880 resultados para ibuprofenate-sensitive electrode


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Protease-sensitive macromolecular prodrugs have attracted interest for bio-responsive drug delivery to sites with up-regulated proteolytic activities such as inflammatory or cancerous lesions. Here we report the development of a novel polymeric photosensitizer prodrug (T-PS) to target thrombin, a protease up-regulated in synovial tissues of rheumatoid arthritis (RA) patients, for minimally invasive photodynamic synovectomy. In T-PS, multiple photosensitizer units are tethered to a polymeric backbone via short, thrombin-cleavable peptide linkers. Photoactivity of the prodrug is efficiently impaired due to energy transfer between neighbouring photosensitizer units. T-PS activation by exogenous and endogenous thrombin induced an increase in fluorescence emission by a factor of 16 after in vitro digestion and a selective fluorescence enhancement in arthritic lesions in vivo, in a collagen-induced arthritis mouse model. In vitro studies on primary human synoviocytes showed a phototoxic effect only after enzymatic digestion of the prodrug and light irradiation, thus demonstrating the functionality of T-PS induced PDT. The developed photosensitizer prodrugs combine the passive targeting capacity of macromolecular drug delivery systems with site-selective photosensitizer release and activation. They illuminate lesions with pathologically enhanced proteolytic activity and induce cell death, subsequent to irradiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The available virus-like particle (VLP)-based prophylactic vaccines against specific human papillomavirus (HPV) types afford close to 100% protection against the type-associated lesions and disease. Based on papillomavirus animal models, it is likely that protection against genital lesions in humans is mediated by HPV type-restricted neutralizing antibodies that transudate or exudate at the sites of genital infection. However, a correlate of protection was not established in the clinical trials because few disease cases occurred, and true incident infection could not be reliably distinguished from the emergence or reactivation of prevalent infection. In addition, the current assays for measuring vaccine-induced antibodies, even the gold standard HPV pseudovirion (PsV) in vitro neutralization assay, may not be sensitive enough to measure the minimum level of antibodies needed for protection. Here, we characterize the recently developed model of genital challenge with HPV PsV and determine the minimal amounts of VLP-induced neutralizing antibodies that can afford protection from genital infection in vivo after transfer into recipient mice. Our data show that serum antibody levels >100-fold lower than those detectable by in vitro PsV neutralization assays are sufficient to confer protection against an HPV PsV genital infection in this model. The results clearly demonstrate that, remarkably, the in vivo assay is substantially more sensitive than in vitro PsV neutralization and thus may be better suited for studies to establish correlates of protection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Type 2 diabetes (T2D) is associated with increased fracture risk but paradoxically greater BMD. TBS (trabecular bone score), a novel grey-level texture measurement extracted from DXA images, correlates with 3D parameters of bone micro-architecture. We evaluated the ability of lumbar spine (LS) TBS to account for the increased fracture risk in diabetes. Methods:29,407 women ≥50 years at the time of baseline hip and spine DXA were identified from a database containing all clinical BMD results for the Province of Manitoba, Canada. 2,356 of the women satisfied a well-validated definition for diabetes, the vast majority of whom (>90%) would have T2D. LS L14 TBS was derived for each spine DXA examination blinded to clinical parameters and outcomes. Health service records were assessed for incident non-traumatic major osteoporotic fracture codes (mean follow-up 4.7 years). Results:In linear regression adjusted for FRAX risk factors (age,BMI, glucocorticoids, prior major fracture, rheumatoid arthritis, COPD as a smoking proxy, alcohol abuse) and osteoporosis therapy, diabetes was associated with higher BMD for LS, femoral neck and total hip but lower LS TBS (all p<0.001). Similar results were seen after excluding obese subjects withBMI>30. In logistic regression (Figure), the adjusted odds ratio (OR) for a skeletal measurement in the lowest vs highest tertile was less than 1 for all BMD measurements but increased for LS TBS (adjusted OR 2.61, 95%CI 2.30-2.97). Major osteoporotic fractures were identified in 175 (7.4%) with and 1,493 (5.5%) without diabetes (p < 0.001). LS TBS predicted fractures in those with diabetes (adjusted HR 1.27, 95%CI 1.10-1.46) and without diabetes (HR 1.31, 95%CI 1.24-1.38). LS TBS was an independent predictor of fracture (p<0.05) when further adjusted for BMD (LS, femoral neck or total hip). The explanatory effect of diabetes in the fracture prediction model was greatly reduced when LS TBS was added to the model (indicating that TBS captured a large portion of the diabetes-associated risk), but was paradoxically increased from adding any of the BMD measurements. Conclusions:Lumbar spine TBS is sensitive to skeletal deterioration in postmenopausal women with diabetes, whereas BMD is paradoxically greater. LS TBS predicts osteoporotic fractures in those with diabetes, and captures a large portion of the diabetes-associated fracture risk. Combining LS TBS with BMD incrementally improves fracture prediction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: We examined the analytic validity of reported family history of hypertension and diabetes among siblings in the Seychelles. STUDY DESIGN AND SETTING: Four hundred four siblings from 73 families with at least two hypertensive persons were identified through a national hypertension