971 resultados para RADIATION DETECTORS
Resumo:
Brain perfusion can be assessed by CT and MR. For CT, two major techniques are used. First, Xenon CT is an equilibrium technique based on a freely diffusible tracer. First pass of iodinated contrast injected intravenously is a second method, more widely available. Both methods are proven to be robust and quantitative, thanks to the linear relationship between contrast concentration and x-ray attenuation. For the CT methods, concern regarding x-ray doses delivered to the patients need to be addressed. MR is also able to assess brain perfusion using the first pass of gadolinium based contrast agent injected intravenously. This method has to be considered as a semi-quantitative because of the non linear relationship between contrast concentration and MR signal changes. Arterial spin labeling is another MR method assessing brain perfusion without injection of contrast. In such case, the blood flow in the carotids is magnetically labelled by an external radiofrequency pulse and observed during its first pass through the brain. Each of this various CT and MR techniques have advantages and limits that will be illustrated and summarized.Learning Objectives:1. To understand and compare the different techniques for brain perfusion imaging.2. To learn about the methods of acquisition and post-processing of brain perfusion by first pass of contrast agent for CT and MR.3. To learn about non contrast MR methods (arterial spin labelling).
Resumo:
Background. DNA-damage assays, quantifying the initial number of DNA double-strand breaks induced by radiation, have been proposed as a predictive test for radiation-induced toxicity. Determination of radiation-induced apoptosis in peripheral blood lymphocytes by flow cytometry analysis has also been proposed as an approach for predicting normal tissue responses following radiotherapy. The aim of the present study was to explore the association between initial DNA damage, estimated by the number of double-strand breaks induced by a given radiation dose, and the radio-induced apoptosis rates observed. Methods. Peripheral blood lymphocytes were taken from 26 consecutive patients with locally advanced breast carcinoma. Radiosensitivity of lymphocytes was quantified as the initial number of DNA double-strand breaks induced per Gy and per DNA unit (200 Mbp). Radio-induced apoptosis at 1, 2 and 8 Gy was measured by flow cytometry using annexin V/propidium iodide. Results. Radiation-induced apoptosis increased in order to radiation dose and data fitted to a semi logarithmic mathematical model. A positive correlation was found among radio-induced apoptosis values at different radiation doses: 1, 2 and 8 Gy (p < 0.0001 in all cases). Mean DSB/Gy/DNA unit obtained was 1.70 ± 0.83 (range 0.63-4.08; median, 1.46). A statistically significant inverse correlation was found between initial damage to DNA and radio-induced apoptosis at 1 Gy (p = 0.034). A trend toward 2 Gy (p = 0.057) and 8 Gy (p = 0.067) was observed after 24 hours of incubation. Conclusions. An inverse association was observed for the first time between these variables, both considered as predictive factors to radiation toxicity.
Resumo:
INTRODUCTION Radiotherapy outcomes might be further improved by a greater understanding of the individual variations in normal tissue reactions that determine tolerance. Most published studies on radiation toxicity have been performed retrospectively. Our prospective study was launched in 1996 to measure the in vitro radiosensitivity of peripheral blood lymphocytes before treatment with radical radiotherapy in patients with breast cancer, and to assess the early and the late radiation skin side effects in the same group of patients. We prospectively recruited consecutive breast cancer patients receiving radiation therapy after breast surgery. To evaluate whether early and late side effects of radiotherapy can be predicted by the assay, a study was conducted of the association between the results of in vitro radiosensitivity tests and acute and late adverse radiation effects. METHODS Intrinsic molecular radiosensitivity was measured by using an initial radiation-induced DNA damage assay on lymphocytes obtained from breast cancer patients before radiotherapy. Acute reactions were assessed in 108 of these patients on the last treatment day. Late morbidity was assessed after 7 years of follow-up in some of these patients. The Radiation Therapy Oncology Group (RTOG) morbidity score system was used for both assessments. RESULTS Radiosensitivity values obtained using the in vitro test showed no relation with the acute or late adverse skin reactions observed. There was no evidence of a relation between acute and late normal tissue reactions assessed in the same patients. A positive relation was found between the treatment volume and both early and late side effects. CONCLUSION After radiation treatment, a number of cells containing major changes can have a long survival and disappear very slowly, becoming a chronic focus of immunological system stimulation. This stimulation can produce, in a stochastic manner, late radiation-related adverse effects of varying severity. Further research is warranted to identify the major determinants of normal tissue radiation response to make it possible to individualize treatments and improve the outcome of radiotherapy in cancer patients.
