936 resultados para analytical method


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A copper phthalocyanine/multiwalled carbon nanotube film-modified glassy carbon electrode has been used for the determination of the herbicide glyphosate (Gly) at -50 mV vs. SCE by electrochemical oxidation using differential pulse voltamtnetry (DPV). Cyclic voltammetry and electrochemical impedance spectroscopy showed that Gly is adsorbed on the metallic centre of the copper phthalocyanine molecule, with formation of Gly-copper ion complexes. An analytical method was developed using DPV in pH 7.4 phosphate buffer solution, without any pretreatment steps: Gly was determined in the concentration range of 0.83-9.90 mu mol L(-1), with detection limit 12.2 nmol L(-1) (2.02 mu g L(-1))

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An analytical procedure for the separation and quantification of ethyl acetate, ethyl butyrate, ethyl hexanoate, ethyl lactate, ethyl octanoate, ethyl nonanoate, ethyl decanoate, isoamyl octanoate, and ethyl laurate in cachaca, rum, and whisky by direct injection gas chromatography-mass spectrometry was developed. The analytical method is simple, selective, and appropriated for the determination of esters in distilled spirits. The limit of detection ranged from 29 (ethyl hexanoate) to 530 (ethyl acetate) mu g L-1, whereas the standard deviation for repeatability was between 0.774% (ethyl hexanoate) and 5.05% (isoamyl octanoate). Relative standard deviation values for accuracy vary from 90.3 to 98.5% for ethyl butyrate and ethyl acetate, respectively. Ethyl acetate was shown to be the major ester in cachaca (median content of 22.6 mg 100 mL(-1) anhydrous alcohol), followed by ethyl lactate (median content of 8.32 mg 100 mL(-1) anhydrous alcohol). Cachaca produced in copper and hybrid alembic present a higher content of ethyl acetate and ethyl lactate than those produced in a stainless-steel column, whereas cachaca produced by distillation in a stainless-steel column present a higher content of ethyl octanoate, ethyl decanoate, and ethyl laurate. As expected, ethyl acetate is the major ester in whiskey and rum, followed by ethyl lactate for samples of rum. Nevertheless, whiskey samples exhibit ethyl lactate at contents lower or at the same order of magnitude of the fatty esters.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A biomimetic sensor is proposed as a promising new analytical method for determination of captopril in different classes of samples. The sensor was prepared by modifying a carbon paste electrode with iron (II) phthalocyanine bis(pyridine) [FePe(dipy)] complex. Amperometric measurements in a batch analytical mode were first carried out in order to optimize the sensor response. An applied potential lower than 0.2 V vs Ag vertical bar AgCl in 0.1 mol L(-1) of TRIS buffer at pH 8.0 provided the best response, with a linear range of 2.5 x 10(-5) to 1.7 x 10(-4) mol L(-1). A detailed investigation of the selectivity of the sensor, employing seventeen other drugs, was also performed. Recovery studies were carried out using biological and environment samples in order to evaluate the sensor`s potential for use with these sample classes. Finally, the performance of the biomimetic sensor was optimized in a flow injection (FIA) system using a wall jet electrochemical cell. Under optimized flow conditions, a broad linear response range, from 5.0 x 10(-4) to 2.5 x 10(-2) mol L(-1), was obtained for captopril, with a sensitivity of 210 +/- 1 mu A L mol(-1).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Determination of anabolic steroids often requires the use of elaborate techniques such as gas chromatography - mass spectrometry (GC-MS), gas liquid chromatography (GLC) and more recently high performance liquid chromatography (HPLC). Most of these methods employ derivatisation techniques prior to detection which makes them tedious and relatively time consuming. Other methods demand a great deal of skill. A simple and rapid analytical method, based on differential pulse polarography at a dropping mercury electrode has been developed for the determination of various anabolic steroids in a range of commercially available pharmaceutical preparations. Detailed investigation of the electrochemical behaviour of these steroids was made in order to elucidate the electrode processes involved, in addition to optimising the method. Several other analytical methods such as GC-MS, NMR, ultraviolet (UV), infrared (IR) spectroscopy were also used to confirm the products of the chemical and electrochemical reactions. Possible reactions are suggested. Various extraction procedures were examined for separation of selected steroids from the oil-based or pill matrix and their suitability for polarographic determination is discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Evaluates the current Australian Standard method (AS3853.1) for the determination of total hexavalent chromium (Cr(VI)) in stainless steel welding fume. Investigates the extraction kinetics of this Cr(VI) into a range of media. Develops an analytical method for the determination of Cr(VI) in acidic extract solutions and investigates the extraction of Cr(VI) under simulated in vivo conditions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A highly sensitive and simple analytical method was developed for analyzing the binary mixed pesticides of prometryne and acetochlor in soil–water system by gas chromatography/mass spectrometry (GC/MS). The sample solution was first purified by C18 solid-phase