948 resultados para WAVE-FRONTS
Resumo:
In awake rats a single recurrent larger tidal volume (deep breaths) occurs at regular intervals, followed by oscillations in arterial pressure and heart rate. In the present study we recorded the changes in blood pressure, heart rate and ventilation during the wakefulness-sleep cycle identified by electrocorticographic records in order to determine whether the deep breaths and cardiovascular oscillations were associated with changes in the electrocorticogram. During several episodes of slow-wave sleep (SWS) in 7 rats the deep breaths and oscillations in arterial pressure and heart rate were preceded by SWS desynchronization. The interval between deep breaths during SWS was 71 ± 4 s, the period between initial desynchronization and the generation of deep breaths was 3.98 ± 0.45 s and the duration of SWS desynchronization was 11 ± 0.65 s. Hypotension (-16 ± 1 mmHg) and tachycardia (+15 ± 5 bpm) were observed during deep breaths in the SWS state. These data indicate that the oscillations in arterial pressure and heart rate during SWS are associated with deep breaths, which in turn are preceded by desynchronization of the electrocorticogram in this state of sleep
Resumo:
An assumption commonly made in the study of visual perception is that the lower the contrast threshold for a given stimulus, the more sensitive and selective will be the mechanism that processes it. On the basis of this consideration, we investigated contrast thresholds for two classes of stimuli: sine-wave gratings and radial frequency stimuli (i.e., j0 targets or stimuli modulated by spherical Bessel functions). Employing a suprathreshold summation method, we measured the selectivity of spatial and radial frequency filters using either sine-wave gratings or j0 target contrast profiles at either 1 or 4 cycles per degree of visual angle (cpd), as the test frequencies. Thus, in a forced-choice trial, observers chose between a background spatial (or radial) frequency alone and the given background stimulus plus the test frequency (1 or 4 cpd sine-wave grating or radial frequency). Contrary to our expectations, the results showed elevated thresholds (i.e., inhibition) for sine-wave gratings and decreased thresholds (i.e., summation) for radial frequencies when background and test frequencies were identical. This was true for both 1- and 4-cpd test frequencies. This finding suggests that sine-wave gratings and radial frequency stimuli are processed by different quasi-linear systems, one working at low luminance and contrast level (sine-wave gratings) and the other at high luminance and contrast levels (radial frequency stimuli). We think that this interpretation is consistent with distinct foveal only and foveal-parafoveal mechanisms involving striate and/or other higher visual areas (i.e., V2 and V4).
Resumo:
Marfan syndrome (MS) is a dominant autosomal disease caused by mutations in chromosome 15, the locus controlling fibrillin 1 synthesis, and may exhibit skeletal, ocular, cardiovascular, and other manifestations. Pulse wave velocity (PWV) is used to measure arterial elasticity and stiffness and is related to the elastic properties of the vascular wall. Since the practice of exercise is limited in MS patients, it was of interest to analyze the acute effect of submaximal exercise on aortic distensibility using PWV and other hemodynamic variables in patients with MS with either mild or no aortic dilatation. PWV and physiological variables were evaluated before and after submaximal exercise in 33 patients with MS and 18 controls. PWV was 8.51 ± 0.58 at rest and 9.10 ± 0.63 m/s at the end of exercise (P = 0.002) in the group with MS and 8.07 ± 0.35 and 8.98 ± 0.56 m/s in the control group, respectively (P = 0.004). Comparative group analysis regarding PWV at rest and at the end of exercise revealed no statistically significant differences. The same was true for the group that used β-blockers and the one that did not. The final heart rate was 10% higher in the control group than in the MS group (P = 0.01). Final systolic arterial pressure was higher in the control group (P = 0.02). PWV in MS patients with mild or no aortic dilatation did not differ from the control group after submaximal effort.