Resumo:
An international exercise, registered as EUROMET project no. 907, was launched to measure both the activity of a solution of (124)Sb and the photon emission intensities of its decay. The same solution was sent by LNE-LNHB to eight participating laboratories. In order to identify possible biases, the participants were asked to use all possible activity measurement methods available in their laboratory and then to determine their reference value for comparison. Thus, measurement results from 4pibeta-gamma coincidence/anti-coincidence counting, CIEMAT/NIST liquid-scintillation counting, 4pigamma counting with well-type ionization chambers and well-type crystal detectors were given. The results are compared and show a maximum discrepancy of about 1.6%: possible explanations are proposed.
Resumo:
BACKGROUND. Either higher levels of initial DNA damage or lower levels of radiation-induced apoptosis in peripheral blood lymphocytes have been associated to increased risk for develop late radiation-induced toxicity. It has been recently published that these two predictive tests are inversely related. The aim of the present study was to investigate the combined role of both tests in relation to clinical radiation-induced toxicity in a set of breast cancer patients treated with high dose hyperfractionated radical radiotherapy. METHODS. Peripheral blood lymphocytes were taken from 26 consecutive patients with locally advanced breast carcinoma treated with high-dose hyperfractioned radical radiotherapy. Acute and late cutaneous and subcutaneous toxicity was evaluated using the Radiation Therapy Oncology Group morbidity scoring schema. The mean follow-up of survivors (n = 13) was 197.23 months. Radiosensitivity of lymphocytes was quantified as the initial number of DNA double-strand breaks induced per Gy and per DNA unit (200 Mbp). Radiation-induced apoptosis (RIA) at 1, 2 and 8 Gy was measured by flow cytometry using annexin V/propidium iodide. RESULTS. Mean DSB/Gy/DNA unit obtained was 1.70 ± 0.83 (range 0.63-4.08; median, 1.46). Radiation-induced apoptosis increased with radiation dose (median 12.36, 17.79 and 24.83 for 1, 2, and 8 Gy respectively). We observed that those "expected resistant patients" (DSB values lower than 1.78 DSB/Gy per 200 Mbp and RIA values over 9.58, 14.40 or 24.83 for 1, 2 and 8 Gy respectively) were at low risk of suffer severe subcutaneous late toxicity (HR 0.223, 95%CI 0.073-0.678, P = 0.008; HR 0.206, 95%CI 0.063-0.677, P = 0.009; HR 0.239, 95%CI 0.062-0.929, P = 0.039, for RIA at 1, 2 and 8 Gy respectively) in multivariate analysis. CONCLUSIONS. A radiation-resistant profile is proposed, where those patients who presented lower levels of initial DNA damage and higher levels of radiation induced apoptosis were at low risk of suffer severe subcutaneous late toxicity after clinical treatment at high radiation doses in our series. However, due to the small sample size, other prospective studies with higher number of patients are needed to validate these results.
Resumo:
The shape of the energy spectrum produced by an x-ray tube has a great importance in mammography. Many anode-filtration combinations have been proposed to obtain the most effective spectrum shape for the image quality-dose relationship. On the other hand, third generation synchrotrons such as the European Synchrotron Radiation Facility in Grenoble are able to produce a high flux of monoenergetic radiation. It is thus a powerful tool to study the effect of beam energy on image quality and dose in mammography. An objective method was used to evaluate image quality and dose in mammography with synchrotron radiation and to compare them to standard conventional units. It was performed systematically in the energy range of interest for mammography through the evaluation of a global image quality index and through the measurement of the mean glandular dose. Compared to conventional mammography units, synchrotron radiation shows a great improvement of the image quality-dose relationship, which is due to the beam monochromaticity and to the high intrinsic collimation of the beam, which allows the use of a slit instead of an anti-scatter grid for scatter rejection.
Resumo:
Nepal has a long history of medical radiology since1923 but unfortunately, we still do not have any Radiation Protection Infrastructure to control the use of ionizing radiations in the various fields. The objective of this study was an assessment of the radiation protection in medical uses of ionizing radiation. Twenty-eight hospitals with diagnostic radiology facility were chosen for this study according to patient loads, equipment and working staffs. Radiation surveys were also done at five different radiotherapy centers. Questionnaire for radiation workers were used; radiation dose levels were measured and an inventory of availability of radiation equipment made. A corollary objective of the study was to create awareness in among workers on possible radiation health hazard and risk. It was also deemed important to know the level of understanding of the radiation workers in order to initiate steps towards the establishment of Nepalese laws, regulation and code of radiological practice in this field. Altogether, 203 Radiation workers entertained the questionnaire, out of which 41 are from the Radiotherapy and 162 are from diagnostic radiology. The radiation workers who have participated in the questionnaire represent more than 50% of the radiation workers working in this field in Nepal. Almost all X-ray, CT and Mammogram installations were built according to protection criteria and hence found safe. Radiation dose level at the reference points for all the five Radiotherapy centers are within safe limit. Around 65% of the radiation workers have never been monitored for radiation. There is no quality control program in any of the surveyed hospitals except radiotherapy facilities.
