998 resultados para ZINC LOAD
Resumo:
A monostable multivibrator configuration using a new technique of regenerative feedback is discussed. This circuit provides an elegant alternative in situations wherein several monostable multivibrators have to be connected in tandem.
Resumo:
Exposure to hot environments affects milk yield (MY) and milk composition of pasture and feed-pad fed dairy cows in subtropical regions. This study was undertaken during summer to compare MY and physiology of cows exposed to six heat-load management treatments. Seventy-eight Holstein-Friesian cows were blocked by season of calving, parity, milk yield, BW, and milk protein (%) and milk fat (%) measured in 2 weeks prior to the start of the study. Within blocks, cows were randomly allocated to one of the following treatments: open-sided iron roofed day pen adjacent to dairy (CID) + sprinklers (SP); CID only; non-shaded pen adjacent to dairy + SP (NSD + SP); open-sided shade cloth roofed day pen adjacent to dairy (SCD); NSD + sprinkler (sprinkler on for 45 min at 1100 h if mean respiration rate >80 breaths per minute (NSD + WSP)); open-sided shade cloth roofed structure over feed bunk in paddock + 1 km walk to and from the dairy (SCP + WLK). Sprinklers for CID + SP and NSD + SP cycled 2 min on, 12 min off when ambient temperature >26°C. The highest milk yields were in the CID + SP and CID treatments (23.9 L cow−1 day−1), intermediate for NSD + SP, SCD and SCP + WLK (22.4 L cow−1 day−1), and lowest for NSD + WSP (21.3 L cow−1 day−1) (P < 0.05). The highest (P < 0.05) feed intakes occurred in the CID + SP and CID treatments while intake was lowest (P < 0.05) for NSD + WSP and SCP + WLK. Weather data were collected on site at 10-min intervals, and from these, THI was calculated. Nonlinear regression modelling of MY × THI and heat-load management treatment demonstrated that cows in CID + SP showed no decline in MY out to a THI break point value of 83.2, whereas the pooled MY of the other treatments declined when THI >80.7. A combination of iron roof shade plus water sprinkling throughout the day provided the most effective control of heat load.
Resumo:
Airport runway pavement always subjected to huge impact loading due to the hard landing of aircraft on the pavement surface. Therefore runway pavements should have sufficient impact resistance capability to avoid damage causing by hard impact like surface deflection in downward or penetration since the repair works is cumbersome within the operating condition of airport and also increases the service life cost of the pavement structure. Several research works have been carried out on airport runway pavement to measure the present condition of pavement and also to predict future performance of it. However, most of the works are confined by pavement response under moving aircraft loading. Nevertheless, no comprehensive research work is yet conducted to identify the controlling factors which might have significant effect in changing the common pavements damage like surface penetration depth under impact of aircraft. Therefore, a 3D FE study is conducted to determine some effective factors in controlling the top surface penetration depth of runway pavement. Among the exterior factors, mass of the impactor, velocity of the impactor, impact angle and boundary conditions are selected and as interior factors, thickness of the runway pavement, compressive strength and density of materials used in the runway pavement are selected.
Resumo:
In this paper a solution for the determination of stresses and displacements in a thick plate having a cylindrical hole subjected to localised hydrostatic loading has been given. Detail numerical results have been presented and compared with the results of an infinite hole subjected to localised hydrostatic load and a semiinfinite hole subjected to localised end load. It has been shown that for certain ratio of thickness of the pate to the radius of the hole and loading, the results could be obtained by using the solution of infinite or semiinfinite hole subjected to the same hydrostatic loading.
Resumo:
In the case of reinforced concrete slabs fixed at the boundaries, considerable enhancement in the load carrying capacity takes place due to compressive membrane action. In this paper a method is presented to analyse the effects of membrane action in fixed orthotropic circular slabs, carrying uniformly distributed loads. Depending on the radial moment capacity being greater or less than the circumferential moment capacity, two cases of orthotropy have been considered. Numerical results are worked out for certain assumed physical parameters and for different coefficients of orthotropy. Variations of load and bending moments with the central deflection are presented.
