970 resultados para Unit testing
Resumo:
This paper presents a single precision floating point arithmetic unit with support for multiplication, addition, fused multiply-add, reciprocal, square-root and inverse squareroot with high-performance and low resource usage. The design uses a piecewise 2nd order polynomial approximation to implement reciprocal, square-root and inverse square-root. The unit can be configured with any number of operations and is capable to calculate any function with a throughput of one operation per cycle. The floatingpoint multiplier of the unit is also used to implement the polynomial approximation and the fused multiply-add operation. We have compared our implementation with other state-of-the-art proposals, including the Xilinx Core-Gen operators, and conclude that the approach has a high relative performance/area efficiency. © 2014 Technical University of Munich (TUM).
Resumo:
In this work, an experimental study was performed on the influence of plug-filling, loading rate and temperature on the tensile strength of single-strap (SS) and double-strap (DS) repairs on aluminium structures. Whilst the main purpose of this work was to evaluate the feasibility of plug-filling for the strength improvement of these repairs, a parallel study was carried out to assess the sensitivity of the adhesive to external features that can affect the repairs performance, such as the rate of loading and environmental temperature. The experimental programme included repairs with different values of overlap length (L O = 10, 20 and 30 mm), and with and without plug-filling, whose results were interpreted in light of experimental evidence of the fracture modes and typical stress distributions for bonded repairs. The influence of the testing speed on the repairs strength was also addressed (considering 0.5, 5 and 25 mm/min). Accounting for the temperature effects, tests were carried out at room temperature (≈23°C), 50 and 80°C. This permitted a comparative evaluation of the adhesive tested below and above the glass transition temperature (T g), established by the manufacturer as 67°C. The combined influence of these two parameters on the repairs strength was also analysed. According to the results obtained from this work, design guidelines for repairing aluminium structures were
Resumo:
OBJECTIVE Determine the coverage rate of syphilis testing during prenatal care and the prevalence of syphilis in pregnant women in Brazil. METHODS This is a national hospital-based cohort study conducted in Brazil with 23,894 postpartum women between 2011 and 2012. Data were obtained using interviews with postpartum women, hospital records, and prenatal care cards. All postpartum women with a reactive serological test result recorded in the prenatal care card or syphilis diagnosis during hospitalization for childbirth were considered cases of syphilis in pregnancy. The Chi-square test was used for determining the disease prevalence and testing coverage rate by region of residence, self-reported skin color, maternal age, and type of prenatal and child delivery care units. RESULTS Prenatal care covered 98.7% postpartum women. Syphilis testing coverage rate was 89.1% (one test) and 41.2% (two tests), and syphilis prevalence in pregnancy was 1.02% (95%CI 0.84;1.25). A lower prenatal coverage rate was observed among women in the North region, indigenous women, those with less education, and those who received prenatal care in public health care units. A lower testing coverage rate was observed among residents in the North, Northeast, and Midwest regions, among younger and non-white skin-color women, among those with lower education, and those who received prenatal care in public health care units. An increased prevalence of syphilis was observed among women with < 8 years of education (1.74%), who self-reported as black (1.8%) or mixed (1.2%), those who did not receive prenatal care (2.5%), and those attending public (1.37%) or mixed (0.93%) health care units. CONCLUSIONS The estimated prevalence of syphilis in pregnancy was similar to that reported in the last sentinel surveillance study conducted in 2006. There was an improvement in prenatal care and testing coverage rate, and the goals suggested by the World Health Organization were achieved in two regions. Regional and social inequalities in access to health care units, coupled with other gaps in health assistance, have led to the persistence of congenital syphilis as a major public health problem in Brazil.
Impact of a price-maker pumped storage hydro unit on the integration of wind energy in power systems
Resumo:
The increasing integration of larger amounts of wind energy into power systems raises important operational issues, such as the balance between power generation and demand. The pumped storage hydro (PSH) units are one possible solution to mitigate this problem, once they can store the excess of energy in the periods of higher generation and lower demand. However, the behaviour of a PSH unit may differ considerably from the expected in terms of wind power integration when it operates in a liberalized electricity market under a price-maker context. In this regard, this paper models and computes the optimal PSH weekly scheduling in a price-taker and price-maker scenarios, either when the PSH unit operates in standalone and integrated in a portfolio of other generation assets. Results show that the price-maker standalone PSH will integrate less wind power in comparison with the price-taker situation. Moreover, when the PSH unit is integrated in a portfolio with a base load power plant, the role of the price elasticity of demand may completely change the operational profile of the PSH unit. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
This paper proposes a stochastic mixed-integer linear approach to deal with a short-term unit commitment problem with uncertainty on a deregulated electricity market that includes day-ahead bidding and bilateral contracts. The proposed approach considers the typically operation constraints on the thermal units and a spinning reserve. The uncertainty is due to the electricity prices, which are modeled by a scenario set, allowing an acceptable computation. Moreover, emission allowances are considered in a manner to allow for the consideration of environmental constraints. A case study to illustrate the usefulness of the proposed approach is presented and an assessment of the cost for the spinning reserve is obtained by a comparison between the situation with and without spinning reserve.
Resumo:
Dissertação apresentada para obtenção do Grau de Doutor em Matemática, Estatística, pela Universidade Nova de Lisboa, faculdade de Ciências e Tecnologia
Resumo:
The Brazilian National Regulatory Agency for Private Health Insurance and Plans has recently published a technical note defining the criteria for the coverage of genetic testing to diagnose hereditary cancer. In this study we show the case of a patient with a breast lesion and an extensive history of cancer referred to a private service of genetic counseling. The patient met both criteria for hereditary breast and colorectal cancer syndrome screening. Her private insurance denied coverage for genetic testing because she lacks current or previous cancer diagnosis. After she appealed by lawsuit, the court was favorable and the test was performed using next-generation sequencing. A deletion of MLH1 exon 8 was found. We highlight the importance to offer genetic testing using multigene analysis for noncancer patients.
