996 resultados para experimental surgery
Resumo:
OBJECT: Patients with complex craniocerebral pathophysiologies such as giant cerebral aneurysms, skull base tumors, and/or carotid artery occlusive disease are candidates for a revascularization procedure to augment or preserve cerebral blood flow. However, the brain is susceptible to ischemia, and therefore the excimer laser-assisted nonocclusive anastomosis (ELANA) technique has been developed to overcome temporary occlusion. Harvesting autologous vessels of reasonable quality, which is necessary for this technique, may at times be problematic or impossible due to the underlying systemic vascular disease. The use of artificial vessels is therefore an alternative graft for revascularization. Note, however, that it is unknown to what degree these grafts are subject to occlusion using the ELANA anastomosis technique. Therefore, the authors studied the ELANA technique in combination with an expanded polytetrafluoroethylene (ePTFE) graft. METHODS: The experimental surgeries involved bypassing the abdominal aorta in the rabbit. Ten rabbits were subjected to operations representing 20 ePTFE graft-ELANA end-to-side anastomoses. Intraoperative blood flow, followup angiograms, and long-term histological characteristics were assessed 75, 125, and 180 days postoperatively. Angiography results proved long-term patency of ePTFE grafts in all animals at all time points studied. Data from the histological analysis showed minimal intimal reaction at the anastomosis site up to 180 days postoperatively. Endothelialization of the ePTFE graft was progressive over time. CONCLUSIONS: The ELANA technique in combination with the ePTFE graft seems to have favorable attributes for end-to-side anastomoses and may be suitable for bypass procedures.
Resumo:
Recently developed computer applications provide tools for planning cranio-maxillofacial interventions based on 3-dimensional (3D) virtual models of the patient's skull obtained from computed-tomography (CT) scans. Precise knowledge of the location of the mid-facial plane is important for the assessment of deformities and for planning reconstructive procedures. In this work, a new method is presented to automatically compute the mid-facial plane on the basis of a surface model of the facial skeleton obtained from CT. The method matches homologous surface areas selected by the user on the left and right facial side using an iterative closest point optimization. The symmetry plane which best approximates this matching transformation is then computed. This new automatic method was evaluated in an experimental study. The study included experienced and inexperienced clinicians defining the symmetry plane by a selection of landmarks. This manual definition was systematically compared with the definition resulting from the new automatic method: Quality of the symmetry planes was evaluated by their ability to match homologous areas of the face. Results show that the new automatic method is reliable and leads to significantly higher accuracy than the manual method when performed by inexperienced clinicians. In addition, the method performs equally well in difficult trauma situations, where key landmarks are unreliable or absent.
Resumo:
Myocardial depression after cardiac surgery is modulated by cardiopulmonary bypass (CPB) and the underlying heart disease. The sodium pump is a key component for myocardial function. We hypothesized that the change in sodium pump expression during CPB correlates with intraoperative and postoperative laboratory and clinical parameters in neonates and children with various congenital heart defects. Sodium pump isoforms alpha1 (ATP1A1) and alpha3 (ATP1A3) mRNA expression in right atrial myocardium, excised before and after CPB, was quantified. Groups were assigned according to presence (VO group, n = 8) or absence (NO group, n = 8) of right atrial volume overload. CPB and aortic clamp time correlated with postoperative troponin-I values and ICU stay. ATP1A1 (P = 0.008) and ATP1A3 (P = 0.038) mRNA expression were significantly reduced during CPB. Longer aortic clamp times were associated with lower postoperative ATP1A1 (P = 0.045) and ATP1A3 (P = 0.002) mRNA expression. Low postoperative ATP1A1 (P = 0.043) and ATP1A3 (P = 0.002) expressions were associated with high troponin-I values. These results were restricted to the VO group. No correlation of sodium pump mRNA expression was found with the duration of ICU stay or ventilation. The postoperative troponin-I and clinical parameters correlated with the length of CPB, regardless of volume overload. In contrast, only dilated right atrium seemed to be susceptible to CPB in terms of sodium pump expression, showing a reduction during the operation and a correlation of sodium pump with postoperative troponin-I values.
