799 resultados para Radiography, Bitewing


Relevância:

10.00% 10.00%

Publicador:

Resumo:

It has been shown that the accuracy of mammographic abnormality detection methods is strongly dependent on the breast tissue characteristics, where a dense breast drastically reduces detection sensitivity. In addition, breast tissue density is widely accepted to be an important risk indicator for the development of breast cancer. Here, we describe the development of an automatic breast tissue classification methodology, which can be summarized in a number of distinct steps: 1) the segmentation of the breast area into fatty versus dense mammographic tissue; 2) the extraction of morphological and texture features from the segmented breast areas; and 3) the use of a Bayesian combination of a number of classifiers. The evaluation, based on a large number of cases from two different mammographic data sets, shows a strong correlation ( and 0.67 for the two data sets) between automatic and expert-based Breast Imaging Reporting and Data System mammographic density assessment

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A recent trend in digital mammography is computer-aided diagnosis systems, which are computerised tools designed to assist radiologists. Most of these systems are used for the automatic detection of abnormalities. However, recent studies have shown that their sensitivity is significantly decreased as the density of the breast increases. This dependence is method specific. In this paper we propose a new approach to the classification of mammographic images according to their breast parenchymal density. Our classification uses information extracted from segmentation results and is based on the underlying breast tissue texture. Classification performance was based on a large set of digitised mammograms. Evaluation involves different classifiers and uses a leave-one-out methodology. Results demonstrate the feasibility of estimating breast density using image processing and analysis techniques

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new approach to mammographic mass detection is presented in this paper. Although different algorithms have been proposed for such a task, most of them are application dependent. In contrast, our approach makes use of a kindred topic in computer vision adapted to our particular problem. In this sense, we translate the eigenfaces approach for face detection/classification problems to a mass detection. Two different databases were used to show the robustness of the approach. The first one consisted on a set of 160 regions of interest (RoIs) extracted from the MIAS database, being 40 of them with confirmed masses and the rest normal tissue. The second set of RoIs was extracted from the DDSM database, and contained 196 RoIs containing masses and 392 with normal, but suspicious regions. Initial results demonstrate the feasibility of using such approach with performances comparable to other algorithms, with the advantage of being a more general, simple and cost-effective approach