Resumo:
The main goals of the present work are the evaluation of the influence of several variables and test parameters on the melt flow index (MFI) of thermoplastics, and the determination of the uncertainty associated with the measurements. To evaluate the influence of test parameters on the measurement of MFI the design of experiments (DOE) approach has been used. The uncertainty has been calculated using a "bottom-up" approach given in the "Guide to the Expression of the Uncertainty of Measurement" (GUM). Since an analytical expression relating the output response (MFI) with input parameters does not exist, it has been necessary to build mathematical models by adjusting the experimental observations of the response variable in accordance with each input parameter. Subsequently, the determination of the uncertainty associated with the measurement of MFI has been performed by applying the law of propagation of uncertainty to the values of uncertainty of the input parameters. Finally, the activation energy (Ea) of the melt flow at around 200 degrees C and the respective uncertainty have also been determined.
Resumo:
The integration of large amounts of wind energy in power systems raises important operation issues such as the balance between power demand and generation. The pumped storage hydro (PSH) units are seen as one solution for this issue, avoiding the need for wind power curtailments. However, the behavior of a PSH unit might differ considerably when it operates in a liberalized market with some degree of market power. In this regard, a new approach for the optimal daily scheduling of a PSH unit in the day-ahead electricity market was developed and presented in this paper, in which the market power is modeled by a residual inverse demand function with a variable elasticity. The results obtained show that increasing degrees of market power of the PSH unit correspond to decreasing levels of storage and, therefore, the capacity to integrate wind power is considerably reduced under these circumstances.
Resumo:
Dissertation submitted in partial fulfilment of the requirements for the Degree of Master of Science in Geospatial Technologies
Resumo:
To boost logic density and reduce per unit power consumption SRAM-based FPGAs manufacturers adopted nanometric technologies. However, this technology is highly vulnerable to radiation-induced faults, which affect values stored in memory cells, and to manufacturing imperfections. Fault tolerant implementations, based on Triple Modular Redundancy (TMR) infrastructures, help to keep the correct operation of the circuit. However, TMR is not sufficient to guarantee the safe operation of a circuit. Other issues like module placement, the effects of multi- bit upsets (MBU) or fault accumulation, have also to be addressed. In case of a fault occurrence the correct operation of the affected module must be restored and/or the current state of the circuit coherently re-established. A solution that enables the autonomous restoration of the functional definition of the affected module, avoiding fault accumulation, re-establishing the correct circuit state in real-time, while keeping the normal operation of the circuit, is presented in this paper.
Resumo:
Second International Workshop on Analog and Mixed Signal Integrated Circuits for Space Applications (AMICSA 2008), Sintra, Portugal, Setembro de 2008
Resumo:
Risk assessment is one of the main pillars of the framework directive and other directives in respect of health and safety. It is also the basis of an effective management of safety and health as it is essential to reduce work-related accidents and occupational diseases. To survey the hazards eventually present in the workplaces the usual procedures are i) gathering information about tasks/activities, employees, equipment, legislation and standards; ii) observation of the tasks and; iii) quantification of respective risks through the most adequate risk assessment among the methodologies available. From this preliminary evaluation of a welding plant and, from the different measurable parameters, noise was considered the most critical. This paper focus not only the usual way of risk assessment for noise but also another approach that may allow us to identify the technique with which a weld is being performed.
Resumo:
Several reports have related Legionella pneumophila with pneumonia in renal transplant patients, however this association has not been systematically documented in Brazil. Therefore this paper reports the incidence, by serologycal assays, of Legionella pneumophila serogroup 1 in these patients during a five year period. For this purpose sera from blood samples of 70 hospitalized patients with pneumonia from the Renal Transplant Unit of Hospital das Clinicas, FMUSP collected at the acute and convalescent phase of infection were submitted to indirect immunofluorescence assay (IFA) to demonstrate anti-Legionella pneumophila serogroup 1 antibodies. Of these 70 patients studied during the period of 1988 to 1993,18 (25.71 %) had significant rises in specific antibody titers for Legionella pneumophila serogroup 1. Incidence was interrupted following Hospital water decontamination procedures, with recurrence of infections after treatment interruption. In this study, the high susceptibility (25.71%) of immunodepressed renal transplant patients to Legionella pneumophila serogroup 1 nosocomial infections is documented. The importance of the implementation and maintenance of water decontamination measures for prophylaxis of the infection is also clearly evident.
Resumo:
A candidin, which is a suspension of killed yeast cells, is commonly used for intradermal tests of delayed hypersensitivity, to evaluate the immunological cellular competence of the patient, when the test is applied along with other similar tests. When working with a cellular antigen, the histopathology of positive skin tests reveals a cellular infiltrate which not only presents a characteristic hypersensitivity reaction but also a neutrophilic abscess in the central part. This research presents the results of a comparison between the yeast cell suspension and the polysaccharide antigens, both obtained from the same strains of Candida albicans. The results obtained by skin tests in one hundred individuals were 61.0% with the polysaccharide antigen and 69.0% with the yeast cell suspension antigen. Concordant results concerning the two antigens were observed in 82.0% of the individuals. The discussion section presents an assumption to explain the differences of positivity obtained with the two antigens. We conclude that the polysaccharide antigen can be utilized in the intradermal test of delayed hypersensitivity to Candida albicans.