909 resultados para comparison methods


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Data obtained with two CZE assays for determining carbohydrate-deficient transferrin (CDT) in human serum under routine conditions, the CAPILLARYS CDT and the high-resolution CEofix (HR-CEofix) CDT methods, are in agreement with patient sera that do not exhibit interferences, high trisialo-transferrin (Tf) levels or genetic variants. HR-CEofix CDT levels are somewhat higher compared to those obtained with the CAPILLARYS method and this bias corresponds to the difference of the upper reference values of the two assays. The lower resolution between disialo-Tf and trisialo-Tf observed in the CAPILLARYS system (mean: 1.24) compared to HR-CEofix (mean: 1.74) is believed to be the key for this difference. For critical sera with high trisialo-Tf levels, genetic variants, or certain interferences in the beta-region, the HR-CEofix approach is demonstrated to perform better than CAPILLARYS. However, the determination of CDT with the HR-CEofix method can also be hampered with interferences. Results with disialo-Tf values larger than 3% in the absence of asialo-Tf should be evaluated with immunosubtraction of Tf and possibly also confirmed with another CZE method or by HPLC. Furthermore, data gathered with the N Latex CDT direct immunonephelometric assay suggest that this assay can be used for screening purposes. To reduce the number of false negative results, CDT data above 2.0% should be confirmed using a separation method.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: The simple bedside method for sampling undiluted distal pulmonary edema fluid through a normal suction catheter (s-Cath) has been experimentally and clinically validated. However, there are no data comparing non-bronchoscopic bronchoalveolar lavage (mini-BAL) and s-Cath for assessing lung inflammation in acute hypoxaemic respiratory failure. We designed a prospective study in two groups of patients, those with acute lung injury (ALI)/acute respiratory distress syndrome (ARDS) and those with acute cardiogenic lung edema (ACLE), designed to investigate the clinical feasibility of these techniques and to evaluate inflammation in both groups using undiluted sampling obtained by s-Cath. To test the interchangeability of the two methods in the same patient for studying the inflammation response, we further compared mini-BAL and s-Cath for agreement of protein concentration and percentage of polymorphonuclear cells (PMNs). METHODS: Mini-BAL and s-Cath sampling was assessed in 30 mechanically ventilated patients, 21 with ALI/ARDS and 9 with ACLE. To analyse agreement between the two sampling techniques, we considered only simultaneously collected mini-BAL and s-Cath paired samples. The protein concentration and polymorphonuclear cell (PMN) count comparisons were performed using undiluted sampling. Bland-Altman plots were used for assessing the mean bias and the limits of agreement between the two sampling techniques; comparison between groups was performed by using the non-parametric Mann-Whitney-U test; continuous variables were compared by using the Student t-test, Wilcoxon signed rank test, analysis of variance or Student-Newman-Keuls test; and categorical variables were compared by using chi-square analysis or Fisher exact test. RESULTS: Using protein content and PMN percentage as parameters, we identified substantial variations between the two sampling techniques. When the protein concentration in the lung was high, the s-Cath was a more sensitive method; by contrast, as inflammation increased, both methods provided similar estimates of neutrophil percentages in the lung. The patients with ACLE showed an increased PMN count, suggesting that hydrostatic lung edema can be associated with a concomitant inflammatory process. CONCLUSIONS: There are significant differences between the s-Cath and mini-BAL sampling techniques, indicating that these procedures cannot be used interchangeably for studying the lung inflammatory response in patients with acute hypoxaemic lung injury.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study aims to evaluate whether visualization and integration of the computed tomography (CT) scan of the left atrium (LA) and the esophagus into the three-dimensional (3D) electroanatomical map the day before ablation is accurate compared with integration of an esophagus tag into the electroanatomic LA map visualizing the anatomic relationship during the radiofrequency ablation or whether esophagus movement prohibits esophagus visualization the day before ablation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Methods of heat detection were compared in the Mid- Crest Area Cattle Evaluation Program (MACEP) heifer development program in the 1998-breeding season. A total of 189 heifers from thirteen consignors entered the program on November 10, 1997. These heifers were condition scored, hip height measured, weighed, disposition scored, booster vaccinated, and treated for parasites at the time of arrival. Determination of the heifer’s mature weight was made and a target of 65% of their mature weight at breeding was established. The ration was designed to meet this goal. The heifers were kept in a dry lot until all heifers were AI bred once. The heifers were periodically weighed and condition scored to monitor their gains and the ration was adjusted as needed. The estrus synchronization program consisted of an oral progesterone analog for 14 days; 17 days after completion of the progesterone analog treatment a single injection of prostaglandin was given and the heifers were then estrus detected. Two concurrent methods of estrus detection were utilized: 1) Ovatec â electronic breeding probe (probe), 2) HeatWatchâ estrus detection system (HW), and 3) a combination of probe and HW. Probe readings were obtained each 12 hours and the heifers were continuously monitored for estrus activity using the HW system. The probe was used as the primary estrus detection method and the HW system was used as a back-up system. Those heifers that did not demonstrate any estrus signs prior to 96 hours post prostaglandin treatment were mass inseminated at 96 hours. Post AI breeding, 151 of the heifers were placed on pasture and ran with clean-up bulls for 60 days. The remaining heifers left the program after the AI breeding was completed. Pregnancy to the AI breeding was determined by ultrasound on June 29, 1998. Results from using both probe and HW were 60% pregnant by AI, probe alone was 32% pregnant by AI, and HW alone was 27% pregnant by AI. The result of mass insemination was 20% pregnant by AI.