Resumo:
A method is presented for determining the complete load-deflection behavior of reinforced concrete skew slabs restrained at the edges and subjected to uniformly-distributed loading. The analysis is considered in three stages. In the first stage the load-deflection behavior up to the cracking load is considered. The behavior between the cracking load and the yield line load is considered in the second stage. The load-deflection behavior beyond the yield line load, taking into account the effect of the membrane action, is considered in the third stage. Details of an experimental program of casting and testing 12 reinforced concrete skew slabs restrained at the edges are presented to verify the results of the analysis.
Resumo:
Room-temperature zinc ion-conducting molten electrolytes based on acetamide, urea, and zinc perchlorate or zinc triflate have been prepared and characterized by various physicochemical, spectroscopic, and electrochemical techniques. The ternary molten electrolytes are easy to prepare and can be handled under ambient conditions. They show excellent stability, high ionic conductivity, relatively low viscosity, and other favorable physicochemical and electrochemical properties that make them good electrolytes for rechargeable zinc batteries. Specific conductivities of 3.4 and 0.5 mS cm(-1) at 25 degrees C are obtained for zinc-perchlorate-and zinc-triflate-containing melts, respectively. Vibrational spectroscopic data reveal that the free ion concentration is high in the optimized composition. Rechargeable Zn batteries have been assembled using the molten electrolytes, with gamma-MnO2 as the positive electrode and Zn as the negative electrode. They show excellent electrochemical characteristics with high discharge capacities. This study opens up the possibility of using acetamide-based molten electrolytes as alternate electrolytes in rechargeable zinc batteries. (C) 2009 The Electrochemical Society.
Resumo:
An analysis of the recently reported cDNA derived amino acid sequences of mouse (Kleene and Flynn, J. Biol. Chem. , 17272–17277, 1987) and rat (Luersson Image ,Nucl. Acids Res. Image , 3585, 1989). TP2 has revealed the presence of two potential zinc finger motifs involving cysteine and histidine residues. TP2, as purified from rat elongating spermatids, is shown here to contain 0.2 atoms of zinc bound per molecule of the protein by atomic absorption spectroscopy. On incubation with 10 μM ZnCl2, Image , and subsequent exhaustive dialysis, TP2 had 2 atoms of zinc bound per molecule. The involvement of cysteine residues of TP2 in coordination with zinc was also suggested by the observation that TP2 could be labeled, Image , with iodoacetamidofluorescein only after preincubation of spermatid nuclei with EDTA. The zinc finger domains of TP2 may play an important role in initiation of chromatin condensation and /or cessation of transcriptional activity during mammalian spermiogenesis. DTT, Dithiothreitol; IAF, Iodoacetamido-fluorescein; SDS, Sodium dodecyl sulfate; PAGE, Polyacrylamide gel electrophoresis; PMSF, Phynyl methyl sulfonyl fluoride
Resumo:
Lipped channel beams (LCBs) are commonly used as flexural members such as floor joists and bearers in the construction 6 industry. These thin-walled LCBs are subjected to specific buckling and failure modes, one of them being web crippling. Despite considerable 7 research in this area, some recent studies have shown that the current web crippling design rules are unable to predict the test capacities under 8 end-two-flange (ETF) and interior-two-flange (ITF) load conditions. In many instances, web crippling predictions by the available design 9 standards such as AISI S100, AS/NZS 4600 and Eurocode 3 Part 1-3 are inconsistent, i.e., unconservative in some cases, although they 10 are conservative in other cases. Hence, experimental studies consisting of 36 tests were conducted in this research to assess the web crippling 11 behavior and capacities of high-strength LCBs under two-flange load cases (ETF and ITF). Experimental results were then compared with the 12 predictions from current design rules. Comparison of the ultimate web crippling capacities from tests showed that the design equations are 13 very unconservative for LCB sections under the ETF load case and are conservative for the ITF load case. Hence, improved equations were 14 proposed to determine the web crippling capacities of LCBs based on the experimental results from this study. Current design equations do 15 not provide the direct strength method (DSM) provisions for web crippling. Hence, suitable design rules were also developed under the DSM 16 format using the test results and buckling analyses using finite-element analyses.