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivos : evaluar las características operativas del examen físico en el diagnóstico de neumonía y evaluar su acuerdo inter-observador. Marco de referencia : los estudios que avaluaron al examen físico como prueba diagnóstica en neumonía son metodológicamente deficientes. Diseño : estudio ciego de corte transversal para evaluación de prueba diagnóstica. Pacientes : adultos quienes consultan al servicio de urgencias y hospitalización de la FCI por síntomas respiratorios agudos o exacerbación de los mismos. Mediciones : examen físico por dos observadores independientes, toma de radiografía de tórax y lectura por radiólogo experto. Se tomaron los datos que permitieron calcular el índice de severidad de neumonía (PSI). Resultados : de 198 pacientes, 85(42%) tenían neumonía radiográficamente. Las características operativas del examinador1 fueron: Sensibilidad:63.2%, Especificidad:54,1%, LR(+)=1,36, LR(-)=0,68; para el examinador2: Sensibilidad:34,3%, Especificidad:71,7%, LR(+)=1,17, LR(-)=0,92. La correlación entre diagnóstico clínico para derrame pleural fue k=-0,052, no significativa (p=0,445); y para neumonía k=0.25 significativa (p=0.022). Al medirse la severidad de neumonía por PSI, la sensibilidad aumento estratificada a severidad (II:Sensibilidad:40%; III:Sensibilidad: 57%; IV:Sensibilidad;75%; V:Sensibilidad:80%). Conclusiones : el examen físico no es sensible ni especifico en el diagnóstico de neumonía. Existe un índice de acuerdo débil en el examen físico de tórax para el diagnóstico de derrame pleural y neumonía Es más probable el diagnóstico clínico de neumonía al aumentar la severidad por PSI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introducción: la utilidad de las radiografías de tórax rutinarias se encuentra en discusión, con estudios que avalan su uso y, en el otro extremo, estudios que solo encuentran utilidad marginal. Objetivos: determinar la eficacia diagnóstica y terapéutica de las radiografías de tórax rutinarias matutinas en pacientes pediátricos bajo ventilación mecánica y la identificación de subgrupos en quienes dichas radiografías sean de mayor utilidad. Metodología: estudio prospectivo, analítico, transversal, realizado en pacientes de un mes a 18 años, sometidos a ventilación mecánica por más de 48 horas, entre diciembre de 2010 a noviembre de 2011. Se emplearon las pruebas de X2 de Pearson y el test de Fischer. Para el análisis de los datos, se utilizaron los programas Statgraphics y SPSS, versión 15. Resultados: se evaluaron 53 pacientes con 536 radiografías. Los hallazgos fueron principalmente menores. Los hallazgos mayores solo corresponden al 10.3% de los casos, siendo principalmente mal posición del tubo endotraqueal y nuevos infiltrados infecciosos. No fue posible establecer subgrupos pero los datos sugieren mayor utilidad de dichas radiografías en pacientes de menor edad y peso, así como en los sometidos a alto soporte ventilatorio. Conclusiones: la utilidad de las radiografías rutinarias en pacientes pediátricos es marginal, siendo necesaria la realización de nuevos estudios para establecer su eficacia diagnóstica y su utilidad en subgrupos de pacientes. Palabras clave: radiografía de tórax, rayos x de tórax, radiología, unidad de cuidado intensivo, unidad de cuidado crítico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La EPOC es una causa importante de morbilidad y mortalidad en el mundo y su prevalencia en Bogotá alcanza hasta 8,5%. Las exacerbaciones están asociadas a deterioro funcional y de la calidad de vida por lo que se consideran un factor cardinal de la enfermedad. En la literatura se ha descrito que las infecciones por bacterias y/o virus son las responsables del 78% de las exacerbaciones. Estos datos han sido descritos en poblaciones diferentes y no hay datos en la literatura que muestren cual es la epidemiología local de las exacerbaciones de EPOC y menos aún de aquellas que se asocian a consolidaciones neumónicas. Objetivo: Comparar la microbiología de las exacerbaciones severas de la EPOC que requieren ingreso a UCI con y sin infiltrados alveolares. Materiales y métodos: Estudio de corte transversal en el que se estudiaron pacientes con EPOC que ingresaron a la UCI Médica de la FCI-IC por exacerbación severa, asociada o no a infiltrados alveolares. Se tomaron muestras de microbiología, serológicas y radiografía de tórax para evaluar la etiología de la exacerbación, si se asocia a coinfección viral y a consolidación neumónica o no. Resultados: No se encontró una diferencia estadísticamente significativa en la microbiología de los diferentes grupos evaluados. Se encontró un resistencia global del 24% y llama la atención que hay una alta prevalencia de Serratia Marcescens AMPc entre los 2 grupos, germen que no está descrito como patógeno común en la literatura. Se encontraron diferencias en cuanto a factores de riesgo para presentar neumonía asociada como lo son un mayor índice de paquetes/año (55.1.6 vs. 36.3 paq/año, sig.=0.021). Así mismo se demostró que los pacientes con neumonía asociada presentan mayor necesidad de IOT (48.9 vs. 23.9, sig.=0.013). No hay diferencia significativa en desenlaces como mortalidad (20.5 vs. 13.0, sig.