Resumo:
Purpose: During general anesthesia, nitrous oxide (N2O) diffuses rapidly into the air-filled laryngeal mask airway (LMA) cuff, increasing intracuff pressure. There is no clear correlation between LMA intracuff pressure and pressure on the pharynx. We have studied the effects of high LMA intracuff pressures secondary to N2O on the pharyngeal mucosa of dogs.Methods: Sixteen mongrel dogs were randomly allocated to two groups: G1 (intracuff volume, 30 mL; n = 8) breathed a mixture of O-2 (1 L.min(-1)) and air (1 L.min(-1)) and G2 (intracuff volume, 30 mL; n=8) a mixture of O-2 (1 L.min(-1)) and N2O (1 L.min(-1)). Anesthesia was induced and maintained with pentobarbitone. LMA cuff pressure was measured at zero (control), 30, 60, 90 and 120 min after #4 LMA insertion. The dogs were sacrificed, and biopsy specimens from seven predetermined areas of the pharynx in contact with the LMA cuff were collected for light (LM) and scanning electron microscopic (SEM) examination by a blinded observer.Results: LMA intracuff pressure decreased with time in G1 (P < 0.001) and increased in G2 (P < 0.001). There was a significant difference between the groups (P < 0.001). In both groups, the LM study showed a normal epithelium covering the pharyngeal mucosa and mild congestion in the subepithelial layer There were no differences between the groups (P > 0.10) or among the areas sampled (P > 0.05). In both groups, the SEM study showed a normal pharyngeal mucosa with mild superficial desquamation. Few specimens in G1 and G2 showed more intense epithelial desquamation.Conclusion: High LMA intracuff pressures produced by N2O do not increase pharyngeal mucosal injury in dogs.
Resumo:
Objective To compare the cardiorespiratory effects and incidence of gastroesophageal reflux with the use of a laryngeal mask airway (LMA) or endotracheal tube (ET) in anesthetized cats during spontaneous (SV) or controlled ventilation (CV).Study design Prospective randomized experimental trial.Animals Thirty-two adult crossbred cats, weighing 2.7 +/- 0.4 kg.Methods the cats were sedated with intramuscular (IM) methotrimeprazine (0.5 mg kg(-1)) and buprenorphine (0.005 mg kg(-1)), followed 30 minutes later by induction of anesthesia with intravenous (IV) thiopental (12.5-20 mg kg(-1)). An ET was used in 16 cats and an LMA in the remaining 16 animals. Anesthesia was maintained with 0.5 minimum alveolar concentration (0.6%) of halothane in oxygen using a Mapleson D breathing system. Cats in both groups were further divided into two equal groups (n = 8), undergoing either SV or CV. Neuromuscular blockade with pancuronium (0.06 mg kg(-1)) was used to facilitate CV. Heart and respiratory rates, direct arterial blood pressure, capnometry (PE'CO2) and arterial blood gases were measured. Gastric reflux and possible aspiration was investigated by intragastric administration of 5 mL of radiographic contrast immediately after induction of anesthesia. Cervical and thoracic radiographs were taken at the end of anesthesia. Data were analyzed using ANOVA followed by Student-Newman-Keuls, Kruskal-Wallis or Friedman test where appropriate.Results Values for PaCO2 and PE'CO2 were higher in spontaneously breathing cats with the LMA when compared with other groups. Values of PaO2 and hemoglobin oxygen saturation did not differ between groups. Gastroesophageal reflux occurred in four of eight and two of eight cats undergoing CV with ET or LMA, respectively. There was no tracheal or pulmonary aspiration in any cases.Conclusions and clinical relevance the use of an LMA may be used as an alternative to endotracheal intubation in anesthetized cats. Although aspiration was not observed, gastric reflux may occur in mechanically ventilated animals.
Resumo:
Halothane depresses cardiorespiratory function and activates the pituitary-adrenal axis, increasing beta endorphin. In horses, beta endorphin may enhance the anaesthetic-associated cardiorespiratory depression and mortality risk. The authors studied endogenous opioid effects on cardiorespiratory function and pituitary-adrenal activity in halothane-anaesthetised ponies by investigating opioid antagonism by naloxone. Six ponies were anaesthetised three times (crossover design). Anaesthesia was induced with thiopentone and maintained with 1.2 per cent halothane for 2 hours. Immediately after induction, naloxone was administered either intra venously (0.5 mg kg(-1) bolus then 0.25 mg kg(-1) hour(-1) for 2 hours) or intrathecally (0.5 mg) or was replaced by saline as control. Pulse and respiratory rates, arterial blood gases, cardiac output and plasma cortisol and adrenocorticotrophic hormone (ACTH) concentrations were measured. All groups developed cardiorespiratory depression (40 per cent decrease in cardiac output) and plasma cortisol increased. Plasma ACTH concentration was higher in ponies treated with intrathecal naloxone. Endogenous opioids may inhibit ACTH Secretion, attenuating the stress response to halothane anaesthesia in equidae. (C) 2001 Harcourt Publishers Ltd.
