887 resultados para compression set


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this note we introduce the Lorenz stable set and provide an axiomatic characterization in terms of constrained egalitarianism and projection consistency. On the domain of all coalitional games, we find that this solution connects the weak constrained egalitarian solution (Dutta and Ray, 1989) with their strong counterpart (Dutta and Ray, 1991)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper aims to examine changes in common longevity and variability of the adult life span, and attempts to answer whether or not the compression of mortality continues in Switzerland in the years 1876-2005. The results show that the negative relationships between the large increase in the adult modal age at death, observed at least from the 1920s, and the decrease in the standard deviation of the ages at deaths occurring above it, illustrate a significant compression of adult mortality. Typical adult longevity increased by about 10% during the last fifty years in Switzerland, and adult heterogeneity in the age at death decreased in the same proportion. This analysis has not found any evidence suggesting that we are approaching longevity limits in term of modal or even maximum life spans. It ascertains a slowdown in the reduction of adult heterogeneity in longevity, already observed in Japan and other low mortality countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we propose a method for computing JPEG quantization matrices for a given mean square error or PSNR. Then, we employ our method to compute JPEG standard progressive operation mode definition scripts using a quantization approach. Therefore, it is no longer necessary to use a trial and error procedure to obtain a desired PSNR and/or definition script, reducing cost. Firstly, we establish a relationship between a Laplacian source and its uniform quantization error. We apply this model to the coefficients obtained in the discrete cosine transform stage of the JPEG standard. Then, an image may be compressed using the JPEG standard under a global MSE (or PSNR) constraint and a set of local constraints determined by the JPEG standard and visual criteria. Secondly, we study the JPEG standard progressive operation mode from a quantization based approach. A relationship between the measured image quality at a given stage of the coding process and a quantization matrix is found. Thus, the definition script construction problem can be reduced to a quantization problem. Simulations show that our method generates better quantization matrices than the classical method based on scaling the JPEG default quantization matrix. The estimation of PSNR has usually an error smaller than 1 dB. This figure decreases for high PSNR values. Definition scripts may be generated avoiding an excessive number of stages and removing small stages that do not contribute during the decoding process with a noticeable image quality improvement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes an audio watermarking scheme based on lossy compression. The main idea is taken from an image watermarking approach where the JPEG compression algorithm is used to determine where and how the mark should be placed. Similarly, in the audio scheme suggested in this paper, an MPEG 1 Layer 3 algorithm is chosen for compression to determine the position of the mark bits and, thus, the psychoacoustic masking of the MPEG 1 Layer 3compression is implicitly used. This methodology provides with a high robustness degree against compression attacks. The suggested scheme is also shown to succeed against most of the StirMark benchmark attacks for audio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, an advanced technique for the generation of deformation maps using synthetic aperture radar (SAR) data is presented. The algorithm estimates the linear and nonlinear components of the displacement, the error of the digital elevation model (DEM) used to cancel the topographic terms, and the atmospheric artifacts from a reduced set of low spatial resolution interferograms. The pixel candidates are selected from those presenting a good coherence level in the whole set of interferograms and the resulting nonuniform mesh tessellated with the Delauney triangulation to establish connections among them. The linear component of movement and DEM error are estimated adjusting a linear model to the data only on the connections. Later on, this information, once unwrapped to retrieve the absolute values, is used to calculate the nonlinear component of movement and atmospheric artifacts with alternate filtering techniques in both the temporal and spatial domains. The method presents high flexibility with respect to the required number of images and the baselines length. However, better results are obtained with large datasets of short baseline interferograms. The technique has been tested with European Remote Sensing SAR data from an area of Catalonia (Spain) and validated with on-field precise leveling measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CERNin tutkimuskeskuksen rakenteilla olevan hadronikiihdyttimen eräs tarkoitus on todistaa Higgsin bosonin olemassaolo. Higgsin bosonin löytyminen yhtenäistäisi nykyisen hiukkasfysiikan teorian ja antaisi selityksen sille kuinka hiukkaset saavat massansa. Kiihdyttimen CMS koeasema on tarkoitettu erityisesti myonien ilmaisuun. Tämä työ liittyy CMS koeaseman RPC-ilmaisintyypin linkkijärjestelmään, jonka tarkoituksena on käsitellä ilmaisimelta tulevia myonien aiheuttamia signaaleja ja lähettää tiedot tärkeäksi katsotuista törmäystapahtumista tallennettavaksi analysointia varten. Työssä on toteutettu linkkijärjestelmän ohjaus- ja linkkikorteille testiympäristö, jolla voidaan todeta järjestelmän eri osien keskinäinen yhteensopivuus ja toimivuus. Työn alkuosassa esitellään ilmaisimen linkkijärjestelmän eri osat ja niiden merkitykset. Työn loppuosassa käydään läpi eri testimenetelmiä ja analysoidaan niiden antamia tuloksia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The eccentric contraction mode was proposed to be the primary stimulus for optimum angle (angle at which peak torque occurs) shift. However, the training range of motion (or muscle excursion range) could be a stimulus as important. The aim of this study was to assess the influence of the training range of motion stimulus on the hamstring optimum length. It was hypothesised that performing a single set of concentric contractions beyond optimal length (seated at 80° of hip flexion) would lead to an immediate shift of the optimum angle to longer muscle length while performing it below (supine at 0° of hip flexion) would not provide any shift. Eleven male participants were assessed on an isokinetic dynamometer. In both positions, the test consisted of 30 consecutive knee flexions at 4.19 rad · s⁻¹. The optimum angle was significantly shifted by ∼15° in the direction of longer muscle length after the contractions at 80° of hip flexion, while a non-significant shift of 3° was found at 0°. The hamstring fatigability was not influenced by the hip position. It was concluded that the training range of motion seems to be a relevant stimulus for shifting the optimum angle to longer muscle length. Moreover, fatigue appears as a mechanism partly responsible for the observed shift.