989 resultados para instrument test
Resumo:
To determine which species and populations of Anopheles transmit malaria in any given situation, immunological assays for malaria sporozoite antigen can replace traditional microscopical examination of freshly dissected Anopheles. We developed a wicking assay for use with mosquitoes that identifies the presence or absence of specific peptide epitopes of circumsporozoite (CS) protein of Plasmodium falciparum and two strains of Plasmodium vivax (variants 210 and 247). The resulting assay (VecTest(TM) Malaria) is a rapid, one-step procedure using a 'dipstick' test strip capable of detecting and distinguishing between P. falciparum and P. vivax infections in mosquitoes. The objective of the present study was to test the efficacy, sensitivity, stability and field-user acceptability of this wicking dipstick assay. In collaboration with 16 test centres world-wide, we evaluated more than 40 000 units of this assay, comparing it to the standard CS ELISA. The 'VecTest(TM) Malaria' was found to show 92% sensitivity and 98.1% specificity, with 97.8% accuracy overall. In accelerated storage tests, the dipsticks remained stable for >15 weeks in dry conditions up to 45degreesC and in humid conditions up to 37degreesC. Evidently, this quick and easy dipstick test performs at an acceptable level of reliability and offers practical advantages for field workers needing to make rapid surveys of malaria vectors.
Resumo:
The purpose of this study was to quantify the sagittal angular displacement of the head (cranio-cervical flexion) for the five incremental stages of the cranio-cervical flexion test (CCFT). Range of cranio-cervical flexion during the CCFT was measured using a digital imaging method in 20 healthy volunteer subjects. The intra- and inter-rater reliability of the digital imaging technique for the assessment of this movement were also examined. The results of this study demonstrated a linear relationship between the incremental pressure targets of the CCFT and the percentages of full range cranio-cervical flexion range of motion (ROM) measured in the supine lying position of the test using a digital imaging technique. A mean of 22.9% full range cranio-cervical flexion was used to reach the first pressure target of the CCFT followed by linear increments up to 76.6% for the last stage of the test. An increasing amount of cranio-cervical flexion ROM was used to achieve the five successive stages of the CCFT reflecting an increasing contractile demand on the deep cervical flexor muscles. Excellent inter-rater (ICC = 0.994) and intra-rater reliability (ICC = 0.988-0.998) were demonstrated for the angular measurements using this digital imaging technique. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
The Test of Mouse Proficiency (TOMP) was developed to assist occupational therapists and education professionals assess computer mouse competency skills in children from preschool to upper primary (elementary) school age. The preliminary reliability and validity of TOMP are reported in this paper. Methods used to examine the internal consistency, test-retest reliability, and criterion- and construct-related validity of the test are elaborated. In the continuing process of test refinement, these preliminary studies support to varying degrees the reliability and validity of TOMP. Recommendations for further validation of the assessment are discussed along with indications for potential clinical application.
Resumo:
This paper reports a study that explored a new construct: climate of fear. We hypothesised that climate of fear would vary across work sites within organisations, but not across organisations. This is in contrast a to measures of organisational culture, which were expected to vary both within and across organisations. To test our hypotheses, we developed a new 13-item measure of perceived fear in organisations and tested it in 20 sites across two organisations (N = 209). Culture variables measured were innovative leadership culture, and communication culture. Results were that climate of fear did vary across sites in both organisations, while differences across organisations were not significant, as we anticipated. Organisational culture, however, varied between the organisations, and within one of the organisations. The climate of fear scale exhibited acceptable psychometric properties.
