291 resultados para clot


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A number of thrombectomy devices using a variety of methods have now been developed to facilitate clot removal. We present research involving one such experimental device recently developed in the UK, called a ‘GP’ Thrombus Aspiration Device (GPTAD). This device has the potential to bring about the extraction of a thrombus. Although the device is at a relatively early stage of development, the results look encouraging. In this work, we present an analysis and modeling of the GPTAD by means of the bond graph technique; it seems to be a highly effective method of simulating the device under a variety of conditions. Such modeling is useful in optimizing the GPTAD and predicting the result of clot extraction. The aim of this simulation model is to obtain the minimum pressure necessary to extract the clot and to verify that both the pressure and the time required to complete the clot extraction are realistic for use in clinical situations, and are consistent with any experimentally obtained data. We therefore consider aspects of rheology and mechanics in our modeling.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

According to the World Health Organization, 15 million people suffer stroke worldwide each year, of these, 5 million die and 5 million are permanently disabled. Stroke is therefore a major cause of mortality world-wide. The majority of strokes are caused by a blood clot that occludes an artery in the brain, and although thrombolytic agents such as Alteplase are used to dissolve clots that arise in the arteries of the brain, there are limitations on the use of these thrombolytic agents. However over the past decade, other methods of treatment have been developed which include Thrombectomy Devices e.g. the 'GP' Thrombus Aspiration Device ('GP' TAD). Such devices may be used as an alternative to thrombolytics or in conjunction with them to extract blood clots in arteries such as the middle cerebral artery of the midbrain brain, and the posterior inferior cerebellar artery (PICA) of the posterior aspect of the brain. In this paper, we mathematically model the removal of blood clots using the 'GP' TAD from selected arteries of the brain where blood clots may arise taking into account factors such as the resistances, compliances and inertances effects. Such mathematical modelling may have potential uses in predicting the pressures necessary to extract blood clots of given lengths, and masses from arteries in the Circle of Willis - posterior circulation of the brain

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: In this work, we present the analysis, design and optimization of one experimental device recently developed in the UK, called the 'GP' Thrombus Aspiration Device (GPTAD). This device has been designed to remove blood clots without the need to make contact with the clot itself thereby potentially reducing the risk of problems such as downstream embolisation. Method: To obtain the minimum pressure necessary to extract the clot and to optimize the device, we have simulated the performance of the GPTAD analysing the resistances, compliances and inertances effects. We model a range of diameters for the GPTAD considering different forces of adhesion of the blood clot to the artery wall, and different lengths of blood clot. In each case we determine the optimum pressure required to extract the blood clot from the artery using the GPTAD, which is attached at its proximal end to a suction pump. Result: We then compare the results of our mathematical modelling to measurements made in laboratory using plastic tube models of arteries of comparable diameter. We use abattoir porcine blood clots that are extracted using the GPTAD. The suction pressures required for such clot extraction in the plastic tube models compare favourably with those predicted by the mathematical modelling. Discussion & Conclusion: We conclude therefore that the mathematical modelling is a useful technique in predicting the performance of the GPTAD and may potentially be used in optimising the design of the device.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recently, we have presented some studies concerning the analysis, design and optimization of one experimental device developed in the UK - GPTAD - which has been designed to remove blood clots without the need to make contact with the clot itself, thereby potentially reducing the risk of problems such as downstream embolisation. Based on the idea of a modification of the previous device, in this work, we present a model based in the use of stents like the SolitaireTM FR, which is in contact with the clot itself. In the case of such devices, the stent is self-expandable and the extraction of the blood clot is faciliatated by the stent, which must be inside the clot. Such stents are generally inserted in position by using the guidewire inserted into the catheter. This type of modeling could potentially be useful in showing how the blood clot is moved by the various different forces involved. The modelling has been undertaken by analyzing the resistances, compliances and inertances effects. We model an artery and blood clot for range of forces for the guidewire. In each case we determine the interaction between blood clot, stent and artery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Here we report the crystal structure at ≈4-Å resolution of a selectively proteolyzed bovine fibrinogen. This key component in hemostasis is an elongated 340-kDa glycoprotein in the plasma that upon activation by thrombin self-assembles to form the fibrin clot. The crystals are