Resumo:
The present study was conducted to obtain reference values for brachial-ankle pulse wave velocity (baPWV) and to evaluate influencing factors of baPWV according to gender. Using automatic devices, baPWV was measured simultaneously in 2095 subjects. A total of 647 healthy subjects, none of whom presented atherosclerotic risk factors, were analyzed in the present study. Two different statistical methods were used to obtain reference values for baPWV according to subject gender and age. The association between baPWV value and gender, as well as other features, were analyzed. For male subjects, multiple stepwise analysis showed that age, systolic blood pressure (SBP), heart rate (HR), and plasma levels of triglycerides (TG) were independent predictors of baPWV. For female subjects, age, SBP, HR, and plasma levels of uric acid (UA) were independent predictors of baPWV. In male subjects, the upper limits of baPWV values were 1497.43/1425.00, 1518.67/1513.25, 1715.97/1726.50, 1925.20/1971.90, and 2310.18/2115.00 cm/s, obtained using two different statistical methods for the age ranges of 30-39, 40-49, 50-59, 60-69, and 70 and older, respectively. For females, the upper limits of baPWV values were 1426.70/1411.13, 1559.15/1498.95, 1733.50/1739.00, 1958.63/1973.78, and 2720.80/2577.00 cm/s for the age ranges of 30-39, 40-49, 50-59, 60-69, and 70 and older, respectively. Aging is the most important influencing factor for baPWV value and its effect is more prominent in females. The reference values of baPWV according to age and gender may be useful for the clinical diagnosis and preventive therapy of cardiovascular diseases.
Differential effects of aging on spatial contrast sensitivity to linear and polar sine-wave gratings
Resumo:
Changes in visual function beyond high-contrast acuity are known to take place during normal aging. We determined whether sensitivity to linear sine-wave gratings and to an elementary stimulus preferentially processed in extrastriate areas could be distinctively affected by aging. We measured spatial contrast sensitivity twice for concentric polar (Bessel) and vertical linear gratings of 0.6, 2.5, 5, and 20 cycles per degree (cpd) in two age groups (20-30 and 60-70 years). All participants were free of identifiable ocular disease and had normal or corrected-to-normal visual acuity. Participants were more sensitive to Cartesian than to polar gratings in all frequencies tested, and the younger adult group was more sensitive to all stimuli tested. Significant differences between sensitivities of the two groups were found for linear (only 20 cpd; P<0.01) and polar gratings (all frequencies tested; P<0.01). The young adult group was significantly more sensitive to linear than to circular gratings in the 20 cpd frequency. The older adult group was significantly more sensitive to linear than to circular gratings in all spatial frequencies, except in the 20 cpd frequency. The results suggest that sensitivity to the two kinds of stimuli is affected differently by aging. We suggest that neural changes in the aging brain are important determinants of this difference and discuss the results according to current models of human aging.
Resumo:
The aim of this study was to assess contrast sensitivity for angular frequency stimuli as well as for sine-wave gratings in adults under the effect of acute ingestion of alcohol. We measured the contrast sensitivity function (CSF) for gratings of 0.25, 1.25, 2.5, 4, 10, and 20 cycles per degree of visual angle (cpd) as well as for angular frequency stimuli of 1, 2, 4, 24, 48, and 96 cycles/360°. Twenty adults free of ocular diseases, with normal or corrected-to-normal visual acuity, and no history of alcoholism were enrolled in two experimental groups: 1) no alcohol intake (control group) and 2) alcohol ingestion (experimental group). The average concentration of alcohol in the experimental group was set to about 0.08%. We used a paradigm involving a forced-choice method. Maximum sensitivity to contrast for sine-wave gratings in the two groups occurred at 4 cpd sine-wave gratings and at 24 and 48 cycles/360° for angular frequency stimuli. Significant changes in contrast sensitivity were observed after alcohol intake compared with the control condition at spatial frequency of 4 cpd and 1, 24, and 48 cycles/360° for angular frequency stimuli. Alcohol intake seems to affect the processing of sine-wave gratings at maximum sensitivity and at the low and high frequency ends for angular frequency stimuli, both under photopic luminance conditions.
Resumo:
Accumulating evidence has suggested that high salt and potassium might be associated with vascular function. The aim of this study was to investigate the effect of salt intake and potassium supplementation on brachial-ankle pulse wave velocity (PWV) in Chinese subjects. Forty-nine subjects (28-65 years of age) were selected from a rural community of northern China. All subjects were sequentially maintained on a low-salt diet for 7 days (3.0 g/day NaCl), a high-salt diet for an additional 7 days (18.0 g/day NaCl), and a high-salt diet with potassium supplementation for a final 7 days (18.0 g/day NaCl+4.5 g/day KCl). Brachial-ankle PWV was measured at baseline and on the last day of each intervention. Blood pressure levels were significantly increased from the low-salt to high-salt diet, and decreased from the high-salt diet to high-salt plus potassium supplementation. Baseline brachial-ankle PWV in salt-sensitive subjects was significantly higher than in salt-resistant subjects. There was no significant change in brachial-ankle PWV among the 3 intervention periods in salt-sensitive, salt-resistant, or total subjects. No significant correlations were found between brachial-ankle PWV and 24-h sodium and potassium excretions. Our study indicates that dietary salt intake and potassium supplementation, at least in the short term, had no significant effect on brachial-ankle PWV in Chinese subjects.
