912 resultados para SPECT-CT
Resumo:
The pathophysiology of neurodegenerative diseases (ND) such as Alzheimer's disease (AD) and Parkinson's disease (PD) has not yet been completely elucidated. However, in the past few years, there have been great knowledge advances about intra-and extracellular proteins that may display impaired function or expression in AD, PD and other ND, such as amyloid beta (AB), alpha-synuclein, tau protein and neuroinfiammatory markers. Recent developments in the imaging techniques of positron emission tomography (PET) and single photon emission computed tomography (SPECT) now allow the non-invasive tracking of such molecular targets of known relevance to ND in vivo. This article summarizes recent findings of PET and SPECT studies using these novel methods, and discusses their potential role in the field of drug development for ND as well as future clinical applications in regard to differential diagnosis of ND and monitoring of disease progression.
Resumo:
Objectives: Previous evidence supports a direct relationship between the calcium burden (volume) on post-contrast CT with the percent internal carotid artery (ICA) stenosis at the carotid bifurcation. We sought to further investigate this relationship by comparing non-enhanced CT (NECT) and digital subtraction angiography (DSA). Methods: 50 patients (aged 41-82 years) were retrospectively identified who had undergone cervical NECT and DSA. A 64-multidetector array CT (MDCT) scanner was utilised and the images reviewed using preset window widths/levels (30/300) optimised to calcium, with the volumes measured via three-dimensional reconstructive software. Stenosis measurements were performed on DSA and luminal diameter stenoses >40% were considered "significant". Volume thresholds of 0.01, 0.03, 0.06, 0.09 and 0.12 cm(3) were utilised and Pearson's correlation coefficient (r) was calculated to correlate the calcium volume with percent stenosis. Results: Of 100 carotid bifurcations, 88 were available and of these 7 were significantly stenotic. The NECT calcium volume moderately correlated with percent stenosis on DSA r=0.53 (p<0.01). A moderate-strong correlation was found between the square root of calcium volume on NECT with percent stenosis on DSA (r=0.60, p<0.01). Via a receiver operating characteristic curve, 0.06 cm(3) was determined to be the best threshold (sensitivity 100%, specificity 90.1%, negative predictive value 100% and positive predictive value 46.7%) for detecting significant stenoses. Conclusion: This preliminary investigation confirms a correlation between carotid bifurcation calcium volume and percent ICA stenosis and is promising for the optimal threshold for stenosis detection. Future studies could utilise calcium volumes to create a "score" that could predict high grade stenosis.
Resumo:
Objectives The aim of this study was to determine the prevalence of apical periodontitis (AP) detected in cone beam CT (CBCT) images from a database. Methods CBCT images of 300 Brazilian patients were assessed. AP images were measured in three dimensions. Age, gender, number and location of total teeth in each patient were considered. AP location was considered according to tooth groups. The extent of AP was determined by the largest diameter in any of the three dimensions. Percentages and the X2 test were used for statistical analysis. Results AP was found in 51.4% of the patients and in 3.4% of the teeth. Higher prevalence of AP was found in 60- to 69-year-olds (73.1%) and in mandibular molars (5.9%) (p < 0.05). Inadequate endodontic treatment presented higher prevalence of AP (78.1%). Conclusions AP can be frequently found in CBCT examinations. The presence of AP has a significant association with patients' age, and tooth type and condition. CBCT databases are useful for cross-sectional studies about AP prevalence in a population.
Resumo:
Computed tomography (CT)-guided percutaneous drilling is an alternative for osteoid osteoma treatment. This study aims to evaluate the remodeling of the drill orifice. The success rate and complications were also recorded and compared with other treatment methods.