unusual because they are made up of end-to-end bonded molecules that form flexible filaments. We have visualized the entire coiled-coil region of the molecule, which has a planar sigmoidal shape. The primary polymerization receptor pockets at the ends of the molecule face the same way throughout the end-to-end bonded filaments, and based on this conformation, we have developed an improved model of the two-stranded protofibril that is the basic building block in fibrin. Near the middle of the coiled-coil region, the plasmin-sensitive segment is a hinge about which the molecule adopts different conformations. This segment also includes the boundary between the three- and four-stranded portions of the coiled coil, indicating the location on the backbone that anchors the extended flexible Aα arm. We suggest that a flexible branch point in the molecule may help accommodate variability in the structure of the fibrin clot.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Mediterranean wall, which is a collection of defensive constructions along the coast, was built during the Spanish War (1936-39) to prevent enemy attacks. It´s called this way like the Atlantic Wall, which was built after the Second World War. These group of buildings consist of batteries, bunkers and barracks placed along the coastline, sometimes next to another kind of infrastructure. Its location (typical of a military strategy) and its peculiar morphology are like another ones: the historical watchtowers ones. They were built by the Kingdom of Spain in the same geography four centuries earlier although, in our case, the buildings are updated to the conditions of contemporary wars: camouflage against air raids. A collection of anti-aircraft devices, placed along the coast since the late 1937, were risen following the instructions of the Valencian State to defend both citizens and cities from the aviation´s bombings. The following military settlements, organized from North to South, are part of the most relevant ones of the coast of Alicante: the Denia and Javea ones, the North of Alicante and Southwest of Alicante ones, the Portichol one, the Galvany´s Clot one and, finally, the Cape and Bay of Santa Pola ones. Remains of more than 60 architectural elements, that document the first concrete´s ruins, are still there. This paper tries to document all of them (providing their location, their morphological genealogy and including some drawings of the current state) to contribute to their revaluation and to help to their necessary protection. They are a legacy of architectural heritage which consolidates and increases the memory of our culture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). It addresses the diagnosis and management of nonvariceal upper gastrointestinal hemorrhage (NVUGIH). Main Recommendations MR1. ESGE recommends immediate assessment of hemodynamic status in patients who present with acute upper gastrointestinal hemorrhage (UGIH), with prompt intravascular volume replacement initially using crystalloid fluids if hemodynamic instability exists (strong recommendation, moderate quality evidence). MR2. ESGE recommends a restrictive red blood cell transfusion strategy that aims for a target hemoglobin between 7 g/dL and 9 g/dL. A higher target hemoglobin should be considered in patients with significant co-morbidity (e. g., ischemic cardiovascular disease) (strong recommendation, moderate quality evidence). MR3. ESGE recommends the use of the Glasgow-Blatchford Score (GBS) for pre-endoscopy risk stratification. Outpatients determined to be at very low risk, based upon a GBS score of 0 - 1, do not require early endoscopy nor hospital admission. Discharged patients should be informed of the risk of recurrent bleeding and be advised to maintain contact with the discharging hospital (strong recommendation, moderate quality evidence). MR4. ESGE recommends initiating high dose intravenous proton pump inhibitors (PPI), intravenous bolus followed by continuous infusion (80 mg then 8 mg/hour), in patients presenting with acute UGIH awaiting upper endoscopy. However, PPI infusion should not delay the performance of early endoscopy (strong recommendation, high quality evidence). MR5. ESGE does not recommend the routine use of nasogastric or orogastric aspiration/lavage in patients presenting with acute UGIH (strong recommendation, moderate quality evidence). MR6. ESGE recommends intravenous erythromycin (single dose, 250 mg given 30 - 120 minutes prior to upper gastrointestinal [GI] endoscopy) in patients with clinically severe or ongoing active UGIH. In selected patients, pre-endoscopic infusion of erythromycin significantly improves endoscopic visualization, reduces the need for second-look endoscopy, decreases the number of units of blood transfused, and reduces duration of hospital stay (strong recommendation, high quality evidence). MR7. Following hemodynamic resuscitation, ESGE recommends early (≤ 24 hours) upper GI endoscopy. Very early (< 12 hours) upper GI endoscopy may be considered in patients with high risk clinical features, namely: hemodynamic instability (tachycardia, hypotension) that persists despite ongoing attempts at volume resuscitation; in-hospital bloody emesis/nasogastric aspirate; or contraindication to the interruption of anticoagulation (strong recommendation, moderate quality evidence). MR8. ESGE recommends that peptic ulcers with spurting or oozing bleeding (Forrest classification Ia and Ib, respectively) or with a nonbleeding visible vessel (Forrest classification IIa) receive endoscopic hemostasis because these lesions are at high risk for persistent bleeding or rebleeding (strong