898 resultados para SPIRAL CT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To develop a method for objective assessment of fine motor timing variability in Parkinson’s disease (PD) patients, using digital spiral data gathered by a touch screen device. BACKGROUND: A retrospective analysis was conducted on data from 105 subjects including65 patients with advanced PD (group A), 15 intermediate patients experiencing motor fluctuations (group I), 15 early stage patients (group S), and 10 healthy elderly subjects (HE) were examined. The subjects were asked to perform repeated upper limb motor tasks by tracing a pre-drawn Archimedes spiral as shown on the screen of the device. The spiral tracing test was performed using an ergonomic pen stylus, using dominant hand. The test was repeated three times per test occasion and the subjects were instructed to complete it within 10 seconds. Digital spiral data including stylus position (x-ycoordinates) and timestamps (milliseconds) were collected and used in subsequent analysis. The total number of observations with the test battery were as follows: Swedish group (n=10079), Italian I group (n=822), Italian S group (n = 811), and HE (n=299). METHODS: The raw spiral data were processed with three data processing methods. To quantify motor timing variability during spiral drawing tasks Approximate Entropy (APEN) method was applied on digitized spiral data. APEN is designed to capture the amount of irregularity or complexity in time series. APEN requires determination of two parameters, namely, the window size and similarity measure. In our work and after experimentation, window size was set to 4 and similarity measure to 0.2 (20% of the standard deviation of the time series). The final score obtained by APEN was normalized by total drawing completion time and used in subsequent analysis. The score generated by this method is hence on denoted APEN. In addition, two more methods were applied on digital spiral data and their scores were used in subsequent analysis. The first method was based on Digital Wavelet Transform and Principal Component Analysis and generated a score representing spiral drawing impairment. The score generated by this method is hence on denoted WAV. The second method was based on standard deviation of frequency filtered drawing velocity. The score generated by this method is hence on denoted SDDV. Linear mixed-effects (LME) models were used to evaluate mean differences of the spiral scores of the three methods across the four subject groups. Test-retest reliability of the three scores was assessed after taking mean of the three possible correlations (Spearman’s rank coefficients) between the three test trials. Internal consistency of the methods was assessed by calculating correlations between their scores. RESULTS: When comparing mean spiral scores between the four subject groups, the APEN scores were different between HE subjects and three patient groups (P=0.626 for S group with 9.9% mean value difference, P=0.089 for I group with 30.2%, and P=0.0019 for A group with 44.1%). However, there were no significant differences in mean scores of the other two methods, except for the WAV between the HE and A groups (P<0.001). WAV and SDDV were highly and significantly correlated to each other with a coefficient of 0.69. However, APEN was not correlated to neither WAV nor SDDV with coefficients of 0.11 and 0.12, respectively. Test-retest reliability coefficients of the three scores were as follows: APEN (0.9), WAV(0.83) and SD-DV (0.55). CONCLUSIONS: The results show that the digital spiral analysis-based objective APEN measure is able to significantly differentiate the healthy subjects from patients at advanced level. In contrast to the other two methods (WAV and SDDV) that are designed to quantify dyskinesias (over-medications), this method can be useful for characterizing Off symptoms in PD. The APEN was not correlated to none of the other two methods indicating that it measures a different construct of upper limb motor function in PD patients than WAV and SDDV. The APEN also had a better test-retest reliability indicating that it is more stable and consistent over time than WAV and SDDV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To develop a method for objective quantification of PD motor symptoms related to Off episodes and peak dose dyskinesias, using spiral data gathered by using a touch screen telemetry device. The aim was to objectively characterize predominant motor phenotypes (bradykinesia and dyskinesia), to help in automating the process of visual interpretation of movement anomalies in spirals as rated by movement disorder specialists. Background: A retrospective analysis was conducted on recordings from 65 patients with advanced idiopathic PD from nine different clinics in Sweden, recruited from January 2006 until August 2010. In addition to the patient group, 10 healthy elderly subjects were recruited. Upper limb movement data were collected using a touch screen telemetry device from home environments of the subjects. Measurements with the device were performed four times per day during week-long test periods. On each test occasion, the subjects were asked to trace pre-drawn Archimedean spirals, using the dominant hand. The pre-drawn spiral was shown on the screen of the device. The spiral test was repeated three times per test occasion and they were instructed to complete it within 10 seconds. The device had a sampling rate of 10Hz and measured both position and time-stamps (in milliseconds) of the pen tip. Methods: Four independent raters (FB, DH, AJ and DN) used a web interface that animated the spiral drawings and allowed them to observe different kinematic features during the drawing process and to rate