Resumo:
This thesis, based on the results of an organizational ethnography of a university-based feminist organization in Southern Ontario (the Centre), traces how third wave feminism is being constituted in the goals, initiatives, mandate, organizational structure, and overall culture of university-based feminist organizations. I argue that, from its inception, the meanings and goals of the Centre have been contested through internal critique, reflection, and discussion inspired by significant shifts in feminist theory that challenge the fundamental principles of second wave feminism. I identify a major shift in the development and direction of the Centre that occurs in two distinct phases. The first phase of the shift occurs with the emergence of an antioppression framework, which broadens the Centre's mandate beyond gender and sexism to consider multiple axes of identity and oppression that affect women's lives. The second phase of this shift is characterized by a focus on (trans) inclusion and accessibility and has involved changing the Centre's name so that it is no longer identified as a women's centre in order to reflect more accurately its focus on mUltiple axes of identity and oppression. Along with identifying two phases of a major shift in the direction of the Centre, I trace two discourses about its development. The dominant discourse of the Centre's development is one of progress and evolution. The dominant discourse characterizes the Centre as a dynamic feminist organization that consistently strives to be more inclusive and diverse. The reverse discourse undermines the dominant discourse by emphasizing that, despite the Centre's official attempts to be inclusive and to build diversity, little has actually changed, leaving women of colour marginalized in the Centre's dominant culture of whiteness. This research reveals that, while many of their strategies have unintended (negative) consequences, members of the Centre are working to build an inclusive politics of resistance that avoids the mistakes of earlier feminist movements and organizations. These members, along with other activists, actively constitute third wave feminism in a process that is challenging, contradictory, and often painful. A critical analysis of this process and the strategies it involves provides an opportunity for activists to reflect on their experiences and develop new strategies in an effort to further struggles for social justice and equity.
Resumo:
High temperature superconductors were discovered in 1986, but despite considerable research efforts, both experimental and theoretical, these materials remain poorly understood. Because their electronic structure is both inhomogeneous and highly correlated, a full understanding will require knowledge of quasiparticle properties both in real space and momentum space. In this thesis, we will present a theoretical analysis of the scanning tunneling microscopy (STM) data in BSCCO. We introduce the Bogoliubov-De Gennes Hamiltonian and solve it numerically on a two-dimensional 20 x 20 lattice under a magnetic field perpendicular to the surface. We consider a vortex at the center of our model. We introduce a Zn impurity in our lattice as a microscopic probe of the physical properties of BSCCO. By direct numerical diagonalization of the lattice BogoliubovDe Gennes Hamiltonian for different positions of the impurity, we can calculate the interaction between the vortex and the impurity in a d-wave superconductor.
Resumo:
Methods for both partial and full optimization of wavefunction parameters are explored, and these are applied to the LiH molecule. A partial optimization can be easily performed with little difficulty. But to perform a full optimization we must avoid a wrong minimum, and deal with linear-dependency, time step-dependency and ensemble-dependency problems. Five basis sets are examined. The optimized wavefunction with a 3-function set gives a variational energy of -7.998 + 0.005 a.u., which is comparable to that (-7.990 + 0.003) 1 of Reynold's unoptimized \fin ( a double-~ set of eight functions). The optimized wavefunction with a double~ plus 3dz2 set gives ari energy of -8.052 + 0.003 a.u., which is comparable with the fixed-node energy (-8.059 + 0.004)1 of the \fin. The optimized double-~ function itself gives an energy of -8.049 + 0.002 a.u. Each number above was obtained on a Bourrghs 7900 mainframe computer with 14 -15 hrs CPU time.
Resumo:
Cardiovascular disease is a leading cause of mortality in the spinal cord injured (SCI) population. Reduced arterial compliance is a cardiovascular risk factor and whole body vibration (WBV) has be en shown to improve arterial compliance in able-bodied individuals. The study investigated the effect of an acute session ofWBV on arterial compliance as measured by pulse wave velocity (PWV). On separate days, arm, leg and aortic PWV were measured pre- and post- a 45 minute session of passive stance (PS) and WBV. The WBV was intermittent with a set frequency of 45Hz and amplitude of O.6mm. There was no condition by time effect when comparing PWV after WBV and PS. Following WBV, aortic (928.6±127.7 vs. 901.1±96.6cm/sec), leg (1035.2±113.8 vs.l099.8±114.2cm/sec) and arm PWV (1118.9±119.8 vs. 1181.1±124.4cm/s) did not change. As such, WBV did not reduce arterial compliance, however future research with protocol modifications is recommended.
