896 resultados para Refinery treated effluent
Resumo:
Twenty-seven mycologically proven cases of paracoccidioidomycosis (PCM) were treated with itraconazole (100-200 mg/day in month 1 and 100 mg/day until month 6-8) and evaluated clinically and serologically, up to 3.5 years post-therapy, using Dot-blot and ELISA for measuring the titers of IgG, IgA and IgM anti-P. brasiliensis antibodies and Western-blot for determining IgG, IgA and IgM antibodies against the antigen components of the fungus. Before treatment, 81.5% (Dot-blot) and 84% (ELISA) of the patients presented elevated IgG anti-P. brasiliensis antibody titers which dropped slightly with treatment. On the other hand, the percentages of pre-treatment high-titered sera for IgA and IgM anti-P.brasiliensis were lower (5l.9% and 5l.8%: Dot-blot; 16.5 and 36%: ELISA, respectively) but the titers tended to become negative more frequently with treatment. Prior to treatment, the percentages of positivity for IgG, IgA and IgM anti-P.brasiliensis antibodies in Western-blot were 96%, 20.8% and 41.6%, respectively. Antigens with molecular weights varying from 16-78 kDa, from 21-76 kDa and from 27-78 kDa were reactive for IgG, IgA and IgM antibodies, respectively. The most frequently reactive antigenic components had molecular weights of 27, 33 and 43 kDa for IgG, and 70 for IgA and IgM antibodies. During the period of study, the patients responded well to treatment. The present data confirm the diversity and complexity of the humoral response in PCM, and the importance of utilizing different serological tests to detect IgG, IgA and IgM anti-P. brasiliensis antibodies
Resumo:
Nesta dissertação pretendeu-se estudar a viabilidade do uso de eletrodiálise com membranas bipolares (BM) na recuperação de ácido clorídrico e de hidróxido de sódio a partir de um efluente industrial que contém 1.4 mol/L de cloreto de sódio. Estas membranas mostraram ser uma ferramenta eficiente para a produção de ácidos e bases a partir do respetivo sal. Foi feita uma seleção de diferentes membranas bipolares (Neosepta, Fumatech e PCA) e aniónicas (PC-SA e PC-ACID 60) na tentativa de encontrar a combinação mais adequada para o tratamento do efluente. Dependendo do critério, o melhor arranjo de membranas é o uso de PC-ACID 60 (membrana aniónica), PC-SK (membrana catiónica) e membranas bipolares do tipo Neosepta para maior pureza dos produtos; membranas bipolares Fumatech para maior eficiência de dessalinização e membranas bipolares PCA para um maior grau de dessalinização. Tecnologicamente foi possível obter uma dessalinização de 99.8% em quatro horas de funcionamento em modo batch com recirculação de todas as correntes. Independentemente da combinação usada é recomendável que o processo seja parado quando a densidade de corrente deixa de ser máxima, 781 A/m2. Assim é possível evitar o aumento de impurezas nos produtos, contra difusão, descida instantânea do pH e uma dessalinização pouco eficiente. A nível piloto o principal fornecedor de membranas e unidade de tratamento “stack” é a marca alemã PCA. Sendo assim realizaram-se ensaios de repetibilidade, contra difusão, avaliação económica e upscaling utilizando as membranas bipolares PCA. A nível económico estudou-se o uso de dois tipos de unidades de tratamento; EDQ 380 e EDQ 1600, para diferentes níveis de dessalinização (50, 75 e 80%). Tendo em conta a otimização económica, é recomendável uma dessalinização máxima de 80%, uma vez que a eficiência de processo a este ponto é de 40%. A aplicação do método com a unidade EDQ 1600 para uma dessalinização de 50% é a mais vantajosa economicamente, com custos de 16 €/m3 de efluente tratado ou 0,78 €/kg Cl- removido. O número de unidades necessárias é 4 posicionados em série.
