991 resultados para optical heterodyne detection


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigate the use of an arrayed waveguide grating (AWG) to interrogate both fibre Bragg grating (FBG) and interferometric sensors. A broadband light source is used to illuminate both the FBG and interferometric sensors. Reflected spectral information is directed to an AWG with integral photodetectors providing 40 electrical outputs. To interrogate interferometric sensors we investigated the dual wavelength technique to measure the distance of a Fabry-Perot cavity, which produced a maximum unambiguous range of 1440μm with an active sensor. Three methods are described to interrogate FBG sensors. The first technique makes use of the reflected light intensity in an AWG channel passband from a narrow bandwidth grating, giving a usable range of 500με and a dynamic strain resolution of 96nε/√Hz at 30Hz. The second approach utilises wide gratings larger than the channel spacing of the AWG; by monitoring the intensity present in corresponding AWG channels an improved range of 1890με was achieved. The third method improves the dynamic range by utilising a heterodyne approach based on interferometric wavelength shift detection providing a dynamic strain resolution of 17nε/√Hz at 30Hz.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper develops a theoretical analysis of the tradeoff between carrier suppression and nonlinearities induced by optical IQ modulators in direct-detection subcarrier multiplexing systems. The tradeoff is obtained by examining the influence of the bias conditions of the modulator on the transmitted single side band signal. The frequency components in the electric field and the associated photocurrent at the output of the IQ modulator are derived mathematically. For any frequency plan, the optimum bias point can be identified by calculating the sensitivity gain for every subchannel. A setup composed of subcarriers located at multiples of the data rate ensures that the effects of intermodulation distortion are studied in the most suitable conditions. Experimental tests with up to five QPSK electrical subchannels are performed to verify the mathematical model and validate the predicted gains in sensitivity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a comparative study of the influence of dispersion induced phase noise for n-level PSK systems. From the analysis, we conclude that the phase noise influence for classical homodyne/heterodyne PSK systems is entirely determined by the modulation complexity (expressed in terms of constellation diagram) and the analogue demodulation format. On the other hand, the use of digital signal processing (DSP) in homodyne/intradyne systems renders a fiber length dependence originating from the generation of equalization enhanced phase noise. For future high capacity systems, high constellations must be used in order to lower the symbol rate to practically manageable speeds, and this fact puts severe requirements to the signal and local oscillator (LO) linewidths. Our results for the bit-error-rate (BER) floor caused by the phase noise influence in the case of QPSK, 16PSK and 64PSK systems outline tolerance limitations for the LO performance: 5 MHz linewidth (at 3-dB level) for 100 Gbit/s QPSK; 1 MHz for 400 Gbit/s QPSK; 0.1 MHz for 400 Gbit/s 16PSK and 1 Tbit/s 64PSK systems. This defines design constrains for the phase noise impact in distributed-feed-back (DFB) or distributed-Bragg-reflector (DBR) semiconductor lasers, that would allow moving the system capacity from 100 Gbit/s system capacity to 400 Gbit/s in 3 years (1 Tbit/s in 5 years). It is imperative at the same time to increase the analogue to digital conversion (ADC) speed such that the single quadrature symbol rate goes from today's 25 GS/s to 100 GS/s (using two samples per symbol). © 2014 by Walter de Gruyter Berlin/Boston.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The optical redox ratio as a measure of cellular metabolism is determined by an altered ratio between endogenous fluorophores NADH and flavin adenine dinucleotide (FAD). Although reported for other cancer sites, differences in optical redox ratio between cancerous and normal urothelial cells have not previously been reported. Here, we report a method for the detection of cellular metabolic states using flow cytometry based on autofluorescence, and a statistically significant increase in the redox ratio of bladder cancer cells compared to healthy controls. Urinary bladder cancer and normal healthy urothelial cell lines were cultured and redox overview was assessed using flow cytometry. Further localisation of fluorescence in the same cells was carried out using confocal microscopy. Multiple experiments show correlation between cell type and redox ratio, clearly differentiating between healthy cells and cancer cells. Based on our preliminary results, therefore, we believe that this data contributes to current understanding of bladder tissue fluorescence and can inform the design of endoscopic probes. This approach also has significant potential as a diagnostic tool for discrimination of cancer cells among shed urothelial cells in voided urine, and could lay the groundwork for an automated system for population screening for bladder cancer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We implement an optical biosensor using long-period fibre grating immobilised with probe DNA. It has been used to detect hybridisation of target DNA, showing a high sensitivity and reusability function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We review recent advances in all-optical OFDM technologies and discuss the performance of a field trial of a 2 Tbit/s Coherent WDM over 124 km with distributed Raman amplification. The results indicate that careful optimisation of the Raman pumps is essential. We also consider how all-optical OFDM systems perform favourably against energy consumption when compared with alternative coherent detection schemes. We argue that, in an energy constrained high-capacity transmission system, direct detected all-optical OFDM with `ideal' Raman amplification is an attractive candidate