616 resultados para Titanium alloy
Resumo:
Monte Carlo calculations of the isothermal elastic constants of the beta-CuxZn1-x alloy system as a function of the composition have been carried out. We assume the atoms interact via a two-body Morse potential function and use numerical values for the potential parameters evaluated taking into account experimental data. We find a quite good agreement between our results and the expected experimental behavior.
Resumo:
The nature of the chemical bond in three titanium oxides of different crystal structure and different formal oxidation state has been studied by means of the ab initio cluster-model approach. The covalent and ionic contributions to the bond have been measured from different theoretical techniques. All the analysis is consistent with an increasing of covalence in the TiO, Ti2O3, and TiO2 series as expected from chemical intuition. Moreover, the use of the ab initio cluster-model approach combined with different theoretical techniques has permitted us to quantify the degree of ionic character, showing that while TiO can approximately be described as an ionic compound, TiO2 is better viewed as a rather covalent oxide.
Resumo:
The aim of this study was to prospectively evaluate the accuracy and predictability of new three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction.We analyzed the preoperative and postoperative clinical and radiologic data of 10 patients with isolated blow-out orbital fractures. Fracture locations were as follows: floor (N = 7; 70%), medial wall (N = 1; 1%), and floor/medial wall (N = 2; 2%). The floor fractures were exposed by a standard transconjunctival approach, whereas a combined transcaruncular transconjunctival approach was used in patients with medial wall fractures. A three-dimensional preformed AO titanium mesh plate (0.4 mm in thickness) was selected according to the size of the defect previously measured on the preoperative computed tomographic (CT) scan examination and fixed at the inferior orbital rim with 1 or 2 screws. The accuracy of plate positioning of the reconstructed orbit was assessed on the postoperative CT scan. Coronal CT scan slices were used to measure bony orbital volume using OsiriX Medical Image software. Reconstructed versus uninjured orbital volume were statistically correlated.Nine patients (90%) had a successful treatment outcome without complications. One patient (10%) developed a mechanical limitation of upward gaze with a resulting handicapping diplopia requiring hardware removal. Postoperative orbital CT scan showed an anatomic three-dimensional placement of the orbital mesh plates in all of the patients. Volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 2.5 cm(3). There was no significant difference in volume between the reconstructed and uninjured orbits.This preliminary study has demonstrated that three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction results in (1) a high rate of success with an acceptable rate of major clinical complications (10%) and (2) an anatomic restoration of the bony orbital contour and volume that closely approximates that of the contralateral uninjured orbit.
Resumo:
Heusler alloy Mn50Ni40In10 was produced as preferentially textured ribbon flakes by melt spinning, finding the existence of martensitic-austenic transformation with both phases exhibiting ferromagnetic ordering. A microcrystalline three-layered microstructure of ordered columnar grains grown perpendicularly to ribbon plane was formed between two thin layers of smaller grains. The characteristic temperatures of the martensitic transformation were MS=213 K, Mf=173 K, AS=222 K, and Af=243 K. Austenite phase shows a cubic L21 structure (a=0.6013(3) nm at 298 K and a Curie point of 311 K), transforming into a modulated fourteen-layer modulation monoclinic martensite
Resumo:
The Heusler alloy Ni50 Mn37 Sn13 was successfully produced as ribbon flakes of thickness around 7-10 μm melt spinning. Fracture cross section micrographs in the ribbon show the formation of a microcrystalline columnarlike microstructure, with their longer axes perpendicular to the ribbon plane. Phase transition temperatures of the martensite-austenite transformation were found to be MS =218 K, Mf =207 K, AS =224 K, and Af =232 K; the thermal hysteresis of the transformation is 15 K. Ferromagnetic L 21 bcc austenite phase shows a Curie point of 313 K, with cell parameter a=0.5971 (5) nm at 298 K, transforming into a modulated 7M orthorhombic martensite with a=0.6121 (7) nm, b=0.6058 (8) nm, and c=0.5660 (2) nm, at 150 K
Resumo:
PURPOSE: To prospectively evaluate the accuracy and reliability of "freehand" posttraumatic orbital wall reconstruction with AO (Arbeitsgemeinschaft Osteosynthese) titanium mesh plates by using computer-aided volumetric measurement of the bony orbits. METHODS: Bony orbital volume was measured in 12 patients from coronal CT scan slices using OsiriX Medical Image software. After defining the volumetric limits of the orbit, the segmentation of the bony orbital region of interest of each single slice was performed. At the end of the segmentation process, all regions of interest were grouped and the volume was computed. The same procedure was performed on both orbits, and thereafter the volume of the contralateral uninjured orbit was used as a control for comparison. RESULTS: In all patients, the volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 1.85 cm3 (7%). CONCLUSIONS: This preliminary study has demonstrated that posttraumatic orbital wall reconstruction using "freehand" bending and placement of AO titanium mesh plates results in a high success rate in re-establishing preoperative bony volume, which closely approximates that of the contralateral uninjured orbit.