register. Two gold standards were used prospectively. Sensitivity was the proportion of respondents who indicated the presence of disease in a sibling, given that the sibling reported to be affected (personal history gold standard) or was clinically affected (clinical status gold standard). Specificity was the proportion of respondents who reported an unaffected sibling, given that the sibling reported to be unaffected or was clinically unaffected. Respondents gave information on the disease status in their siblings in approximately two-thirds of instances. RESULTS: When sibling history could be obtained (n=348 for hypertension, n=404 for diabetes), the sensitivity and the specificity of the sibling history were, respectively, 90 and 55% for hypertension, and 61 and 98% for diabetes, using clinical status and, respectively, 89 and 78% for hypertension, and 53 and 98% for diabetes, using personal history. CONCLUSION: The sibling history, when available, is a useful screening test to detect hypertension, but it is less useful to detect diabetes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrical deep brain stimulation (DBS) is an efficient method to treat movement disorders. Many models of DBS, based mostly on finite elements, have recently been proposed to better understand the interaction between the electrical stimulation and the brain tissues. In monopolar DBS, clinically widely used, the implanted pulse generator (IPG) is used as reference electrode (RE). In this paper, the influence of the RE model of monopolar DBS is investigated. For that purpose, a finite element model of the full electric loop including the head, the neck and the superior chest is used. Head, neck and superior chest are made of simple structures such as parallelepipeds and cylinders. The tissues surrounding the electrode are accurately modelled from data provided by the diffusion tensor magnetic resonance imaging (DT-MRI). Three different configurations of RE are compared with a commonly used model of reduced size. The electrical impedance seen by the DBS system and the potential distribution are computed for each model. Moreover, axons are modelled to compute the area of tissue activated by stimulation. Results show that these indicators are influenced by the surface and position of the RE. The use of a RE model corresponding to the implanted device rather than the usually simplified model leads to an increase of the system impedance (+48%) and a reduction of the area of activated tissue (-15%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Posaconazole (POS) is a new antifungal agent for prevention and therapy of mycoses in immunocompromised patients. Variable POS pharmacokinetics after oral dosing may influence efficacy: a trough threshold of 0.5 ?g/ml has been recently proposed. Measurement of POS plasma concentrations by complex chromatographic techniques may thus contribute to optimize prevention and management of life-threatening infections. No microbiological analytical method is available. The objective of this study was to develop and validate a new simplified ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method and a sensitive bioassay for quantification of POS over the clinical plasma concentration range. The UPLC-MS/MS equipment consisted of a triple quadrupole mass spectrometer, an electrospray ionization (ESI) source, and a C(18) analytical column. The Candida albicans POS-hypersusceptible mutant (MIC of 0.002 ?g/ml) ?cdr1 ?cdr2 ?flu ?mdr1 ?can constructed by targeted deletion of multidrug efflux transporters and calcineurin genes was used for the bioassay. POS was extracted from plasma by protein precipitation with acetonitrile-methanol (75%/25%, vol/vol). Reproducible standard curves were obtained over the range 0.014 to 12 (UPLC-MS/MS) and 0.028 to 12 ?g/ml (bioassay). Intra- and interrun accuracy levels were 106% ± 2% and 103% ± 4% for UPLC-MS/MS and 102% ± 8% and 104% ± 1% for bioassay, respectively. The intra- and interrun coefficients of variation were 7% ± 4% and 7% ± 3% for UPLC-MS/MS and 5% ± 3% and 4% ± 2% for bioassay, respectively. An excellent correlation between POS plasma concentrations measured by UPLC-MS/MS and bioassay was found (concordance, 0.96). In 26 hemato-oncological patients receiving oral POS, 27/69 (39%) trough plasma concentrations were lower than 0.5 ?g/ml. The UPLC-MS/MS method and sensitive bioassay offer alternative tools for accurate and precise quantification of the plasma concentrations in patients receiving oral posaconazole.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The toxicity and environmental behavior of new pH-sensitive surfactants from lysine are presented. Three different chemical structures are studied: surfactants with one amino acid and one alkyl chain, surfactants with two amino acids on the polar head and one alkyl chain, and gemini surfactants. The pH sensitivity of these compounds can be tuned by modifying their chemical structures. Cytotoxicity has been evaluated using erythrocytes and fibroblast cells. The toxic effects against these cells depend on the hydrophobicity of the molecules as well as their cationic charge density. The effect of hydrophobicity and cationic charge density on toxicity is different for each type of cells. For erythrocytes, the toxicity increases as hydrophobicity and charge density increases. Nevertheless, for fibroblasts cationic charge density affects cytotoxicity in the opposite way: the higher charge density, the lower the toxicity. The effect of the pH on hemolysis has been evaluated in detail. The aquatic toxicity was established using Daphnia magna. All surfactants yielded EC50 values considerably higher than that reported for cationic surfactants based on quaternary ammonium groups. Finally, their biodegradability was evaluated using the CO2 headspace test (ISO 14593). These lysine derivatives showed high levels of biodegradation under aerobic conditions and can be classified as"readily biodegradable compounds".