Resumo:
OBJETIVO: Avaliar a PET/CT na abordagem de pacientes com câncer de cabeça e pescoço. MATERIAIS E MÉTODOS: Estudo retrospectivo de 63 prontuários e exames de PET/CT de pacientes com câncer de cabeça e pescoço. RESULTADOS: Foram encontradas alterações em 76% dos exames. Destes, 7 (11%) foram considerados falso-positivos, com SUV < 5,0. A PET/CT mostrou-se negativa em 15 situações (24%). Dos 14 casos nos quais se utilizou o exame para estadiamento, em 3 (22%) houve aumento no estadiamento. CONCLUSÃO: A PET/CT mostra-se como exame de potencial valor na rotina de avaliação de pacientes com câncer de cabeça e pescoço, entretanto, necessitamos de maior número de casos para definirmos protocolo de uso.
Resumo:
Background: Few data on the definition of simple robust parameters to predict image noise in cardiac computed tomography (CT) exist. Objectives: To evaluate the value of a simple measure of subcutaneous tissue as a predictor of image noise in cardiac CT. Methods: 86 patients underwent prospective ECG-gated coronary computed tomographic angiography (CTA) and coronary calcium scoring (CAC) with 120 kV and 150 mA. The image quality was objectively measured by the image noise in the aorta in the cardiac CTA, and low noise was defined as noise < 30HU. The chest anteroposterior diameter and lateral width, the image noise in the aorta and the skin-sternum (SS) thickness were measured as predictors of cardiac CTA noise. The association of the predictors and image noise was performed by using Pearson correlation. Results: The mean radiation dose was 3.5 ± 1.5 mSv. The mean image noise in CT was 36.3 ± 8.5 HU, and the mean image noise in non-contrast scan was 17.7 ± 4.4 HU. All predictors were independently associated with cardiac CTA noise. The best predictors were SS thickness, with a correlation of 0.70 (p < 0.001), and noise in the non-contrast images, with a correlation of 0.73 (p < 0.001). When evaluating the ability to predict low image noise, the areas under the ROC curve for the non-contrast noise and for the SS thickness were 0.837 and 0.864, respectively. Conclusion: Both SS thickness and CAC noise are simple accurate predictors of cardiac CTA image noise. Those parameters can be incorporated in standard CT protocols to adequately adjust radiation exposure.
Resumo:
[ES]The purpose of this paper was to use threedimensional computed tomographic reconstruction as another tool to teach in the veterinary colleges. 2-millimeters thick transverse images of two foals and one dog were obtained. Images provided excellent detail of relevant anatomic structures and detailed information regarding the extent of disease and accurate discrimination of neoplastic versus non-neoplastic diseases. Tridimensional reconstruction can be a valuable diagnostic aid for clinical evaluation of several disturbances and could be used as a tool for teaching anatomy in veterinary schools.
Resumo:
Abstract Due to the ongoing efforts in transplanting b-cell mass there is also a great medical interest in specific b-cell imaging agents to quantify the acceptance of transplanted islets in humans in vivo. Additionally, in the context of type 1 diabetes mellitus the chronic and progressive loss of b-cells caused by autoimmune destruction has led to concerted efforts to prevent further loss of b-cells by autoantigen-specific immunotherapy of pre-diabetic patients. nateglinide and glibenclamide are SUR1 ligands used to stimulate insulin secretion in type 2 diabetic patients. They bind to a class of