999 resultados para Recherche linéaire


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statistics has become an indispensable tool in biomedical research. Thanks, in particular, to computer science, the researcher has easy access to elementary "classical" procedures. These are often of a "confirmatory" nature: their aim is to test hypotheses (for example the efficacy of a treatment) prior to experimentation. However, doctors often use them in situations more complex than foreseen, to discover interesting data structures and formulate hypotheses. This inverse process may lead to misuse which increases the number of "statistically proven" results in medical publications. The help of a professional statistician thus becomes necessary. Moreover, good, simple "exploratory" techniques are now available. In addition, medical data contain quite a high percentage of outliers (data that deviate from the majority). With classical methods it is often very difficult (even for a statistician!) to detect them and the reliability of results becomes questionable. New, reliable ("robust") procedures have been the subject of research for the past two decades. Their practical introduction is one of the activities of the Statistics and Data Processing Department of the University of Social and Preventive Medicine, Lausanne.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La collaboration CLIC (Compact LInear Collider, collisionneur linéaire compact) étudie la possibilité de réaliser un collisionneur électron-positon linéaire à haute énergie (3 TeV dans le centre de masse) et haute luminosité (1034 cm-2s-1), pour la recherche en physique des particules. Le projet CLIC se fonde sur l'utilisation de cavités accélératrices à haute fréquence (30 GHz). La puissance nécessaire à ces cavités est fournie par un faisceau d'électrons de basse énergie et de haute intensité, appelé faisceau de puissance, circulant parallèlement à l'accélérateur linéaire principal (procédé appelé « Accélération à Double Faisceau »). Dans ce schéma, un des principaux défis est la réalisation du faisceau de puissance, qui est d'abord généré dans un complexe accélérateur à basse fréquence, puis transformé pour obtenir une structure temporelle à haute fréquence nécessaire à l'alimentation des cavités accélératrices de l'accélérateur linéaire principal. La structure temporelle à haute fréquence des paquets d'électrons est obtenue par le procédé de multiplication de fréquence, dont la manipulation principale consiste à faire circuler le faisceau d'électrons dans un anneau isochrone en utilisant des déflecteurs radio-fréquence (déflecteurs RF) pour injecter et combiner les paquets d'électrons. Cependant, ce type de manipulation n'a jamais été réalisé auparavant et la première phase de la troisième installation de test pour CLIC (CLIC Test Facility 3 ou CTF3) a pour but la démonstration à faible charge du procédé de multiplication de fréquence par injection RF dans un anneau isochrone. Cette expérience, qui a été réalisée avec succès au CERN au cours de l'année 2002 en utilisant une version modifiée du pré-injecteur du grand collisionneur électron-positon LEP (Large Electron Positron), est le sujet central de ce rapport. L'expérience de combinaison des paquets d'électrons consiste à accélérer cinq impulsions dont les paquets d'électrons sont espacés de 10 cm, puis à les combiner dans un anneau isochrone pour obtenir une seule impulsion dont les paquets d'électrons sont espacés de 2 cm, multipliant ainsi la fréquence des paquets d'électrons, ainsi que la charge par impulsion, par cinq. Cette combinaison est réalisée au moyen de structures RF résonnantes sur un mode déflecteur, qui créent dans l'anneau une déformation locale et dépendante du temps de l'orbite du faisceau. Ce mécanisme impose plusieurs contraintes de dynamique de faisceau comme l'isochronicité, ainsi que des tolérances spécifiques sur les paquets d'électrons, qui sont définies dans ce rapport. Les études pour la conception de la Phase Préliminaire du CTF3 sont détaillées, en particulier le nouveau procédé d'injection avec les déflecteurs RF. Les tests de haute puissance réalisés sur ces cavités déflectrices avant leur installation dans l'anneau sont également décrits. L'activité de mise en fonctionnement de l'expérience est présentée en comparant les mesures faites avec le faisceau aux simulations et calculs théoriques. Finalement, les expériences de multiplication de fréquence des paquets d'électrons sont décrites et analysées. On montre qu'une très bonne efficacité de combinaison est possible après optimisation des paramètres de l'injection et des déflecteurs RF. En plus de l'expérience acquise sur l'utilisation de ces déflecteurs, des conclusions importantes pour les futures activités CTF3 et CLIC sont tirées de cette première démonstration de la multiplication de fréquence des paquets d'électrons par injection RF dans un anneau isochrone.