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Regional rates of hospitalization for ambulatory care sensitive conditions (ACSC) are used to compare the availability and quality of ambulatory care but the risk adjustment for population health status is often minimal. The objectives of the study was to examine the impact of more extensive risk adjustment on regional comparisons and to investigate the relationship between various area-level factors and the properly adjusted rates. METHODS: Our study is an observational study based on routine data of 2 million anonymous insured in 26 Swiss cantons followed over one or two years. A binomial negative regression was modeled with increasingly detailed information on health status (age and gender only, inpatient diagnoses, outpatient conditions inferred from dispensed drugs and frequency of physician visits). Hospitalizations for ACSC were identified from principal diagnoses detecting 19 conditions, with an updated list of ICD-10 diagnostic codes. Co-morbidities and surgical procedures were used as exclusion criteria to improve the specificity of the detection of potentially avoidable hospitalizations. The impact of the adjustment approaches was measured by changes in the standardized ratios calculated with and without other data besides age and gender. RESULTS: 25% of cases identified by inpatient main diagnoses were removed by applying exclusion criteria. Cantonal ACSC hospitalizations rates varied from to 1.4 to 8.9 per 1,000 insured, per year. Morbidity inferred from diagnoses and drugs dramatically increased the predictive performance, the greatest effect found for conditions linked to an ACSC. More visits were associated with fewer PAH although very high users were at greater risk and subjects who had not consulted at negligible risk. By maximizing health status adjustment, two thirds of the cantons changed their adjusted ratio by more than 10 percent. Cantonal variations remained substantial but unexplained by supply or demand. CONCLUSION: Additional adjustment for health status is required when using ACSC to monitor ambulatory care. Drug-inferred morbidities are a promising approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Position sensitive particle detectors are needed in high energy physics research. This thesis describes the development of fabrication processes and characterization techniques of silicon microstrip detectors used in the work for searching elementary particles in the European center for nuclear research, CERN. The detectors give an electrical signal along the particles trajectory after a collision in the particle accelerator. The trajectories give information about the nature of the particle in the struggle to reveal the structure of the matter and the universe. Detectors made of semiconductors have a better position resolution than conventional wire chamber detectors. Silicon semiconductor is overwhelmingly used as a detector material because of its cheapness and standard usage in integrated circuit industry. After a short spread sheet analysis of the basic building block of radiation detectors, the pn junction, the operation of a silicon radiation detector is discussed in general. The microstrip detector is then introduced and the detailed structure of a double-sided ac-coupled strip detector revealed. The fabrication aspects of strip detectors are discussedstarting from the process development and general principles ending up to the description of the double-sided ac-coupled strip detector process. Recombination and generation lifetime measurements in radiation detectors are discussed shortly. The results of electrical tests, ie. measuring the leakage currents and bias resistors, are displayed. The beam test setups and the results, the signal to noise ratio and the position accuracy, are then described. It was found out in earlier research that a heavy irradiation changes the properties of radiation detectors dramatically. A scanning electron microscope method was developed to measure the electric potential and field inside irradiated detectorsto see how a high radiation fluence changes them. The method and the most important results are discussed shortly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to examine the current situation in substance abuse treatment units in Finland in taking non-Finnish speaking clients into consideration. The initiative for this research came from the Development of Alcohol and Drugs Intervention group at Stakes (National Research and Development Centre for Welfare and Health). Their aim was to gather information about the functioning and relevance of the quality assessment forms based on the quality recommendations for substance abuse work, filled in by substance abuse treatment units. The ethnic issue was chosen as the main approach in the study. The aim of this research was to answer the following questions: what is the readiness and competence in substance abuse treatment units in Finland to receive and encounter non-Finnish speaking clients, how is the quality of these services assessed and/or developed in the units, and what has been the role and functioning of the quality recommendations and quality assessment forms in working with non-Finnish speaking clients. The research methods used in the study were both quantitative and qualitative. The information concerning language services provided in the units was gathered from the quality assessment forms and basic information forms found in the database maintained by Stakes. The total amount of units found in the database was 267. In addition to that, semi-structured theme-interviews were carried out in four substance abuse treatment units in order to get a more deep understanding of how the services function in practice. The few number of non-Finnish speaking clients in the units may explain to a certain degree the results of the research. The results however showed that there is still space for improving the services. In the light of quality recommendations, the degree of language options provided in substance abuse treatment units in Finland today is low. Also the quantity of interpreter services provided in the units is scarce. There could also be unified guidelines specially tailored for substance abuse treatment units on how to work with ethnic minorities, as the knowledge is currently adopted from several different instances. The quality recommendations as well as quality assessment forms were valued and applied in the units appropriately and were also perceived to have an effect on the functioning, and quality, in the units.