Resumo:
L'objectiu d'aquest treball de final de carrera és desenvolupar un sistema d'alarma contra incendis basat en tecnologia WSN (xarxa de sensors sense fils).
Resumo:
This is one of the few studies that have explored the value of baseline symptoms and health-related quality of life (HRQOL) in predicting survival in brain cancer patients. Baseline HRQOL scores (from the EORTC QLQ-C30 and the Brain Cancer Module (BN 20)) were examined in 490 newly diagnosed glioblastoma cancer patients for the relationship with overall survival by using Cox proportional hazards regression models. Refined techniques as the bootstrap re-sampling procedure and the computation of C-indexes and R(2)-coefficients were used to try and validate the model. Classical analysis controlled for major clinical prognostic factors selected cognitive functioning (P=0.0001), global health status (P=0.0055) and social functioning (P<0.0001) as statistically significant prognostic factors of survival. However, several issues question the validity of these findings. C-indexes and R(2)-coefficients, which are measures of the predictive ability of the models, did not exhibit major improvements when adding selected or all HRQOL scores to clinical factors. While classical techniques lead to positive results, more refined analyses suggest that baseline HRQOL scores add relatively little to clinical factors to predict survival. These results may have implications for future use of HRQOL as a prognostic factor in cancer patients.
Resumo:
Background Surgery of radiation-induced cataracts in children with retinoblastoma (RB) is a challenge as early intervention is weighted against the need to delay surgery until complete tumour control is obtained. This study analyses the safety and functional results of such surgery. Methods In a retrospective, non-comparative, consecutive case series, we reviewed medical records of RB patients </=14 y of age who underwent either external beam radiotherapy or plaque treatment and were operated for radiation-induced cataract between 1985 and 2008. Results In total, 21 eyes of 20 RB patients were included and 18 out of the 21 eyes had Reese-Ellsworth stage V or ABC classification group D/E RB. Median interval between last treatment for RB and cataract surgery was 21.5 months, range 3-164 months. Phacoaspiration was performed in 13 eyes (61%), extra-capsular cataract extraction in 8 (39%) and intraocular lens implantation in 19 eyes (90%). The majority of cases, 11/21 (52%), underwent posterior capsulorhexis or capsulotomy and 6/21 (28%) an anterior vitrectomy. Postoperative visual acuity was >/=20/200 in 13 eyes and <20/200 in 5 eyes. Intraocular tumour recurrence was noted in three eyes. Mean postoperative follow up was 90 months+/-69 months. Conclusions Modern cataract surgery, including clear cornea approach, lens aspiration with posterior capsulotomy, anterior vitrectomy and IOL implantation is a safe procedure for radiation-induced cataract as long as RB is controlled. The visual prognosis is limited by initial tumour involvement of the macula and by corneal complications of radiotherapy. We recommend a minimal interval of 9 months between completion of treatment of retinoblastoma and cataract surgery.
Resumo:
The oncologic outcome and the total dose are highly correlated with the treatment by ionizing radiation. The dose increase (total or per fraction) may provoke late-side effects that are potentially irreversible. The radiation-induced CD8 lymphocyte apoptotic value and the molecular modifications within the lymphocyte are capable of predicting the level of risk of developing late-side effects after curative intent radiotherapy. In this review, we present the different blood assays in this setting and discuss the current possibilities of researches, namely those involving the proteomic process.
Resumo:
PURPOSE: Since 1982, the Radiation Oncology Group of the EORTC (EORTC ROG) has pursued an extensive Quality Assurance (QA) program involving all centres actively participating in its clinical research. The first step is the evaluation of the structure and of the human, technical and organisational resources of the centres, to assess their ability to comply with the current requirements for high-tech radiotherapy (RT). MATERIALS AND METHODS: A facility questionnaire (FQ) was developed in 1989 and adapted over the years to match the evolution of RT techniques. We report on the contents of the current FQ that was completed online by 98 active EORTC ROG member institutions from 19 countries, between December 2005 and October 2007. RESULTS: Similar to the data collected previously, large variations in equipment, staffing and workload between centres remain. Currently only 15 centres still use a Cobalt unit. All centres perform 3D Conformal RT, 79% of them can perform IMRT and 54% are able to deliver stereotactic RT. An external reference dosimetry audit (ERDA) was performed in 88% of the centres for photons and in 73% for electrons, but it was recent (<2 years) in only 74% and 60%, respectively. CONCLUSION: The use of the FQ helps maintain the minimum quality requirements within the EORTC ROG network: recommendations are made on the basis of the analysis of its results. The present analysis shows that modern RT techniques are widely implemented in the clinic but also that ERDA should be performed more frequently. Repeated assessment using the FQ is warranted to document the future evolution of the EORTC ROG institutions.