Resumo:
The purpose of this study was to determine whether changes in glenoid version are associated with humeral head displacement and changes in the joint reaction forces, as these might contribute to instability or loosening in total shoulder replacement. A total shoulder prosthesis was implanted in neutral version in 6 cadaveric shoulders. Glenoid version was then changed in steps of 4 degrees toward more anteversion and retroversion. An increase in anteversion resulted in anterior translation of the humeral head and in eccentric loading of the anterior part of the glenoid. Retroversion was associated with posterior displacement and posterior loading of the glenoid. A change in rotation of the humeral component did not compensate for altered version of the glenoid component. These results suggest that both instability and glenoid component loosening may be related to the version of the glenoid component. Therefore, assessment of loosening and instability justifies precise assessment of glenoid component version.
Resumo:
PURPOSE: The objective of the present experiment was to study the morphogenesis of the mucosal attachment to implants made of c.p. titanium. MATERIAL AND METHODS: All mandibular premolars were extracted in 20 Labrador dogs. After a healing period of 3 months, four implants (ITI Dental Implant System) were placed in the right and left sides of the mandible. A non-submerged implant installation technique was used and the mucosal tissues were secured to the conical marginal portion of the implants with interrupted sutures. The sutures were removed after 2 weeks and a plaque control program including daily cleaning of the remaining teeth and the implants was initiated. The animals were sacrificed and biopsies were obtained at various intervals to provide healing periods extending from Day 0 (2 h) to 12 weeks. The mandibles were removed and placed in the fixative. The implant sites were dissected using a diamond saw and processed for histological analysis. RESULTS: Large numbers of neutrophils infiltrated and degraded the coagulum that occupied the compartment between the mucosa and the implant during the initial phase of healing. At 2 weeks after surgery, fibroblasts were the dominating cell population in the connective tissue interface but at 4 weeks the density of fibroblasts had decreased. Furthermore, the first signs of epithelial proliferation were observed in specimens representing 1-2 weeks of healing and a mature barrier epithelium occurred after 6-8 weeks of healing. The collagen fibers of the mucosa were organized after 4-6 weeks of healing. CONCLUSION: It is suggested that the soft-tissue attachment to implants placed using a non-submerged installation procedure is properly established after several weeks following surgery.
Resumo:
OBJECTIVES: Implementation of an experimental model to compare cartilage MR imaging by means of histological analyses. MATERIAL AND METHODS: MRI was obtained from 4 patients expecting total knee replacement at 1.5 and/or 3T prior surgery. The timeframe between pre-op MRI and knee replacement was within two days. Resected cartilage-bone samples were tagged with Ethi((R))-pins to reproduce the histological cutting course. Pre-operative scanning at 1.5T included following parameters for fast low angle shot (FLASH: TR/TE/FA=33ms/6ms/30 degrees , BW=110kHz, 120mmx120mm FOV, 256x256 matrix, 0.65mm slice-thickness) and double echo steady state (DESS: TR/TE/FA=23.7ms/6.9ms/40 degrees , BW=130kHz, 120x120mm FOV, 256x256 matrix, 0.65mm slice-thickness). At 3T, scan parameters were: FLASH (TR/TE/FA=12.2ms/5.1ms/10 degrees , BW=130kHz, 170x170mm FOV, 320x320, 0.5mm slice-thickness) and DESS (TR/TE/FA=15.6ms/4.5ms/25 degrees , BW=200kHz, 135mmx150mm FOV, 288x320matrix, 0.5mm slice-thickness). Imaging of the specimens was done the same day at 1.5T. MRI (Noyes) and histological (Mankin) score scales were correlated using the paired t-test. Sensitivity and specificity for the detection of different grades of cartilage degeneration were assessed. Inter-reader and intra-reader reliability was determined using Kappa analysis. RESULTS: Low correlation (sensitivity, specificity) was found for both sequences in normal to mild Mankin grades. Only moderate to severe changes were diagnosed with higher significance and specificity. The use of higher field-strengths was advantageous for both protocols with sensitivity values ranging from 13.6% to 93.3% (FLASH) and 20.5% to 96.2% (DESS). Kappa values ranged from 0.488 to 0.944. CONCLUSIONS: Correlating MR images with continuous histological slices was feasible by using three-dimensional imaging, multi-planar-reformat and marker pins. The capability of diagnosing early cartilage changes with high accuracy could not be proven for both FLASH and DESS.