task performance. Initially, a number of kinematic features were assessed including ‘impairment’, ‘speed’, ‘irregularity’ and ‘hesitation’ followed by marking the predominant motor phenotype on a 3-category scale: tremor, bradykinesia and/or choreatic dyskinesia. There were only 2 test occasions for which all the four raters either classified them as tremor or could not identify the motor phenotype. Therefore, the two main motor phenotype categories were bradykinesia and dyskinesia. ‘Impairment’ was rated on a scale from 0 (no impairment) to 10 (extremely severe) whereas ‘speed’, ‘irregularity’ and ‘hesitation’ were rated on a scale from 0 (normal) to 4 (extremely severe). The proposed data-driven method consisted of the following steps. Initially, 28 spatiotemporal features were extracted from the time series signals before being presented to a Multilayer Perceptron (MLP) classifier. The features were based on different kinematic quantities of spirals including radius, angle, speed and velocity with the aim of measuring the severity of involuntary symptoms and discriminate between PD-specific (bradykinesia) and/or treatment-induced symptoms (dyskinesia). A Principal Component Analysis was applied on the features to reduce their dimensions where 4 relevant principal components (PCs) were retained and used as inputs to the MLP classifier. Finally, the MLP classifier mapped these components to the corresponding visually assessed motor phenotype scores for automating the process of scoring the bradykinesia and dyskinesia in PD patients whilst they draw spirals using the touch screen device. For motor phenotype (bradykinesia vs. dyskinesia) classification, the stratified 10-fold cross validation technique was employed. Results: There were good agreements between the four raters when rating the individual kinematic features with intra-class correlation coefficient (ICC) of 0.88 for ‘impairment’, 0.74 for ‘speed’, 0.70 for ‘irregularity’, and moderate agreements when rating ‘hesitation’ with an ICC of 0.49. When assessing the two main motor phenotype categories (bradykinesia or dyskinesia) in animated spirals the agreements between the four raters ranged from fair to moderate. There were good correlations between mean ratings of the four raters on individual kinematic features and computed scores. The MLP classifier classified the motor phenotype that is bradykinesia or dyskinesia with an accuracy of 85% in relation to visual classifications of the four movement disorder specialists. The test-retest reliability of the four PCs across the three spiral test trials was good with Cronbach’s Alpha coefficients of 0.80, 0.82, 0.54 and 0.49, respectively. These results indicate that the computed scores are stable and consistent over time. Significant differences were found between the two groups (patients and healthy elderly subjects) in all the PCs, except for the PC3. Conclusions: The proposed method automatically assessed the severity of unwanted symptoms and could reasonably well discriminate between PD-specific and/or treatment-induced motor symptoms, in relation to visual assessments of movement disorder specialists. The objective assessments could provide a time-effect summary score that could be useful for improving decision-making during symptom evaluation of individualized treatment when the goal is to maximize functional On time for patients while minimizing their Off episodes and troublesome dyskinesias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A challenge for the clinical management of advanced Parkinson’s disease (PD) patients is the emergence of fluctuations in motor performance, which represents a significant source of disability during activities of daily living of the patients. There is a lack of objective measurement of treatment effects for in-clinic and at-home use that can provide an overview of the treatment response. The objective of this paper was to develop a method for objective quantification of advanced PD motor symptoms related to off episodes and peak dose dyskinesia, using spiral data gathered by a touch screen telemetry device. More specifically, the aim was to objectively characterize motor symptoms (bradykinesia and dyskinesia), to help in automating the process of visual interpretation of movement anomalies in spirals as rated by movement disorder specialists. Digitized upper limb movement data of 65 advanced PD patients and 10 healthy (HE) subjects were recorded as they performed spiral drawing tasks on a touch screen device in their home environment settings. Several spatiotemporal features were extracted from the time series and used as inputs to machine learning methods. The methods were validated against ratings on animated spirals scored by four movement disorder specialists who visually assessed a set of kinematic features and the motor symptom. The ability of the method to discriminate between PD patients and HE subjects and the test-retest reliability of the computed scores were also evaluated. Computed scores correlated well with mean visual ratings of individual kinematic features. The best performing classifier (Multilayer Perceptron) classified the motor symptom (bradykinesia or dyskinesia) with an accuracy of 84% and area under the receiver operating characteristics curve of 0.86 in relation to visual classifications of the raters. In addition, the method provided high discriminating power when distinguishing between PD patients and HE subjects as well as had good test-retest reliability. This study demonstrated the potential of using digital spiral analysis for objective quantification of PD-specific and/or treatment-induced motor symptoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O câncer cervical acomete anualmente cerca de 470.000 