Resumo:
High reflectivity and high thermal conductivity, high vapour pressure of alloyingelements as well as low liquid surface tension and low ionisation potential, make laser welding of aluminium and its alloys a demanding task.Problems that occur during welding are mainly process instabilities of the keyhole and the melt pool, increased plasma formation above the melt pool and loss of alloying elements. These problems lead to unwanted metallurgical defects like hot cracks and porosity in the weld bead andother problems concerning the shape and appearance of the weld bead. In order to minimise the defects and improve the weld quality, the process and beam parameters need to be carefully adjusted along with a consideration concerning the use of filler wire for the welding process. In this work the welding of 3,0 mm thick grade 5083 aluminium alloy plates using a 3,0 kW Nd:YAG laser with grade 5183 filler wire addition is investigated. The plates were welded as butt joints with air gap sizes 0,5 mm, 0,7mm and 1,0 mm. The analysis of the weld beads obtained from the weldedsamples showed that the least imperfections were produced with 0,7 mm air gaps at moderate welding speeds. The analysis also covered the calculation of the melting efficiency and the study of the shape of the weld bead. The melting efficiency was on average around 20 % for the melting process of the welded plates. The weld beads showed the characteristic V-shape of a laser weld and retained this shape during the whole series of experiments.
Keraamisten teräpalojen käyttö niukkaseosteisten terästen lastuamiseen normaaleissa toimitustiloissa
Resumo:
Tämän tutkimuksen tavoitteena oli tutkia keraamisten kääntöterien soveltuvuus niukkaseosteräksille ja M-käsittelyn vaikutus teränkestoaikoihin. Lisäksi tavoitteena oli tutkia keraamiseosten erityisominaisuudet ja muodostaa käsitys keraamisilla kääntöterillä sorvaamisen erityisvaatimuksista. Kirjallisuusosassa selvitettiin tutkimushetkellä saatavissa olleet keraamiset teräaineseokset ja niiden ominaisuudet sekä selvitettiin keraamisten kääntöterien viimeaikaiset kehitystrendit. Lastuamistutkimus toteutettiin standardin ISO 3685:1993 mukaisesti, minkä lisäksi mitattiin lastuamisvoimat ja tehtiin kokeessa käytetyille terille lastunmurtokoe. Koemateriaalit olivat Imatra Steelin GreenCut, Hydax 25, M-käsittelemätön 42CrMo4 ja M-käsitelty MoC410M. Kokeissa käytetyt kääntöterät olivat eri valmistajien alumiinioksiditeriä, titaanikarbidiseostettuja alumiinioksiditeriä, kuituvahvisteisia ja yksi puhdas titaanikarbidiseosteinen terä. Koetulosten perusteella hyvän teränkestoajan saavuttamiseksi on tärkeää valita oikea keraamiseos ja sille soveltuvat parametrit. Oikein valituilla parametreilla M-terästä sorvattaessa tulokset ylittävät kovametalleilla saavutettavissa olevat arvot. Tulosten perusteella niukkaseostettujen terästen sorvaus onnistuu hyvin keraamisilla kääntöterillä, mutta kovametallisorvaukseen verrattuna syöttöä on laskettava ja lastuamisnopeutta lisättävä. Tämän työn tuloksia voidaan soveltaa sopivissa olosuhteissa toteutettavassa kappaletavaratuotannossa. Sovelluksen onnistuminen vaatii tukevat työstöolosuhteet ja riittävien lastuamisnopeuksien saavuttamisen.
Resumo:
The Tandem-GMAW method is the latest development as the consequences of improvements in the welding methods. The twin-wire and then the Tandem-method with the separate power sources has got a remarkable place in the welding of many types of materials with different joint types. The biggest advantage of Tandem welding method is the flexibility of choosing both the electrodes of different types from each other according to the type of the parent material. This is possible because of the feasibility of setting the separate welding parameters for both the wires. In this thesis work the effect of the variation in three parameters on the weld bead in Tandem-GMA welding method is studied. Theses three parameters are the wire feed rate in the slave wire, the wire feed rate in the master wire and the voltage difference in both the wires. The results are then compared to study the behaviour of the weld bead with the change in these parameters.
Resumo:
The present study was initiated with the aim to assess the in vivo electrochemical corrosion behaviour of CoCrMo biomedical alloys in human synovial fluids in an attempt to identify possible patient or pathology specific effects. For this, electrochemical measurements (open circuit potential OCP, polarization resistance Rp, potentiodynamic polarization curves, electrochemical impedance spectroscopy EIS) were carried out on fluids extracted from patients with different articular pathologies and prosthesis revisions. Those electrochemical measurements could be carried out with outstanding precision and signal stability. The results show that the corrosion behaviour of CoCrMo alloy in synovial fluids not only depends on material reactivity but also on the specific reactions of synovial fluid components, most likely involving reactive oxygen species. In some patients the latter were found to determine the whole cathodic and anodic electrochemical response. Depending on patients, corrosion rates varied significantly between 50 and 750mgdm(-2)year(-1).