molecules known as the ATP-sensitive potassium channels, located on the insulin producing b-cells of the islets of Langerhans and are therefore excellent candidates as b-cell specific tracers. To obtain a precursor for a direct labelling of nateglinide with [18F]fluoride, the aromatic system of the phenylalanine structure element was derivatised to obtain a phenolic OH-group in 4-position which is capable of further derivatisation. The formed phenylether N-(trans-4-isopropylcyclohexanecarbonyl)-O-(2-hydroxyethyl)-D-tyrosin benzylester was tried to be tosylated according to several literature procedures but none of them was applicable. The catalytic influence of ytterbium(III)triflate in the reaction of toluenesulfonic acid anhydride and the alcohol was investigated. It was found that Yb(III) facilitates the tosylation of the alcohol under non-basic conditions and was extended to the tosylation of a great variety of different alcohols to prove its applicability in general. The radioactive labelling of N-(trans-4-isopropyl-cyclohexanecarbonyl)-O-(2-[18F]fluoroethyl)-D-tyrosine with [18F]F-/ Kryptofix® 222/ K2CO3-system was achieved in radiochemical yields (RCY) of 10 % after deprotection with Pd/ C and H2. In addition to the direct labelling approach, a labelling procedure applying 2[18F]fluoroethyltosylate and N-(trans-4-isopropyl-cyclohexanecarbonyl)-D-tyrosin was performed in 40 % RCY. Unfortunately the determination of the KD value of N-(trans-4-isopropylcyclohexanecarbonyl)-O-(2-fluoroethyl)-D-tyrosine revealed a significant decrease in affinity compared to original nateglinide. The in vivo evaluation of some 18F-labelled glibenclamide derivatives in humans and animals revealed that longer measuring times are warranted because a high liver uptake spoiles the data acquisition and the activity washout proceeds very slowly. Therefore glibenclamide was labelled with a radioisotope with a longer half life such as 99mTc (t1/2 = 6 h) to lengthen the possible time frame for image acquisition. The synthesis of a 99mTc labelled hydrophilic glibenclamide derivative was performed. It is hoped that gliben-clamide is internalised into the b-cell and there binds to the 95 % of intracellular SUR-1 receptors with eventual metablolisation and thus trapping in the cell. The KD-value of the corresponding Re-compound was determined to be 0.5 nM and the insulin secretion properties were similar to those of original glibenclamide. The labelling precursor N-{4-[N,N-bis-(carboxy-methyl)-aminoethyl)-5-chlorobenzene-carboxamido]-ethyl}-benzene-sulfonyl-N'-cyclohexyl urea tris sodium salt was reacted with [99mTc(I)(OH2)3(CO)3] Cl to yield the final N-{4-[99mTc(I)-tricarbonyl-N,N-bis-(carboxymethyl)-aminoethyl)-5-chloro-benzene-carboxamidoethyl]-benzene-sulfonyl}-N'-cyclo-hexyl-urea sodium salt in 70% RCY.
Resumo:
Vergleich von Datensätzen,die mit Hilfe von den Programmen "Volume©","Pulmo©", "Yacta©" und PulmoFUNC(ILab) erstellt wurden. Dabei wurden jeweils die Lungen- und Emphysemvolumina verglichen, die mit den 4 Programmen ermittelt wurden. Außerdem wurde noch die mittlere Lungendichte als Mittelwert aller Lungenvoxel bestimmt. Zusätzlich wurde noch der Emphysemindex als Quotient aus Emphysem- und Lungenvolumina errechnet. Die Programme waren unterschiedlich benutzerfreundlich in der Bearbeitung: Die weitestgehend manuell zu bearbeitenden Programme Volume© und Pulmo© benötigten zur Bearbeitung deutlich mehr Zeit als die überwiegend automatisch arbeitenden Programme Yacta und PulmoFUNC(ILab).
