955 resultados para automatic test and measurement
Resumo:
Organizations can use the valuable tool of data envelopment analysis (DEA) to make informed decisions on developing successful strategies, setting specific goals, and identifying underperforming activities to improve the output or outcome of performance measurement. The Handbook of Research on Strategic Performance Management and Measurement Using Data Envelopment Analysis highlights the advantages of using DEA as a tool to improve business performance and identify sources of inefficiency in public and private organizations. These recently developed theories and applications of DEA will be useful for policymakers, managers, and practitioners in the areas of sustainable development of our society including environment, agriculture, finance, and higher education sectors. All rights reserved.
Resumo:
This dissertation describes the findings and implications of a correlational analysis. Scores earned on the Computerized Placement Test (CPT), sentence skills, were compared to essay scores of advanced English as a Second Language (ESL) students. As the CPT is designed for native speakers of English, it was hypothesized that it could be an invalid or unreliable instrument for non-native speakers. Florida community college students are mandated to take the CPT to determine preparedness, as are students at many other U.S. and Canadian colleges. If incoming students score low on the CPT, they may be required to take up to three semesters of remedial coursework. It is essential that scores earned by non-native speakers of English accurately reflect their ability level. They constitute a large and growing body of non-traditional students enrolled at community colleges.^ The study was conducted at Miami-Dade Community College, Wolfson Campus, fall 1997. Participants included 106 advanced ESL students who took both the CPT sentence skills test and wrote final essay exams. The essay exams were holistically scored by trained readers. Also, the participants took the Placement Articulation Software Service (PASS) exam, an alternative form of the CPT. Scores on the CPT and essays were compared by means of a Pearson product-moment correlation to validate the CPT. Scores on the CPT and the PASS exam were compared in the same manner to verify reliability. A percentage of appropriate placements was determined by comparing essay scores to CPT cutoff score ranges. Finally, the instruments were evaluated by means of independent-samples t-tests for performance differences between gender, age, and first language groups.^ The results indicate that the CPT sentence skills test is a valid and reliable placement instrument for advanced- level ESL students who intend to pursue community college degrees. The correlations demonstrated a substantial relationship between CPT and essay scores and a marked relationship between CPT and PASS scores. Appropriate placements were made in 86% of the cases. Furthermore, the CPT was found to discriminate equally among the gender, age, and first language groups included in this study. ^
Resumo:
The present study measured a chemotherapy drug, etoposide, in pig cerebrospinal fluid after intraventricular administrations were made directly into the fourth ventricle of the brain; cytotoxic concentrations for a twenty-four hour period after infusions. The analytical method developed validates the potential treatment of malignant brain tumors. The increase in serum carotenoid concentration in 30 healthy individuals was measured after supplementation with lutein. HPLC analysis of serum levels of carotenoids showed an increase in the concentration of lutein and a constant concentration of other major serum carotenoids. An initial attempt to measure the enthalpy of aggregation of xanthophylls was conducted by using ultraviolet-visible spectroscopy. The enthalpy of lutein aggregation and AH range of zeaxanthin disordering of aggregation are reported. Monomethyl ether of lutein did not aggregate in any of the aqueous solutions.
Resumo:
Topological quantum error correction codes are currently among the most promising candidates for efficiently dealing with the decoherence effects inherently present in quantum devices. Numerically, their theoretical error threshold can be calculated by mapping the underlying quantum problem to a related classical statistical-mechanical spin system with quenched disorder. Here, we present results for the general fault-tolerant regime, where we consider both qubit and measurement errors. However, unlike in previous studies, here we vary the strength of the different error sources independently. Our results highlight peculiar differences between toric and color codes. This study complements previous results published in New J. Phys. 13, 083006 (2011).
Resumo:
Executive functions (EF) such as self-monitoring, planning, and organizing are known to develop through childhood and adolescence. They are of potential importance for learning and school performance. Earlier research into the relation between EF and school performance did not provide clear results possibly because confounding factors such as educational track, boy-girl differences, and parental education were not taken into account. The present study therefore investigated the relation between executive function tests and school performance in a highly controlled sample of 173 healthy adolescents aged 12–18. Only students in the pre-university educational track were used and the performance of boys was compared to that of girls. Results showed that there was no relation between the report marks obtained and the performance on executive function tests, notably the Sorting Test and the Tower Test of the Delis-Kaplan Executive Functions System (D-KEFS). Likewise, no relation was found between the report marks and the scores on the Behavior Rating Inventory of Executive Function—Self-Report Version (BRIEF-SR) after these were controlled for grade, sex, and level of parental education. The findings indicate that executive functioning as measured with widely used instruments such as the BRIEF-SR does not predict school performance of adolescents in preuniversity education any better than a student's grade, sex, and level of parental education.