Resumo:
Evolução, ato ou efeito de evoluir, sequência de transformações, desenvolvimento progressivo. Se tudo à nossa volta se transforma, a indústria tem de acompanhar esse sistema evolutivo, tornando assim imprescindível alterar ou melhorar processos de produção quando estes não se enquadram com a realidade, ou porque o mercado se altera, ou porque as necessidades mudam, ou por simplesmente ser mais rentável. Sendo a Galp Energia uma empresa que se encontra sempre na vanguarda da evolução tecnológica, encontra no Departamento de Engenharia Química do Instituto Superior de Engenharia do Porto um aliado na procura do melhor modo de valorizar os seus produtos. A Refinaria de Matosinhos tem atualmente duas correntes de gasolina leve e uma de refinado que apresentam grande potencialidade de valorização. Parte destas correntes incorporam atualmente a pool de nafta química da refinaria que é vendida à Repsol Polímeros. O desafio que é proposto baseia-se em valorizar essas correntes através da sua isomerização aumentando o seu RON podendo então ter como fim a pool de gasolinas. Tirando partido da tecnologia disponível para este efeito são apresentados quatro cenários de possíveis soluções. Sendo os dois primeiros excluídos por violarem restrições impostas, o terceiro e quarto cenários foram analisados de um ponto de vista económico. O terceiro cenário conduz a gasolina leve da Fábrica de Aromáticos para a pool de gasolinas sem qualquer tratamento e a gasolina leve da Fábrica de Combustíveis continua a integrar a pool de nafta química. O refinado da Fábrica de Aromáticos será enviado para um splitter, sendo a corrente de topo destinada à pool de nafta química e a corrente de fundo enviada a um reator de isomerização, Isomalk-4SM, passando previamente por uma torre de argila de forma a assegurar que a restrição em teor de olefinas no reator não é violada. O efluente, com RON maior, integrará igualmente a pool de gasolinas. No quarto cenário a corrente de refinado da Fábrica de Aromáticos não sofre qualquer tratamento, continuando a alimentar a unidade de solventes, a gasolina leve da Fábrica de Aromáticos irá diretamente para a pool de gasolinas e a gasolina leve da Fábrica de Combustíveis passará pelo Isomalk-2SM para aumentar o índice de octanos garantido assim ter condições de integrar a pool de gasolinas. Dissertação de Mestrado em Engenharia Química Isomerização de Gasolina Leve O terceiro cenário apresenta um aumento de 4 576 773 € anuais nas receitas e o quarto alcança 11 333 982 € anuais. O investimento inicial total do terceiro cenário é de 28 821 608 € quando o quarto cenário carece de um investimento inicial de apenas 18 028 349 €. Quanto aos custos associados à implementação da unidade estes demonstram-se elevados, o terceiro cenário apresenta um custo de 23 133 429 € enquanto o do quarto cenário é de 13 998 797 €. O quarto cenário apresenta-se assim como a solução mais rentável para o objetivo desta dissertação.
Resumo:
O presente trabalho, efetuado na Estação de Tratamento de Águas Residuais do Freixo (ETAR do Freixo), decorreu durante um período de nove meses, (entre Dezembro de 2012 e Agosto de 2013), e teve como principais objetivos: - a observação microscópica e respetiva identificação dos organismos presentes nas lamas ativadas dos reatores biológicos da ETAR (incidindo nos protozoários, metazoários e bactérias filamentosas); - estabelecer a relação entre os organismos identificados/quantidade respetiva e a sedimentabilidade das lamas ativadas e sua influência no processo de depuração; - avaliar a variação das espécies identificadas com as alterações processuais. Para o efeito, a metodologia utilizada foi: - a colheita diária de amostras em vários pontos da ETAR; - a determinação dos parâmetros operacionais e caracterização das amostras recolhidas, tendo sido efetuadas 6039 análises físico-químicas, incluindo ao afluente à ETAR, ao afluente e ao conteúdo dos dois reatores biológicos, à corrente de recirculação de lamas e ao efluente; - a visualização diária microscópica ótica sem contraste de fase dos microrganismos presentes nos reatores biológicos; - a visualização microscópica ótica com contraste de fase da microfauna presente nos reatores biológicos, sendo efetuadas 16 identificações e quantificações dos protozoários presentes nas lamas ativadas dos dois reatores e 10 identificações e quantificações das bactérias filamentosas presentes nos dois reatores biológicos. O início do estudo ocorreu num período em que se começou a verificar um aumento excessivo de espumas nos decantadores secundários, resultando numa fraca sedimentabilidade das lamas e numa menor qualidade do efluente final. Na tentativa de reduzir a excessiva ascensão do manto de lamas que se verificou, foram efectuadas alterações operacionais, consistindo: - na alteração da razão de