968 resultados para endoscopic ultrasound
Resumo:
Purpose: Tumour-free resection margins (RMs) are mandatory in breast-conserving surgery. On-site intraoperative ultrasound (US)-guided tumour resection with extemporaneous histopathological assessment of RMs has been described. Remote intraoperative US assessment of RMs is an alternative. The purpose of this study was to evaluate the relationship of lumpectomy RMs measurements between remote intraoperative US and postoperative histopathology.Methods and Materials: In a retrospective IRB-approved review of 100 consecutive lumpectomies performed between October 2009 and April 2011 for presumed non-palpable breast cancer, 71 women (mean age 63.8years) were included. Twenty-nine patients were excluded because of absence of cancer at histopathology and/or incomplete data. Measurements of lumpectomy minimal RMs and tumour maximal diameter obtained on remote intraoperative US and postoperative histopathology were compared.Results: Minimal RMs were 0.35±0.32 (mean±SD) and 0.35±0.32cm on remote intraoperative US and postoperative histopathology, respectively. No significant difference was found between these measurements (p=0.37). Tumour maximal diameter was 1.02±0.51 (mean±SD) and 1.33±0.74cm on remote intraoperative US and postoperative histopathology, respectively. US measurements were significantly smaller (p<0.001). The 71 breast carcinoma (CA) consisted of: invasive canalar (n=49), invasive lobular (n=11), in situ (n=3) and other types of CA (n=8). Twenty-nine patients had intraoperative re-excision (24 without residual CA), while 16 patients were re-operated due to insufficient histopathological RMs (12 without residual CA).Conclusion: Good correlation of minimal RMs between remote intraoperative US and postoperative histopathology warrants use of both techniques in a complementary manner. Remote intraoperative US is helpful in taking rapid decision of re-excision and maintaining low re-operation rate after breast-conserving surgery for non-palpable cancer.
Resumo:
RÉSUME Les techniques de résection muqueuse endoscopique utilisées actuellement ne permettent pas d'effectuer une résection circonférentielle d'un long segment de muqueuse oesophagienne. Une telle résection permettrait le traitement de foyers multicentriques de dysplasies de haut grade (HGIN) ou d'adénocarcinomes précoces (AC) développés sur oesophage de Barrett. Sachant que la prévalence des métastases ganglionnaires régionales est d'environ 7 % pour les adénocarcinomes intra-muqueux (Tis,T1a), les méthodes de traitement non-chirurgicales et moins invasives sont actuellement préférées à une oesophagectomie, dont la morbidité et la mortalité restent élevées en comparaison avec les mucosectomies endoscopiques. Un oesophagoscope rigide modifié a été développé à Lausanne en collaboration avec la maison Karl Storz GmbH, de façon à permettre des résections muqueuses étendues dans l'oesophage. Cette étude animale pilote a investigué la faisabilité et la fiabilité des résections muqueuses circonférentielles de différentes longueurs dans l'oesophage du mouton. Des résections circonférentielles de 2,2 cm (n=6), 3,3 cm (n=6), 4,4 cm (n=7) et 5,5 cm (n=5) de longueur ont été effectuées dans l'oesophage de 24 moutons. Elles consistaient en 2 mucosectomies hémi-circonférentielles opposées. Les animaux ont été suivis par des examens endoscopiques à une semaine puis chaque mois pendant 6 mois ou jusqu'à réépithélialisation complète sans sténose. Au cours du processus de guérison, les sténoses cicatricielles ont été traitées par une ou plusieurs dilatations avec les bougies de Savary. Des résections circonférentielles de 2,2 à 5,5 cm de longueur ont été réalisées avec succès dans 23/24 des cas. Une seule perforation, secondaire à une erreur de manipulation, est survenue directement après la mucosectomie. A l'analyse histologique, une profondeur de résection précise à travers la sousmuq Tyrp1ueuse a été obtenue dans 85% des specimens. Les sténoses cicatricielles ont été contrôlées dans 95% des cas par dilatations avec les bougies de Savary. L'oesophagoscope rigide modifié a permis de réaliser des résections muqueuses circonférentielles et étendues en une seule séance endoscopique d'une durée de moins d'une demi-heure. L'utilisation de ce résectoscope chez l'homme devrait permettre l'éradication complète de l'oesophage de Barrett avec HGIN et/ou AC précoce dans un avenir très proche.
Resumo:
The purpose was to evaluate the influence of radiologist's experience on the diagnostic yield and complications of a percutaneous liver biopsy (PLB) method. Six hundred patients underwent an ultrasound-guided PLB by an inexperienced operator in 25.2% of cases (experience of less than 15 percutaneous liver biopsies performed alone--group I) or by an experienced operator (experience of more than 150 percutaneous liver biopsies--group II). The two groups were well-matched with respect to sex, age, percentage with viral hepatitis without histological cirrhosis, number of needle passes, history of liver biopsy and pain before the biopsy. A histological diagnosis was available in 97.3% of cases without any significant difference between the two groups ( P=0.25). However, group II samples were significantly longer and contained more portal tracts ( P=0.01). Pain was mild immediately and 6 h after the biopsy, without significant difference between both groups. Eight vasovagal reactions (five in group II) and one arteriobiliary fistula (in group II) occurred. With the method of PLB used for this study, operator's experience did not influence either the final histological diagnosis or the degree of pain suffered.
