882 resultados para Selective neck irradiation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Burkholderia cepacia colonizes cystic fibrosis (CF) patients. We evaluated the impact of the use of a selective medium in the rate of B. cepacia recovery from respiratory samples of CF patients. During a 6-month period, respiratory samples were collected from 106 CF patients and cultivated on selective media including a B. cepacia selective medium. Confirmation of the identity of B. cepacia isolates was carried out by species specific PCR and determination of genomovar status performed by a sequential PCR approach. Results of B. cepacia isolation during this period were compared to the preceding two years, when the sample processing was identical except for the lack of the B. cepacia selective medium. B. cepacia was isolated in 11/257 (4.2%) of the samples using the selective medium, in contrast with the preceding two years, when it was isolated in 6/1029 samples (0.58%), p < 0.0001. Identity of all 11 isolates was confirmed by PCR and genomovar determination was accomplished in all but one isolate. These results suggest that the use of a selective medium increases recovery rate of B. cepacia from respiratory samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carnitine (CRT) is a biological metabolite found in urine that contributes in assessingseveral disease conditions, including cancer. Novel quick screening procedures for CRT are therefore fundamental. This work proposes a novel potentiometric device where molecularly imprinted polymers (MIPs) were used as ionophores. The host-tailored sites were imprinted on a polymeric network assembled by radical polymerization of methacrylic acid (MAA) and trimethylpropane trimethacrylate (TRIM). Non-imprinted polymers (NIPs) were produced as control by removing the template from the reaction media. The selective membrane was prepared by dispersing MIP or NIP particles in plasticizer and poly(vinyl chloride), PVC, and casting this mixture over a solid contact support made of graphite. The composition of the selective membrane was investigated with regard to kind/amount of sensory material (MIP or NIP), and the need for a lipophilic additive. Overall, MIP sensors with additive exhibited the best performance, with near-Nernstian response down to ~ 1 × 10− 4 mol L− 1, at pH 5, and a detection limitof ~ 8 × 10− 5 mol L− 1. Suitable selectivity was found for all membranes, assessed by the matched potential method against some of the most common species in urine (urea, sodium, creatinine, sulfate, fructose and hemoglobin). CRT selective membranes including MIP materials were applied successfully to the potentiometric determination of CRT in urine samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sulfamethoxazole (SMX) is among the antibiotics employed in aquaculture for prophylactic and therapeutic reasons. Environmental and food spread may be prevented by controlling its levels in several stages of fish farming. The present work proposes for this purpose new SMX selective electrodes for the potentiometric determination of this sulphonamide in water. The selective membranes were made of polyvinyl chloride (PVC) with tetraphenylporphyrin manganese (III) chloride or cyclodextrin-based acting as ionophores. 2-nitrophenyl octyl ether was employed as plasticizer and tetraoctylammonium, dimethyldioctadecylammonium bromide or potassium tetrakis (4-chlorophenyl) borate was used as anionic or cationic additive. The best analytical performance was reported for ISEs of tetraphenylporphyrin manganese (III) chloride with 50% mol of potassium tetrakis (4-chlorophenyl) borate compared to ionophore. Nersntian behaviour was observed from 4.0 × 10−5 to 1.0 × 10−2 mol/L (10.0 to 2500 µg/mL), and the limit of detection was 1.2 × 10−5 mol/L (3.0 µg/mL). In general, the electrodes displayed steady potentials in the pH range of 6 to 9. Emf equilibrium was reached before 15 s in all concentration levels. The electrodes revealed good discriminating ability in environmental samples. The analytical application to contaminated waters showed recoveries from 96 to 106%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solid-contact sensors for the selective screening of sulfadiazine (SDZ) in aquaculture waters are reported. Sensor surfaces were made from PVC membranes doped with tetraphenylporphyrin-manganese(III) chloride, α-cyclodextrin, β-cyclodextrin, or γ-cyclodextrin ionophores that were dispersed in plasticizer. Some membranes also presented a positive or a negatively