recirculação da decantação secundária para os reatores biológicos; - na introdução de um composto altamente concentrado em matéria orgânica na corrente de recirculação de lamas; - na alteração da extração de lamas biológicas. Verificou-se que as alterações processuais efetuadas foram muito eficazes na diminuição do manto de lamas da decantação secundária, bem como muito eficazes na qualidade do efluente final. Durante os meses de Fevereiro a Agosto fez-se o acompanhamento diário de todas as condições de operação de modo a manter e validar o procedimento de operação, o qual se considerou muito eficaz em termos de obtenção de uma água tratada de excelente qualidade. Durante o estudo efetuado, verificou-se que a população microbiológica existente nos dois reatores biológicos se manteve praticamente inalterada durante todo o período, sendo os móveis de fundo e os sésseis os grupos dominantes. Esta dominância traduziu-se na elevada qualidade do efluente final que se observou a partir do mês de Fevereiro, tendo dificultado o estudo de novas condições de operação, mas facilitando a validação do procedimento adotado. No que se refere às bactérias filamentosas, verificou-se que são diversas as espécies presentes nos reatores biológicos e que existem em grande abundância, sendo que o Tipo 0092 é claramente dominante. O excessivo crescimento deste tipo de bactérias mostrou ser o maior problema a nível microbiológico no processo de tratamento da instalação, tornando-se crítico no período de inverno em que a temperatura e os picos de pluviosidade se mostraram condições favoráveis ao seu desenvolvimento. Para além da temperatura outros fatores mostraram-se responsáveis pelo seu crescimento tais como a razão Alimento/Microrganismo (A/M), a idade das lamas, a carga mássica afluente e o teor de oxigénio dissolvido nos reatores biológicos. Pode-se concluir que apesar de não se trabalhar com os valores teóricos dos parâmetros microbiológicos e operacionais considerados ideais, a ETAR do Freixo, possui um tratamento bastante eficaz na remoção da carga orgânica, na remoção de nutrientes e na remoção de sólidos suspensos totais, apesar da não existência de uma etapa de afinação final como a filtração.
Resumo:
The aim of this work was to compare the evolution of chronic chagasic untreated patients (UTPs) with that of benznidazole or nifurtimox-treated patients (TPs). A longitudinal study from a low endemic area (Santa Fe city, Argentina) was performed during an average period of 14 years. Serological and parasitological analyses with clinical exams, ECG and X-chest ray were carried out. At the onset, 19/198 infected patients showed chagasic cardiomyopathy (CrChM) while 179 were asymptomatic. In this latter group the frequency of CrChM during the follow-up was lower in TPs compared with UTPs (3.2% vs 7%). Within the CrChM group, 2/5 TPs showed aggravated myopathy whereas this happened in 9/14 UTPs. Comparing the clinical evolution of all patients, 5.9% of TPs and 13% of UTPs had unfavourable evolution, but the difference is not statistically relevant. Serological titers were assessed by IIF. Titers equal to or lower than 1/64 were obtained in 86% of the TPs, but only in 38% of UTPs. The differences were statistically significant (geometric mean: 49.36 vs. 98.2). Antiparasitic assessment of the drugs (xenodiagnosis) proved to be effective. The low sensitivity in chronic chagasic patients must be born in mind. Despite treated patients showed a better clinical evolution and lower antibody levels than untreated ones, it is necessary to carry on doing research in order to improve therapeutic guidelines, according to the risk/benefit equation and based on scientific and ethical principles.
Resumo:
We used a molecular method and demonstrated that treatment of the chronic human Trypanosoma cruzi infections with nitroderivatives did not lead to parasitological cure. Seventeen treated and 17 untreated chronic Chagas' disease patients, with at least two out of three positive serologic assays for the infection, and 17 control subjects formed the study groups. PCR assays with nested sets of T. cruzi DNA primers monitored the efficacy of treatment. The amplification products were hybridized to their complementary internal sequences. Untreated and treated Chagas' disease patients yielded PCR amplification products with T. cruzi nuclear DNA primers. Competitive PCR was conducted to determine the quantity of parasites in the blood and revealed < 1 to 75 T. cruzi/ml in untreated (means 25.83 ± 26.32) and < 1 to 36 T. cruzi/ml in treated (means 6.45 ± 9.28) Chagas' disease patients. The difference between the means was not statistically significant. These findings reveal a need for precise definition of the role of treatment of chronic Chagas' disease patients with nitrofuran and nitroimidazole compounds.
