974 resultados para exhaust heat recovery


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A wet scrubber is a device used in underground coal mines for the exhaust treatment system of various internal combustion engines (generally diesel) primarily as a spark arrestor with a secondary function to remove pollutants from the exhaust gas. A pool of scrubbing liquid (generally water based) is used in conjunction with a Diesel Particulate Filter (DPF). Scrubbers are widely used in underground applications of diesel engines as their exhaust contains high concentration of harmful diesel particulate matter (DPM) and other pollutant gases. Currently the DPFs have to be replaced frequently because moisture output from the wet scrubber blocks the filter media and causes reduced capacity. This paper presents experimental and theoretical studies on the heat and mass transfer mechanisms of the exhaust flow both under and above the water surface, aiming at finding the cause and effects of the moisture reaching the filters and employing a solution to reduce the humidity and DPM output, and to prolong the change-out period of the DPF. By assuming a steady flow condition, heat transfer from the inlet exhaust gas balances energy required for the water evaporation. Hence the exit humidity will decrease with the increase of exit temperature. Experiments on a real scrubber are underway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To review the existing research on the effectiveness of heat warning systems (HWSs) in saving lives and reducing harm. Methods A systematic search of major databases was conducted, using “heat, heatwave, high temperature, hot temperature, OR hot climate” AND “warning system”. Results Fifteen articles were retrieved. Six studies asserted that fewer people died of excessive heat after HWS implementation. HWS was associated with reduction in ambulance use. One study estimated the benefits of HWS to be 468millionforsaving117livescomparedto210,000 costs of running the system. Eight studies showed that mere availability of HWS did not lead to behavioral changes. Perceived threat of heat dangers to self/others was the main factor related to heeding warnings and taking proper actions. However, costs and barriers associated with taking protective actions, such as costs of running air conditioners, were of significant concern particularly to the poor. Conclusions Research in this area is limited. Prospective designs applying health behavior theories should establish whether HWS can produce the health benefits they are purported to achieve by identifying the target vulnerable groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heatwaves are associated with significant health risks particularly among vulnerable groups. To minimize these risks, heat warning systems have been implemented. The question therefore is how effective these systems are in saving lives and reducing heat-related harm. We systematically searched and reviewed 15 studies which examined this. Six studies asserted that fewer people died of excessive heat after the implementation of heat warning systems. Demand for ambulance decreased following the implementation of these systems. One study also estimated the costs of running heat warning systems at US$210,000 compared to the US$468 million benefits of saving 117 lives. The remaining eight studies investigated people?s response to heat warning systems and taking appropriate actions against heat harms. Perceived threat of heat dangers emerged as the main factor related to heeding the warnings and taking proper actions. However, barriers, such as costs of running air-conditioners, were of significant concern, particularly to the poor. The weight of the evidence suggests that heat warning systems are effective in reducing mortality and, potentially, morbidity. However, their effectiveness may be mediated by cognitive, emotive and socio-demographic characteristics. More research is urgently required into the cost-effectiveness of heat warning systems? measures and improving the utilization of the services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the propensity of fleet incidents, poor organisational survey results and a lack of fleet safety systems, it was evident that Redland City Council were underperforming, experiencing a variety of work related road safety issues and possessed a low fleet safety culture. As a result of an audit process, and the identification of gaps in organisational process within the fleet safety area Redland City Council embarked upon the enormous task of strategically implementing initiatives and improving fleet safety across the organisation. The strategies utilised within the Redland City Council Fleet Safety Initiative were implemented utilising a systematic process and adopted a multi-disciplinary approach to improve overall fleet safety. Organisational initiatives targeting fleet safety aspects have benefited the Council by the development of an improved organisational culture, including safer driver attitudes and behaviour. This paper outlines the road to recovery for Redland City Council in relation to its fleet safety initiatives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the time course of the recovery of transverse strain in the Achilles and patellar tendon following a bout of resistance exercise. Methods Seventeen healthy adults underwent sonographic examination of the right patellar (n=9) and Achilles (n=8) tendons immediately prior to and following 90 repetitions of weight-bearing quadriceps and gastrocnemius-resistance exercise performed against an effective resistance of 175% and 250% body weight, respectively. Sagittal tendon thickness was determined 20 mm from the enthesis and transverse strain, as defined by the stretch ratio, was repeatedly monitored over a 24 h recovery period. Results