942 resultados para multimode sample introduction system
Resumo:
BACKGROUND: Frequent emergency department users represent a small number of patients but account for a large number of emergency department visits. They should be a focus because they are often vulnerable patients with many risk factors affecting their quality of life (QoL). Case management interventions have resulted in a significant decrease in emergency department visits, but association with QoL has not been assessed. One aim of our study was to examine to what extent an interdisciplinary case management intervention, compared to standard emergency care, improved frequent emergency department users' QoL. METHODS: Data are part of a randomized, controlled trial designed to improve frequent emergency department users' QoL and use of health-care resources at the Lausanne University Hospital, Switzerland. In total, 250 frequent emergency department users (≥5 attendances during the previous 12 months; ≥ 18 years of age) were interviewed between May 2012 and July 2013. Following an assessment focused on social characteristics; social, mental, and somatic determinants of health; risk behaviors; health care use; and QoL, participants were randomly assigned to the control or the intervention group (n=125 in each group). The final sample included 194 participants (20 deaths, 36 dropouts, n=96 in the intervention group, n=99 in the control group). Participants in the intervention group received a case management intervention by an interdisciplinary, mobile team in addition to standard emergency care. The case management intervention involved four nurses and a physician who provided counseling and assistance concerning social determinants of health, substance-use disorders, and access to the health-care system. The participants' QoL was evaluated by a study nurse using the WHOQOL-BREF five times during the study (at baseline, and at 2, 5.5, 9, and 12 months). Four of the six WHOQOL dimensions of QoL were retained here: physical health, psychological health, social relationship, and environment, with scores ranging from 0 (low QoL) to 100 (high QoL). A linear, mixed-effects model with participants as a random effect was run to analyze the change in QoL over time. The effects of time, participants' group, and the interaction between time and group were tested. These effects were controlled for sociodemographic characteristics and health-related variables (i.e., age, gender, education, citizenship, marital status, type of financial resources, proficiency in French, somatic and mental health problems, and behaviors at risk).
Resumo:
BACKGROUND/RATIONALE: Patient safety is a major concern in healthcare systems worldwide. Although most safety research has been conducted in the inpatient setting, evidence indicates that medical errors and adverse events are a threat to patients in the primary care setting as well. Since information about the frequency and outcomes of safety incidents in primary care is required, the goals of this study are to describe the type, frequency, seasonal and regional distribution of medication incidents in primary care in Switzerland and to elucidate possible risk factors for medication incidents. Label="METHODS AND ANALYSIS" ="METHODS"/> <AbstractText STUDY DESIGN AND SETTING: We will conduct a prospective surveillance study to identify cases of medication incidents among primary care patients in Switzerland over the course of the year 2015. PARTICIPANTS: Patients undergoing drug treatment by 167 general practitioners or paediatricians reporting to the Swiss Federal Sentinel Reporting System. INCLUSION CRITERIA: Any erroneous event, as defined by the physician, related to the medication process and interfering with normal treatment course. EXCLUSION CRITERIA: Lack of treatment effect, adverse drug reactions or drug-drug or drug-disease interactions without detectable treatment error. PRIMARY OUTCOME: Medication incidents. RISK FACTORS: Age, gender, polymedication, morbidity, care dependency, hospitalisation. STATISTICAL ANALYSIS: Descriptive statistics to assess type, frequency, seasonal and regional distribution of medication incidents and logistic regression to assess their association with potential risk factors. Estimated sample size: 500 medication incidents. LIMITATIONS: We will take into account under-reporting and selective reporting among others as potential sources of bias or imprecision when interpreting the results. ETHICS AND DISSEMINATION: No formal request was necessary because of fully anonymised data. The results will be published in a peer-reviewed journal. TRIAL REGISTRATION NUMBER: NCT0229537.
Resumo:
Workflow technology is expanding rapidly. In doing so, new technologies are employed. The internet, which is one such technology, could allow every user within an organization to make use of workflow. The internet- based workflows are discussed in this thesis from technical and, also, from economical points of view. First, as an ampler introduction, there are presented the basic concepts related to this topic: the workflow concept, about processes and workflows and the workflow management system. Also in this introduction it is discussed about the XML language and the overview of the Web Services stack. Then is explained how the internet-based workflows work: is presented the architecture of an internet-based enterprise and, also, the flows between web-services. Finally, there are presented, briefly, some workflow languages. In addition, based on this knowledge, a sample workflow was implemented.