for metro area datacentre interconnects with ~100 km fibre spans, with an overall energy requirement at least three times lower than coherent detection techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A dual-parameter optical sensor has been realized by UV-writing a long-period and a Bragg grating structure in D-fiber. The hybrid configuration permits the detection of the temperature from the latter and measuring the external refractive index from the former responses, respectively. The employment of the D-fiber allows as effective modification and enhancement of the device sensitivity by cladding etching. The grating sensor has been used to measure the concentrations of aqueous sugar solutions, demonstrating the potential capability to detect concentration changes as small as 0.01%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Using an optical biosensor based on a dual-peak long-period fiber grating, we have demonstrated the detection of interactions between biomolecules in real time. Silanization of the grating surface was successfully realized for the covalent immobilization of probe DNA, which was subsequently hybridized with the complementary target DNA sequence. It is interesting to note that the DNA biosensor was reusable after being stripped off the hybridized target DNA from the grating surface, demonstrating a function of multiple usability. © 2007 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a method to measure in real-time the instantaneous generation spectrum of fiber lasers over consecutive cavity round-trips. © 2015 OSA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Opto-Acoustic Endoscopy (OAE) requires sensors with a high sensitivity and small physical dimensions in order to facilitate integration into an endoscope of less than 1mm in diameter. We present fibre Bragg grating (FBG) and Fabry- Perot intrinsic fibre sensors for ultrasound detection. We present a structure profile characterisation setup to analyse tune the fibre sensors in preparation for ultrasonic detection. We evaluate the suitability of the different structures and grating parameters for ultrasonic sensing. By analysing the prepared gratings, we enable the optimisation of the profile and a simplification of the detection regime for an optimal interferometric OAE configuration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To determine the best photographic surrogate markers for detecting sight-threatening macular oedema (MO) in people with diabetes attending UK national screening programmes. Design: A multicentre, prospective, observational cohort study of 3170 patients with photographic signs of diabetic retinopathy visible within the macular region [exudates within two disc diameters, microaneurysms/dot haemorrhages (M/DHs) and blot haemorrhages (BHs)] who were recruited from seven study centres. Setting: All patients were recruited and imaged at one of seven study centres in Aberdeen, Birmingham, Dundee, Dunfermline, Edinburgh, Liverpool and Oxford. Participants: Subjects with features of diabetic retinopathy visible within the macular region attending one of seven diabetic retinal screening programmes. Interventions: Alternative referral criteria for suspected MO based on photographic surrogate markers; an optical coherence tomographic examination in addition to the standard digital retinal photograph. Main outcome measures: (1) To determine the best method to detect sight-threatening MO in people with diabetes using photographic surrogate markers. (2) Sensitivity and specificity estimates to assess the costs and consequences of using alternative strategies. (3) Modelled long-term costs and quality-adjusted life-years (QALYs). Results: Prevalence of MO was strongly related to the presence of lesions and was roughly five times higher in subjects with exudates or BHs or more than two M/DHs within one disc diameter. Having worse visual acuity was associated with about a fivefold higher prevalence of MO. Current manual screening grading schemes that ignore visual acuity or the presence of M/DHs could be improved by taking these into account. Health service costs increase substantially with more sensitive/less specific strategies. A fully automated strategy, using the automated detection of patterns of photographic surrogate markers, is superior to all current manual grading schemes for detecting MO in people with diabetes. The addition of optical coherence tomography (OCT) to each strategy, prior to referral, results in a reduction in costs to the health service with no decrement in the number of MO cases detected. Conclusions: Compared with all current manual grading schemes, for the same sensitivity, a fully automated strategy, using the automated detection of patterns of photographic surrogate markers, achieves a higher specificity for detecting MO in people with diabetes, especially if visual acuity is included in the automated strategy. Overall, costs to the health service are likely to increase if more sensitive referral strategies are adopted over more specific screening strategies for MO, for only very small gains in QALYs. The addition of OCT to each screening strategy, prior to referral, results in a reduction in costs to the health service with no decrement in the number of MO cases detected. © Queen's Printer and Controller of HMSO 2013.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The peak-to-average power ratio (PAPR) and optical beat interference (OBI) effects are examined thoroughly in orthogonal frequency-division multiplexing access (OFDMA)-passive optical networks (PONs) at a signal bit rate up to ∼ 20 Gb/s per channel using cost-effective intensity-modulation and direct-detection (IM/DD). Single-channel OOFDM and upstream multichannel OFDM-PONs are investigated for up to six users. A number of techniques for mitigating the PAPR and OBI effects are presented and evaluated including adaptive-loading algorithms such as bit/power-loading, clipping for PAPR reduction, and thermal detuning (TD) for the OBI suppression. It is shown that the bit-loading algorithm is a very efficient PAPR reduction technique by reducing it at about 1.2 dB over 100 Km of transmission. It is also revealed that the optimum method for suppressing the OBI is the TD + bit-loading. For a targeted BER of 1 × 10-3, the minimum allowed channel spacing is 11 GHz when employing six users. © 2013 Springer Science+Business Media New York.