was determined among individuals who tested positive in the IB assay who practiced both pig rearing and kitchen gardening. CONCLUSIONS: ELISA with dried blood eluted from filter paper was suitable for cysticercosis population surveys. In Lages, human infection was associated with pig rearing and kitchen gardening. The prevalence index was compatible with other Latin American endemic areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis is one of the first reports of digital microfluidics on paper and the first in which the chip’s circuit was screen printed unto the paper. The use of the screen printing technique, being a low cost and fast method for electrodes deposition, makes the all chip processing much more aligned with the low cost choice of paper as a substrate. Functioning chips were developed that were capable of working at as low as 50 V, performing all the digital microfluidics operations: movement, dispensing, merging and splitting of the droplets. Silver ink electrodes were screen printed unto paper substrates, covered by Parylene-C (through vapor deposition) as dielectric and Teflon AF 1600 (through spin coating) as hydrophobic layer. The morphology of different paper substrates, silver inks (with different annealing conditions) and Parylene deposition conditions were studied by optical microscopy, AFM, SEM and 3D profilometry. Resolution tests for the printing process and electrical characterization of the silver electrodes were also made. As a showcase of the applications potential of these chips as a biosensing device, a colorimetric peroxidase detection test was successfully done on chip, using 200 nL to 350 nL droplets dispensed from 1 μL drops.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main results presented in this PhD Dissertation have been published in interna-tional journals included in the Science Citation Index (SCI)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Online data collection is becoming increasingly common and has some advantages compared to traditional paper-and-pencil formats, such as reducing loss of data, increasing participants' privacy, and decreasing the effect of social desirability. However, the validity and reliability of this administration format must be established before results can be considered acceptable. The aim of this study was to evaluate the validity, reliability, and equivalence of paper-and-pencil and online versions of the Weight Concerns Scale (WCS) when applied to Brazilian university students. A crossover design was used, and the Portuguese version of the WCS (in both paper-and-pencil and online formats) was completed by 100 college students. The results indicated adequate fit in both formats. The simultaneous fit of data for both groups was excellent, with strong invariance between models. Adequate convergent validity, internal consistency, and mean score equivalence of the WCS in both formats were observed. Thus, the WCS presented adequate reliability and validity in both administration formats, with equivalence/stability between answers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Peak and trough serum concentrations of vancomycin were determined in term newborn infants with confirmed or suspected Staphylococcus sp sepsis by high performance liquid chromatography and flourescence polarization immunoassay. OBJECTIVE: To statistically compare the results of the high performance liquid chromatography and flourescence polarization immunoassay techniques for measuring serum vancomycin concentrations. METHODS: Eighteen peak and 20 trough serum samples were assayed for vancomycin concentrations using high performance liquid chromatography and flourescence polarization immunoassay from October 1995 to October 1997. RESULTS: The linear correlation coefficients for high performance liquid chromatography and flourescence polarization immunoassay were 0.27 (peak, P = 0.110) and 0.26 (trough, P = 0.1045) respectively, which were not statistically significant. CONCLUSION: There was wide variation in serum vancomycin concentrations determined by high performance liquid chromatography as compared with those determined by flourescence polarization immunoassay. There was no recognizable pattern in the variability; in an apparently random fashion, the high performance liquid chromatography measurement was sometimes substantially higher than the flourescence polarization immunoassay measurement, and at other times it was substantially lower.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work will discuss the use of different paper membranes as both the substrate and dielectric for field-effect memory transistors. Three different nanofibrillated cellulose membranes (NFC) were used as the dielectric layer of the memory transistors (NFC), one with no additives, one with an added polymer PAE and one with added HCl. Gallium indium zinc oxide (GIZO) was used as the device’s semiconductor and gallium aluminium zinc oxide (GAZO) was used as the gate electrode. Fourier transform infrared spectroscopy (FTIR) was used to access the water content of the paper membranes before and after vacuum. It was found that the devices recovered their water too quickly for a difference to be noticeable in FTIR. The transistor’s electrical performance tests yielded a maximum ION/IOFF ratio of around 3,52x105 and a maximum subthreshold swing of 0,804 V/decade. The retention time of the dielectric charge that grants the transistor its memory capabilities was accessed by the measurement of the drain current periodically during 144 days. During this period the mean drain current did not lower, leaving the retention time of the device indeterminate. These results were compared with similar devices revealing these devices to be at the top tier of the state-of-the-art.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An ion chromatography procedure, employing an IonPac AC15 concentrator column was used to investigate on line preconcentration for the simultaneous determination of inorganic anions and organic acids in river water. Twelve organic acids and nine inorganic anions were separated without any interference from other compounds and carry-over problems between samples. The injection loop was replaced by a Dionex AC15 concentrator column. The proposed procedure employed an auto-sampler that injected 1.5 ml of sample into a KOH mobile phase, generated by an Eluent Generator, at 1.5 mL min-1, which carried the sample to the chromatographic columns (one guard column, model AG-15, and one analytical column, model AS15, with 250 x 4mm i.d.). The gradient elution concentrations consisted of a 10.0 mmol l-1 KOH solution from 0 to 6.5 min, gradually increased to 45.0 mmol l-1 KOH at 21 min., and immediatelly returned and maintained at the initial concentrations until 24 min. of total run. The compounds were eluted and transported to an electro-conductivity detection cell that was attached to an electrochemical detector. The advantage of using concentrator column was the capability of performing routine simultaneous determinations for ions from 0.01 to 1.0 mg l-1 organic acids (acetate, propionic acid, formic acid, butyric acid, glycolic acid, pyruvate, tartaric acid, phthalic acid, methanesulfonic acid, valeric acid, maleic acid, oxalic acid, chlorate and citric acid) and 0.01 to 5.0 mg l-1 inorganic anions (fluoride, chloride, nitrite, nitrate, bromide, sulfate and phosphate), without extensive sample pretreatment and with an analysis time of only 24 minutes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several suction–water-content (s-w) calibrations for the filter paper method (FPM) used for soil-suction measurement have been published. Most of the calibrations involve a bilinear function (i.e., two different equations) with an inflection point occurring at 60 kPapaper Whatman No. 42 (W42) is presented and discussed. The approach is applied herein to data obtained from three establish bilinear calibrations (six equations) for W42 filter paper to determine the two fitting parameters of the continuous function. An experimental evaluation of the new calibration show that the suctions estimated by the contact FPM test using the proposed function compare well with suctions measured by other laboratory techniques for two different soils for the suction range of 50 kPa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

სტატია მომზადდა ევროაკადემიის მეორე გლობალური კონფერენციისთვის „ევროპა შიგნით და გარეთ: მრავალრიცხოვანი დამკვირვებლების თვალით დანახული ევროპა და ევროპელები"