=0.346). Conclusiones: A pesar de no haber diferencia microbiológica entre los 2 grupos se encontraron variables como factores de riesgo y variables clínicas que pueden ayudar a proponer planes de manejo en los dos escenarios. El hecho de encontrar un paciente con neumonía asociada al cuadro de exacerbación no debe afectar en la toma de decisiones en relación al tratamiento antibiótico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introducción. Las imágenes obtenidas mediante rayos X, determinan una conducta clínica en ortopedia y son analizadas por parte del cirujano en el momento previo a realizar un acto quirúrgico. El planeamiento pre quirúrgico basado en radiografías de cadera, permite predecir el tamaño de los componentes protésicos a utilizar en un reemplazo de cadera. Con el advenimiento de las radiografías digitales, existe la falsa percepción de que estas tienen corregido el factor de magnificación. La corrección de dicho factor requiere un protocolo de calibración de imágenes, aún no implementado en la Fundación Santa Fe de Bogotá (FSFB). Como consecuencia, las radiografías de cadera actualmente resultan magnificadas. Materiales y métodos. Fueron seleccionados 73 pacientes con reemplazo articular total de la cadera intervenidos en la FSFB. Para cada paciente, se estableció la dimensión de la cabeza protésica en la radiografía de cadera obtenida mediante el sistema de radiología digital (PACS-IMPAX) y su tamaño fue comparado con el de la cabeza femoral implantada. Resultados. La concordancia entre los dos observadores al medir la dimensión radiológica de los componentes protésicos fue excelente y el coeficiente de magnificación promedio de 1.2 (20%). Este será introducido al PACS-IMPAX para ajustar el tamaño definitivo de la radiografía. Conclusión. El ajuste del PACS-IMPAX permite obtener radiografías en las cuales se refleja con mayor precisión el tamaño de los segmentos anatómicos y de los componentes protésicos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El trauma de codo y la fractura de cúpula radial resultan ser un motivo de consulta frecuente en nuestro medio. Es común en nuestro medio que a pesar de tener radiografías de codo en las que se evidencia fractura de cúpula radial se solicite un TAC de codo. Consideramos que el TAC es una herramienta útil en algunos casos de fracturas de la cúpula radial, es decir, no se debe tomar de forma rutinaria el TAC de codo en los pacientes con fracturas de cúpula radial como es usual en nuestro medio. Existen pocos estudios que comparan la concordancia inter observador de las clasificaciones utilizadas para las fracturas de cúpula radial, pero, no existe en la literatura mundial un estudio que evalué las diferencias entre la clasificación de la fractura en base a radiografías y tomografía entre un grupo ortopedistas traumatólogos y sub-especialistas de miembro superior. La realización de este estudio permite elaborar guías de manejo de pacientes con fractura de cúpula radial en la que se racionalizara el uso del TAC de codo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introducción: Conocer y diagnosticar las variaciones más frecuentes de la vasculatura renal es de gran importancia para la planificación de la nefrectomía laparoscópica en el donante y para la reconstrucción vascular en el trasplante renal. De igual forma, considerar las variaciones vasculares −especialmente las del sistema venoso− es indispensable en reconstrucción vascular debido a la gran proporción de variaciones venosas asociadas a aneurismas de la aorta abdominal; además, es ideal en el estudio de condiciones clínicas tales como el síndrome de congestión pélvica y la hematuria. Metodología: Se trata de una revisión de la bibliografía sobre la proporción, diagnóstico, procedimientos quirúrgicos y síndromes clínicos asociados a las variaciones de la vasculatura renal, basada en el material encontrado con la siguiente estrategia de búsqueda: “Renal Artery/abnormalities”[Mesh] OR Renal Veins/abnormalities”[Mesh] AND “surgery”[Mesh] OR “transplantation”[Mesh] OR “radiography”[Mesh] “Kidney Pelvis/abnormalities”[Mesh] AND “Kidney Pelvis/blood supply”[Mesh]. Esta estrategia se modificó de acuerdo con las bases de datos: MEDLINE/PubMed, MEDLINE OVID, SCIENCEDIRECT, HINARI y LILACS. Desarrollo: Se revisó el origen y los tipos más frecuentes de variaciones de la vasculatura renal. Se investigó sobre las implicaciones quirúrgicas y los síndromes clínicos asociados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo Realizar una revisión sistemática de la neumonía lipoidea exógena (NLE) con el propósito de compactar y sintetizar los conocimientos fragmentados, así como el de informar el estado actual de este tema como riesgo laboral. Metodología La neumonía lipoidea es una condición poco común que resulta de la presencia de lípidos en el interior del espacio alveolar, se desconoce su actual incidencia. La neumonía lipoidea exógena se produce por aspiración o inhalación de sustancias oleosas, es una patología rara en pacientes sin enfermedades de base que predispongan a la broncoaspiración y cuando se presenta en individuos sanos se debe sospechar un origen