899 resultados para Residual monomer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Especialidad en Cirugía General). U. A. N. L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias con Especialidad en Ingeniería Ambiental) U.A.N.L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestro en Ciencias de la Ingeniería Eléctrica con Especialidad en Control) - Universidad Autónoma de Nuevo León, 2000

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestro en Ciencias con Especialidad en Microbiología) U.A.N.L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias de la Ingeniería Mecánica con Orientación en Procesos Sustentables) UANL, 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Doctor en Ciencias Agrícolas con Especialidad en Agua-Suelo) U.A.N.L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les nanoparticules (NPs) de polymère ont montré des résultats prometteurs pour leur utilisation comme système de transport de médicaments pour une libération contrôlée du médicament, ainsi que pour du ciblage. La biodisponibilité des médicaments administrés oralement pourrait être limitée par un processus de sécrétion intestinale, qui pourrait par la suite être concilié par la glycoprotéine P (P-gp). La dispersion de la Famotidine (modèle de médicament) à l’intérieur des nanoparticules (NPs) pegylées a été évaluée afin d’augmenter la biodisponibilité avec du polyéthylène glycol (PEG), qui est connu comme un inhibiteur de P-gp. L’hypothèse de cette étude est que l’encapsulation de la Famotidine (un substrat de P-gp) à l’intérieur des NPs préparées à partir de PEG-g-PLA pourrait inhiber la fonction P-gp. La première partie de cette étude avait pour but de synthétiser quatre copolymères de PEG greffés sur un acide polylactide (PLA) et sur un squelette de polymère (PLA-g-PEG), avec des ratios de 1% et 5% (ratio molaire de PEG vs acide lactique monomère) de soit 750, soit 2000 Da de masse moléculaire. Ces polymères ont été employés afin de préparer des NPs chargés de Famotidine qui possède une faible perméabilité et une solubilité aqueuse relativement basse. Les NPs préparées ont été analysées pour leur principaux paramètres physicochimiques tels que la taille et la distribution de la taille, la charge de surface (Potentiel Zeta), la morphologie, l’efficacité d’encapsulation, le pourcentage résiduel en alcool polyvinylique (PVA) adsorbé à la surface des NPs, les propriétés thermiques, la structure cristalline et la libération du médicament. De même, les formules de NPs ont été testées in vitro sur des cellules CaCo-2 afin dʼévaluer la perméabilité bidirectionnelle de la Famotidine. Généralement, les NPs préparées à partir de polymères greffés PLA-g-5%PEG ont montré une augmentation de la perméabilité du médicament, ce par l’inhibition de l’efflux de P-gp de la Famotidine dans le modèle CaCo-2 in vitro. Les résultats ont montré une baisse significative de la sécrétion de la Famotidine de la membrane basolatéral à apical lorsque la Famotidine était encapsulée dans des NPs préparées à partir de greffes de 5% PEG de 750 ou 2000 Da, de même que pour d’autres combinaisons de mélanges physiques contenant du PEG5%. La deuxième partie de cette étude est à propos de ces NPs chargées qui démontrent des résultats prometteurs en termes de perméabilité et d’inhibition d’efflux de P-gp, et qui ont été choises pour développer une forme orale solide. La granulation sèche a été employée pour densifier les NPs, afin de développer des comprimés des deux formules sélectionnées de NPs. Les comprimés à base de NPs ont démontré un temps de désintégration rapide (moins d’une minute) et une libération similaire à la Famotidine trouvée sur le marché. Les résultats de l’étude du transport de comprimés à base de NPs étaient cohérents avec les résultats des formules de NPs en termes d’inhibition de P-gp, ce qui explique pourquoi le processus de fabrication du comprimé n’a pas eu d’effet sur les NPs. Mis ensemble, ces résultats montrent que l’encapsulation dans une NP de polymère pegylé pourrait être une stratégie prometteuse pour l’amélioration de la biodisponibilité des substrats de P-gp.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study on the characterization of probability distributions using the residual entropy function. The concept of entropy is extensively used in literature as a quantitative measure of uncertainty associated with a random phenomenon. The commonly used life time models in reliability Theory are exponential distribution, Pareto distribution, Beta distribution, Weibull distribution and gamma distribution. Several characterization theorems are obtained for the above models using reliability concepts such as failure rate, mean residual life function, vitality function, variance residual life function etc. Most of the works on characterization of distributions in the reliability context centers around the failure rate or the residual life function. The important aspect of interest in the study of entropy is that of locating distributions for which the shannon’s entropy is maximum subject to certain restrictions on the underlying random variable. The geometric vitality function and examine its properties. It is established that the geometric vitality function determines the distribution uniquely. The problem of averaging the residual entropy function is examined, and also the truncated form version of entropies of higher order are defined. In this study it is established that the residual entropy function determines the distribution uniquely and that the constancy of the same is characteristics to the geometric distribution