Resumo:
Background. This double-blind study was undertaken to determine whether alizapride inhibits spinal morphine-induced pruritus.Methods. Eighty-four patients undergoing Caesarean section under spinal anaesthesia (100 mg of hyperbaric lidocaine 5% plus morphine 0.2 mg) were randomly allocated to one of two groups. just after birth, alizapride-50 mg (alizapride group) or metoclopramide 10 mg (metoclopramide group) were injected i.v. Patients were assessed after surgery for pruritus (absent, mild, moderate or severe) or other untoward symptoms.Results. In the metoclopramide group, pruritus was absent in 5 (12%) patients, mild in 23 (55%), moderate in 11 (26%), and severe in 3 (7%), while in the alizapride group, these incidences were, respectively, 5 (12%), 33 (79%), 4 (10%), and 0 (P=0.045, chi(2)-test). There was no difference in the incidence of side-effects, which were all minor.Conclusions. Alizapride reduced the severity of morphine-induced pruritus.
Resumo:
Background. Little information exists regarding factors influencing perioperative cardiac arrests and their outcome. This survey evaluated the incidence, causes and outcome of perioperative cardiac arrests in a Brazilian tertiary general teaching hospital between April 1996 and March 2005.Methods. The incidence of cardiac arrest during anaesthesia was prospectively identified from an anaesthesia database. There were 53 718 anaesthetics during the study period. Data collected included patient characteristics, surgical procedures (elective, urgent or emergency), ASA physical status classification, anaesthesia provider information, type of surgery, surgical areas and outcome. All cardiac arrests were retrospectively reviewed and grouped by cause of arrest and death into one of four groups: totally anaesthesia related, partially anaesthesia related, totally surgery related or totally patient disease or condition related.Results. One hundred and eighty-six cardiac arrests (34.6:10 000) and 118 deaths (21.97:10 000) were found. Major risk factors for cardiac arrest were neonates, children under 1 yr and the elderly (P < 0.05), male patients with ASA III or poorer physical status (P < 0.05), in emergency surgery (P < 0.05) and under general anaesthesia (P < 0.05). Patient disease/condition was the major cause of cardiac arrest or death (P < 0.05). There were 18 anaesthesia-related cardiac arrests (3.35:10 000)-10 totally attributed (1.86:10 000) and 8 partially related to anaesthesia (1.49:10 000). There were 6 anaesthesia-related deaths (1.12:10 000)-3 totally attributable and 3 partially related to anaesthesia (0.56:10 000 in both cases). The main causes of anaesthesia-related cardiac arrest were respiratory events (55.5%) and medication-related events (44.5%).Conclusions. Perioperative cardiac arrests were relatively higher in neonates, infants, the elderly and in males with severe underlying disease and under emergency surgery. All anaesthesia-related cardiac arrests were related to airway management and medication administration which is important for prevention strategies.
Resumo:
Objective To compare the cardiorespiratory changes induced by equipotent concentrations of halothane (HAL), isoflurane (ISO) and sevollurane (SEVO) before and after hemorrhage.Study design. Prospective, randomized clinical trial.Animals. Twenty-four healthy adult dogs weighing 15.4 +/- 3.4 kg (mean +/- SD).Methods. Animals were randomly allocated to one of three groups (n = 8 per group). In each group, anesthesia was maintained with 1.5 minimum alveolar concentration of HAL (1.3%), ISO (1.9%,) and SEVO (3.5%) in oxygen. Controlled ventilation was performed to maintain eucapnia. Cardiorespiratory variables were evaluated at baseline (between 60 and 90 minutes after induction), immediately after and 30 minutes after the withdrawal of 32 mL kg(-1) of blood (400% of the estimated blood volume) over a 30-minute period.Results. During baseline conditions, ISO and SEVO resulted in higher cardiac index (CI) than HAL. Heart rates were higher with SEVO at baseline. while mean arterial pressure (MAP) and mean pulmonary arterial pressure did not differ between groups. Although heart rate values were higher for ISO and SEVO after hemorrhage, only ISO resulted in a higher CI when compared with HAL. In ISO-anesthetized dogs, MAP was higher immediately after hemorrhage, and this was related to better maintenance of CI and to an increase in systemic vascular resistance index from baseline.Conclusions. Although the hemodynamic responses of ISO and SEVO are similar in normovolaemic dogs, ISO results in better maintenance of circulatory function during the early period following a massive blood loss. Clinical relevance Inhaled anesthetics should be used judiciously in animals presented with blood loss. However, if an inhalational agent is to be used under these circumstances, ISO may provide better hemodynamic stability than SEVO or HAL.