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To describe the anatomical characteristics and patterns of neurovascular compression in patients suffering classic trigeminal neuralgia (CTN), using high-resolution magnetic resonance imaging (MRI). MATERIALS AND METHODS: The analysis of the anatomy of the trigeminal nerve, brain stem and the vascular structures related to this nerve was made in 100 consecutive patients treated with a Gamma Knife radiosurgery for CTN between December 1999 and September 2004. MRI studies (T1, T1 enhanced and T2-SPIR) with axial, coronal and sagital simultaneous visualization were dynamically assessed using the software GammaPlan?. Three-dimensional reconstructions were also developed in some representative cases. RESULTS: In 93 patients (93%), there were one or several vascular structures in contact, either, with the trigeminal nerve, or close to its origin in the pons. The superior cerebellar artery was involved in 71 cases (76%). Other vessels identified were the antero-inferior cerebellar artery, the basilar artery, the vertebral artery, and some venous structures. Vascular compression was found anywhere along the trigeminal nerve. The mean distance between the nerve compression and the origin of the nerve in the brainstem was 3.76±2.9mm (range 0-9.8mm). In 39 patients (42%), the vascular compression was located proximally and in 42 (45%) the compression was located distally. Nerve dislocation or distortion by the vessel was observed in 30 cases (32%). CONCLUSIONS: The findings of this study are similar to those reported in surgical and autopsy series. This non-invasive MRI-based approach could be useful for diagnostic and therapeutic decisions in CTN, and it could help to understand its pathogenesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Percutaneous cricothyroidotomy may be a lifesaving procedure for airway obstruction, which cannot be relieved by endotracheal intubation and can be performed with specially designed instruments. A new device, the "Quicktrach", was evaluated by an anatomical preparation, flow and resistance measurements, and puncture of the cricothyroid membrane in 55 corpses. The size of the parts of the instrument (needle, plastic cannula, depth gauge) in relation to the size of the larynx is adequate, thus there is little likelihood of perforation of the posterior wall of the larynx. Resistance of the plastic cannula is sufficiently low to allow for adequate ventilation. The duration of time until the cannula is positioned properly in the trachea is significantly shorter, when an incision prior to the puncture is done (83 +/- 88 seconds without incision versus 35 +/- 41 seconds with incision; mean +/- SD). The "Quicktrach" is easy to apply even by inexperienced persons. The incidence of damage to the larynx (lesions including fractures of the thyroid, cricoid and 1. tracheal cartilage in 18%; soft tissue injury in 9%) is relatively high, however considering the live saving character of the procedure these numbers appear to be acceptable. Technical problems which occur with the use of the device are discussed and suggestions for improvement are made.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multispectral images contain information from several spectral wavelengths and currently multispectral images are widely used in remote sensing and they are becoming more common in the field of computer vision and in industrial applications. Typically, one multispectral image in remote sensing may occupy hundreds of megabytes of disk space and several this kind of images may be received from a single measurement. This study considers the compression of multispectral images. The lossy compression is based on the wavelet transform and we compare the suitability of different waveletfilters for the compression. A method for selecting a wavelet filter for the compression and reconstruction of multispectral images is developed. The performance of the multidimensional wavelet transform based compression is compared to other compression methods like PCA, ICA, SPIHT, and DCT/JPEG. The quality of the compression and reconstruction is measured by quantitative measures like signal-to-noise ratio. In addition, we have developed a qualitative measure, which combines the information from the spatial and spectral dimensions of a multispectral image and which also accounts for the visual quality of the bands from the multispectral images.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis studies gray-level distance transforms, particularly the Distance Transform on Curved Space (DTOCS). The transform is produced by calculating distances on a gray-level surface. The DTOCS is improved by definingmore accurate local distances, and developing a faster transformation algorithm. The Optimal DTOCS enhances the locally Euclidean Weighted DTOCS (WDTOCS) with local distance coefficients, which minimize the maximum error from the Euclideandistance in the image plane, and produce more accurate global distance values.Convergence properties of the traditional mask operation, or sequential localtransformation, and the ordered propagation approach are analyzed, and compared to the new efficient priority pixel queue algorithm. The Route DTOCS algorithmdeveloped in this work can be used to find and visualize shortest routes between two points, or two point sets, along a varying height surface. In a digital image, there can be several paths sharing the same minimal length, and the Route DTOCS visualizes them all. A single optimal path can be extracted from the route set using a simple backtracking algorithm. A new extension of the priority pixel queue algorithm produces the nearest neighbor transform, or Voronoi or Dirichlet tessellation, simultaneously with the distance map. The transformation divides the image into regions so that each pixel belongs to the region surrounding the reference point, which is nearest according to the distance definition used. Applications and application ideas for the DTOCS and its extensions are presented, including obstacle avoidance, image compression and surface roughness evaluation.