Resumo:
BACKGROUND: During the past decades, endoscopic mucosal resection (EMR) has been developed to treat early intramucosal esophageal cancers and dysplastic Barrett's esophagus. The primary drawback of this method is severe postsurgical esophageal stricture formation. The purpose of this preclinical study was to assess strategies for prevention of this major complication by injecting autologous keratinocytes in the EMR mucosal defect in the sheep model. METHODS: Circumferential, 6-cm-long EMRs were performed in the esophagus of nine sheep. Autologous keratinocytes were harvested 2 weeks before EMR and cultured. Circumferential resection consisted of two opposite hemicircumferential mucosectomies allowing a widespread resection of 24 cm(2). Immediately after EMR, autologous keratinocytes were endoscopically injected in the mucosal defect. Animals were sacrificed after 6 months. RESULTS: Circumferential EMRs were successfully performed in all animals. There were no intra- or postoperative complications. None of the animals developed strictures. All animals were sacrificed at 6 months as planned. Histological examinations showed fibrotic changes in 10 % (range 0-25 %) of the circumferential muscularis propria interna layer and 7.2 % (range 0-25 %) in the muscularis propria externa layer at the midportion of the EMR. No circumferential transmural fibrosis was identified. CONCLUSIONS: Prevention of stricture formation after extensive (6-cm long) circumferential EMR of the sheep esophagus can be achieved by injecting autologous keratinocytes into the wound of the resected mucosal segment.
Resumo:
Objective: The treatment of choice in end-stage renal disease is¦transplantation.¦Hemodynamic disturbances can evoke graft loss, while early ultrasound¦identification of vascular problems improves outcome. The primary endpoint¦of this study was to identify differences in post-op complications with and¦without systematic, intraoperative Doppler ultrasound use. A secondary aim¦was to find a predictive resistance index limit which would show where surgical¦reintervention was necessary.¦Methods: Between Jan 2000 and Dec 2010, 108 renal transplants were¦performed from living donors at our institution. In group 1 (n = 67),¦intra-operative duplex ultrasound and intra-parenchymatous resistance index¦measurements assessed patients, while in group 2 (n = 41), no ultrasound was¦performed.¦Results. There were no inter-group differences in the overall post-op¦complication rate or in benefit to graft or patient survival with Doppler use,¦however, significantly more vascular complications (10% vs. 0%, p = 0·02) and¦more acute rejections (37% vs. 10%) occurred in group 2 than in group 1,¦respectively. When the resistance index was <0·5 intra-operatively, immediate¦surgical revision was undertaken to raise the index >0·6.¦Results: There were no inter-group differences in the overall post-op¦complication rate or in benefit to graft or patient survival with Doppler use,¦however, significantly more vascular complications (10% vs. 0%, p = 0·02) and¦more acute rejections (37% vs. 10%) occurred in group 2 than in group 1,¦respectively. When the resistance index was <0·5 intra-operatively, immediate¦surgical revision was undertaken to raise the index >0·6.¦Conclusion: This is the first report demonstrating benefits of systematic¦intraoperative Doppler ultrasound on post-operative complications in renal¦transplantation from living donors. Our results support surgical revision with a¦resistance index <0·5.
Endoscopic extraction of a prevertebral migrated guidewire after posterior cervical instrumentation.
Resumo:
Images of Spine Care
Resumo:
The clinical data of 180 episodes of upper gastrointestinal bleeding in 168 patients with cirrhosis of the liver are examined. The source of bleeding had been determined by early endoscopy in all cases. In men under the age of 50 years, and without symptoms of liver failure, bleeding was due to ruptured gastro-oesophageal varices in 84% of cases. Severe liver failure was associated with acute lesions of gastric mucosa in many cases. No presumptive diagnosis of the source of haemorrhage could be based on the examination of other clinical data (presence of ascites, mode of presentation and pattern of bleeding, history of ulcer disease, alcoholism, and previous medication.
Resumo:
Patients with stenosed biologic pulmonary conduits require redo cardiac surgery to prevent severe right ventricular dysfunction. Following the latest trends, the trans-catheter pulmonary stent-valve implantation represents a new fascinating alternative carrying a lower operative risk, compared with the standard open-heart re-intervention. Traditionally, the pulmonary stent valve is positioned off pump, under fluoroscopic control, and requires angiographies. However, alternative tools not requiring contrast injections for the intra-operative cardiac imaging have to be also considered strongly. The usefulness of intravascular ultrasound for the positioning of aortic endoprosthesis has already been proven in previous reports and, following the same principle, we have started to routinely implant balloon-expandable stent valves (Edwards Sapien? THV) in stenosed pulmonary valve conduits using intravascular ultrasound for the stent-valve positioning without angiography. We describe the intra-operative intravascular imaging technique with technical details.