charged additive. Phorphyrin-based sensors relied on a charged carrier mechanism. They exhibited a near-Nernstian response with slopes of 52 mV decade−1 and detection limits of 3.91 × 10−5 mol L−1. The addition of cationic lipophilic compounds to the membrane originated Nernstian behaviours, with slopes ranging 59.7–62.0 mV decade−1 and wider linear ranges. Cyclodextrin-based sensors acted as neutral carriers. In general, sensors with positively charged additives showed an improved potentiometric performance when compared to those without additive. Some SDZ selective membranes displayed higher slopes and extended linear concentration ranges with an increasing amount of additive (always <100% ionophore). The sensors were independent from the pH of test solutions within 2–7. The sensors displayed fast response, always <15 s. In general, a good discriminating ability was found in real sample environment. The sensors were successfully applied to the fast screening of SDZ in real waters samples from aquaculture fish farms. The method offered the advantages of simplicity, accuracy, and automation feasibility. The sensing membrane may contribute to the development of small devices allowing in locus measurements of sulfadiazine or parent-drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a new biomimetic sensor material for trimethoprim. It is prepared by means of radical polymerization, having trimethylolpropane trimethacrylate as cross-linker, benzoyl peroxide as radicalar iniciator, chloroform as porogenic solvent, and methacrylic acid and 2-vinyl pyridine as monomers. Different percentages of sensor in a range between 1 and 6% were studied. Their behavior was compared to that obtained with ion-exchanger quaternary ammonium salt (additive tetrakis(p-chlorophenyl)borate or tetraphenylborate). The effect of an anionic additive in the sensing membrane was also tested. Trimethoprim sensors with 1% of imprinted particles from methacrylic acid monomers showed the best response in terms of slope (59.7 mV/decade) and detection limit (4.01 × 10− 7 mol/L). These electrodes displayed also a good selectivity towards nickel, manganese aluminium, ammonium, lead, potassium, sodium, iron, chromium, sulfadiazine, alanine, cysteine, tryptophan, valine and glycine. The sensors were not affected by pH changes from 2 to 6. They were successfully applied to the analysis of water from aquaculture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As a result of the stressful conditions in aquaculture facilities there is a high risk of bacterial infections among cultured fish. Chlortetracycline (CTC) is one of the antimicrobials used to solve this problem. It is a broad spectrum antibacterial active against a wide range of Gram-positive and Gram-negative bacteria. Numerous analytical methods for screening, identifying, and quantifying CTC in animal products have been developed over the years. An alternative and advantageous method should rely on expeditious and efficient procedures providing highly specific and sensitive measurements in food samples. Ion-selective electrodes (ISEs) could meet these criteria. The only ISE reported in literature for this purpose used traditional electro-active materials. A selectivity enhancement could however be achieved after improving the analyte recognition by molecularly imprinted polymers (MIPs). Several MIP particles were synthesized and used as electro-active materials. ISEs based in methacrylic acid monomers showed the best analytical performance according to slope (62.5 and 68.6 mV/decade) and detection limit (4.1 × 10−5 and 5.5 × 10−5 mol L−1). The electrodes displayed good selectivity. The ISEs are not affected by pH changes ranging from 2.5 to 13. The sensors were successfully applied to the analysis of serum, urine and fish samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The indiscriminate use of antibiotics in food-producing animals has received increasing attention as a contributory factor in the international emergence of antibiotic-resistant bacteria (Woodward in Pesticide, veterinary and other residues in food, CRC Press, Boca Raton, 2004). Numerous analytical methods for quantifying antibacterial residues in edible animal products have been developed over years (Woodward in Pesticide, veterinary and other residues in food, CRC Press, Boca Raton, 2004; Botsoglou and Fletouris in Handbook of food analysis, residues and other food component analysis, Marcel Dekker, Ghent, 2004). Being Amoxicillin (AMOX) one of those critical veterinary drugs, efforts