ocupacional. Se realizó una revisión de literatura según la metodología estandarizada, incluyendo en la búsqueda: reporte de casos, descripciones de la enfermedad y el uso de técnicas diagnósticas. Las bases de datos fueron OVID además de GOOGLE ACADÉMICO; buscadores específicos: MEDLINE, CHEST, PUB MED, REDALYC, SCIELO, Europe PubMed Central (Europe PMC) y ELSEVIER. La búsqueda estuvo además, orientada por una serie de preguntas orientadoras sobre la neumonía lipoidea exógena (NLE) como riesgo laboral. Los artículos que cumplieron con los criterios de inclusión, se clasificaron de acuerdo con tipo de estudio, la calidad del artículo y finalmente se evaluaron con base en una lista de chequeo ajustada para este fin. Resultados Se seleccionó un total de 71 estudios incluyendo reporte de casos, descripciones de la enfermedad y técnicas diagnósticas; publicaciones provenientes de 21 países. Un total de 63 casos, 31 en mujeres (49,20%) y 32 en hombres (50,8%) fueron reportados; el 7,93% de los casos fueron atribuidos a la exposición de agentes en el ambiente laboral: combustibles, parafina/pintura/ pulverizaciones oleosas y diésel, ambientes propios de trabajadores de almacenes de pinturas y conductores de vehículos. Los síntomas de la neumonía lipoidea exógena (NLE) descritos fueron muy variables, puede cursar asintomática o con presencia de fiebre, disnea y tos irritativa; dolor torácico, en algunos casos hemoptisis, cianosis y pérdida de peso; El examen físico generalmente es normal, aunque puede revelar sibilancias o roncus. En pruebas de función respiratoria tales como la espirometría, se presenta un patrón restrictivo, además puede hallarse un descenso en la capacidad de difusión para el monóxido de carbono. En el hemograma puede detectarse leucocitosis con predominio de neutrófilos y aumento de la velocidad de sedimentación globular, hallazgos que también pueden ser producidos por una infección concomitante. Conclusiones Se destaca el hallazgo en la literatura de los diferentes agentes causales presentes en el ambiente laboral que pueden incidir en la aparición de la enfermedad: combustibles, parafina/pintura/ pulverizaciones oleosas y diésel, ambientes propios de trabajadores de almacenes de pinturas y conductores de vehículos. Se presentó neumonía lipoidea exógena (NLE) de tipo agudo después de 30 minutos a 24 horas de exposición masiva a aceites y sustancias oleosas, luego de de ocho meses a 9,5 años de inhalación continua secundaria. Los métodos más para de la diagnóstico enfermedad incluyen el lavado broncoalveolar (BAL), la biopsia de pulmón y la con radiografía torácica. Finalmente, es posible que en pacientes con neumonía lipoidea exógena, puedan presentarse complicaciones asociadas tales como: sobreinfección, fibrosis, retracción de las lesiones, cáncer de pulmón, bronconeumonías recurrentes e hipercalcemia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diversas clasificaciones radiológicas han sido desarrolladas para apoyar el diagnóstico de la neumoconiosis. El propósito de este estudio fue comparar la concordancia de los hallazgos radiográficos relacionados con el diagnóstico de neumoconiosis detectados en la lectura de la radiografía de tórax realizada por medico entrenado en sistema de clasificación de la Organización Internacional del Trabajo (OIT 2.000) y radiólogo especialista. Metodología: Estudio descriptivo. Se comparó la lectura realizada a 142 radiografías de tórax convencionales respecto a hallazgos sugestivos de neumoconiosis detectados por el medico entrenado en la clasificación internacional de la OIT y radiólogo especialista, utilizando el índice de Kappa para concordancia entre dos observadores, también se tuvieron en cuenta observaciones reportadas sobre calidad cinematográfica en la toma de la radiografía y otros hallazgos diferentes o afines a neumoconiosis. Resultados: En 47 lecturas OIT, 33,1% y 9,9% (14) lecturas de radiólogo, hubo hallazgos sugestivos de neumoconiosis. En 123 (86,6%) lecturas OIT y 1 (0,7%) lectura de radiólogo, hubo hallazgos de falta de calidad técnica. En 26 (18,3%) lecturas OIT, y 9 (6,3%) lecturas de radiólogo, hubo detección de otros hallazgos. El acuerdo inter-lector de hallazgos sugestivos de neumoconiosis fue débil con un valor Kappa de 0.245, el de Calidad técnica fue pobre, con valor Kappa de 0.02 y el acuerdo en la detección de otros hallazgos diferentes a neumoconiosis fue débil con valor Kappa de 0.274. Conclusiones: El sistema de clasificación de la OIT puede ser más sensible para detectar hallazgos sugestivos de neumoconiosis, de falta de calidad técnica y otros hallazgos en la radiografía de tórax.