Resumo:
The clinical data of 180 episodes of upper gastrointestinal bleeding in 168 patients with cirrhosis of the liver are examined. The source of bleeding had been determined by early endoscopy in all cases. In men under the age of 50 years, and without symptoms of liver failure, bleeding was due to ruptured gastro-oesophageal varices in 84% of cases. Severe liver failure was associated with acute lesions of gastric mucosa in many cases. No presumptive diagnosis of the source of haemorrhage could be based on the examination of other clinical data (presence of ascites, mode of presentation and pattern of bleeding, history of ulcer disease, alcoholism, and previous medication.
Resumo:
PRINCIPLES: This retrospective study analyzes the long-term results of endoscopic and surgical treatment of vesico-ureteral reflux in children. METHODS: A cohort of 130 patients, 67 girls and 63 boys with a mean age of 30 months were treated either by endoscopic subureteral collagen injection (SCIN) in 92 and by Cohen reimplantation surgery in 123 refluxing ureteral units. Mean follow-up was 4.2 years varying from 1 to 8.7 years. Reflux recurrence, urinary tract infection (UTI) and renal function were evaluated. RESULTS: After SCIN reflux was absent in 64% at 6 months. 20% of the initially 92 refluxing ureters were injected twice. After one or two injections reflux was absent in 71%. In 21% recurrent reflux was of grade I or II, not requiring further treatment. UTI was observed in 27%. After Cohen ureteral reimplantation reflux was absent in 96% at 6 months. UTI was observed in 23%. Renal function at diagnosis and follow-up was compared in children with bilateral grade III reflux only. In patients treated with SCIN it was normal in 77% preoperatively and in 90% at follow-up. In patients treated by open surgery it was normal in 47% preoperatively and in 76% at follow-up. CONCLUSION: For high-grade vesico-ureteral reflux re-implantation surgery remains the gold standard. SCIN is indicated for low and medium grade reflux. Recurrent bacteriuria was observed more often after SCIN and pyelonephritis more often after open surgery. The renal function seems to be preserved with both techniques.
Resumo:
BACKGROUND: Since the introduction of the endoscopic endonasal approaches in the field of skull base surgery during the last two decades, several variants of the sella turcica endoscopic surgery have been described. The aim of this study is to provide a stepwise description of one of these variants in a minimally invasive/maximally efficient perspective. METHOD: For the majority of our sella turcica pathologies, we have progressively adopted a uninostril endoscopic approach that is very conservative towards the nasal mucosa with a very limited mucosal incision, resection of the vomer and allowing an almost ad integrum sellar floor reconstruction, without compromising the efficacy and completeness of both surgical oncologic and endocrine targets. CONCLUSION: The uninostril trans-sphenoidal endoscopic endonasal approach to sella turcica is tailored to ally maximal efficiency and minimal invasiveness.
Resumo:
The purpose of this study was to evaluate and compare the benefits of endoscopic saphenous vein harvesting (EVH) with the traditional incision technique (TIT) for coronary artery bypass grafting (CABG) in respect to the technical procedure and clinical outcome. In a prospective nonrandomized, case-matched study the greater saphenous vein was harvested for CABG in 22 patients using the endoscopic technique and in 18 patients with the traditional method. Comparisons were made for the operating time, length of incision and vein harvested, graft quality, postoperative complications, and pain assessment. Patient demographics were well matched. EVH required smaller incisions than did the TIT (10.5 +/- 6.6 vs. 31.2 +/- 7.8 cm, respectively; p < 0.0001). Harvest time and vein quality were comparable in the two groups. Total vein operating time was shorter following the endoscopic technique (60 +/- 24 vs. 100 +/- 35 minutes, respectively; p < 0.0001). EVH had fewer complications (NS), and postoperative pain was significantly less (p = 0.0034). The major advantages of endoscopic vein harvesting are a significant reduction of postoperative pain and strikingly better cosmetic results. Wound complications seem to be less frequent.
Resumo:
Five years of experience with endovascular infrarenal aneurysm repair at our institution is reviewed. Implantation of endoprostheses in 88 patients has been performed by surgeons using exclusively intravascular ultrasound (IVUS) and fluoroscopy. IVUS identified the target site of deployment in all cases. In-hospital morbidity was 22% (19/88). Two percent mortality (2/88) and 5% early conversion (4/88) as a consequence of type I endoleaks were noted only in the first 53 patients with early devices (NS). Early endoleaks were present in 36% (32/88) including twenty-two type I, five type II and five type III endoleaks. Proximal endoleaks were associated with early devices (P<0.001), and technical difficulties with deployment. Tube grafts used in the beginning, performed poorly with 54% (7/13) type I endoleaks. Endoleaks diminished to 10% (9/88) by spontaneous closure and secondary endovascular procedures that were necessary in 24% (21/88) and consisted of coil embolization/cuff extension (9), late conversion (6), and limb recanalization or femoral cross-over bypass (6). Endovascular aneurysm repair using IVUS is a valid alternative technique. Improved devices and systematic use of bifurcated endoprostheses for infrarenal aneurysms reduce the occurrence of type I endoleaks.