Resumo:
Many applications, including communications, test and measurement, and radar, require the generation of signals with a high degree of spectral purity. One method for producing tunable, low-noise source signals is to combine the outputs of multiple direct digital synthesizers (DDSs) arranged in a parallel configuration. In such an approach, if all noise is uncorrelated across channels, the noise will decrease relative to the combined signal power, resulting in a reduction of sideband noise and an increase in SNR. However, in any real array, the broadband noise and spurious components will be correlated to some degree, limiting the gains achieved by parallelization. This thesis examines the potential performance benefits that may arise from using an array of DDSs, with a focus on several types of common DDS errors, including phase noise, phase truncation spurs, quantization noise spurs, and quantizer nonlinearity spurs. Measurements to determine the level of correlation among DDS channels were made on a custom 14-channel DDS testbed. The investigation of the phase noise of a DDS array indicates that the contribution to the phase noise from the DACs can be decreased to a desired level by using a large enough number of channels. In such a system, the phase noise qualities of the source clock and the system cost and complexity will be the main limitations on the phase noise of the DDS array. The study of phase truncation spurs suggests that, at least in our system, the phase truncation spurs are uncorrelated, contrary to the theoretical prediction. We believe this decorrelation is due to the existence of an unidentified mechanism in our DDS array that is unaccounted for in our current operational DDS model. This mechanism, likely due to some timing element in the FPGA, causes some randomness in the relative phases of the truncation spurs from channel to channel each time the DDS array is powered up. This randomness decorrelates the phase truncation spurs, opening the potential for SFDR gain from using a DDS array. The analysis of the correlation of quantization noise spurs in an array of DDSs shows that the total quantization noise power of each DDS channel is uncorrelated for nearly all values of DAC output bits. This suggests that a near N gain in SQNR is possible for an N-channel array of DDSs. This gain will be most apparent for low-bit DACs in which quantization noise is notably higher than the thermal noise contribution. Lastly, the measurements of the correlation of quantizer nonlinearity spurs demonstrate that the second and third harmonics are highly correlated across channels for all frequencies tested. This means that there is no benefit to using an array of DDSs for the problems of in-band quantizer nonlinearities. As a result, alternate methods of harmonic spur management must be employed.
Resumo:
Today, the use of heavy metals and chemical products industry expanded. The presence of significant amounts of, pollutants in industrial waste water can lead to serious risks to the environment and human health have heavy metals like chromium is one example of the future of salmon knock pond environment. Chromium is an essential element in the diet, but high doses of this element is very dangerous. Hence the use of chemical methods as a tool for the removal of metals from waste water pond be used. The aim of this study was to investigate the mineral kaolin adsorbents for the removal of chromium is water. Thus, the effect of different concentrations of absorbent micro amounts of chromium absorption and variable temperature, pH and electrolytes were studied. During the investigation of spectroscopic instrument (Varian) UV-VIS are used. Comparison of the absorption mechanism of chromium adsorption by the adsorbent with nano-absorbent kaolin kaolin was investigated. According to the studies done in the same conditions of temperature, pH and shaking rate of chromium absorption by nano kaolin kaolin is much more attractive. Therefore, its use as an adsorbent abundant, cheap, accessible, efficient and effective is proposed.
In Situ Characterization of Optical Absorption by Carbonaceous Aerosols: Calibration and Measurement
Resumo:
Light absorption by aerosols has a great impact on climate change. A Photoacoustic spectrometer (PA) coupled with aerosol-based classification techniques represents an in situ method that can quantify the light absorption by aerosols in a real time, yet significant differences have been reported using this method versus filter based methods or the so-called difference method based upon light extinction and light scattering measurements. This dissertation focuses on developing calibration techniques for instruments used in measuring the light absorption cross section, including both particle diameter measurements by the differential mobility analyzer (DMA) and light absorption measurements by PA. Appropriate reference materials were explored for the calibration/validation of both measurements. The light absorption of carbonaceous aerosols was also investigated to provide fundamental understanding to the absorption mechanism. The first topic of interest in this dissertation is the development of calibration nanoparticles. In this study, bionanoparticles were confirmed to be a promising reference material for particle diameter as well as ion-mobility. Experimentally, bionanoparticles demonstrated outstanding homogeneity in mobility compared to currently used calibration particles. A numerical method was developed to calculate the true distribution and to explain the broadening of measured distribution. The high stability of bionanoparticles was also confirmed. For PA measurement, three aerosol with spherical or near spherical shapes were investigated as possible candidates for a reference standard: C60, copper and silver. Comparisons were made between experimental photoacoustic absorption data with Mie theory calculations. This resulted in the identification of C60 particles with a mobility diameter of 150 nm to 400 nm as an absorbing standard at wavelengths of 405 nm and 660 nm. Copper particles with a mobility diameter of 80 nm to 300 nm are also shown to be a promising reference candidate at wavelength of 405 nm. The second topic of this dissertation focuses on the investigation of light absorption by carbonaceous particles using PA. Optical absorption spectra of size and mass selected laboratory generated aerosols consisting of black carbon (BC), BC with non-absorbing coating (ammonium sulfate and sodium chloride) and BC with a weakly absorbing coating (brown carbon derived from humic acid) were measured across the visible to near-IR (500 nm to 840 nm). The manner in which BC mixed with each coating material was investigated. The absorption enhancement of BC was determined to be wavelength dependent. Optical absorption spectra were also taken for size and mass selected smoldering smoke produced from six types of commonly seen wood in a laboratory scale apparatus.