Resumo:
PURPOSE: Adequate empirical antibiotic dose selection for critically ill burn patients is difficult due to extreme variability in drug pharmacokinetics. Therapeutic drug monitoring (TDM) may aid antibiotic prescription and implementation of initial empirical antimicrobial dosage recommendations. This study evaluated how gradual TDM introduction altered empirical dosages of meropenem and imipenem/cilastatin in our burn ICU. METHODS: Imipenem/cilastatin and meropenem use and daily empirical dosage at a five-bed burn ICU were analyzed retrospectively. Data for all burn admissions between 2001 and 2011 were extracted from the hospital's computerized information system. For each patient receiving a carbapenem, episodes of infection were reviewed and scored according to predefined criteria. Carbapenem trough serum levels were characterized. Prior to May 2007, TDM was available only by special request. Real-time carbapenem TDM was introduced in June 2007; it was initially available weekly and has been available 4 days a week since 2010. RESULTS: Of 365 patients, 229 (63%) received antibiotics (109 received carbapenems). Of 23 TDM determinations for imipenem/cilastatin, none exceeded the predefined upper limit and 11 (47.8%) were insufficient; the number of TDM requests was correlated with daily dose (r=0.7). Similar numbers of inappropriate meropenem trough levels (30.4%) were below and above the upper limit. Real-time TDM introduction increased the empirical dose of imipenem/cilastatin, but not meropenem. CONCLUSIONS: Real-time carbapenem TDM availability significantly altered the empirical daily dosage of imipenem/cilastatin at our burn ICU. Further studies are needed to evaluate the individual impact of TDM-based antibiotic adjustment on infection outcomes in these patients.
Resumo:
The present study analyses the relationship between Anxiety and Impulsivity personality factors and emotions, by controlling for country and sex effects in a sample of Spanish and Swiss university students. Emotions were assessed through the International Affective Picture System (IAPS) of pictures (valence/arousal) using the Self-Assessment Manikin (SAM) procedure. The mixed valence/arousal groups' pictures were formed according to Tok, Koyuncu, Dural and Catikkas procedure (2010). Results showed that females scored significantly higher in Anxiety factor and men in Impulsivity factor in both countries. The effect of sex was highly significant for Anxiety (ŋ2: 0.12), but there was no significant effect of the country. Also, females obtained higher scores in the four valence/arousal pictures groups. The sex effect was particularly robust for negative valence-high arousal (ŋ2: 0.13). Impulsivity correlated with high ratings of positive valence-high arousal while Anxiety correlated with high ratings of negative valence-high arousal and with high ratings of negative valence-low arousal in both sexes, although scores were higher for females. Structural Equation Modelling confirmed these relationships. Nevertheless, Anxiety and Impulsivity explained only a small amount of the accounted variance of the self-reported valence and arousal of the pictures.
Resumo:
A photonic system has been developed that enables sensitive quantitative determination of reactive oxygen species (ROS) - mainly hydrogen peroxide (H2O2) - in aerosol samples such as airborne nanoparticles and exhaled air from patients. The detection principle relies on the amplification of the absorbance under multiple scattering conditions due to optical path lengthening [1] and [2]. In this study, the presence of cellulose membrane that acts as random medium into the glass optical cell considerably improved the sensitivity of the detection based on colorimetric FOX assay (FeII/orange xylenol). Despite the loss of assay volume (cellulose occupies 75% of cell volume) the limit of detection is enhanced by one order of magnitude reaching the value of 9 nM (H2O2 equivalents). Spectral analysis is performed automatically with a periodicity of 5 to 15 s, giving rise to real-time ROS measurements. Moreover, the elution of air sample into the collection chamber via a micro-diffuser (impinger) enables quantitative determination of ROS contained in or generated from airborne samples. As proof-of-concept the photonic ROS detection system was used in the determination of both ROS generated from traffic pollution and ROS contained in the exhaled breath as lung inflammation biomarkers.