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A cost-effective radio over fiber system to up-convert and transmit multigigabit signals at 60 GHz is presented. A low intermediate frequency OFDM signal is used to directly modulate a laser, which is combined with an independent unmodulated laser. The generated millimeter wave frequency can be adjusted by tuning the frequency separation between the lasers. Since no external modulator is required, this technique is low-cost and it is easily integrable in a single chip. In this paper, we present numerical results showing the feasibility of generating an IEEE 802.15.3c compliant 3.5-Gbps 60-GHz OFDM. We show that received signal quality is not limited by the lasers' linewidth but by the relative intensity noise. © 2013 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Optical fibre based sensors are transforming industry by permitting monitoring in hitherto inaccessible environments or measurement approaches that cannot be reproduced using conventional electronic sensors. A multitude of techniques have been developed to render the fibres sensitive to a wide range of parameters including: temperature, strain, pressure (static and dynamic), acceleration, rotation, gas type, and specific biochemical species. Constructed entirely of glass or polymer material, optical fibre devices like fibre gratings offer the properties: low loss, dielectric construction, small size, multiplexing, and so on [1-3]. In this paper, the authors will show the latest developing industrial applications, using polymer optical fibre (POF) devices, and comparing their performance with silica optical fibre devices. The authors address two pressing commercial requirements. The first concerns the monitoring of fuel level in civil aircraft. There is a strong motivation in the aerospace industry to move away from electrical sensors, especially in the fuel system. This is driven by the need to eliminate potential ignition hazards, the desire to reduce cabling weight and the need to mitigate the effects of lightning strikes in aircraft where the conventional metallic skin is increasingly being replaced by composite materials. In this case, the authors have developed pressure sensors based on a diaphragm in which a polymer fibre Bragg grating (POFBG) has been embedded [3]. These devices provide high pressure sensitivity enabling level measurement in the mm range. Also, it has developed an approach incorporating several such sensors which can compensate for temperature drifts and is insensitive to fluid density. Compared with silica fibre-based sensors, their performance is highly enhanced. Initial results have attracted the interest of Airbus from UK, who is keen to explore the potential of optical technology in commercial aircraft. The second concerns the monitoring of acoustic signals and vibration in the subsea environment, for applications in geophysical surveying and security (detection of unwanted craft or personnel). There is strong motivation to move away from electrical sensors due to the bulk of the sensor and associated cabling and the impossibility of monitoring over large distances without electrical amplification. Optical approaches like optical hydrophones [5] offer a means of overcoming these difficulties. In collaboration with Kongsberg from Norway, the authors will exploit the sensitivity improvements possible by using POF instead of silica fibre. These improvements will arise as a result of the much more compliant nature of POF compared to silica fibre (3 GPa vs 72 GPa, respectively). Essentially, and despite the strain sensitivity of silica and POFBGs being very similar, this renders the POF much more sensitive to the applied stress resulting from acoustic signals or vibration. An alternative way of viewing this is that the POF is better impedance-matched to the surrounding environment (water for the intended applications), because although its impedance is higher than that of water, it is nearly an order of magnitude smaller than that of silica. Finally, other future industrial applications will be presented and discussed, showing the vast range of the optical fiber devices in sensing applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The stress sensitivity of polymer optical fibre (POF) based Fabry-Perot sensors formed by two uniform Bragg gratings with finite dimensions is investigated. POF has received high interest in recent years due to its different material properties compared to its silica counterpart. Biocompatibility, a higher failure strain and the highly elastic nature of POF are some of the main advantages. The much lower Young’s modulus of polymer materials compared to silica offers enhanced stress sensitivity to POF based sensors which renders them great candidates for acoustic wave receivers and any kind of force detection. The main drawback in POF technology is perhaps the high fibre loss. In a lossless fibre the sensitivity of an interferometer is proportional to its cavity length. However, the presence of the attenuation along the optical path can significantly reduce the finesse of the Fabry-Perot interferometer and it can negatively affect its sensitivity at some point. The reflectivity of the two gratings used to form the interferometer can be also reduced as the fibre loss increases. In this work, a numerical model is developed to study the performance of POF based Fabry-Perot sensors formed by two uniform Bragg gratings with finite dimensions. Various optical and physical properties are considered such as grating physical length, grating effective length which indicates the point where the light is effectively reflected, refractive index modulation of the grating, cavity length of the interferometer, attenuation and operating wavelength. Using this model, we are able to identify the regimes in which the PMMA based sensor offer enhanced stress sensitivity compared to silica based one.