Resumo:
Nowadays the production of increasingly complex and electrified vehicles requires the implementation of new control and monitoring systems. This reason, together with the tendency of moving rapidly from the test bench to the vehicle, leads to a landscape that requires the development of embedded hardware and software to face the application effectively and efficiently. The development of application-based software on real-time/FPGA hardware could be a good answer for these challenges: FPGA grants parallel low-level and high-speed calculation/timing, while the Real-Time processor can handle high-level calculation layers, logging and communication functions with determinism. Thanks to the software flexibility and small dimensions, these architectures can find a perfect collocation as engine RCP (Rapid Control Prototyping) units and as smart data logger/analyser, both for test bench and on vehicle application. Efforts have been done for building a base architecture with common functionalities capable of easily hosting application-specific control code. Several case studies originating in this scenario will be shown; dedicated solutions for protype applications have been developed exploiting a real-time/FPGA architecture as ECU (Engine Control Unit) and custom RCP functionalities, such as water injection and testing hydraulic brake control.
Resumo:
Long-term monitoring of acoustical environments is gaining popularity thanks to the relevant amount of scientific and engineering insights that it provides. The increasing interest is due to the constant growth of storage capacity and computational power to process large amounts of data. In this perspective, machine learning (ML) provides a broad family of data-driven statistical techniques to deal with large databases. Nowadays, the conventional praxis of sound level meter measurements limits the global description of a sound scene to an energetic point of view. The equivalent continuous level Leq represents the main metric to define an acoustic environment, indeed. Finer analyses involve the use of statistical levels. However, acoustic percentiles are based on temporal assumptions, which are not always reliable. A statistical approach, based on the study of the occurrences of sound pressure levels, would bring a different perspective to the analysis of long-term monitoring. Depicting a sound scene through the most probable sound pressure level, rather than portions of energy, brought more specific information about the activity carried out during the measurements. The statistical mode of the occurrences can capture typical behaviors of specific kinds of sound sources. The present work aims to propose an ML-based method to identify, separate and measure coexisting sound sources in real-world scenarios. It is based on long-term monitoring and is addressed to acousticians focused on the analysis of environmental noise in manifold contexts. The presented method is based on clustering analysis. Two algorithms, Gaussian Mixture Model and K-means clustering, represent the main core of a process to investigate different active spaces monitored through sound level meters. The procedure has been applied in two different contexts: university lecture halls and offices. The proposed method shows robust and reliable results in describing the acoustic scenario and it could represent an important analytical tool for acousticians.
Resumo:
A dissertação em apreço resultou da necessidade em otimizar os recursos técnicos, mas sobretudo humanos, afetos às verificações de instrumentos de medição, no âmbito do Controlo Metrológico Legal. Estas verificações, realizadas nos termos do cumprimento das competências outrora atribuídas à Direção de Serviços da Qualidade da então Direção Regional da Economia do Norte, eram operacionalizadas pela Divisão da Qualidade e Licenciamento, na altura dirigida pelo subscritor da presente tese, nomeadamente no que respeita aos ensaios efetuados, em laboratório, a manómetros analógicos. O objetivo principal do trabalho foi alcançado mediante o desenvolvimento de um automatismo, materializado pela construção de um protótipo, cuja aplicação ao comparador de pressão múltiplo, dantes em utilização, permitiria realizar a leitura da indicação de cada manómetro analógico através de técnicas de processamento de imagem, função esta tradicionalmente efetuada manualmente por um operador especializado. As metodologias de comando, controlo e medição desse automatismo foram realizadas através de um algoritmo implementado no software LabVIEW® da National Intruments, particularmente no que respeita ao referido processamento das imagens adquiridas por uma câmara de vídeo USB. A interface com o hardware foi concretizada recorrendo a um módulo de Aquisição de Dados Multifuncional (DAQ) USB-6212, do mesmo fabricante. Para o posicionamento horizontal e vertical da câmara de vídeo USB, recorreu-se a guias lineares acionadas por motores de passo, sendo que estes dispositivos foram igualmente empregues no acionamento do comparador de pressão. Por último, procedeu-se à aquisição digital da leitura do padrão, recorrendo à respetiva virtualização, bem como a uma aplicação desenvolvida neste projeto, designada appMAN, destinada à gestão global do referido automatismo, nomeadamente no que se refere ao cálculo do resultado da medição, erro e incerteza associada, e emissão dos respetivos documentos comprovativos.