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This study compared intubation conditions produced by the Macintosh and AirtraqTM laryngoscopes when used in obese patients in the ramped position. One hundred and thirty-two patients having bariatric surgery were placed in the ramped position and randomly assigned to have their tracheas intubated using either the Macintosh (n = 64) or an Airtraq (n = 68) laryngoscope. Mean (SD) intubation times were 37 (23) s and 14 (3) s for Macintosh and Airtraq, respectively (p < 0.0001). Compared with the Macintosh laryngoscope, the Airtraq laryngoscope provided an improved vocal cord view as assessed by the Cormack and Lehane score (number of patients with Cormack-Lehane scores of 1/2/3/4/37/20/4/3 for the Macintosh, and 65/3/0/0 for the Airtraq laryngoscopes, p < 0.0001). One patient in the Macintosh group had a failed intubation and intubation was achieved with the Airtraq. For obese patients in ramped position, Airtraq affords faster tracheal intubation than the Macintosh laryngoscope.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: Avaliar o uso da oxigenoterapia inalatória em crianças internadas em hospital universitário. MÉTODOS: Estudo prospectivo de crianças atendidas no Pronto-Socorro Pediátrico do Hospital das Clínicas da Faculdade de Medicina de Botucatu e que receberam oxigenoterapia durante a internação, de maio a setembro de 2005. Indicou-se oxigenoterapia se saturação de oxigênio inferior a 90% e frequência respiratória elevada para idade. Crianças em uso crônico de oxigênio ou com necessidade de ventilação mecânica foram excluídas. Foram avaliados: sintomas respiratórios, diagnósticos clínicos, saturação de oxigênio, método e tempo de oxigenoterapia e responsável pela prescrição. RESULTADOS: Foram atendidas 8.709 crianças no pronto-socorro, sendo que 2.769 (32%) apresentaram doenças respiratórias e 97 necessitaram de internação na enfermaria. Destas, 62 (64%) receberam oxigenoterapia. Das 62 crianças, 37 eram do sexo masculino e a idade variou de 2 meses a 14 anos (mediana: 8 meses). A causa de hipóxia foi pneumonia em 52 crianças (84%), asma em cinco, bronquiolite em quatro e traqueomalácia em uma. As prescrições de oxigenoterapia foram feitas por médicos, com monitoração de saturação de oxigênio por oxímetro de pulso. O tempo mediano de administração de O2 foi 6 dias e o cateter nasal foi usado em 94% dos casos, sendo raro o uso de máscaras ou capuz de oxigênio. CONCLUSÕES: A oxigenoterapia inalatória foi mais frequente em crianças com menor idade e em pacientes com pneumonia, sendo sua indicação compatível com critérios internacionais. O uso do cateter nasal mostrou-se seguro, simples, efetivo e de baixo custo.
Resumo:
To evaluate a prototype pressure stimulus device for use in the cat and to compare with a known thermal threshold device.Eight healthy adult cats weighing between 3.0 and 4.9 kg.Pressure stimulation was given via a plastic bracelet taped around the forearm. Three 2.4 mm diameter ball bearings, in a 10-mm triangle, were advanced against the craniolateral surface of the antebrachium by manual inflation of a modified blood pressure bladder. Pressure in the cuff was recorded at the end point (leg shake and head turn). Thermal threshold was also tested. Stimuli were stopped if they reached 55 degrees C or 450 mmHg without response. After four pressure and thermal threshold baselines, each cat received SC buprenorphine 0.01 mg kg(-1), carprofen 4 mg kg(-1) or saline 0.3 mL in a three period cross-over study with a 1-week interval. The investigator was blinded to the treatment. Measurements were made at 0.25. 0.5, 0.75, 1, 2, 3, 4, 6, 8, and 24 hours after injection. Data were analyzed by using ANOVA.There were no significant changes in thermal or pressure threshold after administration of saline or carprofen, but thermal threshold increased from 60 minutes until 8 hours after administration of buprenorphine (p < 0.05). The maximum increase in threshold from baseline (Delta T-max) was 3.5 +/- 3.1 degrees C at 2 hours. Pressure threshold increased 2 hours after administration of buprenorphine (p < 0.05) when the increase in threshold above baseline (Delta P-max) was 162 +/- 189 mmHg.This pressure device resulted in thresholds that were affected by analgesic treatment in a similar manner but to a lesser degree than the thermal method. Pressure stimulation may be a useful additional method for analgesic studies in cats.
Resumo:
Este estudo investigou o efeito da ropivacaína, da lidocaína e da associação de lidocaína e xilazina na anestesia epidural de cães. Trinta cães foram tranqüilizados com acepromazina intravenosa, distribuídos em três grupos e submetidos à anestesia epidural no espaço lombo-sacro, com lidocaína 2% com vasoconstrictor (GL), ropivacaína 1% (GR) ou com xilazina associada à lidocaína (GXL). Mensuraram-se as freqüências cardíaca (FC) e respiratória (f), a pressão arterial sistólica (PAS), a concentração final expirada de CO2 (EtCO2), o volume minuto (VM) e a temperatura retal (T). Para avaliação da analgesia somática, utilizou-se o teste do panículo e o teste térmico a 55°C. Os protocolos produziram anestesia da região retro-umbilical, sendo que a associação XL produziu bloqueio anestésico mais cranial, porém causou bradicardia moderada. A duração da anestesia foi mais prolongada nos animais dos grupos GXL (240 min) e GR (250 min), quando comparada as do grupo GL (120 min).