have been made to develop simple and expeditious methods for its control in food samples. In literature, only one AMOX-selective electrode has been reported so far. In that work, phosphotungstate:amoxycillinium ion exchanger was used as electroactive material (Shoukry et al. in Electroanalysis 6:914–917, 1994). Designing new materials based on molecularly imprinted polymers (MIPs) which are complementary to the size and charge of AMOX could lead to very selective interactions, thus enhancing the selectivity of the sensing unit. AMOX-selective electrodes used imprinted polymers as electroactive materials having AMOX as target molecule to design a biomimetic imprinted cavity. Poly(vinyl chloride), sensors of methacrylic acid displayed Nernstian slopes (60.7 mV/decade) and low detection limits (2.9 × 10−5 mol/L). The potentiometric responses were not affected by pH within 4–5 and showed good selectivity. The electrodes were applied successfully to the analysis of real samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sensors 2010, 10, 11530-11555

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To describe the anatomy and imaging findings of the prostatic arteries (PAs) on multirow-detector pelvic computed tomographic (CT) angiography and digital subtraction angiography (DSA) before embolization for symptomatic benign prostatic hyperplasia (BPH). MATERIALS AND METHODS: In a retrospective study from May 2010 to June 2011, 75 men (150 pelvic sides) underwent pelvic CT angiography and selective pelvic DSA before PA embolization for BPH. Each pelvic side was evaluated regarding the number of independent PAs and their origin, trajectory, termination, and anastomoses with adjacent arteries. RESULTS: A total of 57% of pelvic sides (n = 86) had only one PA, and 43% (n = 64) had two independent PAs identified (mean PA diameter, 1.6 mm ± 0.3). PAs originated from the internal pudendal artery in 34.1% of pelvic sides (n = 73), from a common trunk with the superior vesical artery in 20.1% (n = 43), from the anterior common gluteal-pudendal trunk in 17.8% (n = 38), from the obturator artery in 12.6% (n = 27), and from a common trunk with rectal branches in 8.4% (n = 18). In 57% of pelvic sides (n = 86), anastomoses to adjacent arteries were documented. There were 30 pelvic sides (20%) with accessory pudendal arteries in close relationship with the PAs. No correlations were found between PA diameter and patient age, prostate volume, or prostate-specific antigen values on multivariate analysis with logistic regression. CONCLUSIONS: PAs have highly variable origins between the left and right sides and between patients, and most frequently arise from the internal pudendal artery.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain the PhD degree in Electrical and Computer Engineering - Electronics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine if mid-term outcome following endovascular aneurysm repair (EVAR) with the Endurant Stent Graft (Medtronic, Santa Rosa, CA, USA) is influenced by severe proximal neck angulation. METHODS: A retrospective case-control study was performed using data from a prospective multicenter database. All measurements were obtained using dedicated reconstruction software and center-lumen line reconstruction. Patients with neck length >15 mm, infrarenal angle (β) >75°, and/or suprarenal angle (α) >60°, or neck length >10 mm with β >60°, and/or α >45° were compared with a matched control group. Primary endpoint was primary clinical success. Secondary endpoints were freedom from rupture, type 1A endoleak, stent fractures, freedom from neck-related reinterventions, and aneurysm-related adverse events. Morphological neck variation over time was also assessed. RESULTS: Forty-five patients were included in the study group and were compared with a matched control group with 65 patients. Median follow-up time was 49.5 months (range 30.5-58.4). The 4-year primary clinical success estimates were 83% and 80% for the angulated and nonangulated groups (p = .42). Proximal neck angulation did not affect primary clinical success in a multivariate model (hazard ratio 1.56, 95% confidence interval 0.55-4.41). Groups did not differ significantly in regard to freedom from rupture (p = .79), freedom from type 1A endoleak (p = .79), freedom from neck-related adverse events (p = .68), and neck-related reinterventions (p = .68). Neck angle reduction was more pronounced in patients with severe proximal neck angulation (mean Δα -15.6°, mean Δβ -30.6°) than in the control group (mean