extraction column, which was leached by acetone. The leachate was enriched to 1.0 mL by pressure blowing concentrator and then analyzed by GC/MS. The linear calibration curves were showed in the range of 1–15 μg/mL with a correlation coefficient of 0.9991. The average recoveries (n = 5) were between 95.3 and 115.7%, with relative standard deviations ranged from 1.71 and 7.95%. The limits of detection of Prometryne/Acetochlor were up to 0.06 and 0.17 μg/mL, respectively. This method provides a reliable approach to examine and evaluate the residues of prometryne and acetochlor in the soil–water system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Using a column packed with fully porous particles, four methods for controlling the flow rates at which gradient elution runs are conducted in very high pressure liquid chromatography (VHPLC) were tested to determine whether reproducible thermal conditions could be achieved, such that subsequent analyses would proceed at nearly the same initial temperature. In VHPLC high flow rates are achieved, producing fast analyses but requiring high inlet pressures. The combination of high flow rates and high inlet pressures generates local heat, leading to temperature changes in the column. Usually in this case a post-run time is input into the analytical method to allow the return of the column temperature to its initial state. An alternative strategy involves operating the column without a post-run equilibration period and maintaining constant temperature variations for subsequent analysis after conducting one or a few separations to bring the column to a reproducible starting temperature. A liquid chromatography instrument equipped with a pressure controller was used to perform constant pressure and constant flow rate VHPLC separations. Six replicate gradient separations of a nine component mixture consisting of acetophenone, propiophenone, butyrophenone, valerophenone, hexanophenone, heptanophenone, octanophenone, benzophenone, and acetanilide dissolved in water/acetonitrile (65:35, v/v) were performed under various experimental conditions: constant flow rate, two sets of constant pressure, and constant pressure operation with a programmed flow rate. The relative standard deviations of the response factors for all the analytes are lower than 5% across the methods. Programming the flow rate to maintain a fairly constant pressure instead of using instrument controlled constant pressure improves the reproducibility of the retention times by a factor of 5, when plotting the chromatograms in time.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Construction price forecasting is an essential component to facilitate decision-making for construction contractors, investors and related financial institutions. Construction economists are increasingly interested in seeking a more analytical method to forecast construction prices. Although many studies have focused on construction price modelling and forecasting, few have considered the impacts of large-scale economic events and seasonality. In this study, an advanced multivariate modelling technique, namely the vector correction (VEC) model with dummy variables, was employed. The impacts of global economic events and seasonality are factored into the model to forecast the construction price in the Australian construction market. Research findings suggest that both long-run and dynamic short-term causal relationships exist among the price and levels of supply and demand in the construction market. These relationships drive the construction price and supply and demand, which interact with one another as a loop system. The reliability of forecasting models was examined by the mean absolute percentage error (MAPE) and the Theil's inequality coefficient U tests. The test results suggest that the conventional VEC model and the VEC model with dummy variable are both acceptable for forecasting the construction price, while the VEC model considering external impacts achieves higher prediction accuracy than the conventional VEC model. © 2014 © 2014 Taylor & Francis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Applications of LSPR nano-particles in various areas of solar cells, LSPR biosensors, and SERS biosensors, based on interaction of light with noble metal nano-particles is increasing. Therefore, design and nano-fabrication of the LSPR devices is a key step in developing such applications. Design of nano-structures with desirable spectral properties using numerical techniques such as finite difference time domain (FDTD) is the first step in this work. A new structure called nano-sinusoid, satisfying the some desirable LSPR characteristics, is designed and simulated using the FDTD method. In the next stage, analytical method of electro static eigen mode method is used to validate the simulation results. The, nano-fabrications method of electron beam lithography (EBL) is implemented to fabricate the proposed profile with high precision. Finally, atomic force microscopy (AFM) is used to investigate the shape of the fabricated nano-particles, and the dark field microscopy is employed to demonstrate the particular spectral characteristics of the proposed nano-sinusoids.