Resumo:
The present work is a part of the large project with purpose to qualify the Flash memory for automotive application using a standardized test and measurement flow. High memory reliability and data retention are the most critical parameters in this application. The current work covers the functional tests and data retention test. The purpose of the data retention test is to obtain the data retention parameters of the designed memory, i.e. the maximum time of information storage at specified conditions without critical charge leakage. For this purpose the charge leakage from the cells, which results in decrease of cells threshold voltage, was measured after a long-time hightemperature treatment at several temperatures. The amount of lost charge for each temperature was used to calculate the Arrhenius constant and activation energy for the discharge process. With this data, the discharge of the cells at different temperatures during long time can be predicted and the probability of data loss after years can be calculated. The memory chips, investigated in this work, were 0.035 μm CMOS Flash memory testchips, designed for further use in the Systems-on-Chips for automotive electronics.
Resumo:
O presente trabalho apresenta um projeto e análise de uma antena monopolo planar multibanda operante nas frequências de 2000 MHz, 2500 MHz e 3500 MHz para aplicação em dispositivos móveis 3G e 4G. Dentre essas faixas estão contidos os espectros 3G (1895- 2165 MHz), 4G (2500-2690 MHz) e 4G (3400-3600 MHz) utilizadas pelo LTE e WIMAX 3,5. Para o desenvolvimento desse estudo foi tomado como referência uma antena dual-band de Hua- Ming Chen projetada para operar em sistemas ISM 1800 MHz, redes Wireless e Bluetooth 2400 MHz. O projeto proposto neste trabalho é uma modificação na estrutura da antena dual-band adaptada para tripla ressonância simultânea em frequências utilizadas em redes móveis 4G. Para alcançar o objetivo proposto utilizou-se para simulação o software CST® MICROWAVE STUDIO baseado no método Integração Finita no Domínio, as simulações foram feitas no domínio do tempo. Após obtenção satisfatória dos resultados simulados, um protótipo da antena foi confeccionado para medição e teste, os resultados apresentados são coerentes aos obtidos na simulação, o que valida o método proposto.
Resumo:
In this talk we investigate the usage of spectrally shaped amplified spontaneous emission (ASE) in order to emulate highly dispersed wavelength division multiplexed (WDM) signals in an optical transmission system. Such a technique offers various simplifications to large scale WDM experiments. Not only does it offer a reduction in transmitter complexity, removing the need for multiple source lasers, it potentially reduces the test and measurement complexity by requiring only the centre channel of a WDM system to be measured in order to estimate WDM worst case performance. The use of ASE as a test and measurement tool is well established in optical communication systems and several measurement techniques will be discussed [1, 2]. One of the most prevalent uses of ASE is in the measurement of receiver sensitivity where ASE is introduced in order to degrade the optical signal to noise ratio (OSNR) and measure the resulting bit error rate (BER) at the receiver. From an analytical point of view noise has been used to emulate system performance, the Gaussian Noise model is used as an estimate of highly dispersed signals and has had consider- able interest [3]. The work to be presented here extends the use of ASE by using it as a metric to emulate highly dispersed WDM signals and in the process reduce WDM transmitter complexity and receiver measurement time in a lab environment. Results thus far have indicated [2] that such a transmitter configuration is consistent with an AWGN model for transmission, with modulation format complexity and nonlinearities playing a key role in estimating the performance of systems utilising the ASE channel emulation technique. We conclude this work by investigating techniques capable of characterising the nonlinear and damage limits of optical fibres and the resultant information capacity limits. REFERENCES McCarthy, M. E., N. Mac Suibhne, S. T. Le, P. Harper, and A. D. Ellis, “High spectral efficiency transmission emulation for non-linear transmission performance estimation for high order modulation formats," 2014 European Conference on IEEE Optical Communication (ECOC), 2014. 2. Ellis, A., N. Mac Suibhne, F. Gunning, and S. Sygletos, “Expressions for the nonlinear trans- mission performance of multi-mode optical fiber," Opt. Express, Vol. 21, 22834{22846, 2013. Vacondio, F., O. Rival, C. Simonneau, E. Grellier, A. Bononi, L. Lorcy, J. Antona, and S. Bigo, “On nonlinear distortions of highly dispersive optical coherent systems," Opt. Express, Vol. 20, 1022-1032, 2012.