Resumo:
PURPOSE: To present a novel, minimally invasive strabismus surgery (MISS) technique for inferior obliquus recessions. METHODS: Graded MISS inferior obliquus recessions were performed in 20 eyes of 15 patients by applying two small conjunctival cuts, one at the insertion of inferior obliquus and another where the scleral anchoring of the muscle occurred. RESULTS: The amount of recession was 12.2 +/- 2.3 mm (range 6 to 14 mm). The vertical deviation, which was measured in 25 degrees of adduction, decreased from preoperatively 12.8 degrees +/- 5.6 degrees to 2.7 degrees +/- 2.2 degrees (p < 0.0001) at 6 months. LogMAR visual acuity was preoperatively -0.10 +/- 0.17 and at 6 months -0.14 +/- 0.22 (p > 0.1). In one eye (2.5%) the two cuts had to be joined because of excessive bleeding. Binocular vision improved in eight patients, remained unchanged in six patients, and decreased from 30 to 60 arcsec in one patient (p > 0.1). Conjunctival and lid swelling were hardly visible on the first postoperative day in primary gaze position in 10/20 (50%) of eyes. Five of the eyes (25%) had mild and five (25%) moderate visibility of surgery. One patient out of 15 (7%) needed repeat surgery because of insufficient reduction of the sursoadduction within the first 6 months. The dose-effect relationship 6 months postoperatively for an accommodative near target at 25 degrees adduction was 0.83 degrees +/- 0.43 degrees per mm of recession. CONCLUSIONS: This study demonstrates that small-incision, minimal dissection inferior obliquus graded recessions are feasible and effective to improve ocular alignment in patients with strabismus sursoadductorius.
Resumo:
BACKGROUND: The aim of this study was to determine the rates of outpatient cataract surgery (ROCS) in ten European countries and to find country-specific health indicators explaining the differences. METHODS: Using data from the Survey of Health, Ageing and Retirement in Europe (SHARE), 251 eligible respondents were identified for which cataract surgery was the last surgical procedure. The ROCS of ten countries were compared using logistic regression. The influence of the public expenditure on health as per cent of the total expenditure on health, of the number of acute care beds per 1,000 population, and of the number of practicing physicians per 1,000 population, was studied by multiple logistic regression. Additional information was obtained from country-specific opinion leaders in the field of cataract surgery. RESULTS: The ROCS differed significantly between the ten analysed European countries where Denmark had the highest (100%) and Austria the lowest (0%) rate of day care surgery. A decrease in the density of acute care beds (p < 0.0000001) and in the density of practicing physicians (p < 0.05) and an increase in the public expenditure on health as per cent of the total health expenditure (p < 0.01) lead to an increase in the ROCS. According to the opinion leaders, regulations and financial incentives also have a strong influence on the ROCS. CONCLUSIONS: The outpatient rate of cataract surgery in the ten European countries was mainly influenced by the acute-care beds density, but also by the density of practicing physicians, and by the public expenditure on health.
Resumo:
BACKGROUND: Patients taking immunosuppressants after transplantation may require intestinal surgery. Mycophenolate mofetil (MMF) has been found to impair the healing of colonic anastomoses in rats. This study examined whether insulin-like growth factor (IGF) I prevents MMF impairment of anastomotic healing. METHODS: Sixty-three rats were divided into three groups (MMF, MMF/IGF and control). Animals underwent a sigmoid colon anastomosis with a 6/0 suture, and were killed on days 2, 4 and 6 after surgery. Investigations included bursting pressure measurement, morphometric analysis, and assessment of mucosal proliferation by 5-bromo-2'-deoxyuridine and Ki67 immunohistochemistry of the anastomoses. RESULTS: The leak rate was three of 21, one of 20 and two of 20 in the MMF, MMF/IGF-I and control groups respectively. Anastomotic bursting pressures were significantly lower in the MMF group than in the control group on days 2 and 4, but there was no significant difference by day 6. Values in the MMF/IGF-I and control groups were similar. Colonic crypt depth was significantly reduced in MMF-treated animals on days 2 and 4, but this impairment was attenuated by IGF-I on day 4. Similarly, IGF-I reduced the negative impact of MMF on mucosal proliferation on days 2 and 6. CONCLUSION: Exogenous IGF-I improves some aspects of MMF-impaired anastomotic healing.