Resumo:
INTRODUCTION: Dispatch-assisted cardiopulmonary resuscitation (DA-CPR) plays a key role in out-of-hospital cardiac arrests. We sought to measure dispatchers' performances in a criteria-based system in recognizing cardiac arrest and delivering DA-CPR. Our secondary purpose was to identify the factors that hampered dispatchers' identification of cardiac arrests, the factors that prevented them from proposing DA-CPR, and the factors that prevented bystanders from performing CPR. METHODS AND RESULTS: We reviewed dispatch recordings for 1254 out-of-hospital cardiac arrests occurring between January 1, 2011 and December 31, 2013. Dispatchers correctly identified cardiac arrests in 71% of the reviewed cases and 84% of the cases in which they were able to assess for patient consciousness and breathing. The median time to recognition of the arrest was 60s. The median time to start chest compression was 220s. CONCLUSIONS: This study demonstrates that performances from a criteria-based dispatch system can be similar to those from a medical-priority dispatch system regarding out-of-hospital cardiac arrest (OHCA) time recognition and DA-CPR delivery. Agonal breathing recognition remains the weakest link in this sensitive task in both systems. It is of prime importance that all dispatch centers tend not only to implement DA-CPR but also to have tools to help them reach this objective, as today it should be mandatory to offer this service to the community. In order to improve benchmarking opportunities, we completed previously proposed performance standards as propositions.
Resumo:
Automation was introduced many years ago in several diagnostic disciplines such as chemistry, haematology and molecular biology. The first laboratory automation system for clinical bacteriology was released in 2006, and it rapidly proved its value by increasing productivity, allowing a continuous increase in sample volumes despite limited budgets and personnel shortages. Today, two major manufacturers, BD Kiestra and Copan, are commercializing partial or complete laboratory automation systems for bacteriology. The laboratory automation systems are rapidly evolving to provide improved hardware and software solutions to optimize laboratory efficiency. However, the complex parameters of the laboratory and automation systems must be considered to determine the best system for each given laboratory. We address several topics on laboratory automation that may help clinical bacteriologists to understand the particularities and operative modalities of the different systems. We present (a) a comparison of the engineering and technical features of the various elements composing the two different automated systems currently available, (b) the system workflows of partial and complete laboratory automation, which define the basis for laboratory reorganization required to optimize system efficiency, (c) the concept of digital imaging and telebacteriology, (d) the connectivity of laboratory automation to the laboratory information system, (e) the general advantages and disadvantages as well as the expected impacts provided by laboratory automation and (f) the laboratory data required to conduct a workflow assessment to determine the best configuration of an automated system for the laboratory activities and specificities.
Resumo:
Peer-reviewed
Resumo:
A flow system coupled to a tungsten coil atomizer in an atomic absorption spectrometer (TCA-AAS) was developed for As(III) determination in waters, by extraction with sodium diethyldithiocarbamate (NaDDTC) as complexing agent, and by sorption of the As(III)-DDTC complex in a micro-column filled with 5 mg C18 reversed phase (10 µL dry sorbent), followed by elution with ethanol. A complete pre-concentration/elution cycle took 208 s, with 30 s sample load time (1.7 mL) and 4 s elution time (71 µL). The interface and software for the synchronous control of two peristaltic pumps (RUN/ STOP), an autosampler arm, seven solenoid valves, one injection valve, the electrothermal atomizer and the spectrometer Read function were constructed. The system was characterized and validated by analytical recovery studies performed both in synthetic solutions and in natural waters. Using a 30 s pre-concentration period, the working curve was linear between 0.25 and 6.0 µg L-1 (r = 0.9976), the retention efficiency was 94±1% (6.0 µg L-1), and the pre-concentration coefficient was 28.9. The characteristic mass was 58 pg, the mean repeatability (expressed as the variation coefficient) was 3.4% (n=5), the detection limit was 0.058 µg L-1 (4.1 pg in 71 µL of eluate injected into the coil), and the mean analytical recovery in natural waters was 92.6 ± 9.5 % (n=15). The procedure is simple, economic, less prone to sample loss and contamination and the useful lifetime of the micro-column was between 200-300 pre-concentration cycles.