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: Premature babies require supplementation with calcium and phosphorus to prevent metabolic bone disease of prematurity. To guide mineral supplementation, two methods of monitoring urinary excretion of calcium and phosphorus are used: urinary calcium or phosphorus concentration and calcium/creatinine or phosphorus/creatinine ratios. We compare these two methods in regards to their agreement on the need for mineral supplementation. METHODS: Retrospective chart review of 230 premature babies with birthweight <1500 g, undergoing screening of urinary spot samples from day 21 of life and fortnightly thereafter. Hypothetical cut-off values for urine calcium or phosphorus concentration (1 mmol/l) and urine calcium/creatinine ratio (0.5 mol/mol) or phosphorus/creatinine ratio (4 mol/mol) were applied to the sample results. The agreement on whether or not to supplement the respective minerals based on the results with the two methods was compared. Multivariate general linear models sought to identify patient characteristic to predict disagreeing results. RESULTS: 24.8% of cases disagreed on the indication for calcium supplementation, 8.8% for phosphorus. Total daily calcium intake was the only patient characteristic associated with discordant results. CONCLUSIONS: With the intention to supplement the respective mineral, comparison of urinary mineral concentration with mineral/creatinine ratio is moderate for Calcium and good for Phosphorus. The results do not allow to identify superiority of either method on the decision which babies require calcium and/or phosphorus supplements.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A new technique for the detection of microbiological fecal pollution in drinking and in raw surface water has been modified and tested against the standard multiple-tube fermentation technique (most-probable-number, MPN). The performance of the new test in detecting fecal pollution in drinking water has been tested at different incubation temperatures. The basis for the new test was the detection of hydrogen sulfide produced by the hydrogen sulfide producing bacteria which are usually associated with the coliform group. The positive results are indicated by the appearance of a brown to black color in the contents of the fermentation tube within 18 to 24 hours of incubation at 35 (+OR-) .5(DEGREES)C. For this study 158 water samples of different sources have been used. The results were analyzed statistically with the paired t-test and the one-way analysis of variance. No statistically significant difference was noticed between the two methods, when tested 35 (+OR-) .5(DEGREES)C, in detecting fecal pollution in drinking water. The new test showed more positive results with raw surface water, which could be due to the presence of hydrogen sulfide producing bacteria of non-fecal origin like Desulfovibrio and Desulfomaculum. The survival of the hydrogen sulfide producing bacteria and the coliforms was also tested over a 7-day period, and the results showed no significant difference. The two methods showed no significant difference when used to detect fecal pollution at a very low coliform density. The results showed that the new test is mostly effective, in detecting fecal pollution in drinking water, when used at 35 (+OR-) .5(DEGREES)C. The new test is effective, simple, and less expensive when used to detect fecal pollution in drinking water and raw surface water at 35 (+OR-) .5(DEGREES)C. The method can be used for qualitative and/or quantitative analysis of water in the field and in the laboratory. ^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE Therapeutic drug monitoring of patients receiving once daily aminoglycoside therapy can be performed using pharmacokinetic (PK) formulas or Bayesian calculations. While these methods produced comparable results, their performance has never been checked against full PK profiles. We performed a PK study in order to compare both methods and to determine the best time-points to estimate AUC0-24 and peak concentrations (C max). METHODS We obtained full PK profiles in 14 patients receiving a once daily aminoglycoside therapy. PK parameters were calculated with PKSolver using non-compartmental methods. The calculated PK parameters were then compared with parameters estimated using an algorithm based on two serum concentrations (two-point method) or the software TCIWorks (Bayesian method). RESULTS For tobramycin and gentamicin, AUC0-24 and C max could be reliably estimated using a first serum concentration obtained at 1 h and a second one between 8 and 10 h after start of the infusion. The two-point and the Bayesian method produced similar results. For amikacin, AUC0-24 could reliably be estimated by both methods. C max was underestimated by 10-20% by the two-point method and by up to 30% with a large variation by the Bayesian method. CONCLUSIONS The ideal time-points for therapeutic drug monitoring of once daily administered aminoglycosides are 1 h after start of a 30-min infusion for the first time-point and 8-10 h after start of the infusion for the second time-point. Duration of the infusion and accurate registration of the time-points of blood drawing are essential for obtaining precise predictions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to compare the speech in subjects with cleft lip and palate, in whom three methods of the hard palate closure were used. One hundred and thirty-seven children (96 