Δα -0.39°, mean Δβ -5.9°) (p < .001). CONCLUSION: Mid-term outcomes following EVAR with the Endurant Stent Graft were not influenced by severe proximal neck angulation in our population. Despite the conformability of the device, moderate aortic neck remodeling was identified in the group of patients with angulated neck anatomy on the first computed tomography scan after implantation with no important further remodeling afterwards. No device integrity failures were encountered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: Objetivo: Este trabalho teve como objetivo contribuir para o processo de adaptação cultural do Neck Disability Index (NDI), através da análise da sua unidimensionalidade e do estudo da sua fiabilidade (consistência interna e fiabilidade teste-reteste), validade de constructo e poder de resposta. De igual forma pretendeu-se caraterizar a intervenção realizada pela fisioterapia e os resultados obtidos em pacientes com Dor Cervical Crónica (DCC). Introdução: A dor cervical é um problema cada vez mais comum nos países industrializados, constituindo uma das três condições mais frequentemente reportadas por queixas de origem músculo-esquelética. A sua incidência é um fenómeno em crescimento, com custos implicados para a sociedade. Desta forma reconhece-se a importância de um instrumento que monitorize a evolução da incapacidade funcional associada à DCC. O NDI é atualmente o instrumento de avaliação mais recomendado para avaliar a incapacidade funcional associada à dor cervical. Foi traduzido e adaptado à língua portuguesa, mas à data não foi realizada nenhuma avaliação das suas propriedades psicométricas. Por outro lado, apesar de a literatura referir que os serviços de Fisioterapia são extremamente procurados por indivíduos com DCC, em Portugal, a informação sobre a sua prática nesta condição clínica é escassa ou mesmo inexistente. Assim, e sendo a incapacidade nas atividades funcionais uma das variáveis de maior impacto da DCC e ao mesmo tempo um dos resultados principais da intervenção da Fisioterapia, importa por um lado possuir instrumentos capazes de avaliar o nível de incapacidade funcional e a sua mudança, e por outro, aferir qual a intervenção realizada pela Fisioterapia e quais os resultados obtidos. Metodologia: Realizou-se um estudo de coorte prospetivo com uma amostra de conveniência, do tipo não probabilístico, constituída por 88 pacientes com DCC de origem músculo-esquelética e causa não traumática referenciados para 6 serviços de fisioterapia / medicina física e de reabilitação de clínicas e centros de reabilitação, sendo elegíveis todos os pacientes que cumprissem os critérios de inclusão e exclusão estabelecidos. Os pacientes foram avaliados em três momentos pré-definidos: antes do início das sessões de fisioterapia ou na 1ª semana de tratamento; 4 a 7 dias após a 1ª avaliação; e 7 semanas após o início da fisioterapia. Para verificação da unidimensionalidade do NDI, procedeu-se a uma Análise Fatorial Exploratória. As propriedades psicométricas do NDI avaliadas foram a Fiabilidade (consistência interna e fiabilidade teste-reteste), a Validade de Constructo e o Poder de Resposta. Posteriormente procedeu-se à caraterização da prática da fisioterapia quanto às modalidades utilizadas, número de sessões de tratamento e duração do episódio de cuidados. Adicionalmente descreveu-se os resultados obtidos após a intervenção da fisioterapia ao nível da dor e incapacidade. Resultados: os resultados obtidos foram positivos e significativos, com a confirmação da unidimensionalidade do NDI, sendo que em todos os critérios seguidos o fator mínimo retido foi de um. Na avaliação da consistência interna o valor obtido foi acima do mínimo aceitável (α Cronbach = 0,77), enquanto o valor de fiabilidade teste-reteste foi elevado (CCI =0,95). De igual forma, os resultados foram positivos para a validade de constructo, obtendo-se uma associação positiva do NDI com a Escala Numérica da dor (END). O valores de poder de resposta reportaram uma Área Abaixo da Curva de 0,63 (IC 95%=0,51-0,75), com valor de Diferença Mínima Clinicamente importante de 5,5 pontos (sensibilidade = 69,6%; especificidade = 43,6%). Relativamente á intervenção de fisioterapia em casos de DCC verificou-se que as características da prática da fisioterapia reportadas neste relatório são de difícil comparação ou análise dada a escassez ou inexistência de trabalhos publicados sobre este assunto em pacientes com DCC. No entanto, neste estudo, encontraram-se reduções significativas na intensidade da dor e incapacidade funcional após a intervenção de fisioterapia (z= -7,16; p<0,001 e t= 10,412, p<0,05, respetivamente). Conclusão: Os resultados do presente estudo revelam que o NDI-VP possui uma boa Fiabilidade, Validade de Constructo e Poder de Resposta. Revela ainda que a intervenção da fisioterapia em casos de DCC, apesar da escassez de trabalhos publicados, proporciona uma redução significativa dos níveis de dor e incapacidade em pacientes com DCC.