<br/><br/>The Compact LInear Collider (CLIC) collaboration studies the possibility of building a multi-TeV (3 TeV centre-of-mass), high-luminosity (1034 cm-2s-1) electron-positron collider for particle physics. The CLIC scheme is based on high-frequency (30 GHz) linear accelerators powered by a low-energy, high-intensity drive beam running parallel to the main linear accelerators (Two-Beam Acceleration concept). One of the main challenges to realize this scheme is to generate the drive beam in a low-frequency accelerator and to achieve the required high-frequency bunch structure needed for the final acceleration. In order to provide bunch frequency multiplication, the main manipulation consists in sending the beam through an isochronous combiner ring using radio-frequency (RF) deflectors to inject and combine electron bunches. However, such a scheme has never been used before, and the first stage of the CLIC Test Facility 3 (CTF3) project aims at a low-charge demonstration of the bunch frequency multiplication by RF injection into an isochronous ring. This proof-of-principle experiment, which was successfully performed at CERN in 2002 using a modified version of the LEP (Large Electron Positron) pre-injector complex, is the central subject of this report. The bunch combination experiment consists in accelerating in a linear accelerator five pulses in which the electron bunches are spaced by 10 cm, and combining them in an isochronous ring to obtain one pulse in which the electron bunches are spaced by 2 cm, thus achieving a bunch frequency multiplication of a factor five, and increasing the charge per pulse by a factor five. The combination is done by means of RF deflecting cavities that create a time-dependent bump inside the ring, thus allowing the interleaving of the bunches of the five pulses. This process imposes several beam dynamics constraints, such as isochronicity, and specific tolerances on the electron bunches that are defined in this report. The design studies of the CTF3 Preliminary Phase are detailed, with emphasis on the novel injection process using RF deflectors. The high power tests performed on the RF deflectors prior to their installation in the ring are also reported. The commissioning activity is presented by comparing beam measurements to model simulations and theoretical expectations. Eventually, the bunch frequency multiplication experiments are described and analysed. It is shown that the process of bunch frequency multiplication is feasible with a very good efficiency after a careful optimisation of the injection and RF deflector parameters. In addition to the experience acquired in the operation of these RF deflectors, important conclusions for future CTF3 and CLIC activities are drawn from this first demonstration of the bunch frequency multiplication by RF injection into an isochronous ring.<br/><br/>La collaboration CLIC (Compact LInear Collider, collisionneur linéaire compact) étudie la possibilité de réaliser un collisionneur électron-positon linéaire à haute énergie (3 TeV) pour la recherche en physique des particules. Le projet CLIC se fonde sur l'utilisation de cavités accélératrices à haute fréquence (30 GHz). La puissance nécessaire à ces cavités est fournie par un faisceau d'électrons de basse énergie et de haut courant, appelé faisceau de puissance, circulant parallèlement à l'accélérateur linéaire principal (procédé appelé « Accélération à Double Faisceau »). Dans ce schéma, un des principaux défis est la réalisation du faisceau de puissance, qui est d'abord généré dans un complexe accélérateur à basse fréquence, puis transformé pour obtenir une structure temporelle à haute fréquence nécessaire à l'alimentation des cavités accélératrices de l'accélérateur linéaire principal. La structure temporelle à haute fréquence des paquets d'électrons est obtenue par le procédé de multiplication de fréquence, dont la manipulation principale consiste à faire circuler le faisceau d'électrons dans un anneau isochrone en utilisant des déflecteurs radio-fréquence (déflecteurs RF) pour injecter et combiner les paquets d'électrons. Cependant, ce type de manipulation n'a jamais été réalisé auparavant et la première phase de la troisième installation de test pour CLIC (CLIC Test Facility 3 ou CTF3) a pour but la démonstration à faible charge du procédé de multiplication de fréquence par injection RF dans un anneau isochrone. L'expérience consiste à accélérer cinq impulsions, puis à les combiner dans un anneau isochrone pour obtenir une seule impulsion dans laquelle la fréquence des paquets d'électrons et le courant sont multipliés par cinq. Cette combinaison est réalisée au moyen de structures déflectrices RF qui créent dans l'anneau