boys, 41 girls; mean age = 12 years, SD = 1·2) with complete unilateral cleft lip and palate (CUCLP) operated by a single surgeon with a one-stage method were evaluated. The management of the cleft lip and soft palate was comparable in all subjects; for hard palate repair, three different methods were used: bilateral von Langenbeck closure (b-vL group, n = 39), unilateral von Langenbeck closure (u-vL group, n = 56) and vomerplasty (v-p group, n = 42). Speech was assessed: (i) perceptually for the presence of a) hypernasality, b) compensatory articulations (CAs), c) audible nasal air emissions (ANE) and d) speech intelligibility; (ii) for the presence of compensatory facial grimacing, (iii) with clinical intra-oral evaluation and (iv) with videonasendoscopy. A total rate of hypernasality requiring pharyngoplasty was 5·1%; total incidence post-oral compensatory articulations (CAs) was 2·2%. The overall speech intelligibility was good in 84·7% of cases. Oronasal fistulas (ONFs) occurred in 15·7% b-vL subjects, 7·1% u-vL subjects and 50% v-p subjects (P < 0·001). No statistically significant intergroup differences for hypernasality, CAs and intelligibility were found (P > 0·1). In conclusion, the speech after early one-stage repair of CUCLP was satisfactory. The method of hard palate repair affected the incidence of ONFs, which, however, caused relatively mild and inconsistent speech errors.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Cephalometric analysis is an essential clinical and research tool in orthodontics for the orthodontic analysis and treatment planning. This paper presents the evaluation of the methods submitted to the Automatic Cephalometric X-Ray Landmark Detection Challenge, held at the IEEE International Symposium on Biomedical Imaging 2014 with an on-site competition. The challenge was set to explore and compare automatic landmark detection methods in application to cephalometric X-ray images. Methods were evaluated on a common database including cephalograms of 300 patients aged six to 60 years, collected from the Dental Department, Tri-Service General Hospital, Taiwan, and manually marked anatomical landmarks as the ground truth data, generated by two experienced medical doctors. Quantitative evaluation was performed to compare the results of a representative selection of current methods submitted to the challenge. Experimental results show that three methods are able to achieve detection rates greater than 80% using the 4 mm precision range, but only one method achieves a detection rate greater than 70% using the 2 mm precision range, which is the acceptable precision range in clinical practice. The study provides insights into the performance of different landmark detection approaches under real-world conditions and highlights achievements and limitations of current image analysis techniques.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES To evaluate the diagnostic performance of seven non-invasive tests (NITs) of liver fibrosis and to assess fibrosis progression over time in HIV/HCV co-infected patients. METHODS Transient elastography (TE) and six blood tests were compared to histopathological fibrosis stage (METAVIR). Participants were followed over three years with NITs at yearly intervals. RESULTS Area under the receiver operating characteristic curve (AUROC) for significant fibrosis (> = F2) in 105 participants was highest for TE (0.85), followed by FIB-4 (0.77), ELF-Test (0.77), APRI (0.76), Fibrotest (0.75), hyaluronic acid (0.70), and Hepascore (0.68). AUROC for cirrhosis (F4) was 0.97 for TE followed by FIB-4 (0.91), APRI (0.89), Fibrotest (0.84), Hepascore (0.82), ELF-Test (0.82), and hyaluronic acid (0.79). A three year follow-up was completed by 87 participants, all on antiretroviral therapy and in 20 patients who completed HCV treatment (9 with sustained virologic response). TE, APRI and Fibrotest did not significantly change during follow-up. There was weak evidence for an increase of FIB-4 (mean increase: 0.22, p = 0.07). 42 participants had a second liver biopsy: Among 38 participants with F0-F3 at baseline, 10 were progessors (1-stage increase in fibrosis, 8 participants; 2-stage, 1; 3-stage, 1). Among progressors, mean increase in TE was 3.35 kPa, in APRI 0.36, and in FIB-4 0.75. Fibrotest results did not change over 3 years. CONCLUSION TE was the best NIT for liver fibrosis staging in HIV/HCV co-infected patients. APRI-Score, FIB-4 Index, Fibrotest, and ELF-Test were less reliable. Routinely available APRI and FIB-4 performed as good as more expensive tests. NITs did not change significantly during a follow-up of three years, suggesting slow liver disease progression in a majority of HIV/HCV co-infected persons on antiretroviral therapy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Residential wood combustion has only recently been recognized as a major contributor to air pollution in Switzerland and in other European countries. A source apportionment method using the aethalometer light absorption parameters was applied to five winter campaigns at three sites in Switzerland: a village with high wood combustion activity in winter, an urban background site and a highway site. The particulate mass from traffic (PMtraffic) and wood burning (PMwb) emissions obtained with this model compared fairly well with results from the 14C source apportionment method. PMwb from the model was also compared to well known wood smoke markers such as anhydrosugars (levoglucosan and mannosan) and fine mode potassium, as well as to a marker recently suggested from the Aerodyne aerosol mass spectrometer (mass fragment m/z 60). Additionally the anhydrosugars were compared to the 14C results and were shown to be comparable to literature values from wood burning emission studies using different types of wood (hardwood, softwood). The levoglucosan to PMwb ratios varied much more strongly between the different campaigns (4–13%) compared to mannosan to PMwb with a range of 1–1.5%. Possible uncertainty aspects for the various methods and markers are discussed.