Resumo:
LiteSteel beam (LSB) is a hollow flange channel made from cold-formed steel using a patented manufacturing process involving simultaneous cold-forming and dual electric resistance welding. LSBs are currently used as floor joists and bearers in buildings. However, there are no appropriate design standards available due to its unique hollow flange geometry, residual stress characteristics and initial geometric imperfections arising from manufacturing processes. Recent research studies have focused on investigating the structural behaviour of LSBs under pure bending, predominant shear and combined actions. However, web crippling behaviour and strengths of LSBs still need to be examined. Therefore, an experimental study was undertaken to investigate the web crippling behaviour and strengths of LSBs under EOF (End One Flange) and IOF (Interior One Flange) load cases. A total of 23 web crippling tests were performed and the results were compared with the current AS/NZS 4600 and AISI S100 design standards, which showed that the cold-formed steel design rules predicted the web crippling capacity of LSB sections very conservatively under EOF and IOF load cases. Therefore, suitably improved design equations were proposed to determine the web crippling capacity of LSBs based on experimental results. In addition, new design equations were also developed under the Direct Strength Method format. This paper presents the details of this experimental study on the web crippling behaviour and strengths of LiteSteel beams under EOF and IOF load cases and the results.
Resumo:
Thin-walled steel hollow flange channel beams known as LiteSteel beam (LSB) sections were developed for use as joists and bearers in various flooring systems. However, they are subjected to specific buckling and failure modes, one of them being web crippling. Despite considerable research in this area, much of the current design predictions for cold-formed steel sections are not directly applicable to LSBs. This is due to the geometry of the LSB, which consists of two closed rectangular hollow flanges, and its unique residual stress characteristics and initial geometric imperfections. Hence an experimental study was conducted to investigate the web crippling behaviour and capacities of LSBs with their flanges fastened to supports. Thirty nine web crippling tests were conducted under two flange load cases (End Two Flange (ETF) and Interior Two Flange (ITF)). Test results showed that for ETF load case the web crippling capacities increased by 50% on average while they increased by 97% for ITF load case when flanges were fastened to supports. Comparison of the ultimate web crippling capacities from tests showed that AS/NZS 4600 and AISI S100 web crippling design equations are conservative for LSB sections with flanges fastened to supports under ETF and ITF load cases. Hence new equations were proposed to determine the web crippling capacities of LSBs with flanges fastened to supports. This paper presents the details of the experimental study into the web crippling behaviour of LSB sections with their flanges fastened under ETF and ITF load cases, and the results.
Resumo:
This paper presents the details of experimental and numerical studies on the web crippling behaviour of hollow flange channel beams, known as LiteSteel beams (LSB). The LSB has a unique shape of a channel beam with two rectangular hollow flanges, made using a unique manufacturing process. Experimental and numerical studies have been carried out to evaluate the behaviour and design of LSBs subject to pure bending actions, predominant shear actions and combined actions. To date, however, no investigation has been conducted into the web crippling behaviour and strength of LSB sections under ETF and ITF load conditions. Hence experimental studies consisting of 28 tests were first conducted in this research to assess the web crippling behaviour and strengths of LSBs under two flange load cases (ETF and ITF). Experimental web crippling capacity results were then compared with the predictions from AS/NZS 4600 and AISI S100 design rules, which showed that AS/NZS 4600 and AISI S100 design equations are very unconservative for LSBs under ETF and ITF load cases. Hence improved equations were proposed to determine the web crippling capacities of LSBs. Finite element models of the tested LSBs were then developed, and used to determine the elastic buckling loads of LSBs under ETF and ITF load cases. New equations were proposed to determine the corresponding elastic buckling coefficients of LSBs. Finally suitable design rules were also developed under the Direct Strength Method format using the test results and buckling analysis results from finite element analyses.
Resumo:
The rivet-fastened rectangular hollow flange channel beam (RHFCB) is a new cold-formed hollow section proposed as an alternative to welded hollow flange steel beams. To date, no investigation has been conducted on their web crippling behaviour and strengths. Hence an experimental study was conducted to investigate the web crippling behaviour and capacities of rivet fastened RHFCBs under End Two Flange (ETF) and Interior Two Flange (ITF) load cases. Experimental results showed that the current design rules are unconservative for rivet fastened RHFCB sections under ETF and ITF load cases. Hence new equations were proposed to determine the web crippling capacities of rivet fastened RHFCBs.