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introducción: La utilidad de la tomografía computarizada como prueba de rutina en la toma de decisiones para las fracturas de radio distal no ha sido bien establecida. Metodología: Estudio de concordancia intra e interobservador en el tratamiento de fracturas de radio distal Fernández V. Se realizaron dos visitas, con intervalo de 2 semanas entre ellas a 15 ortopedistas de trauma quienes evaluaron 22 radiografías de muñeca y sus respectivas tomografías con fracturas de radio distal Fernández V, determinaron para cada caso la mejor opción de tratamiento. Se utilizó el coeficiente Kappa para evaluar la concordancia intra e interobservador para el plan de tratamiento propuesto y se analizaron los resultados según la interpretación de este coeficiente según Landis y Koch. Resultados: La concordancia entre radiografía y tomografía fue moderada kappa 0,47 – 0,51 en las dos evaluaciones respectivamente, manteniéndose el cambio de tratamiento entre 24,9% y 26,7% (p‹0,001). La concordancia observada intraobservador para radiografía y tomografía evaluadas de manera individual fue buena (72,1% y 64,2% respectivamente) evidenciándose cambio en la decisión de tratamiento hasta en el 35,8% de las evaluaciones (p‹0,001); se determinó concordancia observada muy buena en los casos a los que se propuso manejo abierto. No se identificó influencia de la edad en la decisión de tratamiento. Conclusiones: Existe buena concordancia entre radiografía simple y tomografía en fracturas de radio distal Fernández V en cuanto a la decisión de tratamiento, siendo alta la concordancia en los casos en los que se decide manejo abierto.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La esclerosis sistémica (ES) es una enfermedad autoinmune multisistémica que afecta principalmente la piel, los pulmones, el tracto gastrointestinal, el corazón y los riñones. La enfermedad pulmonar, presente en casi el 100% de los casos, es el factor con mayor influencia en la mortalidad. El propósito de este estudio es realizar un análisis detallado de la enfermedad pulmonar por tomografía computarizada de alta resolución(TCAR) en pacientes Colombianos con ES, para lo cual se realizó un estudio de prevalencia analítica en 44 pacientes con ES valorados en el Hospital Universitario Mayor Méderi en los últimos 7 años. Los resultados mostraron características demográficas y clínicas similares a las previamente descritas. La prevalencia de enfermedad pulmonar intersticial fue alta, y los hallazgos de fibrosis pulmonar como vidrio esmerilado y panal de abejas se asociaron con la presencia del autoanticuerpo antiSCL70. La medida del diámetro esofágico por TCAR fue mayor en los pacientes con disfagia, antiSCL 70 y linfopenia, los cuales son marcadores de mal pronóstico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Early detection of breast cancer (BC) with mammography may cause overdiagnosis and overtreatment, detecting tumors which would remain undiagnosed during a lifetime. The aims of this study were: first, to model invasive BC incidence trends in Catalonia (Spain) taking into account reproductive and screening data; and second, to quantify the extent of BC overdiagnosis. We modeled the incidence of invasive BC using a Poisson regression model. Explanatory variables were: age at diagnosis and cohort characteristics (completed fertility rate, percentage of women that use mammography at age 50, and year of birth). This model also was used to estimate the background incidence in the absence of screening. We used a probabilistic model to estimate the expected BC incidence if women in the population used mammography as reported in health surveys. The difference between the observed and expected cumulative incidences provided an estimate of overdiagnosis.Incidence of invasive BC increased, especially in cohorts born from 1940 to 1955. The biggest increase was observed in these cohorts between the ages of 50 to 65 years, where the final BC incidence rates more than doubled the initial ones. Dissemination of mammography was significantly associated with BC incidence and overdiagnosis. Our estimates of overdiagnosis ranged from 0.4% to 46.6%, for women born around 1935 and 1950, respectively.Our results support the existence of overdiagnosis in Catalonia attributed to mammography usage, and the limited malignant potential of some tumors may play an important role. Women should be better informed about this risk. Research should be oriented towards personalized screening and risk assessment tools

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este estudo teve como objetivo avaliar e comparar as doses de radiação recolhidas numa amostra de 69 pacientes, em dois hospitais, com diferentes métodos de aquisição de imagem digital, direta e indireta, que realizaram radiografia de tórax, em projeção postero-anterior (PA). Para os dois hospitais, a dose à entrada da pele (DEP) e efectiva (E), foram medidas usando o software PCXMC para comparação entre si e com referências internacionais. No Hospital A, com aquisição digital direta, a média de DEP foi de 0,089 mGy e a média de E foi 0,013 mSv. No Hospital B, com aquisição digital de indireta, a média de DEP foi de 0.151 mGy e a média de E foi 0.030mSv. Em ambos os hospitais, as doses médias não ultrapassaram os limites recomendados por lei (0,3 mGy). Para a radiografia de tórax PA, o nível de referência diagnostico (NRD) local calculado foi 0.107 mGy, para o Hospital A e 0.164 mGy, para o Hospital B. Na radiografia de tórax PA, a utilização de um sistema de aquisição direta implicou uma redução de dose de 41 %, concordante com as referências disponíveis que apontam para a redução da dose de cerca de 50 % entre os dois sistemas.