une déformation locale et dépendante du temps de la trajectoire du faisceau. Les résultats de cette expérience, qui a été réalisée avec succès au CERN au cours de l?année 2002 en utilisant une version modifiée du pré-injecteur du grand collisionneur électron-positon LEP (Large Electron Positon), sont présentés en détail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Imatinib (Glivec~ has transformed the treatment and prognosis of chronic myeloid leukaemia (CML) and of gastrointestinal stromal tumor (GIST). However, the treatment must be taken indefinitely and is not devoid of inconvenience and toxicity. Moreover, resistance or escape from disease control occurs. Considering the large interindividual differences in the function of the enzymatic and transport systems involved in imatinib disposition, exposure to this drug can be expected to vary widely among patients. Among those known systems is a cytochrome P450 (CYI'3A4) that metabolizes imatinib, the multidrug transporter P-glycoprotein (P-gp; product of the MDR1 gene) that expels imatinib out of cells, and al-acid glycoprotein (AGP), a circulating protein binding imatinib in the plasma. The aim of this observational study was to explore the influence of these covariates on imatinib pharmacokinetics (PK), to assess the interindividual variability of the PK parameters of the drug, and to evaluate whether imatinib use would benefit from a therapeutic drug monitoring (TDM) program. A total of 321 plasma concentrations were measured in 59 patients receiving imatinib, using a validated chromatographic method developed for this study (HPLC-LTV). The results were analyzed by non-linear mixed effect modeling (NONMEM). A one-compartment pharmacokinetic model with first-order absorption appropriately described the data, and a large interindividual variability was observed. The MDK> polymorphism 3435C>T and the CYP3A4 activity appeared to modulate the disposition of imatinib, albeit not significantly. A hyperbolic relationship between plasma AGP levels and oral clearance, as well as volume of distribution, was observed. A mechanistic approach was built up, postulating that only the unbound imatinib concentration was able to undergo first-order elimination. This approach allowed determining an average free clearance (CL,~ of 13101/h and a volume of distribution (Vd) of 301 1. By comparison, the total clearance determined was 141/h (i.e. 233 ml/min). Free clearance was affected by body weight and pathology diagnosis. The estimated variability of imatinib disposition (17% for CLu and 66% for Vd) decreased globally about one half with the model incorporating the AGP impact. Moreover, some associations were observed between PK parameters of the free imatinib concentration and its efficacy and toxicity. Finally, the functional influence of P-gp activity has been demonstrated in vitro in cell cultures. These elements are arguments to further investigate the possible usefulness of a TDM program for imatinib. It may help in individualizing the dosing regimen before overt disease progression or development of treatment toxicity, thus improving both the long-term therapeutic effectiveness and tolerability of this drug. Résumé L'imatinib (Glivec ®) a révolutionné le traitement et le pronostic de la leucémie myéloïde chronique (LMC) et des tumeurs stromales d'origine digestive (GIST). Il s'agit toutefois d'un traitement non dénué d'inconvénients et de toxicité, et qui doit être pris indéfiniment. Par ailleurs, une résistance, ou des échappements au traitement, sont également rencontrés. Le devenir de ce médicament dans l'organisme dépend de systèmes enzymatiques et de transport connus pour présenter de grandes différences interindividuelles, et l'on peut s'attendre à ce que l'exposition à ce médicament varie largement d'un patient à l'autre. Parmi ces systèmes, on note un cytochrome P450 (le CYP3A4) métabolisant l'imatinib, la P-glycoprotéine (P-gp ;codée par le gène MDR1), un transporteur d'efflux expulsant le médicament hors des cellules, et l'atglycoprotéine acide (AAG), une protéine circulante sur laquelle se fixe l'imatinib dans le plasma. L'objectif de la présente étude clinique a été de déterminer l'influence de ces covariats sur la pharmacocinétique (PK) de l'imatinib, d'établir la variabilité interindividuelle des paramètres PK du médicament, et d'évaluer dans quelle mesure l'imatinib pouvait bénéficier d'un programme de suivi thérapeutique (TDM). En utilisant une méthode chromatographique développée et validée à cet effet (HPLC-UV), un total de 321 concentrations plasmatiques a été dosé chez 59 patients recevant de l'imatinib. Les résultats ont été analysés par modélisation non linéaire à effets mixtes (NONMEM). Un modèle pharmacocinétique à un compartiment avec absorption de premier ordre a permis de décrire les données, et une grande variabilité interindividuelle a été observée. Le polymorphisme du gène MDK1 3435C>T et l'activité du CYP3A4 ont montré une influence, toutefois non significative, sur le devenir de l'imatinib. Une relation hyperbolique entre les taux plasmatiques d'AAG et la clairance, comme le volume de distribution, a été observée. Une approche mécanistique a donc été élaborée, postulant que seule la concentration libre subissait une élimination du premier ordre. Cette approche a permis de déterminer une clairance libre moyenne (CLlibre) de 13101/h et un volume de distribution (Vd) de 301 l. Par comparaison, la clairance totale était de 141/h (c.