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A comparison between the elastic modulus of carbon nanotube (CNT) polymer nano composites predicted by classical micromechanics theories, based on continuum mechanics and experimental data, was made and the results revealed a great difference. To improve the accuracy of these models, a new two-step semi-analytical method was developed, which allowed consideration of the effect of the interphase, in addition to CNT and matrix, in the modeling of nanocomposites. Based on this developed method, the inuence of microstructural parameters, such as CNT volume fraction, CNT aspect ratio, partial and complete agglomerations of CNTs, and overlap and exfoliation of CNTs, on the overall elastic modulus of nanocomposites was investigated. ©2014 Sharif University of Technology. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A Teoria da Dependência surge nos anos 60 para repensar o modelo cepalino e oferecer uma alternativa de interpretação da dinâmica social da América Latina. Portadora de um método analítico mais sofisticado, ela suplantou com facilidade o estagnacionismo, que havia sido abraçado pelos remanescentes do nacional-desenvolvimentismo, e transformou-se na crítica mais consistente ao desenvolvimento autoritário. Esse estudo pretende reconstituir a crítica da dependência ao modelo econômico brasileiro de 1964 e 1984 e explicar sua dificuldade em elaborar um projeto alternativo para a sociedade brasileira. A Teoria da Dependência era apenas um método analítico ou continha um projeto de desenvolvimento alternativo ao modelo autoritário? Neste trabalho, os principais autores da teoria da dependência fazem hoje uma revisão crítica de suas idéias, de suas avaliações da gestão econômica do período militar e de suas propostas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Boal, Malvasia, Sercial and Verdelho are the main white grape varieties used in Madeira wine production. To estimate the free fraction of varietal aroma compounds of these varieties, 39 samples of musts were analysed to determine their content of monoterpenols and C13 norisoprenoids (terpenoids), using dynamic headspace solid-phase microextraction coupled with gas chromatography–mass spectrometry. The r-values for linearity studies of the analytical method used, varied between 0.977 (nerolidol) and 0.999 (linalool). The repeatability for each compound varied between 2.5% (citronellol) and 11.8% (β-ionone). The mean values from three vintages (1998, 1999 and 2000) confirmed that these musts have differentiated contents of terpenoids. In opposition to Verdelho musts, Malvasia showed the highest free terpenoids content. In order to establish relations between the compounds and the varieties under investigation, principal component analysis and linear discriminant analysis were applied to the data, revealing a good separation and classification power between the four groups as a function of varietal origin.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Non-invasive diagnostic strategies aimed at identifying biomarkers of cancer are of great interest for early cancer detection. Urine is potentially a rich source of volatile organic metabolites (VOMs) that can be used as potential cancer biomarkers. Our aim was to develop a generally reliable, rapid, sensitive, and robust analytical method for screening large numbers of urine samples, resulting in a broad spectrum of native VOMs, as a tool to evaluate the potential of these metabolites in the early diagnosis of cancer. METHODS: To investigate urinary volatile metabolites as potential cancer biomarkers, urine samples from 33 cancer patients (oncological group: 14 leukaemia, 12 colorectal and 7 lymphoma) and 21 healthy (control group, cancer-free) individuals were qualitatively and quantitatively analysed. Dynamic solid-phase microextraction in headspace mode (dHS-SPME) using a carboxenpolydimethylsiloxane (CAR/PDMS) sorbent in combination with GC-qMS-based metabolomics was applied to isolate and identify the volatile metabolites. This method provides a potential non-invasive method for early cancer diagnosis as a first approach. To fulfil this objective, three important dHS-SPME experimental parameters that influence extraction efficiency (fibre coating, extraction time and temperature of sampling) were optimised using a univariate optimisation design. The highest extraction efficiency was obtained when sampling was performed at 501C for 60min using samples with high ionic strengths (17% sodium chloride, wv 1) and under agitation. RESULTS: A total of 82 volatile metabolites belonging to distinct chemical classes were identified in the control and oncological groups. Benzene derivatives, terpenoids and phenols were the most common classes for the oncological group, whereas ketones and sulphur compounds were the main classes that were isolated from the urine headspace of healthy subjects. The results demonstrate that compound concentrations were dramatically different between cancer patients and healthy volunteers. The positive rates of 16 patients among the 82 identified were found to be statistically different (Po0.05). A significant increase in the peak area of 2-methyl3-phenyl-2-propenal, p-cymene, anisole, 4-methyl-phenol and 1,2-dihydro-1,1,6-trimethyl-naphthalene in cancer patients was observed. On average, statistically significant lower abundances of dimethyl disulphide were found in cancer patients. CONCLUSIONS: Gas chromatographic peak areas were submitted to multivariate analysis (principal component analysis and supervised linear discriminant analysis) to visualise clusters within cases and to detect the volatile metabolites that are able to differentiate cancer patients from healthy individuals. Very good discrimination within cancer groups and between cancer and control groups was achieved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Potengi river estuary is located in the region of Natal (RN, Brazil), comprising a population of approximately 1,000,000 inhabitants. Besides the dominant urban presence, the estuary has fragments of mangrove forest. The objective of this study is to determine the aliphatic hydrocarbons found in the bottom sediments of this estuary, identifying their levels, distribution and their possible origins through the diagnostic rates, indexes and results comparisons with the local anthropic and natural characteristics. The samples were obtained according to a plan that allowed sampling of the estuary up to 12 km upstream from it as mounth. 