Resumo:
In this paper we study the extended Tanh method to obtain some exact solutions of KdV-Burgers equation. The principle of the Tanh method has been explained and then apply to the nonlinear KdV- Burgers evolution equation. A finnite power series in tanh is considered as an ansatz and the symbolic computational system is used to obtain solution of that nonlinear evolution equation. The obtained solutions are all travelling wave solutions.
Resumo:
Fermi patches in quasi-two dimensional charge density waves (CDW) have not described the connection to superconductivity (SC) according to theory adequately at this point in time. The connection between CDW and SC in the quasi-two dimensional material CuxTiSe2 is an interesting one which might reveal mechanisms in unconventional superconductors. A previous Brock graduate student grew crystals of CuxTiSe2. The precise doping of the samples was not known. In order to determine the doping parameter x in CuxTiSe2, a sensitive resistivity measurement system was necessary. A new resistivity measurement system was designed and implemented utilizing an Infrared Labs HDL-10 He3 cryostat. By comparing with data from the literature, doping of two samples was investigated using the new measurement system and a Quantum Design Magnetic Property Measurement System (MPMS). Methods for determining the doping revealed that the old resistivity system would not be able to determine the CDW transition temperature of highly doped samples or doping for elongated samples due to electronic noise. Doping in one sample was found to be between x=0.06 and x=0.065. Values of doping in the second sample had a discrepancy but could be explained by incorrect sample orientation.
Resumo:
INTRODUCTION : Les soins de première ligne au Québec vivent depuis quelques années une réorganisation importante. Les GMF, les cliniques réseaux, les CSSS, les réseaux locaux de service, ne sont que quelques exemples des nouveaux modes d’organisation qui voient le jour actuellement. La collaboration interprofessionnelle se trouve au cœur de ces changements. MÉTHODOLOGIE : Il s’agit d’une étude de cas unique, effectuée dans un GMF de deuxième vague. Les données ont été recueillies par des entrevues semi-dirigées auprès du médecin responsable du GMF, des médecins et des infirmières du GMF, et du cadre responsable des infirmières au CSSS. Les entrevues se sont déroulées jusqu’à saturation empirique. Des documents concernant les outils cliniques et les outils de communication ont aussi été consultés. RÉSULTATS : À travers un processus itératif touchant les éléments interactionnels et organisationnels, par l’évolution vers une culture différente, des ajustements mutuels ont pu être réalisés et les pratiques cliniques se sont réellement modifiées au sein du GMF étudié. Les participants ont souligné une amélioration de leurs résultats cliniques. Ils constatent que les patients ont une meilleure accessibilité, mais l’effet sur la charge de travail et sur la capacité de suivre plus de patients est évaluée de façon variable. CONCLUSION : Le modèle conceptuel proposé permet d’observer empiriquement les dimensions qui font ressortir la valeur ajoutée du développement de la collaboration interprofessionnelle au sein des GMF, ainsi que son impact sur les pratiques professionnelles.
Resumo:
Les diagnostics cliniques des maladies cardio-vasculaires sont principalement effectués à l’aide d’échographies Doppler-couleur malgré ses restrictions : mesures de vélocité dépendantes de l’angle ainsi qu’une fréquence d’images plus faible à cause de focalisation traditionnelle. Deux études, utilisant des approches différentes, adressent ces restrictions en utilisant l’imagerie à onde-plane, post-traitée avec des méthodes de délai et sommation et d’autocorrélation. L’objectif de la présente étude est de ré-implémenté ces méthodes pour analyser certains paramètres qui affecte la précision des estimations de la vélocité du flux sanguin en utilisant le Doppler vectoriel 2D. À l’aide d’expériences in vitro sur des flux paraboliques stationnaires effectuées avec un système Verasonics, l’impact de quatre paramètres sur la précision de la cartographie a été évalué : le nombre d’inclinaisons par orientation, la longueur d’ensemble pour les images à orientation unique, le nombre de cycles par pulsation, ainsi que l’angle de l’orientation pour différents flux. Les valeurs optimales sont de 7 inclinaisons par orientation, une orientation de ±15° avec 6 cycles par pulsation. La précision de la reconstruction est comparable à l’échographie Doppler conventionnelle, tout en ayant une fréquence d’image 10 à 20 fois supérieure, permettant une meilleure caractérisation des transitions rapides qui requiert une résolution temporelle élevée.