Resistance exercise resulted in an immediate decrease in Achilles (t7=10.6, p<0.01) and patellar (t8=8.9, p<0.01) tendon thickness, resulting in an average transverse stretch ratio of 0.86±0.04 and 0.82±0.05, which was not significantly different between tendons. The magnitude of the immediate transverse strain response, however, was reduced with advancing age (r=0.63, p<0.01). Recovery in transverse strain was prolonged compared with the duration of loading and exponential in nature. The average primary recovery time was not significantly different between the Achilles (6.5±3.2 h) and patellar (7.1±3.2 h) tendons. Body weight accounted for 62% and 64% of the variation in recovery time, respectively. Conclusions Despite structural and biochemical differences between the Achilles and patellar tendon, the mechanisms underlying transverse creep recovery in vivo appear similar and are highly time dependent. These novel findings have important implications concerning the time required for the mechanical recovery of high-stress tendons following an acute bout of exercise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dual-scale model of the torrefaction of wood was developed and used to study industrial configurations. At the local scale, the computational code solves the coupled heat and mass transfer and the thermal degradation mechanisms of the wood components. At the global scale, the two-way coupling between the boards and the stack channels is treated as an integral component of the process. This model is used to investigate the effect of the stack configuration on the heat treatment of the boards. The simulations highlight that the exothermic reactions occurring in each single board can be accumulated along the stack. This phenomenon may result in a dramatic eterogeneity of the process and poses a serious risk of thermal runaway, which is often observed in industrial plants. The model is used to explain how thermal runaway can be lowered by increasing the airflow velocity, the sticker thickness or by gas flow reversal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ramp metering is an effective motorway control tool beneficial for mainline traffic, but the long on-ramp queues created interfere with surface traffic profoundly. This study deals with the conflict between mainline benefits and thecosts of on-ramp and surface traffic. A novel local on-ramp queue management strategy with mainline speed recovery is proposed. Microscopic simulation is used to test the new strategy and compare it with other strategies. Simulation results reveal that the ramp metering with queue management strategy provides a good balance between the mainline and on-ramp performances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nonthermal plasma (NTP) treatment of exhaust gas is a promising technology for both nitrogen oxides (NOX) and particulate matter (PM) reduction by introducing plasma into the exhaust gases. This paper considers the effect of NTP on PM mass reduction, PM size distribution, and PM removal efficiency. The experiments are performed on real exhaust gases from a diesel engine. The NTP is generated by applying high-voltage pulses using a pulsed power supply across a dielectric barrier discharge (DBD) reactor. The effects of the applied high-voltage pulses up to 19.44 kVpp with repetition rate of 10 kHz are investigated. In this paper, it is shown that the PM removal and PM size distribution need to be considered both together, as it is possible to achieve high PM removal efficiency with undesirable increase in the number of small particles. Regarding these two important factors, in this paper, 17 kVpp voltage level is determined to be an optimum point for the given configuration. Moreover, particles deposition on the surface of the DBD reactor is found to be a significant phenomenon, which should be considered in all plasma PM removal tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Climate change is leading to an increased frequency and severity of heat waves. Spells of several consecutive days of unusually high temperatures have led to increased mortality rates for the more vulnerable in the community. The problem is compounded by the escalating energy costs and increasing peak electrical demand as people become more reliant on air conditioning. Domestic air conditioning is the primary determinant of peak power demand which has been a major driver of higher electricity costs. This report presents the findings of multidisciplinary research which develops a national framework to evaluate the potential impacts of heat waves. It presents a technical, social and economic approach to adapt Australian residential buildings to ameliorate the impact of heat waves in the community and reduce the risk of its adverse outcomes. Through the development of a methodology for estimating the impact of global warming on key weather parameters in 2030 and 2050, it is possible to re-evaluate the size and anticipated energy consumption of air conditioners in future years for various climate zones in Australia. Over the coming decades it is likely that mainland Australia will require more cooling than heating. While in some parts the total electricity usage for heating and cooling may remain unchanged, there is an overall significant increase in peak electricity demand, likely to further drive electricity prices. Through monitoring groups of households in South Australia, New South Wales and Queensland, the impact of heat waves on both thermal comfort sensation and energy consumption for air conditioning has been evaluated. The results show that households are likely to be able to tolerate slightly increased temperature levels indoors during periods of high outside temperatures. The research identified that household electricity costs are likely to rise above what is currently