774 resultados para Test–retest repeatability
Resumo:
A RP-HPLC procedure for the simultaneous determination of cisplatin and the complex cis,cis,trans-diamminedichlorodihydroxo-platinum(IV), was development. The developed procedure was validated in terms of linearity, accuracy, precision, limits of detection (LOD), limits of quantification (LOQ) and specificity. The limits of detection (LOD) were 0.47 x 10-4 and 0.53 x 10-4 mol L-1 and the limits of quantification (LOQ) were 1.57 x 10-4 and 1.75 x 10-4 mol L-1, for cisplatin and cis,cis,trans-diamminedichlorodihydroxopla-tinum(IV), respectively. The average recoveries of cisplatin and cis,cis,trans-diamminedichlorodihydroxoplatinum(IV) was 100.6% ± 1.4 and 101.2% ± 1.1, respectively. Intermediate (inter-day) precision, repeatability and specificity of the procedure for hydrolysis products of cisplatin were studied. The results of the study showed that the proposed RP-HPLC procedure is simple, rapid, precise, accurate and specific.
Resumo:
A method using LC/ESI-MS/MS for the quantitative analysis of Ochratoxin A in roasted coffee was described. Linearity was demonstrated (r = 0.9175). The limits of detection and quantification were 1.0 and 3.0 ng g-1, respectively. Trueness, repeatability and intermediate precision values were 89.0-108.8%; 2.4-13.7%; 12.5-17.8%, respectively. To the best of our knowledge, this is the first report in which Ochratoxin A in roasted coffee is analysed by LC/ESI-MS/MS, contributing to the field of mycotoxin analysis, and it will be used for future production of Certified Reference Material.
Resumo:
Ascorbic acid has important nutritional characteristics such as high antioxidant potential, preventing diverse damage and diseases in the tissues and the process of aging. Different isomeric forms of the ascorbic acid can be found in nature and each one have different potential antioxidant and different activity pro-vitamin C. This work examined a method to detect and quantify the isomers L-ascorbic acid (LAA) and D-iso-ascorbic acid (DIAA) in jelly fruit. The method showed acceptable selectivity, linearity, repeatability and recovery. DIAA was not found in the analyzed samples, but LAA was found up to 605 mg in 100 g of sample.
Resumo:
In this work, the materials used in the recovery of estrogens from aqueous matrices by filtration and solid phase extraction were evaluated. The results showed that glass-fiber filters allow a recovery and repeatability compatible with this type of analysis, whereas cellulose esters lead to significant losses of the analytes, mainly due to adsorption processes. On the other hand, the transferring of the sample to the extraction cartridges should be carried out with glass or Teflon tubing, since the adsorption observed with other polymeric materials (eg. silicone, Tygon, polyethylene and PVC) dramatically reduces the recovery and repeatability of the extraction process.
Resumo:
This paper regards the implementation of the QuEChERS method for the analysis by GC-FPD of 53 different pesticides from the organophosphate class, in whole UHT and pasteurized milk. Selectivity, linearity, repeatability, recovery and limits of detection and quantification were evaluated. Of all pesticide recoveries, 51 were considered satisfactory since the values ranged from 70 to 120% with RSD < 20%. The quantification limits ranged from 0.005 to 0.4 mg kg-1. The QuEChERS method was suitable for determination of 52 pesticides, presenting several advantages - quick, cheap, easy, effective, rugged and safe - with regard to other traditional methodologies.
Resumo:
The need for effective and reliable quality control in products from pharmaceutical industries renders the analyses of their active ingredients and constituents of great importance. This study presents the theoretical basis of ¹H NMR for quantitative analyses and an example of the method validation according to Resolution RE Nº 899 by the Brazilian National Health Surveillance Agency (ANVISA), in which the compound paracetamol was the active ingredient. All evaluated parameters (selectivity, linearity, accuracy, repeatability and robustness) showed satisfactory results. It was concluded that a single NMR measurement provides structural and quantitative information of active components and excipients in the sample.
Resumo:
A simple, precise, specific, repeatable and discriminating dissolution test for primaquine (PQ) matrix tablets was developed and validated according to ICH and FDA guidelines. Two UV assaying methods were validated for determination of PQ released in 0.1 M hydrochloric acid and water media. Both methods were linear (R²>0.999), precise (R.S.D.<1.87%) and accurate (97.65-99.97%). Dissolution efficiency (69-88%) and equivalence of formulations (f2) was assessed in different media and apparatuses (basket/100 rpm and paddle/50 rpm) tested. Discriminating condition was 900 mL aqueous medium, basket at 100 rpm and sampling times at 1, 4 and 8 h. Repeatability (R.S.D.<2.71%) and intermediate precision (R.S.D.<2.06%) of dissolution method were satisfactory.
Resumo:
A fast analytical method for determination of hydroquinone in pharmaceutical formulations employing batch injection analysis (BIA) with amperometric detection using a boron-doped diamond electrode is described. The supporting electrolyte was a 0.1 mol L-1 H2SO4 solution (the single reagent used for analysis). The method showed good repeatability (RSD of 0.45%, n=20), wide linear range (from 10 to 2000 µmol L-1, R=0.9999), low detection limit (0.016 µmol L-1) and satisfactory recovery values (91-96%). Accuracy of the method was evaluated by comparative analyses using high-performance liquid-chromatography. The ability to replace the electronic pipette by disposable syringes (injection procedure) in BIA systems was also shown.