Resumo:
Chlorophyll fluorescence measurements have a wide range of applications from basic understanding of photosynthesis functioning to plant environmental stress responses and direct assessments of plant health. The measured signal is the fluorescence intensity (expressed in relative units) and the most meaningful data are derived from the time dependent increase in fluorescence intensity achieved upon application of continuous bright light to a previously dark adapted sample. The fluorescence response changes over time and is termed the Kautsky curve or chlorophyll fluorescence transient. Recently, Strasser and Strasser (1995) formulated a group of fluorescence parameters, called the JIP-test, that quantify the stepwise flow of energy through Photosystem II, using input data from the fluorescence transient. The purpose of this study was to establish relationships between the biochemical reactions occurring in PS II and specific JIP-test parameters. This was approached using isolated systems that facilitated the addition of modifying agents, a PS II electron transport inhibitor, an electron acceptor and an uncoupler, whose effects on PS II activity are well documented in the literature. The alteration to PS II activity caused by each of these compounds could then be monitored through the JIP-test parameters and compared and contrasted with the literature. The known alteration in PS II activity of Chenopodium album atrazine resistant and sensitive biotypes was also used to gauge the effectiveness and sensitivity of the JIP-test. The information gained from the in vitro study was successfully applied to an in situ study. This is the first in a series of four papers. It shows that the trapping parameters of the JIP-test were most affected by illumination and that the reduction in trapping had a run-on effect to inhibit electron transport. When irradiance exposure proceeded to photoinhibition, the electron transport probability parameter was greatly reduced and dissipation significantly increased. These results illustrate the advantage of monitoring a number of fluorescence parameters over the use of just one, which is often the case when the F-V/F-M ratio is used.
Resumo:
Measurement of Health-Related Quality of Life (HRQoL) of the elderly requires instruments with demonstrated sensitivity, reliability, and validity, particularly with the increasing proportion of older people entering the health care system. This article reports the psychometric properties of the 12-item Assessment of Quality of Life (AQoL) instrument in chronically ill community-dwelling elderly people with an 18-month follow-up. Comparator instruments included the SF-36 and the OARS. Construct validity of the AQoL was strong when examined via factor analysis and convergent and divergent validity against other scales. Receiver Operator Characteristic (ROC) curve analyses and relative efficiency estimates indicated the AQoL is sensitive, responsive, and had the strongest predicative validity for nursing home entry. It was also sensitive to economic prediction over the follow-up. Given these robust psychometric properties and the brevity of the scale, AQoL appears to be a suitable instrument for epidemiologic studies where HRQoL and utility data are required from elderly populations. (C) 2003 Elsevier Science Inc. All rights reserved.
Resumo:
This study compares the performance of the Quickscreen and Default protocols of the ILO-96 Otodynamics Analyzer in recording transient evoked otoacoustic emissions (TEOAEs) from adults using clinical decision analysis. Data were collected from 25 males (mean age = 29.0 years, SD = 6.8) and 35 females (mean age = 28.1 years, SD = 9.6). The results showed that the mean signal-to-noise ratios obtained from the Quickscreen were significantly greater than those from the Default protocol at 1,2, and 4 kHz. The comparison of the performance of the two protocols, based on the results using receiver operating characteristics curves, revealed a higher performance of the Quickscreen than the Default protocol at 1 and 4 kHz but not at 2 kHz. In view of the enhanced performance of the Quickscreen over the Default protocol in general, the routine use of the Default protocol for testing adults in audiology clinics should be reconsidered.
Estudantes público-alvo da educação especial na educação em tempo integral : um estudo em Vitória-ES
Resumo:
Este estudo tem como tema “Estudantes Público-Alvo da Educação Especial na Educação em Tempo Integral no Município de Vitoria-ES”. Seu objetivo geral foi investigar os modos de atendimento aos estudantes público-alvo da Educação Especial do Programa Educação em Tempo Integral – Educação Ampliada, oferecido pelo ensino público municipal nas Escolas de Ensino Fundamental (EMEFs) do município de Vitória, pela fala dos gestores e executores do programa. Seus objetivos específicos foram compreender a configuração da proposta de Educação em Tempo Integral – Educação Ampliada no município de Vitória-ES; caracterizar o conjunto de estudantes público-alvo da Educação Especial participantes do Programa Educação em Tempo Integral – Educação Ampliada no município; compreender os sentidos e significados da inclusão de estudantes público-alvo da Educação Especial no Programa Educação em Tempo Integral – Educação Ampliada no município de Vitória-ES. Trata-se de pesquisa qualitativa, cuja metodologia envolveu revisão de literatura e estudo de caso. O instrumento de pesquisa foi uma entrevista semiestruturada, por permitir explorar mais amplamente as abordagens e proporcionar aos entrevistados maior liberdade para emitir as suas opiniões. Os sujeitos da pesquisa foram os gestores responsáveis pelo desenvolvimento do Programa Educação em Tempo Integral – Educação Ampliada da Secretaria Municipal de Educação do município de Vitória (Seme) e a equipe de uma das EMEFs que compôs o grupo focal, profissionais diretamente envolvidos no exercício das práticas pedagógicas com os estudantes matriculados no Programa da Unidade de Ensino. Os resultados das análises da pesquisa foi que a Educação em Tempo Integral – Educação Ampliada é uma realidade no município de Vitória-ES, desde a sua implantação em 1989. O programa atende hoje a 3.203 estudantes. Desse total, apenas 35, ou seja, 1,9%, compõem o público-alvo da Educação Especial atendido pelo programa em foco. A análise das informações documentais, os relatos dos gestores que se revezaram desde a implantação do Peti e as entrevistas com os sujeitos desta pesquisa revelaram que a educação em tempo integral se processa no município de Vitória de forma lenta e descontínua, especialmente por ocasião do revezamento entre uma administração e outra, quando muda a gestão política.