mulheres em todo o mundo e mais de 16.000 mulheres no Brasil. O desenvolvimento do câncer cervical e sua associação ao Papilomavírus Humano (HPV) estão bem documentados, sendo este o fator principal para o desenvolvimento do câncer cervical. A infecção genital por Chlamydia trachomatis é estudada como um co-fator no desenvolvimento de neoplasias intraepiteliais cervicais (NICs) e outras alterações celulares significativas em mulheres com histórico de infecção por HPV. Este estudo tem como objetivo conhecer a prevalência de infecção por HPV e Chlamydia trachomatis em uma amostra de mulheres assintomáticas de uma área geográfica localizada na zona norte de Porto Alegre, bem como verificar as características associadas à presença desta co-infecção e sua relação com lesões cervicais. Trata-se de um estudo transversal cujo desfecho é a positividade ao HPV e à Chlamydia trachomatis em uma amostra de mulheres assintomáticas de Porto Alegre. Um total de 1217 amostras de material do colo do útero foi coletado para realização do exame citopatológico e para a identificação do DNA-HPV e DNA-CT através da técnica da Reação em Cadeia da Polimerase (PCR). Colposcopia e biópsia foram realizadas sempre que a citologia estivesse alterada e/ou a PCR para o HPV-DNA fosse positiva. A prevalência de HPV e Chlamydia trachomatis e sua distribuição por faixa etária são descritas, bem como a sua associação com as variáveis estudadas através das Razões de Chances (RC) estimadas por regressão logística múltipla. Observou-se uma prevalência de HPV-DNA de 28,4% (n=346/1217), de CT-DNA de 12,6% (n=152/1208) e de co-infecção por HPV e CT de 6,5% (n=78/1208). Mulheres não brancas (Razão de Chance (RC) =1,60; Intervalo de Confiança (IC) de 95%:1,10-2,38),assalariadas (RC=1,74; IC95%:1,17-2,60) e com parceiro apresentando história de condiloma genital (RC=2,35; IC95%:1,17-4,72) mostraram-se associadas com a positividade para HPV. A infecção por CT mostrou uma associação positiva com mulheres que iniciaram a vida sexual antes dos vinte anos (RC=1,82; IC95%:1,05-3,15) e assalariadas (RC=1,93; IC95%:1,15-3,25). Quanto à co-infecção por HPV e CT, mulheres com mais de três de parceiros sexuais na vida (RC=2,02; IC 95%:1,12-3,65) apresentaram uma associação positiva com o desfecho. Com relação à citologia, tanto a infecção por HPV quanto a co-infecção apresentaram associação significativa com anormalidades citológicas (p≤0.001). Os resultados mostraram uma elevada prevalência de HPV, de CT e de co-infecção em uma amostra de mulheres assintomáticas reforçando dados relatados na literatura. A associação destas infecções com variáveis sócioeconômicas, de comportamento sexual e com lesões do colo uterino, indicam a importância de medidas para a promoção e prevenção de saúde com este alvo específico dentro da rotina de serviços de atenção primária. Desta forma, acredita-se que estes dados possam ser muito úteis no planejamento de programas, incluindo o controle de Doenças Sexualmente Transmissíveis e a utilização de vacinas para o HPV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The capture web of N. clavipes presents viscous droplets, which play important roles in web mechanics and prey capture. By using scanning and transmission electron microscopy, it was demonstrated that the web droplets are constituted of different chemical environments, provided by the existence both of an aqueous and a lipid layer, which, in turn, present a suspension of tenths of vesicles containing polypeptides and/or tipids. GC/EI-MS Analysis of the contents of these vesicles led to the identification of some saturated fatty acids, such as decanoic acid, undecanoic acid, dodecanoic acid, tetradecanoic acid, octadecanoic acid, and icosanoic acid, while other components were unsaturated fatty acids, such as (Z)-tetradec-9-enoic acid, (Z)-octadec-9-enoic acid, and (Z)-icosa-11-enoic acid; and polyunsaturated fatty acids like (9Z,12Z)-octadeca-9,12-dienoic acid, (9Z,12Z,15Z)-octadeca-9,12,15-trienoic acid, and (11Z,14Z)-icosa-11,14-dienoic acid. Toxic proteins such as calcium-activated proteinase and metalloproteinase jararhagin-like precursor were also identified by using a proteomic approach, indicating the possible involvement of these enzymes in the pre-digestion of spiders' preys web-captured. Apparently, the mixture of fatty acids are relatively toxic to insects by topical application (LD50 64.3 +/- 7.6 ng mg(-1) honeybee), while the proteins alone present no topical effect; however, when injected into the prey-insects, these proteins presented a moderate toxicity (LD50 40.3 +/- 4.8 ng mg(-1) honeybee); the mixture of fatty acids and proteins is very toxic to the preys captured by the web droplets of the viscid spiral of Nephila clavipes when topically applied on them (LD50 14.3 +/- 1.8ng mg(-1) honeybee).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ca0.95Sm0.05TiO3 (CT:Sm) powder was prepared by the polymeric precursor method (PPM). Order-disorder at short and long range has been investigated by means of Raman spectroscopy, X-ray diffraction (XRD), and photoluminescence emission (PL) experimental techniques. The broad PL band and the Sm emission spectrum measured at room temperature indicate the increase of structural order with annealing temperature. The measured PL emission reveals that the PL intensity changes with the degree of disorder in the CT: Sm. The electronic structures were performed by the ab initio periodic method in the DFT level with the hybrid nonlocal B3LYP approximation. Theoretical results are analyzed in terms of DOS, charge densities, and Mulliken charges. Localized levels into the band gap of the CT: Sm material favor the creation of the electron-hole pair, supporting the observed room-temperature PL phenomenon.