Resumo:
Direct revascularization of a bronchial artery has been proposed as a measure to alleviate the problem of bronchial ischemia after lung transplantation. To assess the effect of restoration of arterial blood flow to the transplanted bronchus, bronchial mucosal blood flow was measured in a model of modified unilateral lung transplantation in pigs. Laser Doppler velocimetry (LDV) and radioisotope studies using radio-labeled erythrocytes (RI) were used to measure blood flow at the donor main carina (DC) and upper lobe carina (DUC) after 3 h of reperfusion. The recipient carina was used as a reference point; values obtained by LDV and RI were expressed as percentage of blood flow at the recipient carina. Two groups of animals were studied. In group 1 (n = 6) standard unilateral transplantation was performed; in group 2 (n = 6) a left bronchial artery was reimplanted into the descending thoracic aorta of the recipient. No differences were observed between the two groups with respect to preoperative or postoperative gas exchange or hemodynamics. In group 1, bronchial blood flow at the DC was 37.6 +/- 2.2% (LDV) and 44.1 +/- 14.8% (RI) of reference blood flow. At the DUC, blood flow was 54.9 +/- 7.7% (LDV) and 61.6 +/- 25.7% (RI) of normal flow. In group 2, blood flow was increased at the DC as measured by LDV (55.3 +/- 17.1%; p less than 0.05) and by RI (60.8 +/- 25.3%; p less than 0.2). A similar increase was found at the DUC (LDV: 81.8 +/- 19.3%; p less than 0.05; RI: 88.6 +/- 31.0%; p less than 0.2). It is concluded that there is a significant gradient of blood flow from intra- to extrapulmonary airways after lung transplantation. Reimplantation of a bronchial artery results in significant improvement of graft bronchial blood flow. Restoration of bronchial perfusion to normal levels, however, cannot be achieved, suggesting a possible defect in the microcirculation of the donor airways.
Resumo:
BACKGROUND: Bleeding is a frequent complication during surgery. The intraoperative administration of blood products, including packed red blood cells, platelets and fresh frozen plasma (FFP), is often live saving. Complications of blood transfusions contribute considerably to perioperative costs and blood product resources are limited. Consequently, strategies to optimize the decision to transfuse are needed. Bleeding during surgery is a dynamic process and may result in major blood loss and coagulopathy due to dilution and consumption. The indication for transfusion should be based on reliable coagulation studies. While hemoglobin levels and platelet counts are available within 15 minutes, standard coagulation studies require one hour. Therefore, the decision to administer FFP has to be made in the absence of any data. Point of care testing of prothrombin time ensures that one major parameter of coagulation is available in the operation theatre within minutes. It is fast, easy to perform, inexpensive and may enable physicians to rationally determine the need for FFP. METHODS/DESIGN: The objective of the POC-OP trial is to determine the effectiveness of point of care prothrombin time testing to reduce the administration of FFP. It is a patient and assessor blind, single center randomized controlled parallel group trial in 220 patients aged between 18 and 90 years undergoing major surgery (any type, except cardiac surgery and liver transplantation) with an estimated blood loss during surgery exceeding 20% of the calculated total blood volume or a requirement of FFP according to the judgment of the physicians in charge. Patients are randomized to usual care plus point of care prothrombin time testing or usual care alone without point of care testing. The primary outcome is the relative risk to receive any FFP perioperatively. The inclusion of 110 patients per group will yield more than 80% power to detect a clinically relevant relative risk of 0.60 to receive FFP of the experimental as compared with the control group. DISCUSSION: Point of care prothrombin time testing in the operation theatre may reduce the administration of FFP considerably, which in turn may decrease costs and complications usually associated with the administration of blood products. TRIAL REGISTRATION: NCT00656396.