projected due to the impact of climate change. Through a number of regulatory changes to both household design and air conditioners, this impact can be minimised. A number of proposed retrofit and design measures are provided, which can readily reduce electricity usage for cooling at minimal cost to the household. Using a number of social research instruments, it is evident that households are willing to change behaviour rather than to spend money. Those on lower income and elderly individuals are the least able to afford the use of air conditioning and should be a priority for interventions and assistance. Increasing community awareness of cost effective strategies to manage comfort and health during heat waves is a high priority recommended action. Overall, the research showed that a combined approach including behaviour change, dwelling modification and improved air conditioner selection can readily adapt Australian households to the impact of heat waves, reducing the risk of heat related deaths and household energy costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a practical prediction procedure for vertical displacement of a Rotarywing Unmanned Aerial Vehicle (RUAV) landing deck in the presence of stochastic sea state disturbances. A proper time series model tending to capture characteristics of the dynamic relationship between an observer and a landing deck is constructed, with model orders determined by a novel principle based on Bayes Information Criterion (BIC) and coefficients identified using the Forgetting Factor Recursive Least Square (FFRLS) method. In addition, a fast-converging online multi-step predictor is developed, which can be implemented more rapidly than the Auto-Regressive (AR) predictor as it requires less memory allocations when updating coefficients. Simulation results demonstrate that the proposed prediction approach exhibits satisfactory prediction performance, making it suitable for integration into ship-helicopter approach and landing guidance systems in consideration of computational capacity of the flight computer.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heat islands are a significant problem in urban spaces worldwide. The phenomenon occurs when air and surface temperatures in urban areas significantly exceed those experienced in nearby rural areas. There are two main causes of heat islands. The first is the use of highly absorptive construction materials in buildings and infrastructure, which soak up heat and radiate it back into the immediate surroundings. These materials, including but not limited to concrete, steel, asphalt and stone, are usually impermeable and so do not embody moisture that could dissipate some of the absorbed heat. The second cause relates to urban form, where the canyon-like configurations of buildings and streets channel and trap heat from the sun. In both cases, an absence of greenery and other soft landscaping can compound the problem by lowering capacity for cooling through shading and evotranspiration. Incidences of heat islands increase as urban areas swell in size and cover more land area, making the phenomenon an unwelcome side effect of global trends towards increased urbanisation. Heat islands create serious problems, including increased energy demand for cooling, declining air quality and heat stress for people and animals. In very severe cases, heat islands can compound the effects of high urban temperatures, leading to increased human mortality...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Generally, the magnitude of pollutant emissions from diesel engines is ultimately coupled to the structure of fuel molecules. The presence of oxygen, level of unsaturation and the carbon chain length of respective molecules influence the combustion chemistry. It is speculated that increased oxygen content in the fuel may lead to the increased oxidative potential (Stevanovic, S. 2013). Also, upon the exposure to UV and ozone in the atmosphere, the chemical composition of the exhaust is changed. The presence of an oxidant and UV is triggering the cascade of photochemical reactions as well as the partitioning of semi-volatile compounds between the gas and particle phase. To gain an insight into the relationship between the molecular structures of the esters, their volatile organic content and the potential toxicity of diesel exhaust particulate matter, measurements were conducted on a modern common rail diesel engine. This research also investigates the contribution of atmospheric conditions on the transfer of semi-volatile fraction of diesel exhaust from the gas phase to the particle phase and the extent to which semi-volatile compounds (SVOCs) are related to the oxidative potential, expressed through the concentration of reactive oxygen species (ROS) (Stevanovic, S. 2013)...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A numerical investigation has been carried out for the coupled thermal boundary layers on both sides of a partition placed in an isosceles triangular enclosure along its middle symmetric line. The working fluid is considered as air which is initially quiescent. A sudden temperature difference between two zones of the enclosure has been imposed to trigger the natural convection. It is anticipated from the numerical simulations that the coupled thermal boundary layers development adjacent to the partition undergoes three distinct stages; namely an initial stage, a transitional stage and a steady state stage. Time dependent features of the coupled thermal boundary layers as well as the overall natural convection flow in the partitioned enclosure have been discussed and compared with the non-partitioned enclosure. Moreover, heat transfer as a form of local and overall average Nusselt number through the coupled thermal boundary layers and the inclined walls is also examined.