Resumo:
Paracoccidioidomycosis (PCM) is a primary pulmonary infection that often disseminates to other organs and systems. Involvement of the central nervous system (CNS) is rare and due to the fact that both clinical alertness and establishment of the diagnosis are delayed, the disease progresses causing serious problems. We report here a case of neuroparacoccidioidomycosis (NPCM), observed in a 55 year-old male, who consulted due to neurological symptoms (left hemiparesis, paresthesias, right palpebral ptosis, headache, vomiting and tonic clonic seizures) of a month duration. Upon physical examination, an ulcerated granulomatous lesion was observed in the abdomen. To confirm the diagnosis a stereotactic biopsy was taken; additionally, mycological tests from the ulcerated lesion and a bronchoalveolar lavage were performed. In the latter specimens, P. brasiliensis yeast cells were visualized and later on, the brain biopsy revealed the presence of the fungus. Treatment with itraconazole (ITZ) was initiated but clinical improvement was unremarkable; due to the fact that the patient was taking sodium valproate for seizure control, drug interactions were suspected and confirmed by absence of ITZ plasma levels. The latter medication was changed to clonazepam and after several weeks, clinical improvement began to be noticed and was accompanied by diminishing P. brasiliensis antigen and antibody titers. In the PCM endemic areas, CNS involvement should be considered more often and the efficacy of itraconazole therapy should also be taken into consideration.
Resumo:
Rhinoentomophthoramycosis caused by Conidiobolus coronatus in a 61-year old woman was unsuccessfully treated during 8 years with all the antifungals available in the Brazilian market, including potassium iodide for 1 month, sulfamethoxazole plus trimethoprim for 2 months, amphotericin B, total dose of 1130 mg, cetoconazole, 400 mg/day for 6 months, fluconazole, 200 mg/day, for at least 2 months and, itraconazole, 400 mg/day for 2 months, followed by 200 mg/day for 4 more months. Complete clinical and mycological cure was achieved using itraconazol 400 mg/day in association with fluconazol 200 mg/day during 24 months. After cure she was submitted to plastic surgery to repair her facial deformation. Today she remains clinically and mycologically cured after 59/60 months (5 years!) without any specific antifungal. We thus suggest the use of the combination of itraconazole and fluconazole as an additional option for the treatment of this mycosis.
Resumo:
Renal transplant in highly sensitised patients is associated with increased morbidity. The aim of this retrospective study was to evaluate the clinical evolution of 30 highly sensitised deceased donor kidney transplants and the influence of different timing of B cell directed treatment and its importance in the outcome of these patients. All recipients had negative complement dependent lymphocytotoxicity cytotoxic T cell crossmatch and no identified anti human leucocyte antigen class I donor specific antibodies. T cell flow crossmatch was performed within 24h of transplantation with serum obtained pretransplant (historic, recent or baseline). Posttransplant flow crossmatch were performed prospectively starting on the 3rd posttransplantation day. The immunosuppressive regime included thymoglobulin, tacrolimus, mycofenolate mofetil and steroids. Positive flow crossmatch occurred in 20/29 patients by the 3rd posttransplantation day, and in 17/27 patients after the 3rd posttransplantation day. All patients were started on intravenous immunoglobulin before transplantation: in nine patients (group A) at 400mg/kg/day for five days; in the remaining 21 patients (group B), as a continued infusion of 2g/kg during 48h. In group A, Rituximab was added only in the presence of antibody mediated rejection; in group B, introduced on the 3rd posttransplantation day whenever a positive flow crossmatch (with serum obtained pre or posttransplant) was reported. Antibody mediated rejection was observed in 44.4% of patients in group A, and 19% of those in group B. Mean follow-up was 12.2±5.5 months. Overall allograft survival was 76.6%, 81% in group B, and 66.6% in group A. At last follow up, mean serum creatinine was 1.3±0.6 mg/dl. Renal transplantation with pretransplant positive flow crossmatch is highly associated with antibody mediated rejection, despite introduction of intravenous immunoglobulin pretransplantation. However high dose intravenous immunoglobulin for 48h plus Rituximab by the 3rd posttransplantation day reduce the incidence of antibody mediated rejection by more than 50% and allowed for allograft survival of 81% at one year, with an excellent renal function.