Resumo:
HYPOTHESIS: Chronic rotator cuff tears are associated with irreversible architectural muscle changes and a high rate of repair failure. The changes observed in man and their irreversibility with a single stage repair can be reproduced in sheep. It was the purpose of this experiment to test the hypothesis that slow, continuous elongation of a retracted musculotendinous unit allows reversal of the currently irreversible structural muscle changes. MATERIALS AND METHODS: The infraspinatus tendon of 12 sheep was released using a greater tuberosity osteotomy and allowed to retract for 4 months. Then, a new device was mounted on the scapular spine and used to extend the infraspinatus muscuculotendinous unit transcutaneously by 1 mm per day. Thereafter, the tendon was repaired back to the greater tuberosity. We assessed the muscular architecture using magnetic resonance imaging, macroscopic dissection, histology, and electron microscopy. Fatty infiltration (in Hounsfield units 1/4 HU) and muscular cross-sectional area (in % of the control side) were monitored with computed tomography at tendon release, initiation of elongation, repair, and at sacrifice. RESULTS: Sixteen weeks after tendon release, the mean tendon retraction was 29 +/- 6 mm (14% of original length, P = .008). In 8 sheep, elongation was achieved as planned (group I), but in 4, the elongation failed technically (group II). The mean traction time was 24 +/- 6 days with a mean traction distance of 19 +/- 4 mm. At sacrifice, the mean pennation angle in the infraspinatus of group I was not different from the control side (29.8 degrees +/-7.5 degrees vs. 30 degrees +/-6 degrees , P = .575). In group II, the pennation angle had increased from 30 degrees +/-6 degrees to 55 degrees +/-14 degrees (P = .035). There was no fatty infiltration at the time of tendon release. After retraction, there was a significant increase in fatty infiltration of the infraspinatus muscle and a decrease of its cross-sectional area to 57% of the contralateral side (P = .0001). During traction, the degree of fatty infiltration remained unchanged (36 HU to 38 HU, P = .381), and atrophy improved to a muscle square area of 78% of the contralateral side (P = .0001) in group I. In group II, an increase of fatty infiltration was measured from 36 HU to 28 HU; however, this increase was not significant (P = .144). Atrophy did not change in group II (57-55%, P = .946). At sacrifice, the remaining muscle mass was 64% in group I and 46% in group II (P = .019). DISCUSSION: Our preliminary results document, that continuous elongation of a retracted, fatty infiltrated and atrophied musculotendinous unit is technically feasible. CONCLUSION: In the sheep, continuous elongation can lead to restoration of normal muscle architecture, to partial reversal of muscle atrophy, and to arrest of the progression of fatty infiltration. LEVEL OF EVIDENCE: Basic science level 2; Prospective comparative therapeutic study.
Resumo:
The planning of refractive surgical interventions is a challenging task. Numerical modeling has been proposed as a solution to support surgical intervention and predict the visual acuity, but validation on patient specific intervention is missing. The purpose of this study was to validate the numerical predictions of the post-operative corneal topography induced by the incisions required for cataract surgery. The corneal topography of 13 patients was assessed preoperatively and postoperatively (1-day and 30-day follow-up) with a Pentacam tomography device. The preoperatively acquired geometric corneal topography – anterior, posterior and pachymetry data – was used to build patient-specific finite element models. For each patient, the effects of the cataract incisions were simulated numerically and the resulting corneal surfaces were compared to the clinical postoperative measurements at one day and at 30-days follow up. Results showed that the model was able to reproduce experimental measurements with an error on the surgically induced sphere of 0.38D one day postoperatively and 0.19D 30 days postoperatively. The standard deviation of the surgically induced cylinder was 0.54D at the first postoperative day and 0.38D 30 days postoperatively. The prediction errors in surface elevation and curvature were below the topography measurement device accuracy of ±5μm and ±0.25D after the 30-day follow-up. The results showed that finite element simulations of corneal biomechanics are able to predict post cataract surgery within topography measurement device accuracy. We can conclude that the numerical simulation can become a valuable tool to plan corneal incisions in cataract surgery and other ophthalmosurgical procedures in order to optimize patients' refractive outcome and visual function.