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of residual cations in rare earth metal modified faujasite–Y zeolite has been monitored using magic angle spinning NMR spectral analysis and catalytic activity studies. The second metal ions being used are Na+, K+ and Mg+. From a comparison of the spectra of different samples, it is concluded that potassium and magnesium exchange causes a greater downfield shift in the 29Si NMR peaks. Also, lanthanum exchanged samples show migration behavior from large cages to small cages, which causes the redistribution of second counter cations. It is also observed that Mg2+ causes the most effective migration of lanthanum ions due to its greater charge. The prepared systems were effectively employed for the alkylation of benzene with 1-octene in the vapor phase. From the deactivation studies it is observed that the as-exchanged zeolites possess better stability towards reaction condition over the pure HFAU zeolite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was conducted to identify the concentration dependence of the operating wavelengths and the relative intensities in which a dye mixture doped polymer optical fibre can operate. A comparative study of the radiative and Forster type energy transfer processes in Coumarin 540:Rhodamine 6G, Coumarin 540:Rhodamine B and Rhodamine 6G:Rhodamine B in methyl methacrylate (MMA) and poly(methyl methacrylate) (PMMA) was done by fabricating a series of dye mixture doped polymer rods which have two emission peaks with varying relative intensities. These rods can be used as preforms for the fabrication of polymer optical fibre amplifiers operating in the multi-wavelength regime. The 445 nm line from an Nd:YAG pumped optical parametric oscillator (OPO) was used as the excitation source for the first two dye pairs and a frequency doubled Nd:YAG laser emitting at 532 nm was used to excite the Rh 6G:Rh B pair. The fluorescence lifetimes of the donor molecule in pure form as well as in the mixtures were experimentally measured in both monomer and polymer matrices by time-correlated single photon counting technique. The energy transfer rate constants and transfer efficiencies were calculated and their dependence on the acceptor concentration was analysed. It was found that radiative energy transfer mechanisms are more efficient in all the three dye pairs in liquid and solid matrices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Investigations on the fracture behaviour of polymer blends is the topic of this thesis. The blends selected are PP/HDPE and PS/HIPS. PP/HDPE blend is chosen due to its commercial importance and PS/HIPS blend is selected to study the transition from brittle fracture to ductile fracture.PP/HDPE blends were prepared at different compositions by melt blending at 180°C and fracture failure process was investigated by conducting notch sensitivity test and tensile test at different strain rates. The effects of two types of modifiers (particulate and elastomer) on the fracture behaviour and notch sensitivity of PP/HDPE blends were studied. The modifiers used are calcium carbonate, a hard particulate filler commonly used in plastics and Ethylene Propylene Diene Monomer (EPDM). They were added in 2%, 4% and 6% by weight of the blends.The study shows that the mechanical properties of PP/HDPE blends can be optimized by selecting proper blend compositions. The selected modifiers are found to alter and improve the fracture behaviour and notch sensitivity of the blends. Particulate fillers like calcium carbonate can be used for making the mechanical behaviour more stable at the various blend compositions. The resistance to notch sensitivity of the blends is found to be marginally lower in the presence of calcium carbonate. The elastomeric modifier EPDM produces a better stability of the mechanical behaviour. A low concentration of EPDM is sufficient to effect such a change. EPDM significantly improves the resistance to notch sensitivity of the blends. The study shows that judicious selection of modifiers can improve the fracture behaviour and notch sensitivity of PP/HDPE blends and help these materials to be used for critical applications.For investigating the transition in fracture behaviour and failure modes, PS/HIPS blends were selected. The blends were prepared by melt mixing followed by injection moulding to prepare the specimens for conducting tensile, impact and flexure tests. These tests were used to simulate the various conditions which promote failure.The tensile behaviour of unnotched and notched PS/HIPS blend samples were evaluated at slow speeds. Tensile strengths and moduli were found to increase at the higher testing speed for all the blend combinations whereas maximum strain at break was found to decrease. For a particular speed of testing, the tensile strength and modulus show only a very slight decrease as HIPS content is increased up to about 40%. However, there is a drastic decrease on increasing the HIPS content thereafter.The maximum strain at break shows only a very slight change up to about 40% HIPS content and thereafter shows a remarkable increase. The notched specimens also follow a comparable trend even though the notch sensitivity is seen high for PS rich blends containing up to 40% HIPS. The notch sensitivity marginally decreases with increase in HIPS content. At the same time, it is found to increase with the increase in strain rate. It is observed that blends containing more than 40% HIPS fail in ductile mode.The impact characteristics of PSIHIPS blends studied were impact strength, the energy absorbed by the test specimen and impact toughness. Remarkable increase in impact strength is observed as HIPS content in the blend exceeds 40%. The energy absorbed by the test specimens and the impact toughness also show a comparable trend.Flexural testing which helps to characterize the load bearing capacity was conducted on PS/HIPS blend samples at the two different testing speeds of 5mmlmin and 10 mm/min. The flexural strength increases with increase in testing speed for all the blend compositions. At both the speeds, remarkable reduction in flexural strength is observed as HIPS content in the blend exceeds 40%. The flexural strain and flexural energy absorbed by the specimens are found to increase with increase in HIPS content. At both the testing speeds, brittle fracture is observed for PS rich blends whereas HIPS rich blends show ductile mode of failure.Photoelastic investigations were conducted on PS/HIPS blend samples to analyze their failure modes. A plane polariscope with a broad source of light was utilized for the study. The coloured isochromatic fringes formed indicate the presence of residual stress concentration in the blend samples. The coverage made by the fringes on the test specimens varies with the blend composition and it shows a reducing trend with the increase in HIPS content. This indicates that the presence of residual stress is a contributing factor leading to brittle fracture in PS rich blends and this tendency gradually falls with increase in HIPS content and leads to their ductile mode of failure.