Resumo:
We make a comparative study of payment systems for E.U. -fifteen countries for the 1996-2002 period. Special attention is paid to the introduction of the new European single currency. The overall trend in payments is for a move from cash to noncash payment instruments, although electronic instruments are not widely used yet. We find a significant impact from the introduction of the new banknotes and coins on card use
Resumo:
Phenomena with a constrained sample space appear frequently in practice. This is the case e.g. with strictly positive data, or with compositional data, like percentages or proportions. If the natural measure of difference is not the absolute one, simple algebraic properties show that it is more convenient to work with a geometry different from the usual Euclidean geometry in real space, and with a measure different from the usual Lebesgue measure, leading to alternative models which better fit the phenomenon under study. The general approach is presented and illustrated using the normal distribution, both on the positive real line and on the D-part simplex. The original ideas of McAlister in his introduction to the lognormal distribution in 1879, are recovered and updated
Resumo:
The present paper reports a bacteria autonomous controlled concentrator prototype with a user-friendly interface for bench-top applications. It is based on a micro-fluidic lab-on-a-chip and its associated custom instrumentation, which consists in a dielectrophoretic actuator, to pre-concentrate the sample, and an impedance analyser, to measure concentrated bacteria levels. The system is composed by a single micro-fluidic chamber with interdigitated electrodes and a instrumentation with custom electronics. The prototype is supported by a real-time platform connected to a remote computer, which automatically controls the system and displays impedance data used to monitor the status of bacteria accumulation on-chip. The system automates the whole concentrating operation. Performance has been studied for controlled volumes of Escherichia coli (E. coli) samples injected into the micro-fluidic chip at constant flow rate of 10 μL/min. A media conductivity correcting protocol has been developed, as the preliminary results showed distortion of the impedance analyser measurement produced by bacterial media conductivity variations through time. With the correcting protocol, the measured impedance values were related to the quantity of bacteria concentrated with a correlation of 0.988 and a coefficient of variation of 3.1%. Feasibility of E. coli on-chip automated concentration, using the miniaturized system, has been demonstrated. Furthermore, the impedance monitoring protocol had been adjusted and optimized, to handle changes in the electrical properties of the bacteria media over time.
Resumo:
A simple and sensitive on-line flow injection system for determination of zinc with FAAS has been described. The method is based on the separation and preconcentration of zinc on a microcolumn of immobilized Alizarin Red S on alumina. The adsorbed analyte is then eluted with 250 µL of nitric acid (1 mol L-1) and is transported to flame atomic absorption spectrometer for quantification. The effect of pH, sample and eluent flow rates and presence of various cations and anions on the retention of zinc was investigated. The sorption of zinc was quantitative in the pH range of 5.5-8.5. For a sample volume of 25 mL an enrichment factor of 144 and a detection limit (3S) of 0.2 µg L-1 was obtained. The precision (RSD, n=7) was 3.0% at the 20 µg L-1 level. The developed system was successfully applied to the determination of zinc in water samples, hair, urine and saliva.
Resumo:
In the current economy situation companies try to reduce their expenses. One of the solutions is to improve the energy efficiency of the processes. It is known that the energy consumption of pumping applications range from 20 up to 50% of the energy usage in the certain industrial plants operations. Some studies have shown that 30% to 50% of energy consumed by pump systems could be saved by changing the pump or the flow control method. The aim of this thesis is to create a mobile measurement system that can calculate a working point position of a pump drive. This information can be used to determine the efficiency of the pump drive operation and to develop a solution to bring pump’s efficiency to a maximum possible value. This can allow a great reduction in the pump drive’s life cycle cost. In the first part of the thesis, a brief introduction in the details of pump drive operation is given. Methods that can be used in the project are presented. Later, the review of available platforms for the project implementation is given. In the second part of the thesis, components of the project are presented. Detailed description for each created component is given. Finally, results of laboratory tests are presented. Acquired results are compared and analyzed. In addition, the operation of created system is analyzed and suggestions for the future development are given.