Resumo:
O tratamento das águas residuais domésticas surge com o intuito de degradar os poluentes presentes, para que as águas residuais tratadas não prejudiquem o ambiente nem a saúde pública. O presente trabalho teve como objetivo a conceção e o dimensionamento de uma Estação de Tratamento de Águas Residuais (ETAR) na freguesia de Canelas com a finalidade de substituir a já existente e permitir a ampliação da área da rede de saneamento da freguesia. Foram considerados dois tipos de ETAR’s, compacta e convencional, para tratar águas residuais domésticas de aproxidamente 2000 habitantes, com um caudal médio de 400 m3/dia e um caudal de ponta de 1136,7 m3/dia. Das duas opções optou-se pela convencional uma vez que acarreta um menor investimento, no valor de 187 232 €, e se considera também mais adequada às características do efluente a tratar. O tratamento escolhido inclui inicialmente uma gradagem, com uma grade constituída por sete barras com um espaçamento de 20 mm entre elas, seguida de um tamisador rotativo com uma abertura de malha de 3 mm. Depois do tamisador, optou-se por um sistema de desarenação/desengorduramento com um volume do tanque de 3,95 m3 e um fluxo de ar de 17,9 m3/h. Na fase seguinte considerou-se um tratamento biológico por lamas ativadas em regime de arejamento prolongado num tanque de arejamento de volume igual a 245,8 m3 com um arejador submerso, seguindo-se um decantador secundário de volume 33,3 m3. Por último, escolheu-se um sistema de desinfeção por ultravioleta e, a montante do mesmo, um filtro rápido para eliminar pequenas partículas que o efluente ainda possa conter. Para a desinfeção foram consideradas duas secções com cinco módulos de duas lâmpadas cada, ou seja, vinte lâmpadas ultravioleta. Dos resíduos produzidos pelo tratamento da água residual, os gradados e as areias serão encaminhados para aterro, enquanto que as lamas serão enviadas para a ETAR das Termas de S.Vicente, para que sofram o tratamento adequado e sejam encaminhadas para o destinal final adequado (aplicação em solos agrícolas, compostagem ou em alternativa para aterro). No caso da ETAR covencional foi ainda avaliada a possível reutilização de um decantador da ETAR de Milhundos uma vez que esta se encontrava em fase de desativação. Desta avaliação, concluiu-se que não seria economicamente viável o seu reaproveitamento. Mestrado em Engenharia Química – Tecnologias de Proteção Ambiental Para além disso realizou-se também um levantamento dos principais problemas que ocorrem na maioria das ETAR’s e foram apresentadas as respetivas sugestões de resolução. A realização de um inquérito permititu concluir que os odores são o problema que mais causa incómodo à população.
Resumo:
We describe a case of white-grain eumycetoma caused by Scedosporium apiospermum in an immunocompetent host that was successfully treated with oral voriconazole, and we review the Brazilian reports on scedosporiosis.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente – Perfil de Engenharia Sanitária
Resumo:
Community-associated methicillin-resistant Staphylococcus aureus (CA-MRSA) is an emerging public health problem worldwide. Severe invasive infections have been described, mostly associated with the presence of Panton-Valentine leukocidin (PVL). In Portugal limited information exists regarding CA-MRSA infections. In this study we describe the case of a previously healthy 12-year-old female, sport athlete, who presented to the hospital with acetabulofemoral septic arthritis, myositis, fasciitis, acetabulum osteomyelitis, and pneumonia.The MRSA isolated from blood and synovial fluid was PVL negative and staphylococcal enterotoxin type P (SEP) and type L (SEL) positive, with a vancomycin MIC of 1.0mg/L and resistant to clindamycin and ciprofloxacin. The patient was submitted to multiple surgical drainages and started on vancomycin, rifampicin, and gentamycin. Due to persistence of fever and no microbiological clearance, linezolid was started with improvement. This is one of the few reported cases of severe invasive infection caused by CA-MRSA in Portugal,which was successfully treated with linezolid. In spite of the severity of infection, the MRSA isolate did not produce PVL.