Resumo:
Introduction and Objectives. Laparoscopic surgery has undeniable advantages, such as reduced postoperative pain, smaller incisions, and faster recovery. However, to improve surgeons’ performance, ergonomic adaptations of the laparoscopic instruments and introduction of robotic technology are needed. The aim of this study was to ascertain the influence of a new hand-held robotic device for laparoscopy (HHRDL) and 3D vision on laparoscopic skills performance of 2 different groups, naïve and expert. Materials and Methods. Each participant performed 3 laparoscopic tasks—Peg transfer, Wire chaser, Knot—in 4 different ways. With random sequencing we assigned the execution order of the tasks based on the first type of visualization and laparoscopic instrument. Time to complete each laparoscopic task was recorded and analyzed with one-way analysis of variance. Results. Eleven experts and 15 naïve participants were included. Three-dimensional video helps the naïve group to get better performance in Peg transfer, Wire chaser 2 hands, and Knot; the new device improved the execution of all laparoscopic tasks (P < .05). For expert group, the 3D video system benefited them in Peg transfer and Wire chaser 1 hand, and the robotic device in Peg transfer, Wire chaser 1 hand, and Wire chaser 2 hands (P < .05). Conclusion. The HHRDL helps the execution of difficult laparoscopic tasks, such as Knot, in the naïve group. Three-dimensional vision makes the laparoscopic performance of the participants without laparoscopic experience easier, unlike those with experience in laparoscopic procedures.
Resumo:
This paper examines the nature of the construct of consumers' trust toward the electronic channel of their financial institution. Through a study of a total of 372 individual users of Internet banking in Spain, we have managed to develop a third-order measuring instrument that integrates a total of seven dimensions. The exploratory and confirmatory factor analyses were used to test the validation and reliability of the proposed scale. Findings provide useful information to professionals who seek to identify how customer's trust is formed in the online channel and in the financial sector.
Resumo:
Foi aplicada uma versão reduzida do "Face-Hand Test", o FHT-R, em 91 pessoas com 65 anos ou mais em uma amostra ao acaso de idosos vivendo na comunidade (São Paulo, Brasil), com objetivo de testar a habilidade do instrumento em detectar as síndromes psicorgânicas. Os escores do FHT-R foram comparados com as avaliações de um psiquiatra utilizando uma entrevista semi-estruturada, a "Clinical Interview Schedule". Cinco pessoas foram consideradas como sendo portadoras de distúrbios psicorgânicos e 86 como não sendo portadoras de tais distúrbios. No ponto de corte 0/1 os coeficientes de validação obtidos foram: sensibilidade 60%, especificidade 94%, valor prognóstico positivo 38%, valor prognóstico negativo 98%, e taxa de classificação incorreta 8%. A utilização do Teste em pesquisas epidemiológicas é discutida no corpo do trabalho.
Resumo:
This paper studies the application of commercial biocides to old maritime pine timber structures (Pinus pinaster Ait.) that have previously been impregnated with other products. A method was developed in the laboratory to be used in situ to determine the impregnation depth achieved by a new generation biocide product applied to timber from an old building. This timber had once been treated with an unknown product difficult to characterize without extensive analysis. The test was initially developed in laboratory conditions and later tested on elements of the roof structure of an 18th century building. In both cases the results were promising and mutually consistent with penetration depths for some treatments reaching 2.0 cm. The application in situ proved the tests viability and simplicity of execution giving a clear indication on the feasibility of possible re-treatments.