974 resultados para Type-16


Relevância:

30.00% 30.00%

Publicador:

Resumo:

To identify early metabolic abnormalities in type 2 diabetes mellitus, we measured insulin secretion, sensitivity to insulin, and hepatic insulin extraction in 48 healthy normal glucose-tolerant Brazilians, first-degree relatives of type 2 diabetic patients (FH+). Each individual was matched for sex, age, weight, and body fat distribution with a person without history of type 2 diabetes (FH-). Both groups were submitted to a hyperglycemic clamp procedure (180 mg/dl). Insulin release was evaluated in its two phases. The first was calculated as the sum of plasma insulin at 2.5, 5.0, 7.5, and 10.0 min after the beginning of glucose infusion, and the second as the mean plasma insulin level in the third hour of the clamp procedure. Insulin sensitivity index (ISI) was the mean glucose infusion rate in the third hour of the clamp experiment divided by the mean plasma insulin concentration during the same period of time. Hepatic insulin extraction was determined under fasting conditions and in the third hour of the clamp procedure as the ratio between C-peptide and plasma insulin levels. FH+ individuals did not differ from FH- individuals in terms of the following parameters [median (range)]: a) first-phase insulin secretion, 174 (116-221) vs 207 (108-277) µU/ml, b) second-phase insulin secretion, 64 (41-86) vs 53 (37-83) µU/ml, and c) ISI, 14.8 (9.0-20.8) vs 16.8 (9.0-27.0) mg kg-1 min-1/µU ml-1. Hepatic insulin extraction in FH+ subjects was similar to that of FH- ones at basal conditions (median, 0.27 vs 0.27 ng/µU) and during glucose infusion (0.15 vs 0.15 ng/µU). Normal glucose-tolerant Brazilian FH+ individuals well-matched with FH- ones did not show defects of insulin secretion, insulin sensitivity, or hepatic insulin extraction as tested by hyperglycemic clamp procedures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thoracic radiography of a 3-month-old, female Chinese Shar-pei revealed an esophageal hiatal hernia with stomach, liver, and small intestine displaced into the thorax. Three days after the surgical correction, the dog developed ileal intussusception and was reoperated. Recovery was uncomplicated and the dog was asymptomatic 16 months after surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the present study was to determine the influence of the type of trauma on the pulp vitality and the time elapsed until seeking dental care in children aged 0-3 years seen at the Baby Clinic of the Aracatuba Dental School, UNESP. A total of 1813 records were analyzed. Two hundred and three patients, corresponding to 302 traumatized teeth, were assessed clinically and radiographically. Hard-tissue injuries were the most frequent (52%), with a predominance of enamel crown fractures (41.4%), followed by concussions (12.6%) and intrusions (11.6%). Clinical and radiographic examination revealed that 72% of the traumatized teeth maintained pulp vitality. In the case of supporting-tissue lesions, 51.1% of the patients sought care within 1-15 days after injury, while in the case of hard-tissue injuries, 52.7% sought care only after 16 days. The results showed that supporting-tissue injuries had a significant influence on the faster seeking of dental care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Context. The V-type asteroids are associated with basaltic composition. Apart from ( 1459) Magnya, an asteroid that is clearly dynamically and mineralogically unconnected to the Vesta family, all currently known V-type asteroids are either members of the Vesta family, or are hypothesized to be former members of the dynamical family that migrated to their current orbital positions. The recent identification of ( 21238) 1995 WV7 as a V-type asteroid introduces the possibility that a second basaltic asteroid not connected with the Vesta family exists. This asteroid is on the opposite side of the 3: 1 mean motion resonance with respect to Vesta, and it would be very unlikely that a member of the Vesta family of its size (D > 5km) migrating via either the Yarkovsky effect or repeated close encounters with Vesta survived the passage through such a resonance.Aims. In this work we investigate the possibility that ( 21238) 1995 WV7 originated as a fragment of the parent body of the Eunomia family and then migrated via the interplay of the Yarkovsky effect and some powerful nonlinear secular resonances, such as the (s - s(6)) - ( g(5) - g(6)). If (15) Eunomia is, as claimed, a differentiated object whose originally pyroxene-enriched crust layer was lost in a collision that either created the Eunomia family or preceded its formation, can (21238) be a fragment of its long-lost basaltic crust that migrated to the current position?Methods. We mapped the phase space around (21238) and determined which of the nonlinear secular resonances that we identified are stronger and more capable of having caused the current difference in proper i between (21238) and members of the Eunomia family. We simulated the Yarkovsky effect by using the SWIFT-RMVSY integrator.Results. Our results suggest that it is possible to migrate from the Eunomia dynamical family to the current orbital location of ( 21238) via the interplay of the Yarkovsky effect and the (s - s6) - (g5 - g6) nonlinear secular resonance, on time-scales of at least 2.6 Gyr.Conclusions. (15) Eunomia might be the third currently known parent body for V-type asteroids.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we examine the nonlinear control method based on the saturation phenomenon and of systems coupled with quadratic nonlinear ties applied to a shear-building portal plane frame foundation that supports an unbalanced direct cut-rent with limited power supply (non-ideal system). We analyze the equations of motion by using the method of averaging and numerical simulation. The interaction of the non-ideal structure with the saturation controller may lead to the occurrence of interesting phenomena during the forward passage through the several resonance states of the systems. Special attention is focused on passage through resonance when the non-ideal excitation frequency is near the portal frame natural frequency and when the non-ideal system frequency is approximately twice the controller frequency (two-to-one internal resonance).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dynamical systems of the billiard type are of fundamental importance for the description of numerous phenomena observed in many different fields of research, including statistical mechanics, Hamiltonian dynamics, nonlinear physics, and many others. This Focus Issue presents the recent progress in this area with contributions from the mathematical as well as physical stand point. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4730155]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A potentiometric sensor constructed from a mixture of 25% (m/m) spinel-type manganese oxide (lambda-MnO2), 50% (m/m) graphite powder and 25% (m/m) mineral oil is used for the determination of lithium ions in a flow injection analysis system. Experimental parameters, such as pH of the carrier solution, flow rate, injection sample volume, and selectivity for Li+ against other alkali and alkaline-earth ions and the response time of this sensor were investigated. The sensor response to lithium ions was linear in the concentration range 8.6 x 10(-5) - 1.0 x 10(-2) mol L-1 with a slope 78.9 +/- 0.3 mV dec(-1) over a wide pH range 7 - 10 (Tris buffer), without interference of other alkali and alkaline-earth metals. For a flow rate of 5.0 mL min(-1) and a injection sample volume of 408.6 muL, the relative standard deviation for repeated injections of a 5.0 x 10(-4) mol L-1 lithium ions was 0.3%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A relativistic treatment of the deuteron and its observables based on a two-body Dirac (Breit) equation, with phenomenological interactions, associated to one-boson exchanges with cutoff masses, is presented. The 16-component wave function for the deuteron (J(pi) = 1+) solution contains four independent radial functions which obey a system of four coupled differential equations of first order. This radial system is numerically integrated, from infinity to the origin, by fixing the value of the deuteron binding energy and using appropriate boundary conditions at infinity. Specific examples of mixtures containing scalar, pseudoscalar and vector like terms are discussed in some detail and several observables of the deuteron are calculated. Our treatment differs from more conventional ones in that nonrelativistic reductions of the order c-2 are not used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