36 stations were selected, grouped into 12 cross sections through the course of the river and spaced on average by 1 km. Each section consisted of three stations: the right margin, the deepest point and the left margin. The hydrocarbon n-alkanes from C10 to C36, the isoprenoids pristane and phytane, the unresolved complex mixture (UCM) and the total resolved hydrocarbons were analyzed by gas chromatography. N-alkanes, pristane, phytane and UCM were detected only at some stations. In the other, the concentration was below the detection limit defined by the analytical method (0.1 mg / kg), preventing them from being analyzed to determine the origin of the material found. By using different parameters, the results show that the estuary receives both the input of petrogenic hydrocarbons, but also of biogenic hydrocarbons, featuring a mixture of sources and relatively impacted portions. Based on the characteristics and activities found in the region, it is possible to affirm that petrogenic sources related to oil products enter the estuary via urban runoff or boats traffic, boat washing and fueling. Turning to the biogenic source, the predominant origin was terrestrial, characterized by vascular plants, indicating contribution of mangrove vegetation. It was evident the presence of, at specific points in the estuary, hydrocarbon pollution, and, therefore is recommended the adoption of actions aimed at interrupting or, at least, mitigating the sources potentially capable of damp petrogenic hydrocarbons in the estuary studied.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The ethanol is the most overused psychoactive drug over the world; this fact makes it one of the main substances required in toxicological exams nowadays. The development of an analytical method, adaptation or implementation of a method known, involves a process of validation that estimates its efficiency in the laboratory routine and credibility of the method. The stability is defined as the ability of the sample of material to keep the initial value of a quantitative measure for a defined period within specific limits when stored under defined conditions. This study aimed to evaluate the method of Gas chromatography and study the stability of ethanol in blood samples, considering the variables time and temperature of storage, and the presence of preservative and, with that check if the conditions of conservation and storage used in this study maintain the quality of the sample and preserve the originally amount of analyte present. Blood samples were collected from 10 volunteers to evaluate the method and to study the stability of ethanol. For the evaluation of the method, part of the samples was added to known concentrations of ethanol. In the study of stability, the other side of the pool of blood was placed in two containers: one containing the preservative sodium fluoride 1% and the anticoagulant heparin and the other only heparin, was added ethanol at a concentration of 0.6 g/L, fractionated in two bottles, one being stored at 4ºC (refrigerator) and another at -20ºC (freezer), the tests were performed on the same day (time zero) and after 1, 3, 7, 14, 30 and 60 days of storage. The assessment found the difference in results during storage in relation to time zero. It used the technique of headspace associated with gas chromatography with the FID and capillary column with stationary phase of polyethylene. The best analysis of chromatographic conditions were: temperature of 50ºC (column), 150ºC (jet) and 250ºC (detector), with retention time for ethanol from 9.107 ± 0.026 and the tercbutanol (internal standard) of 8.170 ± 0.081 minutes, the ethanol being separated properly from acetaldehyde, acetone, methanol and 2-propanol, which are potential interfering in the determination of ethanol. The technique showed linearity in the concentration range of 0.01 and 3.2 g/L (0.8051 x + y = 0.6196; r2 = 0.999). The calibration curve showed the following equation of the line: y = x 0.7542 + 0.6545, with a linear correlation coefficient equal to 0.996. The average recovery was 100.2%, the coefficients of variation of accuracy and inter intra test showed values of up to 7.3%, the limit of detection and quantification was 0.01 g/L and showed coefficient of variation within the allowed. The analytical method evaluated in this study proved to be fast, efficient and practical, given the objective of this work satisfactorily. The study of stability has less than 20% difference in the response obtained under the conditions of storage and stipulated period, compared with the response obtained at time zero and at the significance level of 5%, no statistical difference in the concentration of ethanol was observed between analysis. The results reinforce the reliability of the method of gas chromatography and blood samples in search of ethanol, either in the toxicological, forensic, social or clinic