Resumo:
The use and characterization of the first Certified Reference Material (CRM) of Brazilian coal for analytical quality control are presented. All results were determined within the limits of repeatability and reproducibility allowed under the standards. Notable among the characterization parameters was the mineral matter content (45.39%) obtained by an alternative procedure showing a low relative error (-2.1%) compared to the standard technique (low ashing temperature). The possible expanded application of this CRM application in national laboratories, beyond the certificated and reference parameters, has advantages such as lower cost and easy availability, but round robin tests must be performed.
Resumo:
The aim of this work was to develop and validate an analytical method for the quantification of tioconazole in polymeric nanocapsule suspensions by high performance liquid chromatography with UV detection. The analysis was performed with a mobile phase composed of methanol:water (80:20) and 0.18% ammonium hydroxide; RP-18 column and UV detection at 219 nm. The method proved to be linear in the concentration range of 5-50 µg mL-1 (r = 0.9999), specific, precise (repeatability RSD = 1.42%, intermediate precision RSD = 1.17%), accurate (98 - 102%) and robust (RSD < 2.0%). In conclusion, a simple and rapid method was validated proving suitable for quantification of tioconazole in polymeric nanocapsules.
Resumo:
17α-methyltestosterone (17α-MT) is a hormone used in medicine and aquaculture which can be found in natural waters. It is considered an emerging organic pollutant and its accurate and precise analysis is required. Therefore, this study presents the in-house validation of a new voltammetric methodology for 17α-MT analysis in natural waters. A hanging mercury drop electrode and NaOH 5.0×10-3 mol L-1 solution as the electrolyte were employed in the voltammetric determinations. To confirm the presence of 17α-MT in water samples quantitative analysis was performed by ESI-MS/MS. The methodology exhibited good selectivity, linearity, accuracy (recovery of between 100.4 and 108.8%) and precision (RSDs for repeatability of 2.85% and for intermediate precision of 14.10%, with n = 5, respectively). LOD and LOQ were 3.07 µg L-1 and 10.78 µg L-1, respectively. The methodology was suitable for determination of 17α-MT in natural waters due to low-cost, good performance and no sample pre-treatment required.
Resumo:
An evaluation of the pesticides extracted from the soil matrix was conducted using a citrate-buffered solid phase dispersion sample preparation method (QuEChERS). The identification and quantitation of pesticide compounds was performed using gas chromatography-mass spectrometry. Because of the occurrence of the matrix effect in 87% of the analyzed pesticides, the quantification was performed using matrix-matched calibration. The method's quantification limits were between 0.01 and 0.5 mg kg-1. Repeatability and intermediate precision, expressed as a relative standard deviation percentage, were less than 20%. The recoveries in general ranged between 62% and 99%, with a relative standard deviation < 20%. All the responses were linear, with a correlation coefficient (r) ≥0.99.
Resumo:
The chemical treatment evaluation in the field to control post-harvest fruit anthracnose (Colletotrichum gloeosporioides) requires a suitable disease incidence assessment on harvested papaya (Carica papaya) fruits. The minimum number of papaya fruit harvests was determined for valid treatment comparison in field trials for anthracnose chemical control. Repeatability analysis was done using previously published data. The coefficient determination (R²) estimate range, using four methods, and based on means of 12 assessment times, was 92.58 < R² < 94.45%. The number of assessment times required for R²=90% varied from seven to nine. The R² values of 85.1 < R² < 91.3% estimated by ANOVA suggested that any seven successive assessment times were sufficient for treatment comparison.
Resumo:
The goal of this work was to develop a simple and rapid preparation method for patulin analysis in apple juice without previous clean-up. This method combined sonication and liquid extraction techniques and was used for determination of patulin in 37 commercial apple juices available on the market in the South of Brazil. The method performance characteristics were determined using a sample obtained in a local market fortified at five concentration levels of patulin and done in triplicates. The coefficient of variation for repeatability at the fortification level of 20.70µg.L-1 was 3.53 % and the recovery 94.63 %, respectively. The correlation coefficient was 0.9996 and agrees with the requirements for a linear analytical method value. The detection limit was 0.21µg.L-1 and the quantification limit 0.70 µg.L-1. Only three of the analyzed samples were upper the allowed level of 50.00 µg.L-1 recommended for the World Health Organization.
Resumo:
An optode based on thymol blue (TB), an acid-based indicator, has been constructed and evaluated as a detector in FIA system for CO2 determination. The dye was chemically immobilised on the surface of a bifurcated glass optical fibre bundle, using silanisation in organic media. In FIA system, hydrogen carbonate or carbonate samples are injected in a buffer carrier solution, and then are mixed with phosphoric acid solution to generate CO2, which diffuses through a PTFE membrane, in order to be collected in an acceptor carrier fluid, pumped towards to detection cell, in which the optode was adapted. The proposed system presents two linear response ranges, from 1.0 x 10-3 to 1.0 x 10-2 mol l-1, and from 2.0 x 10-2 to 0.10 mol l-1. The sampling frequency was 11 sample h-1, with good repeatability (R.S.D < 4 %, n = 10). In flow conditions the optode lifetime was 170 h. The system was applied in the analysis of commercial mineral water and the results obtained in the hydrogen carbonate determination did not differ significantly from those obtained by potentiometry, at a confidence level of 95 %.