5-azacytidine (5-azaC) treatment combined with cytosine arabinoside (ara-C) or caffeine were performed in vitro in Chinese hamster cells, CHO-K1 (wild-type) and xrs-5 (mutant) cell lines, in order to compare the cell response to the induction of chromosomal aberrations. Exponentially growing cells were treated with 5-azaC (4-16 uM) for 1 h, the cells were washed and incubated for 7 h, and 500 uM caffeine or 5 uM ara-C were added to the cultures for the last 2 h. In both cell lines, 5-azaC induced a significantly increase (P<0.01) in the frequencies of aberrations; in the combined treatments (5-azaC + Ara-C), a significant reduction (P<0.05) was observed for the aberrations which were randomly distributed. Caffeine had no influence at the same conditions. 5-azaC induced-DNA lesions were probably processed at S/G2 phase in a common pathway in both cell lines, but alternatively, 5-azaC may cause xrs-5 cells to revert to the wild-type.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of the brush type as a earner of priming adhesive solutions and the use of paper points as a remover of the excess of these solutions on the push-out bond strength of resin cement to bovine root dentin. The null hypotheses were that brush type and the use of paper points do not affect the bond strength. Materials and Methods: The canals of 80 single-root bovine roots (16 mm in length) were prepared at 12 mm using the preparation drill (FRC Postec Plus, Ivoclar). Half of each root was embedded in acrylic resin and the specimens were divided into 8 groups, considering the factors brush type (4 levels) and paper point (2 levels) (n = 10): Gr 1: small microbrush (Cavi-Tip, SDI); Gr 2: Microbrush (Dentsply); Gr 3: Endobrush (Bisco); Gr 4: conventional brush (Bisco); Gr 5: Cavi-Tip (SDI) + paper points; Gr 6: Microbrush (Dentsply) + paper points; Gr 7: Endobrush (Bisco) + paper points; Gr 8: conventional brush (Bisco) + paper points. The root dentin was treated with a multistep total-etch adhesive system (All Bond 2). The adhesive system was applied using each microbrush, with and without using paper points. One fiber post was molded with addition silicon and 80 posts were made of resin cement (Duolink), The resin posts were luted (Duolink resin cement), and the specimens were stored for 24 h in water at 37°C. Each specimen was cut into 4 disk-shaped samples (1.8 mm in thickness), which were submitted to the push-out test. Results: The brush type (p < 0.0001) (small microbrush > microbrush = endobrush = conventional brush) and the use of paper points (p = 0.0001) (with > without) influenced the bond strength significantly (two-way ANOVA). The null hypotheses were rejected. Conclusion: The smallest brush (Cavi-Tip) and the use of paper points significantly improved the resin bond to bovine root dentin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper by R. E. Catai, E. C. Bianchi, P. R de Águia and M. C. Alves reports on the results of an analysis made of roundness errors, residual stresses, and SEM micrographs of VC131 steel. The analysis involved workpieces ground with two types of cutting fluid: synthetic cutting fluid and emulsive oil. In this study, the cutting parameters were kept constant while the type of cutting fluid was varied. The amount of cutting fluid injected in the process was also varied, aiming to identify the ideal amount required to obtain good results without causing structural damage to the workpiece. The SEM analyses of roundness errors and residual stresses revealed that, of the two cutting fluids, emulsive oil provided better tensions due to its greater lubricating power.