941 resultados para isothermal titration calorimetry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The annealing of ion implantation damage in silicon by rapid isothermal heating has been monitored by the time resolved reflectivity (TRR) method. This technique was applied simultaneously at a wavelength of 632. 8nm and also at 1152nm, where the optical absorption coefficient of silicon is less. The two wavelength method simplifies the interpretation of TRR results, extends the measurement depth and allows good resolution of the position of the interface between amorphous and crystalline silicon. The regrowth of amorphous layers in silicon, created by self implantation and implanted with electrically active impurities, was observed. Regrowth in rapid isothermal annealing occurs during the heating up stage of typical thermal cycles. Impurities such as B, P, and As increase the regrowth rate in a manner consistent with a vacancy model for regrowth. The maximum regrowth rate in boron implanted silicon is limited by the solid solubility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The annealing behaviour of B implants in the millisecond time regime using a combination of swept line beam and background heating is compared with isothermal annealing with heating cycles of a few seconds. Carrier concentration profiles show that under annealing conditions which restrict diffusion, millisecond processing gives higher activation of B implants than isothermal heating. Transmission electron microscopy shows that millisecond annealing also results in a lower defect density.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adopting square wave excitation to drive induction motors (IMs) can substantially reduce inverter switching losses. However, the low-order time harmonics inherent in the output voltage generates parasitic torques that degrade motor performance and reduce efficiency. In this paper, a novel harmonic elimination modulation technique with full voltage control is studied as an interesting and alternative means of operating small (<1kW) IM drives efficiently. A fully verified harmonic elimination scheme, which removes the 5th, 7th, 11th, 13th and 17 th time harmonics, was implemented and applied to an IGBT driven IM. The power losses incurred in the inverter and the IM as a result of the switching scheme have been determined. © 2008 Crown copyright.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We observe the formation of metastable AuGe phases without quenching, during strictly isothermal nucleation and growth of Ge nanowires, using video-rate lattice-resolved environmental transmission electron microscopy. We explain the unexpected formation of these phases through a novel pathway involving changes in composition rather than temperature. The metastable catalyst has important implications for nanowire growth, and more broadly, the isothermal process provides both a new approach to growing and studying metastable phases, and a new perspective on their formation. © 2012 American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The computation of both transient and steady turbulent incompressible isothermal flows is studied. The flow is very complex, having streamline curvature, large vortex structures and stagnation resulting from an impinging rectangular jet. For transient computations, the standard k-ε model is adopted. For steady flows, the k-ε, high and low Reynolds number k-l and mixing length models are tried. Zonal approaches combining the above turbulence models are also investigated. None of the models are found to give satisfactory agreement with velocity measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power-time curves and metabolic properties of Tetrahymena thermophila BF5 exposed to different Yb3+ stop levels were studied by ampoule method of isothermal calorimetry at 28 degrees C. Metabolic rate (r) decreased significantly while peak time (PT) increased with the increase of Yb3+ stop. These results were mainly due to the inhibition of cell growth, which corresponded to the decrease of cell number obtained by cell counting. Compared with cell counting, calorimetry was sensible, easy to use and convenient for monitoring the toxic effects of Yb3+ stop on cells and freshwater ecosystem. It was also found that cell membrane fluidity decreased significantly under the effects of Yb3+ stop, which indicated that Yb3+ could be membrane active molecules with its effect on cell membranes as fundamental aspect of its toxicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using isothermal microcalorimetry, the growth power-time curves of three strains of Tetrahymena were determined at 28 degrees C. Their Euclidean distances and cluster analysis diagram were obtained by using two thermokinetic parameters (r and Q(log)), which showed that T. thermophila BF1 and T. thermophila BF5 had a closer relationship. Compared with the single molecular biomarker (ITS1) method, microcalorimetry wasmaybe a simpler, more sensitive andmore economic technique in the phylogenetic studies of Tetrahymena species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combined with the national standard biomonitoring method (polyurethane foam units method), calorimetry was applied to study the metabolic activities of PFU microbial communities in fresh water to determine the effects of anthropotgenic stresses on the activity of the microbial community. Comparisons were made at four sampling stations with different eutrophic status in Lake Donghu. Water quality variables, species number of protozoa, abundances of microorganisms, biomass, heterotrophy indexes and diversity indexes are reported. The heat rate-time curves of the native and concentrated PFU microbial communities were determined at 28 degrees C. Growth rate, measured maximum power output and total heat were calculated from the heat rate-time curves. The values of metabolic variables are higher at the more eutrophic stations, which suggests that organic pollution increases the activity of PFU microbial communities. The metabolic variables are in good agreement with chemical and biotic variables. And calorimetry will be useful for biomonitoring of the PFU microbial community. (C) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural relaxation by isothermal annealing below the glass transition temperature is conducted on a Zr64.13Cu15.75Ni10.12Al10 bulk metallic glass. The effect of structural relaxation on thermal and mechanical properties was investigated by differential scanning calorimetry and instrumented nanoindentation. The recovery of the enthalpy in the DSC curves indicates that thermally unstable defects were annihilated through structural relaxation. During nanoindentation, the structural relaxation did not have a significant influence on the serrated plastic flow behavior. However, Structural relaxation shows an obvious effect in increasing both the hardness and elastic modulus, which is attributed to the annihilation of thermally unstable defects that resulted from the relaxation.