recommendation, high quality evidence). MR9. ESGE recommends that peptic ulcers with an adherent clot (Forrest classification IIb) be considered for endoscopic clot removal. Once the clot is removed, any identified underlying active bleeding (Forrest classification Ia or Ib) or nonbleeding visible vessel (Forrest classification IIa) should receive endoscopic hemostasis (weak recommendation, moderate quality evidence). MR10. In patients with peptic ulcers having a flat pigmented spot (Forrest classification IIc) or clean base (Forrest classification III), ESGE does not recommend endoscopic hemostasis as these stigmata present a low risk of recurrent bleeding. In selected clinical settings, these patients may be discharged to home on standard PPI therapy, e. g., oral PPI once-daily (strong recommendation, moderate quality evidence). MR11. ESGE recommends that epinephrine injection therapy not be used as endoscopic monotherapy. If used, it should be combined with a second endoscopic hemostasis modality (strong recommendation, high quality evidence). MR12. ESGE recommends PPI therapy for patients who receive endoscopic hemostasis and for patients with adherent clot not receiving endoscopic hemostasis. PPI therapy should be high dose and administered as an intravenous bolus followed by continuous infusion (80 mg then 8 mg/hour) for 72 hours post endoscopy (strong recommendation, high quality evidence). MR13. ESGE does not recommend routine second-look endoscopy as part of the management of nonvariceal upper gastrointestinal hemorrhage (NVUGIH). However, in patients with clinical evidence of rebleeding following successful initial endoscopic hemostasis, ESGE recommends repeat upper endoscopy with hemostasis if indicated. In the case of failure of this second attempt at hemostasis, transcatheter angiographic embolization (TAE) or surgery should be considered (strong recommendation, high quality evidence). MR14. In patients with NVUGIH secondary to peptic ulcer, ESGE recommends investigating for the presence of Helicobacter pylori in the acute setting with initiation of appropriate antibiotic therapy when H. pylori is detected. Re-testing for H. pylori should be performed in those patients with a negative test in the acute setting. Documentation of successful H. pylori eradication is recommended (strong recommendation, high quality evidence). MR15. In patients receiving low dose aspirin for secondary cardiovascular prophylaxis who develop peptic ulcer bleeding, ESGE recommends aspirin be resumed immediately following index endoscopy if the risk of rebleeding is low (e. g., FIIc, FIII). In patients with high risk peptic ulcer (FIa, FIb, FIIa, FIIb), early reintroduction of aspirin by day 3 after index endoscopy is recommended, provided that adequate hemostasis has been established (strong recommendation, moderate quality evidence).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Contiene: T. I (XIV, 444 p.) -- T. II (392 p.) -- T. III (412 p.) -- T. IV (508 p.) -- T. V (510 p.) -- T. VI (384 p.) -- T. VII (376 p.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-06

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel and precise assay that facilitates high-throughput screening of fibrinolytic agents was developed based on the automated assessment of the euglobulin clot lysis time in microtitre plates. Euglobulin fractions from fresh plasma samples were assessed over 28 days to determine the inter-assay and intra-assay precision. The intra-assay (coefficient of variation range, 0.7-2.6%) and inter-assay precision (coefficient of variation range, 6.8-12.1%) was found to be well within limits required by the Food and Drug Administration. On day 1 and day 28, the results of the microtitre plate euglobulin clot lysis time method were compared with tissue plasminogen activator activity, plasminogen activator inhibitor activity and results produced on fibrin plates. All comparisons were found to correlate significantly. The validity of this method for assaying fibrinolytic agents was assessed by comparing dose-response curves for streptokinase produced using fibrin plates and this method. The critical influence of ambient temperature on the inter-assay reproducibility of this method was established by testing samples over a range of temperatures between 20degreesC and 40degreesC. (C) 2004 Lippincott Williams Wilkins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In-vitro experimentation was performed on porcine and human blood to determine their comparative responsiveness to a novel fibrinolytic inhibitor and thereby assess whether the pig is a suitable animal model for subsequent in-vivo testing of this inhibitor. Thromboelastography showed the clots formed from porcine whole blood to be highly resistant to tissue plasminogen activator (t-PA)-catalyzed lysis, and this communication offers the resistance of porcine plasminogen to activation by t-PA as an explanation. Porcine blood containing 100 and 1500 IU/ml added t-PA lysed very slowly, having LY30 values of 1.9 +/- 1.4 and 2.9 +/- 1.9%, respectively. In contrast, the LY30 values for the human clots containing 100 and 1500 IU/ml t-PA were 77.1 +/- 6.3 and 93.3 +/- 1.3%, respectively. Moreover, purified porcine plasminogen was activated very slowly by added t-PA in the presence of both human and porcine fibrin. Activation of plasminogen by the endogenous activators, as measured by the euglobulin clot lysis time, was greatly prolonged for the pig (22 +/- 3 h) compared with the human (3.5 +/- 1.5 h). These results suggest caution in using the pig as an experimental model when studying the effects of various agents on fibrinolysis.