Resumo:
Radiometals play an important role in nuclear medicine as involved in diagnostic or therapeutic agents. In the present work the radiochemical aspects of production and processing of very promising radiometals of the third group of the periodic table, namely radiogallium and radiolanthanides are investigated. The 68Ge/68Ga generator (68Ge, T½ = 270.8 d) provides a cyclotron-independent source of positron-emitting 68Ga (T½ = 68 min), which can be used for coordinative labelling. However, for labelling of biomolecules via bifunctional chelators, particularly if legal aspects of production of radiopharmaceuticals are considered, 68Ga(III) as eluted initially needs to be pre-concentrated and purified. The first experimental chapter describes a system for simple and efficient handling of the 68Ge/68Ga generator eluates with a cation-exchange micro-chromatography column as the main component. Chemical purification and volume concentration of 68Ga(III) are carried out in hydrochloric acid – acetone media. Finally, generator produced 68Ga(III) is obtained with an excellent radiochemical and chemical purity in a minimised volume in a form applicable directly for the synthesis of 68Ga-labelled radiopharmaceuticals. For labelling with 68Ga(III), somatostatin analogue DOTA-octreotides (DOTATOC, DOTANOC) are used. 68Ga-DOTATOC and 68Ga-DOTANOC were successfully used to diagnose human somatostatin receptor-expressing tumours with PET/CT. Additionally, the proposed method was adapted for purification and medical utilisation of the cyclotron produced SPECT gallium radionuclide 67Ga(III). Second experimental chapter discusses a diagnostic radiolanthanide 140Nd, produced by irradiation of macro amounts of natural CeO2 and Pr2O3 in natCe(3He,xn)140Nd and 141Pr(p,2n)140Nd nuclear reactions, respectively. With this produced and processed 140Nd an efficient 140Nd/140Pr radionuclide generator system has been developed and evaluated. The principle of radiochemical separation of the mother and daughter radiolanthanides is based on physical-chemical transitions (hot-atom effects) of 140Pr following the electron capture process of 140Nd. The mother radionuclide 140Nd(III) is quantitatively absorbed on a solid phase matrix in the chemical form of 140Nd-DOTA-conjugated complexes, while daughter nuclide 140Pr is generated in an ionic species. With a very high elution yield and satisfactory chemical and radiolytical stability the system could able to provide the short-lived positron-emitting radiolanthanide 140Pr for PET investigations. In the third experimental chapter, analogously to physical-chemical transitions after the radioactive decay of 140Nd in 140Pr-DOTA, the rapture of the chemical bond between a radiolanthanide and the DOTA ligand, after the thermal neutron capture reaction (Szilard-Chalmers effect) was evaluated for production of the relevant radiolanthanides with high specific activity at TRIGA II Mainz nuclear reactor. The physical-chemical model was developed and first quantitative data are presented. As an example, 166Ho could be produced with a specific activity higher than its limiting value for TRIGA II Mainz, namely about 2 GBq/mg versus 0.9 GBq/mg. While free 166Ho(III) is produced in situ, it is not forming a 166Ho-DOTA complex and therefore can be separated from the inactive 165Ho-DOTA material. The analysis of the experimental data shows that radionuclides with half-life T½ < 64 h can be produced on TRIGA II Mainz nuclear reactor, with specific activity higher than any available at irradiation of simple targets e.g. oxides.
Resumo:
Die zuverlässige Berechnung von quantitativen Parametern der Lungenventilation ist für ein Verständnis des Verhaltens der Lunge und insbesondere für die Diagnostik von Lungenerkrankungen von großer Bedeutung. Nur durch quantitative Parameter sind verlässliche und reproduzierbare diagnostische Aussagen über den Gesundheitszustand der Lunge möglich. Im Rahmen dieser Arbeit wurden neue quantitative Verfahren zur Erfassung der Lungenventilation basierend auf der dynamischen Computer- (CT) und Magnetresonanztomographie (MRT) entwickelt. Im ersten Teil dieser Arbeit wurde die Frage untersucht, ob das Aufblähen der Lunge in gesunden Schweinelungen und Lungen mit Akutem Lungenversagen (ARDS) durch einzelne, diskrete Zeitkonstanten beschrieben werden kann, oder ob kontinuierliche Verteilungen von Zeitkonstanten die Realität besser beschreiben. Hierzu wurden Serien dynamischer CT-Aufnahmen während definierter Beatmungsmanöver (Drucksprünge) aufgenommen und anschließend aus den Messdaten mittels inverser Laplace-Transformation die zugehörigen Verteilungen der Zeitkonstanten berechnet. Um die Qualität der Ergebnisse zu analysieren, wurde der Algorithmus im Rahmen von Simulationsrechnungen systematisch untersucht und anschließend in-vivo an gesunden und ARDS-Schweinelungen eingesetzt. Während in den gesunden Lungen mono- und biexponentielle Verteilungen bestimmt wurden, waren in den ARDS-Lungen Verteilungen um zwei dominante Zeitkonstanten notwendig, um die gemessenen Daten auf der Basis des verwendeten Modells verlässlich zu beschreiben. Es wurden sowohl diskrete als auch kontinuierliche Verteilungen gefunden. Die CT liefert Informationen über das solide Lungengewebe, während die MRT von hyperpolarisiertem 3He in der Lage ist, direkt das eingeatmete Gas abzubilden. Im zweiten Teil der Arbeit wurde zeitlich hochaufgelöst das Einströmen eines 3He-Bolus in die Lunge erfasst. Über eine Entfaltungsanalyse wurde anschließend das Einströmverhalten unter Idealbedingungen (unendlich kurzer 3He-Bolus), also die Gewebeantwortfunktion, berechnet und so eine Messtechnik-unabhängige Erfassung des Einströmens von 3He in die Lunge ermöglicht. Zentrale Fragestellung war hier, wie schnell das Gas in die Lunge einströmt. Im Rahmen von Simulationsrechnungen wurde das Verhalten eines Entfaltungsalgorithmus (basierend auf B-Spline Repräsentationen) systematisch analysiert. Zusätzlich wurde ein iteratives Entfaltungsverfahren eingesetzt. Aus zeitlich hochaufgelösten Messungen (7ms) an einer gesunden und einer ARDS-Schweinelunge konnte erstmals nachgewiesen werden, dass das Einströmen in-vivo in weniger als 0,1s geschieht. Die Ergebnisse zeigen Zeitkonstanten im Bereich von 4ms–50ms, wobei zwischen der gesunden Lungen und der ARDS-Lunge deutliche Unterschiede beobachtet wurden. Zusammenfassend ermöglichen daher die in dieser Arbeit vorgestellten Algorithmen eine objektivere Bestimmung quantitativer Parameter der Lungenventilation. Dies ist für die eindeutige Beschreibung ventilatorischer Vorgänge in der Lunge und somit für die Lungendiagnostik unerlässlich. Damit stehen quantitative Methoden für die Lungenfunktionsdiagnostik zur Verfügung, deren diagnostische Relevanz im Rahmen wissenschaftlicher und klinischer Studien untersucht werden kann.
Resumo:
Auf der Suche nach dem „vulnerablen Plaque“, der ein besonders hohes Risiko für Schlaganfall und Herzinfarkt besitzt, findet momentan ein Paradigmenwechsel statt. Anstelle des klassischen Stenosegrades gewinnt die Darstellung der Plaquemorphologie zunehmend an Bedeutung. Fragestellung: Ziel dieser Arbeit ist es, die Fähigkeiten eines modernen 16-Kanal-CT hinsichtlich der Auflösung des Plaqueinneren bei Atherosklerose der Karotiden zu untersuchen und den Halo-Effekt in vivo zu erforschen. Methoden: Für die Studie wurden von 28 Patienten mit bekannter, symptomatischer Karotisstenose vor der gefäßchirurgischen Intervention CT-Bilder angefertigt, die nachfolgend mit der Histologie der Gefäßpräparate korreliert wurden. Auf diese Weise konnten die mikroskopisch identifizierten Lipidkerne im CT-Bild eingezeichnet und hinsichtlich ihrer Fläche und Dichtewerte evaluiert werden. In einem weiteren Schritt führten 2 Radiologen in Unkenntnis der histologischen Ergebnisse unabhängig voneinander eine Befundung durch und markierten mutmaßliche Lipidkerne. Zudem wurden sowohl in