à.d. 233 ml/min). La CLlibre est affectée par le poids corporel et le type de pathologie. La variabilité interindividuelle estimée pour le devenir de l'imatinib (17% sur CLlibre et 66% sur Vd) diminuait globalement de moitié avec le modèle incorporant l'impact de l'AAG. De plus, une certaine association entre les paramètres PK de la concentration d'imatinib libre et l'efficacité et la toxicité a été observée. Finalement, l'influence fonctionnelle de l'activité de la P-gp a été démontrée in nitro dans des cultures cellulaires. Ces divers éléments constituent des arguments pour étudier davantage l'utilité potentielle d'un programme de TDM appliqué à l'imatinib. Un tel suivi pourrait aider à l'individualisation des régimes posologiques avant la progression manifeste de la maladie ou l'apparition de toxicité, améliorant tant l'efficacité que la tolérabilité de ce médicament. Résumé large public L'imatinib (un médicament commercialisé sous le nom de Glivec ®) a révolutionné le traitement et le pronostic de deux types de cancers, l'un d'origine sanguine (leucémie) et l'autre d'origine digestive. Il s'agit toutefois d'un traitement non dénué d'inconvénients et de toxicité, et qui doit être pris indéfiniment. De plus, des résistances ou des échappements au traitement sont également rencontrés. Le devenir de ce médicament dans le corps humain (dont l'étude relève de la discipline appelée pharmacocinétique) dépend de systèmes connus pour présenter de grandes différences entre les individus, et l'on peut s'attendre à ce que l'exposition à ce médicament varie largement d'un patient à l'autre. Parmi ces systèmes, l'un est responsable de la dégradation du médicament dans le foie (métabolisme), l'autre de l'expulsion du médicament hors des cellules cibles, alors que le dernier consiste en une protéine (dénommée AAG) qui transporte l'imatinib dans le sang. L'objectif de notre étude a été de déterminer l'influence de ces différents systèmes sur le comportement pharmacocinétique de l'imatinib chez les patients, et d'étudier dans quelle mesure le devenir de ce médicament dans l'organisme variait d'un patient à l'autre. Enfin, cette étude avait pour but d'évaluer à quel point la surveillance des concentrations d'imatinib présentes dans le sang pourrait améliorer le traitement des patients cancéreux. Une telle surveillance permet en fait de connaître l'exposition effective de l'organisme au médicament (concept abrégé par le terme anglais TDM, pour Therapeutic Drag Monitoring. Ce projet de recherche a d'abord nécessité la mise au point d'une méthode d'analyse pour la mesure des quantités (ou concentrations) d'imatinib présentes dans le sang. Cela nous a permis d'effectuer régulièrement des mesures chez 59 patients. Il nous a ainsi été possible de décrire le devenir du médicament dans le corps à l'aide de modèles mathématiques. Nous avons notamment pu déterminer chez ces patients la vitesse à laquelle l'imatinib est éliminé du sang et l'étendue de sa distribution dans l'organisme. Nous avons également observé chez les patients que les concentrations sanguines d'imatinib étaient très variables d'un individu à l'autre pour une même dose de médicament ingérée. Nous avons pu aussi mettre en évidence que les concentrations de la protéine AAG, sur laquelle l'imatinib se lie dans le sang, avait une grande influence sur la vitesse à laquelle le médicament est éliminé de l'organisme. Ensuite, en tenant compte des concentrations sanguines d'imatinib et de cette protéine, nous avons également pu calculer les quantités de médicament non liées à cette protéine (= libres), qui sont seules susceptibles d'avoir une activité anticancéreuse. Enfin, il a été possible d'établir qu'il existait une certaine relation entre ces concentrations, l'effet thérapeutique et la toxicité du traitement. Tous ces éléments constituent des arguments pour approfondir encore l'étude de l'utilité d'un programme de TDM appliqué à l'imatinib. Comme chaque patient est différent, un tel suivi pourrait aider à l'ajustement des doses du médicament avant la progression manifeste de la maladie ou l'apparition de toxicité, améliorant ainsi tant son efficacité que son innocuité.