--------------- ABSTRACT:Objective: the aim of this study was to contribute for the process of cultural adaption of the Neck Disability Index (NDI), through the analysis of his unidimensionality and the study of his reliability (internal consistency and test-retest reliability), construct validity and responsiveness. At the same time it pretends to characterize the intervention performed by physical therapy and the results in patients with Chronic Neck Pain (CNP). Introduction: neck pain is a common problem in the industrialized countries, since is one of the three most reported conditions by complaints with musculoskeletal origin. His incidence is a growth phenomena that implicate great costs to society. Therefore the importance of an instrument that monitories the evolution of the functional disability associated to CNP is recognized. Nowadays, NDI is the instrument most recommended to evaluate functional disability associated to neck pain. It has been translated and adapted to portuguese but, till now, no evaluation of his psychometric proprieties has been completed. In the other hand, despite literature refers that physical therapy services are extremely searched by patients with neck pain, in Portugal, the information about practice in this clinical condition is very few or inexistent. Therefore, and since disability in the functional activities is one of the variables with most impact of CNP and, at the same time, one of the main results of physical therapy interventions, it’s important to have instruments capable of evaluate the level of functional disability and his change, and also calculate which intervention of physical therapy is most appropriate and his results. Methodology: it was used a prospective cohort study with a convenience sample, non-probabilistic, consisting of 88 patients with CNP of musculoskeletal origin and non-traumatic cause, referred to 6 physical therapy services of clinics and rehabilitation centers, and fulfilled the inclusion and exclusion criteria established. Patients were evaluated in three pre-defined moments: before the beginning of physical therapy or during the first week of treatment; 4 to 7 days after the first evaluation; and 7 weeks after beginning of physical therapy. To verify NDI unidimensionality, we run an Exploratory Factorial Analysis. NDI psychometric proprieties evaluated were reliability (internal consistency and test-retest reliability), construct validity and responsiveness. Subsequently, it was proceeded the characterization the practice of physical therapy regarding to the modalities used, the number of treatment sessions and duration of the episode of care. Additionally it was described the results obtained after the intervention of the physical therapy, the level of pain and the disability. Results: results were positive and significant, with the confirmation of the NDI unidimensionality, since in every followed criteria the minimal retained factor was one. In the evaluation of internal consistency the value was above the minimal accepted (α Cronbach = 0,77), and the test-retest reliability value was high (CCI =0,95). Results were positive to construct validity, with an positive association of the NDI with Numeric Rating Scale (NRS). Responsiveness values reported an Area Under Curve (AUC) of 0,63 (IC 95%=0,51-0,75) with a Minimal Important Detectable Change (MIDC) of 5,5 points (sensitivity = 69,9%; specificity = 43,6%). Regarding physical therapy interventions in CNP, it was verified that the physical therapy characteristics reported are difficult to compare or analyze since there are very few published studies about this topic. However, in this study, significant reductions were founded in pain intensity and functional disability after intervention(z= -7,16; p<0,001 and t= 10,412, p<0,05, respectively).Conclusion: present study results reveals that NDI has an good reliability, construct validity and responsiveness. It also reveals that physical therapy intervention in CNP, beside few studies published, result in a significant reduction of pain and disability levels in patients with CNP.