der verblindeten als auch in der histologiekontrollierten Auswertung die Plaquetypen anhand der AHA-Klassifikation bestimmt. Ein dritter Befundungsdurchgang geschah unter Zuhilfenahme einer von uns entwickelten Software, die CT-Bilder farbkodiert um die Detektion der Lipidkerne zu verbessern. Anhand der Farbkodierung wurde zudem ein Indexwert errechnet, der eine objektive Zuordnung zur AHA-Klassifikation ermöglichen sollte. Von 6 Patienten wurde zusätzlich noch eine native CT-Aufnahme angefertigt, die durch MPR exakt an die Kontrastmittelserie angeglichen wurde. Auf diese Weise konnte der Halo-Effekt, der die Plaqueanteile im lumennahen Bereich überstrahlt, quantifiziert und charakterisiert werden. Ergebnisse: Während die Einstufung in die AHA-Klassifikation sowohl durch den Befunder als auch durch den Softwarealgorithmus eine hohe Korrelation mit der Histologie aufweist (Typ IV/Va: 89 %, Typ Vb: 70 %, Typ Vc: 89 %, Typ VI: 55 %), ist die Detektion der Lipidkerne in beiden Fällen nicht ausreichend gut und die Befunderabhängigkeit zu groß (Cohens Kappa: 18 %). Eine Objektivierung der AHA-Klassifikation der Plaques durch Indexberechnung nach Farbkodierung scheint möglich, wenn auch dem Befunder nicht überlegen. Die fibröse Kappe kann nicht abgegrenzt werden, da Überstrahlungseffekte des Kontrastmittels dessen HU-Werte verfälschen. Dieser Halo-Effekt zeigte sich im Median 1,1 mm breit mit einer Standardabweichung von 0,38 mm. Eine Abhängigkeit von der Kontrastmitteldichte im Gefäßlumen konnte dabei nicht nachgewiesen werden. Der Halo-Effekt fiel im Median um -106 HU/mm ab, bei einer Standardabweichung von 33 HU/mm. Schlussfolgerung: Die CT-Technologie zeigt sich, was die Darstellung von einzelnen Plaquekomponenten angeht, den bekannten Fähigkeiten der MRT noch unterlegen, insbesondere in Bezug auf die fibröse Kappe. Ihre Fähigkeiten liegen bisher eher in der Einstufung von Plaques in eine grobe Klassifikation, angelehnt an die der AHA. Die klinische Relevanz dessen jedoch gilt es in Zukunft in größeren Studien weiter zu untersuchen. Auch lässt die Weiterentwicklung der Computertomographie auf eine zukünftig höhere Auflösung der Plaquemorphologie hoffen.
Resumo:
This master’s thesis describes the research done at the Medical Technology Laboratory (LTM) of the Rizzoli Orthopedic Institute (IOR, Bologna, Italy), which focused on the characterization of the elastic properties of the trabecular bone tissue, starting from october 2012 to present. The approach uses computed microtomography to characterize the architecture of trabecular bone specimens. With the information obtained from the scanner, specimen-specific models of trabecular bone are generated for the solution with the Finite Element Method (FEM). Along with the FEM modelling, mechanical tests are performed over the same reconstructed bone portions. From the linear-elastic stage of mechanical tests presented by experimental results, it is possible to estimate the mechanical properties of the trabecular bone tissue. After a brief introduction on the biomechanics of the trabecular bone (chapter 1) and on the characterization of the mechanics of its tissue using FEM models (chapter 2), the reliability analysis of an experimental procedure is explained (chapter 3), based on the high-scalable numerical solver ParFE. In chapter 4, the sensitivity analyses on two different parameters for micro-FEM model’s reconstruction are presented. Once the reliability of the modeling strategy has been shown, a recent layout for experimental test, developed in LTM, is presented (chapter 5). Moreover, the results of the application of the new layout are discussed, with a stress on the difficulties connected to it and observed during the tests. Finally, a prototype experimental layout for the measure of deformations in trabecular bone specimens is presented (chapter 6). This procedure is based on the Digital Image Correlation method and is currently under development in LTM.